Search PubMed⌕ Search

Biomedical subjects

Nicholas Gourtsoyiannis

Publications and source records attributed to Nicholas Gourtsoyiannis.

At least 19 recordsLinked to original sources

The pancreas in beta-thalassemia major: MR imaging features and correlation with iron stores and glucose disturbances.

The study aims at describing the MR features of pancreas in beta-thalassemia major, investigating the relations between MR findings and glucose disturbances and between hepatic and pancreatic siderosis. Signal intensity ratios of the pancreas and liver to right paraspinous muscle (P/M, L/M) were retrospectively assessed on abdominal MR imaging studies of 31 transfusion-dependent patients with beta-thalassemia major undergoing quantification of hepatic siderosis and 10 healthy controls, using T1- (120/4/90), intermediate in and out of phase - (120/2.7, 4/20), and T2*-(120/15/20) weighted GRE sequences. Using the signal drop of the liver and pancreas on opposed phase images, we recorded serum ferritin and results of oral glucose tolerance test (OGTT). Decreased L/M and P/M on at least the T2* sequence were noticed in 31/31 and 30/31 patients, respectively, but no correlation between P/M and L/M was found. Patients with pathologic OGTT displayed a higher degree of hepatic siderosis (p < 0.04) and signal drop of pancreas on opposed phase imaging (p < 0.025), implying fatty replacement of pancreas. P/M was neither correlated with glucose disturbances nor serum ferritin. Iron deposition in the pancreas cannot be predicted by the degree of hepatic siderosis in beta-thalassemia major. Fatty replacement of the pancreas is common and may be associated with glucose disturbances.

Adolescent↗

Thyroid dose from common head and neck CT examinations in children: is there an excess risk for thyroid cancer induction?

This study was conducted to estimate thyroid dose and the associated risk for thyroid cancer induction from common head and neck computed tomography (CT) examinations during childhood. The Monte Carlo N-particle transport code was employed to simulate the routine CT scanning of the brain, paranasal sinuses, inner ear and neck performed on sequential and/or spiral modes. The mean thyroid dose was calculated using mathematical phantoms representing a newborn infant and children of 1year, 5 years, 10 years and 15 years old. To verify Monte Carlo results, dose measurements were carried out on physical anthropomorphic phantoms using thermoluminescent dosemeters (TLDs). The scattered dose to thyroid from head CT examinations varied from 0.6 mGy to 8.7 mGy depending upon the scanned region, the pediatric patient's age and the acquisition mode used. Primary irradiation of the thyroid gland during CT of the neck resulted in an absorbed dose range of 15.2-52.0 mGy. The mean difference between Monte Carlo calculations and TLD measurements was 11.8%. Thyroid exposure to scattered radiation from head CT scanning is associated with a low but not negligible risk of cancer induction of 4-65 per million patients. Neck CT can result in an increased risk for development of thyroid malignancies up to 390 per million patients.

Adolescent↗

Dosimetric characteristics of a 16-slice computed tomography scanner.

Standard CT dose measurements were performed on a Siemens Sensation 16 scanner. CT dose indices, free-in-air (CTDI(F)) and weighted (CTDI(W)), were measured in all available axial and helical beam collimations of the head and body scanning modes. The effect of tube current, high voltage, rotation time, beam collimation and pitch on the CT doses was investigated. CT doses increased as a power function of high voltage. The kVp exponent n varied with beam collimation from 2.7 to 3.1 for CTDI(W), and from 2.4 to 2.6 for CTDI(F). Automatic change of the focal spot size increased radiation doses up to a factor of 1.18. Measured small-focus CTDI(W) values differed from those displayed at the console from -24 to 14%. Peripheral doses in the head phantom were higher compared to the body phantom by a factor of 1.5 to 2. Central doses are 2.7 to 4.1 times higher. Differences in beam collimation resulted in 50% variation in the CTDI(W) in the body phantom and 60% in the head phantom. In conclusion, our study has confirmed the great impact of technique factors and acquisition parameters on CT doses. The provided comprehensive dosimetric data will facilitate the dose-effective use of the scanner studied.

