Search PubMed⌕ Search

Biomedical subjects

Nico R Mollet

Publications and source records attributed to Nico R Mollet.

34 records · Page 2Linked to original sources

Value of preprocedure multislice computed tomographic coronary angiography to predict the outcome of percutaneous recanalization of chronic total occlusions.

We performed multislice computed tomographic coronary angiography in 45 patients who had chronic total occlusions and were scheduled for percutaneous recanalization. Multivariate analysis identified a blunt stump (by conventional angiography), occlusion length >15 mm, and severe calcification (by multislice computed tomographic coronary angiography) as independent predictors of procedural failure.

Coronary Angiography↗

Improved diagnostic accuracy with 16-row multi-slice computed tomography coronary angiography.

OBJECTIVES: We sought to compare the diagnostic value of multi-slice computed tomography (MSCT) coronary angiography (CA) to detect significant stenoses (> or =50% lumen diameter reduction) with that of invasive CA. BACKGROUND: The latest 16-row MSCT scanner has a faster rotation time (375 ms) and permits scanning with a higher X-ray tube current (500 to 600 mA) during MSCT CA when compared with previous scanners. METHODS: We studied 51 patients (37 men, mean age 58.9 +/- 10.0 years) with stable angina or atypical chest pain. Patients with pre-scan heart rates > or =70 beats/min received oral beta-blockade. The heart was scanned after intravenous injection of 100 ml contrast (iodine content, 400 mg/ml). Mean scan time was 18.9 +/- 1.0 s. The MSCT scans were analyzed by two observers unaware of the results of invasive angiography, and all available coronary branches > or =2 mm were included. RESULTS: Invasive CA demonstrated normal arteries in 16% (8 of 51), non-significant disease in 21% (11 of 51), single-vessel disease in 37% (19 of 51), and multi-vessel disease in 26% (13 of 51) of patients. There were 64 significant lesions. Sensitivity, specificity, and positive and negative predictive values for detection of significant lesions on a segment-based analysis were 95% (61 of 64, 95% confidence interval [CI] 86 to 99), 98% (537 of 546, 95% CI 96 to 99), 87% (61 of 70, 95% CI 76 to 98), and 99% (537 of 540, 95% CI 98 to 99), respectively. All patients with angiographically normal coronary arteries or significant lesions were correctly identified. Three of 11 patients with <50% lesions were incorrectly classified as having single-vessel disease. CONCLUSIONS: The 16-row MSCT CA reliably detects significant coronary stenoses in patients with atypical chest pain or stable angina pectoris.

Coronary Angiography↗

Multislice CT coronary angiography: how to do it and what is the current clinical performance?

The introduction of multislice computed tomography (MSCT) has allowed non-invasive coronary angiography. Although widely applied, extensive information on technical details of the technique is lacking. This survey offers detailed information on patient preparation, data acquisition, reconstruction and interpretation. In addition, a summary of the available studies using MSCT for non-invasive angiography is provided. Based on pooled analysis of direct comparisons between MSCT and invasive angiography, the weighted mean sensitivity and specificity of current 16-slice MSCT for the detection of coronary artery disease are 88% and 96%, respectively. At present, the technique is particularly well suited for reliable exclusion of coronary artery disease. It is important to emphasise that MSCT only provides anatomical images, visualising the presence of atherosclerosis; information on the haemodynamic significance of these lesions (i.e. ischaemia) cannot be derived.

Clinical Trials as Topic↗

Intravenous contrast material administration at helical 16-detector row CT coronary angiography: effect of iodine concentration on vascular attenuation.

The institutional review board approved this study, and all patients gave written informed consent. One hundred twenty-five patients scheduled to undergo retrospectively electrocardiographically gated 16-detector row computed tomographic coronary angiography were prospectively randomized into the following five groups with respect to the intravenous administration of a 140-mL bolus of contrast material at 4 mL/sec: group 1 (iohexol [300 mg of iodine per milliliter]), group 2 (iodixanol [320 mg I/mL]), group 3 (iohexol [350 mg I/mL]), group 4 (iomeprol [350 mg I/mL]), and group 5 (iomeprol [400 mg I/mL]). Attenuation was measured in the descending aorta and coronary arteries. One-way analysis of variance was used to compare groups. Mean attenuation values in the descending aorta were significantly (P < .05) lower in group 1 and higher in group 5 compared with the mean values in the other three groups. The same pattern was observed in the coronary arteries. Contrast materials with higher iodine concentrations yield significantly higher attenuation in the descending aorta and coronary arteries.

Adult↗

Influence of increasing convolution kernel filtering on plaque imaging with multislice CT using an ex-vivo model of coronary angiography.

