On flow effects in balanced steady-state free precession imaging: pictorial description, parameter dependence, and clinical implications.

PURPOSE: To present a pictorial description of the origin of flow effects in balanced steady-state free precession (SSFP) imaging that can result in considerable frequency offset-dependent signal changes originating from outflow of spins that can still contribute to the total SSFP signal (out-of-slice contributions), to analyze the parameter dependence and slice broadening associated with outflow effects, and to illustrate clinical implications such as frequency offset-dependent flow artifacts and spatial misencoding. MATERIALS AND METHODS: Computer simulations were used to create a pictorial description of flow effects that illustrates the origin and parameter dependence of the observed signal changes and links their frequency dependency to the phase distribution of spins flowing in and out of the imaging slice. Slice broadening associated with out-of-slice contributions and flow-related signal enhancement was characterized by an effective slice thickness, which depends on flow rate, the T2* decay of signal magnitude from spins that have left the imaging slice, and the ratio of the net out-of-slice magnetization relative to the thickness of the imaging slice. RESULTS: Both simulated SSFP signal intensities and effective slice broadening vary with flip angle and demonstrate a nonlinear dependence on inflow. Simulations with bloodlike T1 and T2 show that the effective slice thickness can be as large as 15 times the prescribed slice thickness. These effects can have significant clinical implications such as large frequency offset-dependent signal enhancement, pulsatile flow artifacts, and spatial misrepresentation of blood signal that has already left the imaging slice. CONCLUSION: Flow-related signal changes in SSFP imaging exhibit highly complex parameter dependence, which predominantly has to be associated with frequency offset-dependent outflow effects and a resulting broadening of the slice thickness.

Artifacts↗

Multicoil Dixon chemical species separation with an iterative least-squares estimation method.

This work describes a new approach to multipoint Dixon fat-water separation that is amenable to pulse sequences that require short echo time (TE) increments, such as steady-state free precession (SSFP) and fast spin-echo (FSE) imaging. Using an iterative linear least-squares method that decomposes water and fat images from source images acquired at short TE increments, images with a high signal-to-noise ratio (SNR) and uniform separation of water and fat are obtained. This algorithm extends to multicoil reconstruction with minimal additional complexity. Examples of single- and multicoil fat-water decompositions are shown from source images acquired at both 1.5T and 3.0T. Examples in the knee, ankle, pelvis, abdomen, and heart are shown, using FSE, SSFP, and spoiled gradient-echo (SPGR) pulse sequences. The algorithm was applied to systems with multiple chemical species, and an example of water-fat-silicone separation is shown. An analysis of the noise performance of this method is described, and methods to improve noise performance through multicoil acquisition and field map smoothing are discussed.

Adipose Tissue↗

Quantification of vessel wall motion and cyclic strain using cine phase contrast MRI: in vivo validation in the porcine aorta.

Artery wall motion and strain play important roles in vascular remodeling and may be important in the pathogenesis of vascular disease. In vivo observations of circumferentially nonuniform wall motion in the human aorta suggest that nonuniform strain may contribute to the localization of vascular pathology. A velocity-based method to investigate circumferential strain variations was previously developed and validated in vitro; the current study was undertaken to determine whether accurate displacement and strain fields can be calculated from velocity data acquired in vivo. Wall velocities in the porcine thoracic aorta were quantified with PC-MRI and an implanted coil and were then time-integrated to compute wall displacement trajectories and cyclic strain. Displacement trajectories were consistent with observed aortic wall motion and with the displacements of markers in the aortic wall. The mean difference between velocity-based and marker-based trajectory points was 0.1 mm, relative to an average pixel size of 0.4 mm. Propagation of error analyses based on the precision of the computed displacements were used to demonstrate that 10% strain results in a standard deviation of 3.6%. This study demonstrates that it is feasible to accurately quantify strain from low wall velocities in vivo and that the porcine thoracic aorta does not deform uniformly.

Algorithms↗

An inverse-geometry volumetric CT system with a large-area scanned source: a feasibility study.

