Search PubMed⌕ Search

Biomedical subjects

Nicasio Perez-Castellano

Publications and source records attributed to Nicasio Perez-Castellano.

3 recordsLinked to original sources

Biventricular vs. left univentricular pacing in heart failure: rationale, design, and endpoints of the B-LEFT HF study.

AIMS: Cardiac resynchronization therapy (CRT) confers sustained therapeutic benefits to patients suffering from congestive heart failure (CHF) due to systolic dysfunction associated with ventricular dyssynchrony. Biventricular (BiV) pacing has, thus far, been the preferred method, as it corrects both electrical and mechanical dyssynchrony. Left ventricular (LV) only pacing, which has conferred similar benefits in pilot studies, may be an alternative treatment method. 'Biventricular vs. left univentricular pacing with ICD back-up in heart failure patients' (B-LEFT HF) is an international, prospective, randomized, parallel-design, double-blind, clinical trial to examine whether LV only pacing is as safe and effective as BiV pacing in patients suffering from CHF. METHODS AND RESULTS: The trial will randomly assign 172 patients to either LV only or BiV pacing. The study has prospectively defined efficacy endpoints to be evaluated at 6 months, which are (i) changes in functional capacity and degree of reverse remodelling (primary) and (ii) changes in the heart failure clinical composite response (secondary). CONCLUSION: Because LV only pacing in CRT is likely to be technically less challenging and costly than BiV, a specifically designed study is needed to compare the safety and effectiveness of the two configurations. B-LEFT HF has been designed to settle this critical issue.

Adult↗

Pacemapping.

Explore the source record for details and available documents.

Journal Article↗

Basic assessment of paced activation sequence mapping: implications for practical use.

Some experiences support the use of atrial paced activation sequence mapping, but there is no systematic study assessing its spatial resolution, reproducibility, and influence of pacing parameters. The aim of this study was to evaluate these issues by using a 24-pole catheter positioned at the atrial aspect of the tricuspid and mitral annuli in 15 patients. Bipolar pacing was performed at two sites (right and left atria), 2 cycle lengths (300 and 500 ms) and two outputs (twice and tenfold the late diastolic threshold voltage for 2-ms pulses). The elapsed time between the atrial activation at the two dipoles adjacent to the pacing dipole (activation time [AT]) was measured during each pacing sequence. Changes in cycle length did not modify the AT. The increase in voltage slightly modified the AT (maximum -2 ms at the RA; 95% CI -3 to -1 ms) due to a greater shortening of the conduction time to the dipole located next to the anode. The 95% limits of the intraobserver and interobserver agreements in the AT measurement were -2 to 3 ms and -3 to 3 ms, respectively. The spatial resolution was studied in ten patients by measuring the AT during pacing from each dipole of a 20-pole catheter with a 1-3-1 mm interelectrode distance. The mean AT change was 10 +/- 4 ms per 6 mm of pacing site displacement (95% CI 8-11 ms, range 2.5-20 ms). In conclusion, paced atrial activation sequence analysis is reproducible, accurate, and relatively independent of pacing parameters.

Cardiac Pacing, Artificial↗