Computer Simulation↗

Scattered dose to thyroid from prophylactic cranial irradiation during childhood: a Monte Carlo study.

The purpose of this study was to estimate the scattered dose to thyroid from prophylactic cranial irradiation during childhood. The MCNP transport code and mathematical phantoms representing the average individual at ages 3, 5, 10, 15 and 18 years old were employed to simulate cranial radiotherapy using two lateral opposed fields. The mean radiation dose received by the thyroid gland was calculated. A 10 cm thick lead block placed on the patient's couch to shield the thyroid was simulated by MCNP code. The Monte Carlo model was validated by measuring the scattered dose to the unshielded and shielded thyroid using three different humanoid phantoms and thermoluminescense dosimetry. For a cranial dose of 18 Gy, the thyroid dose obtained by Monte Carlo calculations varied from 47 to 79 cGy depending upon the age of the child. Appropriate placement of the couch block resulted in a thyroid dose reduction by 39 to 54%. Thyroid dose values at all possible positions of the radiosensitive gland with respect to the inferior field edge at five different patient ages were found. The mean difference between Monte Carlo results and thyroid dose measurements was 9.6%.

Body Burden↗

Fluoroscopically assisted surgical treatments of spinal disorders: conceptus radiation doses and risks.

STUDY DESIGN: A series of anterior-posterior and lateral fluoroscopic exposures at 5 spinal levels were performed on anthropomorphic phantoms simulating the 3 trimesters of gestation. OBJECTIVES: To provide normalized data for the determination of conceptus dose specific to gestational stage and treated spinal level. To estimate the conceptus radiation dose and risk associated with typical fluoroscopically guided spinal treatments performed on the pregnant patient. SUMMARY OF BACKGROUND DATA: To our knowledge, there are no available data on conceptus doses and radiogenic risks resulting from fluoroscopically guided spinal surgery of the expectant mother. METHODS: Direct measurement of conceptus doses from simulated fluoroscopic projections involved in orthopedic surgery at different spinal levels for the 3 trimesters of gestation with use of anthropomorphic phantoms and thermoluminescent dosimetry. Estimation of conceptus radiation risks from a typical pedicle screw fixation and kyphoplasty procedure using the experimentally derived data. RESULTS: Conceptus doses from fluoroscopically guided spinal treatments are smaller than 4 mGy during all gestational stages, provided that the conceptus lies outside the primarily irradiated region. The associated risks of fatal cancer during childhood and congenital malformation on its progeny are at least 2 and 1500 times, respectively, lower than the spontaneous incidence rates. When the embryo is primarily irradiated, mean conceptus dose can be as high as 105 mGy from a nonoptimized exposure. At least 35 minutes of fluoroscopy are required for the induction of deterministic effects. CONCLUSIONS: Individual dose assessment is paramount in every pregnancy. Variations in fluoroscopy practices and gestational stage significantly affect fetal doses.

Computer Simulation↗

Radiation dose to laterally transposed ovaries during external beam radiotherapy for cervical cancer.

The purpose of this study was to estimate the radiation dose to laterally transposed ovaries from external beam radiotherapy for cervical cancer. Dose measurements were performed in a modified humanoid phantom using a 6 MV photon beam. The dependence of the ovarian dose upon the field size, the distance from the primary irradiation field and the presence of wedges or gonadal shielding was determined. For a tumor dose of 45 Gy, ovarian dose was 0.88-8.51 Gy depending on the field size employed and the location of the transposed ovary in respect to the treatment field. Positioning of 7 cm thick shielding reduced the dose to ovary by less than 19%. The use of wedges increased the ovarian dose by a factor up to 1.5. Accurate radiographic localization of the ovaries allows the use of the presented dosimetric results to obtain a reasonable prediction of the ovarian dose.

