A machine for haemodialysing very small infants.

Babies weighing under 6 kg are difficult to dialyse, especially those as small as 1 kg. Peritoneal dialysis is easier than haemodialysis, but is not always possible, and clears molecules less efficiently. Two factors complicate haemodialysis. First, extracorporeal circuits are large relative to a baby's blood volume, necessitating priming with fresh or modified blood. Second, blood flow from infants' access vessels is disproportionately low (Poiseuille's law), causing inadequate dialysis, or clotting within the circuit. These problems are minimised by using single lumen access, a very small circuit, and a reservoir syringe to separate the sampling and dialyser blood flow rates. Its manual operation is tedious, so we developed a computer-controlled, pressure-monitored machine to run it, including adjusting the blood withdrawal rate from poorly sampling lines. We have dialysed four babies weighing 0.8-3.4 kg, with renal failure or metabolic disorders. The circuits did not require priming. Clearances of creatinine, urea, potassium, phosphate and ammonia were mean (SD) 0.54 (0.22) ml/min using one dialyser, and 0.98 (0.22) ml/min using two in parallel. Ammonia clearance in a 2.4 kg baby had a 9 h half-life. Ultrafiltration up to 45 ml/h was achieved easily. This device provided infants with immediate, effective and convenient haemodialysis, typically delivered for prolonged periods.

Body Size↗

Time-resolved optical mammography using a liquid coupled interface.

A method has been devised for generating three-dimensional optical images of the breast using a 32-channel time-resolved system and a liquid-coupled interface. The breast is placed in a hemispherical cup surrounded by sources and detectors, and the remaining space is filled with a fluid with tissue-like optical properties. This approach has three significant benefits. First, cups can accommodate a large range of breast sizes, enabling the entire volume of the breast to be sampled. Second, the coupling of the source and detector optics at the surface is constant and independent of the subject, enabling intensity measurements to be employed in the image reconstruction. Third, the external geometry of the reconstructed volume is known exactly. Images of isolated targets with contrasting absorbing and scattering properties have been acquired, and the performance of the system has been evaluated in terms of the contrast, spatial resolution, and localization accuracy. These parameters were strongly dependent on the location of the targets within the imaged volume. Preliminary images of a healthy human subject are also presented, which reveal subtle heterogeneity, particularly in the distribution of scatter. The ability to detect an absorbing target adjacent to the breast is also demonstrated.

Breast↗