We propose an inverse-geometry volumetric CT system for acquiring a 15-cm volume in one rotation with negligible cone-beam artifacts. The system uses a large-area scanned source and a smaller detector array. This note describes two feasibility investigations. The first examines data sufficiency in the transverse planes. The second predicts the signal-to-noise ratio (SNR) compared to a conventional scanner. Results showed sufficient sampling of the full volume in less than 0.5 s and, when compared to a conventional scanner operating at 24 kW with a 0.5-s voxel illumination time (e.g., 0.5-s gantry rotation and pitch of one), predicted a relative SNR of 76%.

Algorithms↗

Steady-state free precession MR imaging: improved myocardial tag persistence and signal-to-noise ratio for analysis of myocardial motion.

Tagging with balanced steady-state free-precession (SSFP) magnetic resonance (MR) imaging by using a steady-state storage scheme for myocardial motion analysis was evaluated. Signal-to-noise ratio (SNR), blood-tissue contrast, and tag persistence in volunteers and phantoms showed improved performance of SSFP imaging with tagging compared with that of radiofrequency spoiled gradient-echo (SPGR) MR imaging with tagging. Choice of flip angle with SSFP imaging involved a trade-off among SNR, blood-tissue contrast, and tag persistence. Increased SNR and tag persistence can be achieved simultaneously with SSFP imaging compared with SPGR tagging methods. As a result, the proposed technique may be useful for analysis of diastolic ventricular function.

Adult↗

Circular tomosynthesis: potential in imaging of breast and upper cervical spine--preliminary phantom and in vitro study.

Phantom and in vitro studies were performed to evaluate the potential application of digital circular tomosynthesis in imaging of the breast and upper cervical spine. A prototype volumetric x-ray system was used to image a mammographic phantom, a fresh mastectomy specimen, and a head phantom containing the upper cervical spine. Results show that breast tissue visualization is improved by the ability to produce sectional images that blur overlying structures and yield three-dimensional information about calcification clusters. In upper cervical spine imaging, digital circular tomosynthesis effectively blurs overlying jaw and skull structures so that C1 and C2 can be visualized in a standard anteroposterior view.

Cervical Vertebrae↗

Time-resolved three-dimensional phase-contrast MRI.

PURPOSE: To demonstrate the feasibility of a four-dimensional phase contrast (PC) technique that permits spatial and temporal coverage of an entire three-dimensional volume, to quantitatively validate its accuracy against an established time resolved two-dimensional PC technique to explore advantages of the approach with regard to the four-dimensional nature of the data. MATERIALS AND METHODS: Time-resolved, three-dimensional anatomical images were generated simultaneously with registered three-directional velocity vector fields. Improvements compared to prior methods include retrospectively gated and respiratory compensated image acquisition, interleaved flow encoding with freely selectable velocity encoding (venc) along each spatial direction, and flexible trade-off between temporal resolution and total acquisition time. RESULTS: The implementation was validated against established two-dimensional PC techniques using a well-defined phantom, and successfully applied in volunteer and patient examinations. Human studies were performed after contrast administration in order to compensate for loss of in-flow enhancement in the four-dimensional approach. CONCLUSION: Advantages of the four-dimensional approach include the complete spatial and temporal coverage of the cardiovascular region of interest and the ability to obtain high spatial resolution in all three dimensions with higher signal-to-noise ratio compared to two-dimensional methods at the same resolution. In addition, the four-dimensional nature of the data offers a variety of image processing options, such as magnitude and velocity multi-planar reformation, three-directional vector field plots, and velocity profiles mapped onto selected planes of interest.

Contrast Media↗

Fast algorithms for GS-model-based image reconstruction in data-sharing Fourier imaging.

Many imaging experiments involve acquiring a time series of images. To improve imaging speed, several "data-sharing" methods have been proposed, which collect one (or a few) high-resolution reference(s) and a sequence of reduced data sets. In image reconstruction, two methods, known as "Keyhole" and reduced-encoding imaging by generalized-series reconstruction (RIGR), have been used. Keyhole fills in the unmeasured high-frequency data simply with those from the reference data set(s), whereas RIGR recovers the unmeasured data using a generalized series (GS) model, of which the basis functions are constructed based on the reference image(s). This correspondence presents a fast algorithm (and two extensions) for GS-based image reconstruction. The proposed algorithms have the same computational complexity as the Keyhole algorithm, but are more capable of capturing high-resolution dynamic signal changes.

Algorithms↗

Rapid MR imaging of articular cartilage with steady-state free precession and multipoint fat-water separation.