Female↗

Radiation dose and risk from fluoroscopically guided percutaneous transhepatic biliary procedures.

PURPOSE: To estimate radiation dose and associated risks after fluoroscopically guided percutaneous transhepatic biliary (PTB) drainage and stent implantation procedures. MATERIALS AND METHODS: Organ and effective doses, normalized to dose-area product (DAP), were estimated for PTB procedures with use of a Monte Carlo transport code and an adult mathematical phantom. Exposure parameters from 51 consecutive patients were used to determine average examination parameters for biliary drainage and stent implantation procedures. Thermoluminescent dosimeters were used in an anthropomorphic phantom to verify Monte Carlo calculations. Radiation-induced cancer and genetic risks were estimated. RESULTS: The results consist of doses normalized to DAP so patient dose from any technique and x-ray unit can be easily calculated for left and right biliary access and for separate or combined biliary and metallic stent implantation sessions. A good agreement was found between Monte Carlo-calculated data and data derived from thermoluminescent dosimetry. The average effective dose varied from 1.8 to 5.4 mSv depending on procedure approach (left vs right access) and procedure scheme. A maximum effective dose of 13 mSv was estimated for 30 minutes of fluoroscopy. CONCLUSIONS: Doses delivered to patients undergoing PTB procedures are comparable to those that arise from computed tomography protocols. Radiation-induced cancer risk may be considerable for young patients undergoing PTB drainage and stent implantation procedures.

Adult↗

Occupational radiation exposure from fluoroscopically guided percutaneous transhepatic biliary procedures.

PURPOSE: The aim of this study was to determine occupational dose levels for projections commonly used in fluoroscopically guided percutaneous transhepatic biliary (PTB) drainage and stent placement procedures. METHODS: Exposure data from 71 consecutive PTB examinations were analyzed to determine average examination parameters for biliary drainage and stent placement procedures. An anthropomorphic phantom was exposed at three projections common in PTB interventions according to the actual geometric parameters recorded in the patient study. Scattered air-kerma dose rates were measured for neck, waist, and gonad levels at various sites in the interventional radiology laboratory. To produce technique- and instrumentation-independent data, dose rate values were converted to dose-area product (DAP)-normalized air-kerma values. In addition, sets of thermoluminescent dosimetry crystals were placed in both hands of the interventional radiologist to monitor doses during all PTB procedures. RESULTS: Isodose maps of DAP-normalized air-kerma doses in the interventional laboratory for projections commonly used in PTB procedures are presented. To facilitate effective dose estimation, normalized dosimetric data at the interventional radiologist's position are presented for left and right access drainage procedures, metallic stent placement only, and drainage and metallic stent placement in one-session procedures with and without under-couch shielding. Doses to the hands of interventional radiologists are presented for left and right transhepatic biliary access and metallic stent placement. CONCLUSIONS: Body level-specific normalized air-kerma distributions from commonly used projections in PTB procedures may be useful to accurately quantify dose, maximum workloads, and possible radiogenic risks delivered to medical personnel working in the interventional radiology laboratory. Normalized dose data presented will enable occupational exposure estimation from other institutions.

Aged↗

Normalized dose data for upper gastrointestinal tract contrast studies performed to infants.