PURPOSE: To assess the variability in attenuation of coronary plaques with multislice CT-angiography (MSCT-CA) in an ex-vivo model with varying convolution kernels. MATERIALS AND METHODS: MSCT-CA (Sensation 16, Siemens) was performed in three ex-vivo left coronary arteries after instillation of contrast material solution (Iomeprol 400 mgI/ml, dilution: 1/80). The specimens were placed in oil to simulate epicardial fat. Scan parameters: slices 16/0.75 mm, rotation time 375 ms, feed/rotation 3.0 mm, mAs 500, slice thickness 1 mm, and FOV 50 mm. Datasets were reconstructed using 4 different kernels (B30f-smooth, B36f-medium smooth, B46f-medium, and B60f-sharp). Each scan was scored for the presence of plaques. Once a plaque was detected, the operator performed attenuation measurements (HU) in coronary lumen, oil, calcified and soft plaque tissue using the same settings in all datasets. The results were compared with T-test and correlated with Pearson's test. RESULTS: Overall, 464 measurements were performed. Significant differences (p<0.05) were found for the mean attenuation of lumen (B30f/B36f, B30f/B60f, B36f/B46f, B36f/B60f, and B46f/B60f), oil (B30f/B36f, B30f/B46f, B30f/B60f, B36f/B46f, and B46f/B60f), calcium (all kernels), and plaque (B30f/B36f, B30f/B46f, B30f/B60f, and B46f/B60f) using 4 different kernels. The attenuation values (mean+/-SD) within the lumen (246+/-6, 215+/-13, 248+/-5, and 270+/-7), oil (-123+/-3, -127+/-1, -121+/-6, and -127+/-4), calcified plaque tissue (703+/-334, 739+/-364, 817+/-381, and 1181+/-503), and soft plaque tissue (134+/-56, 111+/-49, 120+/-56, and 102+/-41) showed high correlation (p<0.001) when attenuation of all structures were compared in different kernels. CONCLUSIONS: Use of sharper convolution kernels significantly increases the attenuation of the calcium within coronary plaques and reduces the attenuation of soft plaque tissue.

Aged↗

Multislice spiral computed tomography coronary angiography in patients with stable angina pectoris.

OBJECTIVES: This study was designed to prospectively evaluate the diagnostic performance of multislice spiral computed tomography (MSCT) coronary angiography for the detection of significant lesions in all segments of the coronary tree potentially suitable for revascularization. BACKGROUND: Noninvasive MSCT coronary angiography is a promising coronary imaging technique. METHODS: Sixteen-row MSCT coronary angiography was performed in 128 patients (89% men, mean age 58.9 +/- 11.7 years) in sinus rhythm with stable angina pectoris scheduled for conventional coronary angiography. Sixty percent (77 of 128) of patients received pre-scan oral beta-blockers, resulting in a mean heart rate of 57.7 +/- 7.7 beats/min. The diagnostic performance of MSCT for detection of significant lesions (> or =50% diameter reduction) was compared with that of quantitative coronary angiography (QCA). RESULTS: The sensitivity of MSCT for detection of significant lesions was 92% (216 of 234, 95% confidence interval [CI]: 88 to 95). Specificity was 95% (1,092 of 1,150, 95% CI: 93 to 96), positive predictive value 79% (216 of 274, 95% CI: 73 to 88), and negative predictive value 98% (1,092 of 1,110, 95% CI: 97 to 99). Two > or =50% lesions were missed because of motion artifacts and two because of severe coronary calcifications. The rest (78%, 14 of 18) were detected but incorrectly classified as <50% obstructions. All patients with and 86% (18 of 21) of patients without significant lesions on QCA were correctly classified by MSCT. All patients with significant left main disease or total occlusions were correctly identified on MSCT. CONCLUSIONS: Sixteen-row MSCT coronary angiography permits reliable detection of significant obstructive coronary artery disease in patients with stable angina in sinus rhythm.

Aged↗

MRI and CT revealing carcinoid heart disease.

Carcinoid heart disease is a frequent complication of the carcinoid syndrome, usually presenting as right-sided valvular heart disease. Although the diagnosis is most often made with cardiac ultrasound, MRI and CT are valuable techniques for diagnosing carcinoid heart disease.

Aged↗

MRI and CT revealing carcinoid heart disease.

Carcinoid heart disease is a frequent complication of the carcinoid syndrome, usually presenting as right-sided valvular heart disease. Although the diagnosis is most often made with cardiac ultrasound, MRI and CT are valuable techniques for diagnosing carcinoid heart disease.

Aged↗

Visualization of ventricular thrombi with contrast-enhanced magnetic resonance imaging in patients with ischemic heart disease.

