Search PubMed⌕ Search

Biomedical subjects

Nikolaos A Papadopulos

Publications and source records attributed to Nikolaos A Papadopulos.

14 recordsLinked to original sources

Comparison between breast volume measurement using 3D surface imaging and classical techniques.

Quantification of the complex breast region can be helpful in breast surgery, which is shaped by subjective influences. However, there is no generally recognized method for breast volume calculation. Three-dimensional (3D) body surface imaging represents a new alternative for breast volume computation. The aim of this work was to compare breast volume calculation with 3D scanning and three classic methods, focusing on relative advantages, disadvantages, and reproducibility. Repeated breast volume calculations of both breasts in six patients (n=12) were performed using a 3D laser scanner, nuclear magnetic resonance imaging (MRI), thermoplastic castings, and anthropomorphic measurements. Mean volumes (cc) and mean measurement deviations were calculated, and regression analyses were performed. MRI showed the highest measurement precision, with a mean deviation (expressed as a percentage of mean breast volume) of 1.56+/-0.52% compared with 2.27+/-0.99% for the 3D scanner, 7.97+/-3.53% for thermoplastic castings, and 6.26+/-1.56% for the anthropomorphic measurements. Breast volume calculations using MRI showed the best agreement with 3D scanning measurement (r=0.990), followed by anthropomorphic measurement (r=0.947), and thermoplastic castings (r=0.727). Compared with three classical methods of breast volume calculation, 3D scanning provides acceptable accuracy for breast volume measurements, better spatial interpretation of the anatomical area to be operated on (due to lack of chest deformation), non-invasiveness, and good patient tolerance. After this preliminary study and further development, we believe that 3D body surface scanning could provide better preoperative planning and postoperative control in everyday clinical practice.

Adult↗

Amnion cells engineering: a new perspective in fetal membrane healing after intrauterine surgery?

In this study we aimed to set up an in vitro culture of the rabbit amnion in order to support in vivo fetal membrane healing capacity following fetoscopy. Fetal membranes were collected from a mid-gestational rabbit, and cultured on collagen support material for 14 days. 34 rabbits at 22-23 days gestational age (GA) underwent fetoscopy. The entry site was randomly allocated to 4 closure technique study groups: group I, human amnion membrane (n = 23); group II, collagen foil (n = 16); group III, collagen plug (n = 19), and group IV, collagen plug with cultured amnion cells (n = 19). In all groups membrane access sites were additionally sealed with fibrin sealant, and the myometrium was closed with sutures. Fetal survival, amnion membrane integrity, and the presence of amniotic fluid were evaluated at 30 days GA. Cultures showed good survival in the collagen support material. Increased cellularity, survival and proliferations were observed. The amnion at the access site resealed in 58-64% of cases in groups II-IV, but none of the tested techniques was significantly better than the other. Histological examination indirectly revealed the anatomic repair of the membranes, since no entrapment of the membranes could be demonstrated in the myometrial wound.

Amnion↗

Optimization of 3-dimensional imaging of the breast region with 3-dimensional laser scanners.

The anatomic conditions of the female breast require imaging the breast region 3-dimensionally in a normal standing position for quality assurance and for surgery planning or surgery simulation. The goal of this work was to optimize the imaging technology for the mammary region with a 3-dimensional (3D) laser scanner, to evaluate the precision and accuracy of the method, and to allow optimum data reproducibility. Avoiding the influence of biotic factors, such as mobility, we tested the most favorable imaging technology on dummy models for scanner-related factors such as the scanner position in comparison with the torso and the number of scanners and single shots. The influence of different factors of the breast region, such as different breast shapes or premarking of anatomic landmarks, was also first investigated on dummies. The findings from the dummy models were then compared with investigations on test persons, and the accuracy of measurements on the virtual models was compared with a coincidence analysis of the manually measured values. The best precision and accuracy of breast region measurements were achieved when landmarks were marked before taking the shots and when shots at 30 degrees left and 30 degrees right, relative to the sagittal line, were taken with 2 connected scanners mounted with a +10-degree upward angle. However, the precision of the measurements on test persons was significantly lower than those measured on dummies. Our findings show that the correct settings for 3D imaging of the breast region with a laser scanner can achieve an acceptable degree of accuracy and reproducibility.

Breast↗

New aspects of breast volume measurement using 3-dimensional surface imaging.