OBJECTIVE: To obtain high-quality high-resolution images of articular cartilage with reduced imaging time, we combined a novel technique of generalized multipoint fat-water separation with three-dimensional (3D) steady-state free precession (SSFP) imaging. SUBJECTS AND METHODS: The cartilage of 10 knees in five healthy volunteers was imaged with 3D SSFP imaging and a multipoint fat-water separation method capable of separating fat and water with short TE increments. Fat-saturated 3D spoiled gradient-echo (SPGR) images were obtained for comparison. RESULTS: High-quality images of the knee with excellent fat-water separation were obtained with 3D SSFP imaging. Total imaging time required was 58% less than that required for 3D SPGR imaging with a comparable cartilage signal-to-noise ratio and spatial resolution. Unlike 3D SPGR images, 3D SSFP images exhibited bright synovial fluid, providing a potential arthrographic effect. CONCLUSION: High-quality high-resolution images of articular cartilage with improved fat-water separation, bright synovial fluid, and markedly reduced acquisition times can be obtained with 3D SSFP imaging combined with a fat-water separation technique.

Adult↗

Measurement of vessel wall strain using cine phase contrast MRI.

PURPOSE: To determine the feasibility of using magnetic resonance imaging (MRI) to non-invasively measure strain in the aortic wall. MATERIALS AND METHODS: Cine phase contrast MRI was used to measure the velocity of the aortic wall and calculate changes in circumferential strain over the cardiac cycle. A deformable vessel phantom was used for initial testing and in vitro validation. Ultrasonic sonomicrometer crystals were attached to the vessel wall and used as a gold standard. RESULTS: In the in vitro validation, MRI-calculated wall displacements were within 0.02 mm of the sonomicrometer measurements when maximal displacement was 0.28 mm. The measured maximum strain in vitro was 0.02. The in vivo results were on the same order as prior results using ultrasound echo-tracking. CONCLUSION: Results of in vivo studies and measurement of cyclic strain in human thoracic and abdominal aortas demonstrate the feasibility of the technique.

Aorta↗

New approach to 3D time-resolved angiography.

TRICKS is an acquisition and reconstruction method capable of generating 3D time-resolved angiograms. Arguably, the main problem with TRICKS is the way it handles the outer regions of the k-space matrix, leading to artifacts at the edges of blood vessels. An alternative to the data- processing stage of TRICKS, designed to better represent edges and small vessels, is presented here. A weakness of the new approach is an increased sensitivity to motion compared to TRICKS. Since this method can use the same data as TRICKS, a hybrid reconstruction method could conceivably be developed where the advantages of both approaches are combined. Magn Reson Med 47:1022-1025, 2002.

Feasibility Studies↗

In vivo validation of numerical prediction of blood flow in arterial bypass grafts.

In planning operations for patients with cardiovascular disease, vascular surgeons rely on their training, past experiences with patients with similar conditions, and diagnostic imaging data. However, variability in patient anatomy and physiology makes it difficult to quantitatively predict the surgical outcome for a specific patient a priori. We have developed a simulation-based medical planning system that utilizes three-dimensional finite-element analysis methods and patient-specific anatomic and physiologic information to predict changes in blood flow resulting from surgical bypass procedures. In order to apply these computational methods, they must be validated against direct experimental measurements. In this study, we compared in vivo flow measurements obtained using magnetic resonance imaging techniques to calculated flow values predicted using our analysis methods in thoraco-thoraco aortic bypass procedures in eight pigs. Predicted average flow rates and flow rate waveforms were compared for two locations. The predicted and measured waveforms had similar shapes and amplitudes, while flow distribution predictions were within 10.6% of the experimental data. The average absolute difference in the bypass-to-inlet blood flow ratio was 5.4 +/- 2.8%. For the aorta-to-inlet blood flow ratio, the average absolute difference was 6.0 +/- 3.3%.

Anastomosis, Surgical↗

Quantification of vessel wall cyclic strain using cine phase contrast magnetic resonance imaging.