The aim of the current study was to (a) provide normalized dose data for the estimation of the radiation dose from upper gastrointestinal tract contrast (UGIC) studies carried out to infants and (b) estimate the average patient dose and risks associated with radiation from UGIC examinations performed in our institution. Organ and effective doses, normalized to entrance skin dose (ESD) and dose area product (DAP) were estimated for UGIC procedures utilizing the Monte Carlo N-particle (MCNP) transport code and two mathematical phantoms, one corresponding to the size of a newborn and one to the size of a 1-year-old child. The validity of the MCNP results was verified by comparison with dose data obtained in physical anthropomorphic phantoms simulating a newborn and a 1-year-old infant using thermoluminescence dosimetry (TLD). Data were also collected from 25 consecutive UGIC examinations performed to infants. Study participants were (a) 12 infants aged from 0.5 to 5.9 months (group 1) and (b) 13 infants aged from 6 to 15 months (group 2). For each examination, ESD and dose to comforters were measured using TLD. Patient effective doses were estimated using normalized dose data obtained in the simulation study. The risk for fatal cancer induction was estimated using appropriate coefficients. The results consist of tabulated dose data normalized to ESD or DAP for the estimation of patient dose. Conversion coefficients were estimated for various tube potentials and beam filtration values. The mean total fluoroscopy time was 1.26 and 1.62 min for groups 1 and 2, respectively. The average effective dose was 1.6 mSv for group 1 and 1.9 mSv for group 2. The risk of cancer attributable to the radiation exposure associated with a typical UGIC study was found to be up to 3 per 10 000 infants undergoing an UGIC examination. The mean radiation dose absorbed by the hands of comforters was 47 microGy. In conclusion, estimation of radiation doses associated with UGIC studies performed to infants can be made using the normalized dose data provided in the current study. Radiation dose values associated with UGIC examinations carried out to infants are not low and should be minimized as much as possible.

Body Burden↗

Data required for testicular dose calculation during radiotherapy of seminoma.

The purpose of this study was to provide the required data for the direct calculation of testicular dose resulting from radiotherapy in patients with seminoma. Paraortic (PA) treatment fields and dog-leg (DL) portals including paraortic and ipsilateral pelvic nodes were simulated on a male anthropomorphic phantom equipped with an artificial testicle. Anterior and posterior irradiations were performed for five different PA and DL field dimensions. Dose measurements were carried out using a calibrated ionization chamber. The dependence of testicular dose upon the distance separating the testicle from the treatment volume and upon the tissue thickness at the entrance point of the beam was investigated. A clamshell lead shield was used to reduce testicular dose. The scattered dose to testicle was measured in nine patients using thermoluminescent dosimeters. Phantom and patient exposures were generated with a 6 MV x-ray beam. Linear and nonlinear regression analysis was employed to obtain formulas describing the relation between the radiation dose to an unshielded and/or shielded testicle with the field size and the distance from the inferior field edge. Correction factors showing the variation of testicular dose with the patient thickness along beam axis were found. Bland-Altman statistical analysis showed that testicular dose obtained by the proposed calculation method may differ from the measured dose value by less than 25%. The current study presents a method providing reasonable estimations of testicular dose for individual patients undergoing PA or DL radiotherapy.

Calibration↗

Estimation of effective doses to adult and pediatric patients from multislice computed tomography: A method based on energy imparted.

The purpose of this study is to provide a method and required data for the estimation of effective dose (E) values to adult and pediatric patients from computed tomography (CT) scans of the head, chest abdomen, and pelvis, performed on multi-slice scanners. Mean section radiation dose (dm) to cylindrical water phantoms of varying radius normalized over CT dose index free-in-air (CTDIF) were calculated for the head and body scanning modes of a multislice scanner with use of Monte Carlo techniques. Patients were modeled as equivalent water phantoms and the energy imparted (epsilon) to simulated pediatric and adult patients was calculated on the basis of measured CTDI(F) values. Body region specific energy imparted to effective dose conversion coefficients (E/epsilon) for adult male and female patients were generated from previous data. Effective doses to patients aged newborn to adult were derived for all available helical and axial beam collimations, taking into account age specific patient mass and scanning length. Depending on high voltage, body region, and patient sex, E/epsilon values ranged from 0.008 mSv/mJ for head scans to 0.024 mSv/mJ for chest scans. When scanned with the same technique factors as the adults, pediatric patients absorb as little as 5% of the energy imparted to adults, but corresponding effective dose values are up to a factor of 1.6 higher. On average, pediatric patients absorb 44% less energy per examination but have a 24% higher effective dose, compared with adults. In clinical practice, effective dose values to pediatric patients are 2.5 to 10 times lower than in adults due to the adaptation of tube current. A method is provided for the calculation of effective dose to adult and pediatric patients on the basis of individual patient characteristics such as sex, mass, dimensions, and density of imaged anatomy, and the technical features of modern multislice scanners. It allows the optimum selection of scanning parameters regarding patient doses at CT.