BACKGROUND: Ventricular thrombus formation is a frequent and potentially dangerous complication in patients with ischemic heart disease. Although transthoracic echocardiography (TTE) is generally used as diagnostic technique, we explored the role of contrast-enhanced (CE)-MRI to detect ventricular thrombi. METHODS AND RESULTS: In 57 patients with acute myocardial infarction, chronic myocardial infarction, or ischemic cardiomyopathy, MRI was performed to evaluate ventricular function (CINE-MRI) and to depict presence of myocardial necrosis and/or scarring and no-reflow areas (CE-MRI). All studies were analyzed for concomitant ventricular thrombi. CE-MRI depicted 12 mural thrombi (3.1+/-2.9 cm3), located in left ventricular (LV) apex or adherent to anteroseptum, presenting as black, well-defined structures surrounded by bright contrast-enhanced blood. Thrombus formation on CE-MRI was related to larger end-diastolic volumes; lower ejection fractions; the region of delayed enhancement and lowest wall motion score, especially in left anterior descending coronary artery territory; and LV aneurysm formation. On CINE-MRI, thrombi were found in 6 patients. Nonvisualized thrombi were usually small (mean size 1.2+/-0.7 cm3). TTE depicted thrombi in 5. Nonvisualized lesions were most frequently located in LV apex and had a larger size than nonvisualized lesions on CINE-MRI (3.0+/-3.2 cm3). In 3 patients with suspected apical thrombus on TTE, MRI was normal. CONCLUSIONS: CE-MRI is not only an excellent technique to depict myocardial necrosis and scar tissue in patients with ischemic heart disease, but this study also suggests a better identification of LV thrombi than with presently used clinical imaging modalities, such as TTE.

Acute Disease↗

Introduction to coronary imaging with 64-slice computed tomography.

The aim of this article is to illustrate the main technical improvements in the last generation of 64-row CT scanners and the possible applications in coronary angiography. In particular, we describe the new physical components (X-ray tube-detectors system) and the general scan and reconstruction parameters. We then define the scan protocols for coronary angiography with the new generation of 64-row CT scanners to enable radiologists to perform a CT study on the basis of the diagnostic possibilities.

Algorithms↗

Impact of intravascular enhancement, heart rate, and calcium score on diagnostic accuracy in multislice computed tomography coronary angiography.

PURPOSE: To assess the effect of intravascular enhancement, heart rate, and calcium score on diagnostic accuracy in the detection of significant coronary artery stenosis using 16-row multislice computed tomography (MSCT). MATERIALS AND METHODS: One hundred patients (88 males; 59+/-11 years) with suspected coronary artery disease who had undergone conventional coronary angiography (CA) and MSCT-CA were retrospectively enrolled for the study. Patients underwent a MSCT-CA, with the following protocol: collimation 16x0.75 mm, gantry rotation time 420 ms, feed/rotation 2.8 mm, kV 120, mAs 400-500. The protocol for contrast material administration was 100 ml of Iodixanol 320 mgI/ml at 4 ml/s and the scan delay was defined with a bolus tracking technique. In all patients vascular enhancement was measured in the aortic root, and in the left and right coronary arteries. The average vascular enhancement was used to divide the population in two groups of 50 patients each, one with lower enhancement (Low), and one with higher enhancement (High). In the two groups diagnostic accuracy (per coronary segment) for the detection of significant stenosis (= or >50% lumen reduction) was evaluated in vessels = or >2 mm in diameter using quantitative CA as the reference standard. The differences in diagnostic accuracy were compared with a Chi-square test and a p<0.05 was considered significant. RESULTS: Of the total 1116 segments (= or >2 mm lumen diameter), 173 presented significant stenosis. The sensitivity and specificity for the assessment of significant stenosis were 89.4% and 93.3% vs 94.3% and 97.4% in the presence of increasing intravascular enhancement, 92.8% and 96.7% vs 91.1% and 93.9% in the presence of increasing heart rate, and 89.7% and 97.6% vs 93.3% and 92,8% in the presence of an increasing calcium score. CONCLUSIONS: Increasing intravascular enhancement significantly improves diagnostic accuracy in MSCT-CA. A higher heart rate lowers the specificity in the detection of significant obstructing lesions of the coronary artery. An increasing calcium score determines a lower specificity and a higher sensitivity.

Aged↗

Non-invasive evaluation of coronary calcium.

With the increasing diffusion of 4-row,16-row and 64-row multislice computed tomography scanners, widespread coronary calcium scoring has become possible in Europe. This relatively easy-to-perform test has a high sensitivity and low specificity for the detection of significant coronary artery stenosis, and may have an important role in the risk stratification for future coronary artery events in selected groups of patients, such as those immediately at risk. This study reviews the techniques available for coronary calcium scoring (electron beam tomography and multislice computed tomography) with their respective protocols, as well as their advantages and disadvantages. The methods for interpreting the results, the potential indications and the clinical applications of the techniques are also described.

Calcinosis↗