Precise and objective calculation of breast volume is helpful to evaluate the aesthetic result of breast surgery, but traditional methods are unsatisfactory. Three-dimensional (3D) scanning of the body surface allows reproducible and objective assessment of the complex breast region but requires further investigation before clinical application. The main goal of this study was to investigate the precision and accuracy of breast volume measurement using 3D body scanning. Five independent observers standardized the 3D scanning method using 2 dummy models (n = 200) and examined its applicability with 6 test subjects and 10 clinical patients (n = 2220). Breast volume measurements obtained with the 3D-scanner technology were compared with reference measurements obtained from test subjects through nuclear magnetic resonance imaging. The mean deviation of the breast volume measurements of 1 test subject by all observers, expressed as percentage of volume, was 2.86 +/- 0.98, significantly higher than the deviation for the dummy models, 1.65 +/- 0.42 (P < 0.001). With respect to all clinical patients, the mean measurement precision obtained preoperatively was less precise than that obtained postoperatively (3.31 +/- 1.02 versus 1.66 +/- 0.49, respectively). Interobserver differences in measurement precision were not statistically significant. The mean breast volumes obtained by nuclear magnetic resonance imaging (441.42 +/- 137.05 mL) and 3D scanning (452.51 +/- 141.88 mL) significantly correlated (r = 0.995, P < 0.001). Breast volume measurement with 3D surface imaging represents a sufficiently precise and accurate method to guarantee objective and exact recording.

Breast↗

Three-dimensional cephalometric evaluation of maxillary growth following in utero repair of cleft lip and alveolar-like defects in the mid-gestational sheep model.

OBJECTIVE: To evaluate maxillary growth following in utero repair of surgically created cleft lip and alveolar (CLA)-like defects by means of three-dimensional (3D) computer tomographic (CT) cephalometric analysis in the mid-gestational sheep model. METHODS: In 12 sheep fetuses a unilateral CLA-like defect was created in utero (untreated control group: 4 fetuses). Four different bone grafts were used for the alveolar defect closure. After euthanasia, CT scans of the skulls of the fetuses, 3D reconstructions, and a 3D-CT cephalometric analysis were performed. RESULTS: The comparisons between the operated and nonoperated skull sides as well as of the maxillary asymmetry among the experimental groups revealed no statistically significant differences of the 12 variables used. CONCLUSIONS: None of the surgical approaches used for the in utero correction of CLA-like defects seem to affect significantly postsurgical maxillary growth; however, when bone graft healing takes place, a tendency for almost normal maxillary growth can be observed.

Alveolar Process↗

Three-dimensional fetal cephalometry: an evaluation of the reliability of cephalometric measurements based on three-dimensional CT reconstructions and on dry skulls of sheep fetuses.

AIM: To develop a 3D CT cephalometric analysis for maxillary growth evaluation of sheep fetuses operated in utero, and to evaluate the reliability of this analysis by comparing it with a direct cephalometric analysis on dry skulls. MATERIAL AND METHODS: Five skulls of operated sheep fetuses were used, which after preparation were CT scanned and a 3D reconstruction was performed. A cephalometric analysis was performed directly on the dry skulls as well as on the reconstructed 3D CT images. In total, 56 linear distances were measured. In order to access the error of the method, the procedure was repeated after a 2 week interval. RESULTS: The comparison between the direct cephalometric and the 3D CT analysis revealed that only 5 variables were significantly different. The evaluation of the error of method revealed that 7 variables of the direct cephalometric analysis and none of the 3D CT analysis differed significantly. CONCLUSIONS: According to the results of this study, it can be concluded that a cephalometric analysis on 3D CT reconstructed images of the skulls includes fewer identification errors and seems to be an accurate and reliable method that could be regarded at least as equivalent to conventional cephalometry.

Animals↗

Intrauterine autogenous foetal bone transplantation for the repair of cleft-like defects in the mid-gestational sheep model.

AIM: The success of intrauterine surgery in treating non-life-threatening malformations such as myelomeningocoele, has also renewed strong interest in using this technique for treating craniofacial malformations. Nevertheless, the only experimental cleft-like defect models known, are those concerning wound healing of soft tissues. MATERIAL AND METHODS: Attempts were made to repair artificial cleft-like defects including transplantation of 11 autogenous foetal bone grafts from the iliac crest or ulna, and were randomly assigned to three study groups, using the mid-gestational sheep model. In a 4th study group, lyophilized collagen, a bone-regenerating bioresorbable implant material, was used to fill the alveolar defect. RESULTS: In all groups, there was a slight degree of asymmetry and thinning of the lip. Radiological studies demonstrated a variable degree of abnormality of the maxilla, ranging from none to a mild deviation. Three-dimensional computer tomography, two-dimensional maximal intensity projection findings, and histological analysis confirmed bony healing of the alveolar cleft-like defect. DISCUSSION/CONCLUSION: Intrauterine autogenous foetal bone transplantation for the repair of cleft-like defects in the sheep is feasible. This is a reliable and valuable model toward a possible clinical application for intrauterine treatment of clefts.