Adult↗

Hepatic artery aneurysm presenting with hemobilia in a patient with Behçet's disease: treatment with percutaneous transcatheteral embolization.

We herein report a case of hemobilia caused by a hepatic artery aneurysm. A 40-year-old male patient with a history of Behçet's disease with a thrombus hanging out of the papilla of Vater had a large hepatic aneurysm in angiography. The hepatic artery feeding the aneurysm was embolized. Endovascular treatment can treat patients with hepatic artery aneurysms caused by Behçet's disease.

Adult↗

Fluoroscopically guided implantation of modern cardiac resynchronization devices: radiation burden to the patient and associated risks.

OBJECTIVES: To establish radiation risks for patients undergoing fluoroscopically guided cardiac resynchronization device implantation. BACKGROUND: Cardiac resynchonization therapy (CRT) may be associated with extended fluoroscopic exposure. METHODS: The fluoroscopy time, dose-area product (DAP), exposure parameters, and percentage contribution of the fluoroscopic projections commonly used were recorded in a series of 14 consecutive patients referred for cardiac resynchronization device implantation and compared to corresponding data obtained from a control group of 20 patients who underwent a conventional rhythm device implantation operation. The DAP to peak skin dose, DAP to effective dose, and DAP to gonadal dose conversion factors were determined for biventricular pacing and conventional rhythm device implantation using a humanoid phantom and thermoluminescence dosimetry. RESULTS: The mean total fluoroscopy time and DAP values were 35.2 min and 4,765 cGy cm2, respectively, for biventricular pacing and 8.2 min and 1,106 cGy cm2, respectively, for conventional rhythm device implantation. Patient skin dose from biventricular pacing procedures requiring extended fluoroscopic exposure may exceed threshold dose for the induction of skin effects only if X-ray source-to-skin distance is kept low. The risk values for fatal cancer and severe hereditary disorders, respectively, associated with a typical CRT procedure were 273 per million and 0.2 per million treated patients. CONCLUSIONS: Radiation risks associated with fluoroscopically guided CRT procedures may be considerable. Present data may be used for the estimation of patient radiation risks from CRT procedures performed in other institutions.

Aged↗

Fluoroscopy-controlled voiding cystourethrography in infants and children: are the radiation risks trivial?

The purpose of this study was to determine the gonadal dose, effective dose and relevant radiogenic risks associated with pediatric patients undergoing voiding cystourethrography (VCUG). Exposure parameters were monitored in 118 consecutive children undergoing VCUG. The entrance surface dose (ESD) was determined by thermoluminescent dosimeters (TLDs). For male patients, the gonadal dose was determined by TLDs attached on the anterior scrotum. For female patients, the gonadal dose was estimated by converting ESD to the ovarian dose. ESD-to-ovarian dose conversion factors were determined by thermoluminescence dosimetry and physical anthropomorphic phantoms representing newborn and 1-, 5- and 10-year-old individuals. The effective dose was estimated by using ESD and data obtained from the literature. The mean fluoroscopy time and number of radiographs during VCUG were 0.73 min and 2.3 for female and 0.91 min and 3.0 for male pediatric patients, respectively. The gonadal dose range was 0.34-5.17 mGy in boys and 0.36-2.57 mGy in girls. The corresponding ranges of effective dosage were 0.12-1.67 mSv and 0.15-1.45 mSv. Mean radiation risks for genetic anomalies and carcinogenesis following VCUG during childhood were estimated to be up to 15 per million and 125 per million, respectively. Radiation risks associated with pediatric patients undergoing VCUG should not be disregarded if such a procedure is to be justified adequately.