In vivo quantification of vessel wall cyclic strain has important applications in physiology and disease research and the design of intravascular devices. We describe a method to calculate vessel wall strain from cine PC-MRI velocity data. Forward-backward time integration is used to calculate displacement fields from the velocities, and cyclic Green-Lagrange strain is computed in segments defined by the displacements. The method was validated using a combination of in vitro cine PC-MRI and marker tracking studies. Phantom experiments demonstrated that wall displacements and strain could be calculated accurately from PC-MRI velocity data, with a mean displacement difference of 0.20 +/- 0.16 mm (pixel size 0.39 mm) and a mean strain difference of 0.01 (strain extent 0.20). A propagation of error analysis defined the relationship between the standard deviations in displacements and strain based on original segment length and strain magnitude. Based on the measured displacement standard deviation, strain standard deviations were calculated to be 0.015 (validation segment length) and 0.045 (typical segment length). To verify the feasibility of using this method in vivo, cyclic strain was calculated in the thoracic aorta of a normal human subject. Results demonstrated nonuniform deformation and circumferential variation in cyclic strain, with a peak average strain of 0.08 +/- 0.11.

Algorithms↗

Noninvasive measurement of extraction fraction and single-kidney glomerular filtration rate with MR imaging in swine with surgically created renal arterial stenoses.

PURPOSE: To test whether magnetic resonance (MR) imaging enables accurate measurement of extraction fraction (EF) in swine with unilateral renal ischemia and to evaluate effects of renal arterial stenosis on EF and single-kidney glomerular filtration rate. MATERIALS AND METHODS: High-grade unilateral renal arterial stenoses were surgically created in eight pigs. Direct measurements of renal venous and arterial inulin concentration provided reference standard estimates of single-kidney EF. Pigs were imaged with a 1.5-T imager to estimate EF, renal blood flow, and glomerular filtration rate. A breath-hold inversion-recovery spiral sequence was used to measure T1 of blood in the infrarenal inferior vena cava and renal veins after intravenous administration of gadopentetate dimeglumine, and these data were used to calculate EF. Cine-phase contrast material-enhanced imaging of the renal arteries provided quantitative renal blood flow measurements. Bilateral single-kidney glomerular filtration rate was then determined: glomerular filtration rate = renal blood flow x (1 - hematocrit level) x EF. RESULTS: A statistically significant linear correlation was found between EF, as determined with MR imaging, and inulin (r = 0.77). As compared with kidneys without renal arterial stenosis, kidneys with renal arterial stenosis showed 50% (0.14/0.28) EF reduction (P <.01) and 59% glomerular filtration rate reduction (P <.01). CONCLUSION: MR imaging shows promise for in vivo measurement of EF and glomerular filtration rate, which may be useful in assessing the clinical importance of renal arterial stenosis.

Animals↗

Time-resolved 3-dimensional velocity mapping in the thoracic aorta: visualization of 3-directional blood flow patterns in healthy volunteers and patients.

OBJECTIVE: An analysis of thoracic aortic blood flow in normal subjects and patients with aortic pathologic findings is presented. Various visualization tools were used to analyze blood flow patterns within a single 3-component velocity volumetric acquisition of the entire thoracic aorta METHODS: Time-resolved, 3-dimensional phase-contrast magnetic resonance imaging (3D CINE PC MRI) was employed to obtain complete spatial and temporal coverage of the entire thoracic aorta combined with spatially registered 3-directional pulsatile blood flow velocities. Three-dimensional visualization tools, including time-resolved velocity vector fields reformatted to arbitrary 2-dimensional cut planes, 3D streamlines, and time-resolved 3D particle traces, were applied in a study with 10 normal volunteers. Results from 4 patient examinations with similar scan prescriptions to those of the volunteer scans are presented to illustrate flow features associated with common pathologic findings in the thoracic aorta. RESULTS: Previously reported blood flow patterns in the thoracic aorta, including right-handed helical outflow, late systolic retrograde flow, and accelerated passage through the aortic valve plane, were visualized in all volunteers. The effects of thoracic aortic disease on spatial and temporal blood flow patterns are illustrated in clinical cases, including ascending aortic aneurysms, aortic regurgitation, and aortic dissection. CONCLUSION: Time-resolved 3D velocity mapping was successfully applied in a study of 10 healthy volunteers and 4 patients with documented aortic pathologic findings and has proven to be a reliable tool for analysis and visualization of normal characteristic as well as pathologic flow features within the entire thoracic aorta.

Adult↗