Absorbable Implants↗

Clinical outcome and patients' satisfaction after simultaneous bilateral breast reconstruction with free transverse rectus abdominis muscle (TRAM) flap.

In the study presented, the long-term outcome and satisfaction of 34 patients who underwent simultaneous bilateral breast reconstruction with a free transverse rectus abdominis muscle (TRAM) flap between 1988 and 2001 were assessed. Flap complications affected 13 of 68 flaps (19.1%). Anastomosis revision was needed in 6 cases (8.8%), the salvage rate being 50%. The rates of total and partial flap loss were 4.4% and 1.5%, respectively. Bilateral flap loss did not occur. Four patients developed donor site complications (11.7%), with wound healing problems being the most common (5.8%). Most patients were satisfied with their decision to have had breast reconstruction with free TRAM, 91% would choose the same operation again, and 91% would recommend this procedure to other patients. Of the operated patients, 20.8% felt an improvement in their sexual life; more patients, however, reported an improvement concerning their social life (37.5%) and life in general (50%).

Adult↗

Three-dimensional craniofacial reconstruction imaging.

This review article aims to describe and discuss the imaging techniques most commonly used in medicine and dentistry to obtain three-dimensional images of the craniofacial complex. Three-dimensional imaging techniques provide extensive possibilities for the detailed and precise analysis of the whole craniofacial complex, for virtual (on-screen) simulation and real simulation of orthognathic surgery cases on biomodels before treatment, as well as for the detailed evaluation of the effects of treatment. Laser scanning in combination with the stereolithographic biomodeling seems to be a very promising combination for three-dimensional imaging, although there is still considerable room for improvement. Constant efforts should be made in the direction of developing and enhancing the existing techniques as well as exploring the potential for developing new methods based on emerging sectors of technology.

Cephalometry↗

Donor site morbidity after harvest of free osteofasciocutaneous fibular flaps with an extended skin island.

Since 1993, a total of 41 free osteofasciocutaneous fibular flaps with an extended skin island (average dimensions, 16.9 cm long [range, 12-22 cm] x 10.7 cm wide [range, -16 cm], or 180.8 cm [range, 112-352 cm ]) have been used in by the authors in various clinical applications. To evaluate donor site morbidity, the 41 patients involved were asked to answer a questionnaire and to present themselves for clinical and radiological examination. The subjective findings reported by these patients, and the examinations, showed that donor site morbidity was moderate. Apart from some occurrence of mild edema and pain, as well as modest motor weakness of the great toe, and deficiency of distal nervous segments, only 7 patients were found to have a slightly positive anterior drawer of the talus (anterior subluxation of the talus), but no instability. In conclusion, donor site morbidity after harvest of osteofasciocutaneous fibular flaps for different clinical indications, where extended skin islands were needed, is moderate.

Adult↗

Long-term fate of the bony component in neophallus construction with free osteofasciocutaneous forearm or fibula flap in 18 female-to-male transsexuals.

Female-to-male transsexuals have been operated on in the authors' department since 1975. Between 1981 and 1995, 46 patients underwent neophallus construction with a free osteofasciocutaneous forearm or fibula flap. The bony part of these flaps is embedded in tissue with excellent blood circulation, has no contact with the skeleton, and is free of mechanical stress. To evaluate the long-term fate of the bony component of these flaps, the authors examined 18 of the 46 patients (39.1 percent) who had received a neophallus by means of one of these methods (12 with forearm and six with fibula flap) and who were willing to participate in the updating of the results of the previous two decades; this represented a follow-up of 5 to 112 months postoperatively (average, 27.4 months). The following investigations were undertaken: clinical and radiologic examination, bone scintigraphy, magnetic resonance imaging, and histologic examination of the neophallus bony component. In all patients, the clinical examination showed no significant variations in the shape and rigidity of the neophallus bone. The radiologic examination showed a compact bone structure, and the magnetic resonance imaging proved the vitality of the neophallus in all patients, with no significant changes over time. Bone scintigraphy did not prove to be useful in determining the long-term fate of the neophallic bony component. Histologically, subperiosteal neoformation of fibrous bone was shown, whereas the lamellar cortical bone was predominantly avital. The results of this study reveal the vitality of the bony component in neophallus construction with free osteofasciocutaneous flaps. Even 112 months after the procedure, it provided sufficient stiffness for sexual intercourse. This continuing adequate rigidity of the bony component, in addition to the well-known advantages of the free osteofasciocutaneous flap, is further evidence of its usefulness in neophallus construction.

Female↗