Adolescent↗

Adrenal glands in beta-thalassemia major: magnetic resonance (MR) imaging features and correlation with iron stores.

This study aimed at describing the magnetic resonance (MR) imaging features of the adrenal glands in beta-thalassemic patients and at investigating the relation between adrenal and hepatic siderosis. Adrenal signal intensity (SI) was retrospectively assessed on abdominal MR studies of 35 patients with beta-thalassemia major undergoing quantification of hepatic siderosis and 12 healthy controls, using T1-(120/4/90), intermediate-(120/4/20), and T2*-(120/15/20) weighted GRE sequences. Adrenal SI was graded as grade 0 (normal SI on all sequences), grade 1 (hypointensity on T2* alone), or grade 2 (hypointensity on at least T2*). Adrenal size was measured in the thalassemic patients and compared with normative data. Liver-to-muscle (L/M) SI ratios, expressing hepatic siderosis, were estimated on each sequence. Serum ferritin levels were recorded. Adrenal hypointensity (grades 1 and 2) was noted in 24/35 (68.6%) patients. L/M ratios correlated significantly with adrenal SI in all sequences. Patients with grade 1 and grade 2 adrenal SI had significantly decreased L/M ratios compared with grade 0. Serum ferritin correlated significantly with L/M values but not with adrenal SI. Adrenal size was within normal limits. Diffuse hypointensity in normal-sized adrenals is a common MR finding in beta-thalassemic patients and correlates with the degree of hepatic siderosis.

Adrenal Gland Diseases↗

Fractional anisotropy and mean diffusivity measurements on normal human brain: comparison between low-and high-resolution diffusion tensor imaging sequences.

Non-invasive in vivo visualization of white matter fiber tracts is currently feasible by means of diffusion tensor imaging (DTI) techniques. DTI-derived metrics, like fractional anisotropy (FA) and mean diffusivity (MD), have the potential to improve tissue characterization. Technical optimization of diffusion tensor sequences, including signal-to-noise ratio and spatial resolution, was performed for 20 normal subjects. High- and low-resolution DTI sequences were applied on all subjects and FA, MD parametric maps were reconstructed for both protocols. Voxel-based statistical analysis revealed regions with significantly different FA and MD values between the two sequences, while the same type of analysis was performed to illustrate regions with significantly different signal-to-noise ratio. In conclusion, optimized DTI sequences may be applied routinely in clinical practice with a standard MR scanner, while accurate quantification of FA and MD may improve lesion characterization.

Adolescent↗

Complementary role of helical CT cholangiography to MR cholangiography in the evaluation of biliary function and kinetics.

To explore the potential role of computed tomographic cholangiography (CTC) in relation to magnetic resonance cholangiography (MRC) in cases in which knowledge of biliary kinetics and functional information are important for therapeutic decisions, 31 patients (14 men and 17 women) underwent MRC followed by CTC. We examined nine post-cholecystectomy cases with right upper quadrant abdominal pain, six cases with a previous biliary-enteric anastomosis and clinical evidence of cholangitis, eight biliary strictures with pain or symptoms of cholangitis, four cases with strong clinical evidence of sclerosing cholangitis, three cases with suspected post-laparoscopic cholecystectomy bile leakage, and one case with chronic pancreatitis and a common bile duct stent associated with cholangitis. In relation to MRC, CTC provided additional biliary functional information as follows: abnormal biliary drainage through the ampulla in 7/9 cholecystectomy cases, impaired drainage in 3/6 biliary-enteric anastomoses, and complete obstruction in 2/8 biliary strictures. CTC diagnosed early sclerosing cholangitis in 4/4 cases and confirmed suspected bile leakage in 1/3 post-laparoscopic cholecystectomy patients, and the patency of the biliary stent in the patient with chronic pancreatitis. Thus, CTC provides clinically important information about the function and kinetics of bile and complements findings obtained by MRC.

Abdominal Pain↗