Pacemaker implantation in a patient with paroxysmal atrial fibrillation and left pneumonectomy.

Paroxysmal atrial fibrillation is a common occurrence in patients following thoracic surgery and in some patients remains refractory to medical therapy. New pacemaker devices are available with atrial preventative and termination pacing algorithms designed to reduce arrhythmia recurrences. This report describes the implantation of such a device in a patient following pneumonectomy and the subsequent effect on atrial arrhythmia burden.

Atrial Fibrillation↗

DC cardioversion of persistent atrial fibrillation: a comparison of two protocols.

BACKGROUND: Current guidelines for transthoracic direct-current cardioversion (DCCV) of atrial fibrillation (AF) recommend a step-up energy protocol. The aim of this study was to compare such a protocol with a protocol involving a high initial energy shock, anteroposterior paddle position and reversal of shock polarity, on cardioversion efficacy, total energy delivery, use of sedation and patient tolerability. METHODS: 261 patients (mean age 71+/-10 years, 62% male) referred for elective DCCV of persistent AF were enrolled. Patients were randomised to either protocol A: (1) 200 J anteroapical, (2) 360 J anteroapical, (3) 360 J anteroposterior; or protocol B: (1) 360 J anteroapical, (2) 360 J anteroposterior, and (3) 360 J posteroanterior. All procedures were performed under sedation with intravenous diazepam. RESULTS: Protocol B improved shock success rates (protocol A first shock success rate=42%, protocol B=68%, p<0.001; protocol A second shock success rate=72%, protocol B 86%, p=0.006; protocol A third shock success rate=83%, protocol B=92%, p=0.03) and required fewer shocks to achieve sinus rhythm (1.3+/-0.6) compared with protocol A (1.6+/-0.7, p<0.001). There were no differences in cumulative energy used (protocol A 473+/-286 J, protocol B 436+/-273 J, p=0.24) or sedation requirements (protocol A diazepam 22.1+/-9.0 mg, protocol B 21.7+/-8.9 mg, p=0.75). Both protocols were equally well tolerated by patients. CONCLUSION: High initial energy increased success rates and decreased the number of shocks but resulted in similar cumulative energy delivery, sedation use and patient tolerability compared with a conventional step-up protocol.

Aged↗

New insights into the initiation of atrial fibrillation: a detailed intraindividual and interindividual analysis of the spontaneous onset of atrial fibrillation using new diagnostic pacemaker features.

BACKGROUND: This study investigated onset scenarios of atrial fibrillation (AF), the first phase of the Atrial Fibrillation Therapy (AFT) trial, to determine potential arrhythmogenic triggers as targets for atrial pacing algorithms that have been proposed for prevention of AF. METHODS AND RESULTS: Ninety-eight patients (58 men; age 65+/-11 years) with recurrent, symptomatic, drug-refractory AF and a conventional pacemaker indication in 31 of 98 received a dual-chamber pacemaker. Using novel diagnostic pacemaker features AF onset scenarios were prospectively evaluated in 612 AF episodes during a 2-month monitoring period, with atrial pacing limited to 40 bpm. The most common onset scenario was premature atrial complexes (PACs) before AF (48% onsets per patient), followed by bradycardia (33%), sudden onset (17%), and tachycardia (0%). Combinations of onset scenarios were frequent (median 2 different scenarios per patient). A main study finding was the significance of repetitive AF, with 33% of onsets per patient being initiated within 5 minutes of a previous AF episode. Sudden onsets were more frequent among patients with than without repetitive AF (24% versus 0% onsets per patient, P=0.011), whereas the proportion of PACs before AF was not statistically different (50% versus 37%, P=0.52); however, patients with repetitive AF had more PACs per hour (72 versus 29, P=0.023) and a higher number of AF episodes per day (17 versus 0, P=0.001) and were more likely to have at least 1 PAC-related onset (90% versus 53%, P<0.0001). CONCLUSIONS: Novel diagnostic pacemaker features allowed a detailed individual analysis of rate and rhythm changes before AF and thus uncovered a substantial intraindividual and interindividual variability of AF onset scenarios.

Aged↗

The clinical impact of implantable loop recorders in patients with syncope.

AIMS: Implantable loop recorders (ILR) provide an opportunity to record ECG data from a spontaneous syncopal event. We conducted a randomized study to investigate the impact of the Reveal Plus ILR on an unselected population of patients with recurrent syncope. Initial follow-up (at least 6 months) did not demonstrate a reduction in syncopal events or an improvement in quality of life. We report the planned extension of follow-up to 18 months. METHODS AND RESULTS: All patients presenting acutely with recurrent unexplained syncope over a 16-month period, following a basic clinical work-up, were randomized to receive the ILR or conventional investigation and management. A total of 421 patients presented, 201 were eligible, median age 74, (IQ range 61-81) 54% female, with median syncopes 3 (IQ range 2-6). Median follow-up 17 months (IQ range 9-23). 42 (43%) of ILR patients and 8 (6%) of conventional patients received an ECG diagnosis (hazard ratio 6.53, 95% CI 3.73-11.4, P<0.001). Time to second syncope was significantly longer for ILR patients, although of borderline significance (P=0.04). A greater variety of diagnoses and treatments were seen in ILR patients. ILR patients had fewer post-randomization investigations and fewer days in hospital; however, cost savings were not statistically significant. There was improved quality of life in the ILR group (visual analogue scales, P=0.03) for general wellbeing. Overall mortality was 12% with no difference between the two groups. CONCLUSION: Investigation by the ILR significantly increases the diagnostic rate and ECG directed treatments in a typical unselected syncopal population. Long-term follow-up has demonstrated a significant subsequent reduction in syncopal events with improved quality of life.

Aged↗

Myocardial injury, neurohormonal activation and inflammation after internal atrial defibrillation.

BACKGROUND: The effects of patient-activated atrial defibrillation on subclinical myocardial injury are unknown. Using biochemical markers, this study assessed the effect of a single internal atrial shock delivered by the implantable atrial defibrillator on myocardial damage, neurohormonal activation and inflammation. METHODS: Twelve patients were implanted with a dual chamber defibrillator for the sole indication of drug refractory symptomatic persistent atrial fibrillation (AF). All had maximum defibrillation energy programmed to maximise the first shock success rate. Creatine kinase isoenzyme, troponin T, cortisol, catecholamines, C-reactive protein and brain natriuretic peptide were measured (i) during sinus rhythm, (ii) 8 h after onset of spontaneously occurring AF (before cardioversion) and (iii) 8 h following successful patient activated cardioversion. RESULTS: There was no change in creatine kinase, troponin T, cortisol or C-reactive protein during AF or following internal cardioversion. Brain natriuretic peptide levels rose from a median value of 56 pg/ml during sinus rhythm (inter-quartile range 14-92 pg/ml) to 133 pg/ml during AF (30-262 pg/ml), p=0.002. There was a decrease 8 h after cardioversion to baseline (52 and 40-189 pg/ml), p=0.01. There were increases in serum adrenaline and noradrenaline levels during AF from 0.43 (0.12-0.61) to 0.58 pg/ml (0.39-0.80 pg/ml), p=0.002 and from 2.06 (1.61-2.59) to 2.83 nmol/l (2.43-3.46 nmol/l), p=0.02, respectively. These figures reverted to baseline levels 8 h post-cardioversion. CONCLUSIONS: Internal atrial defibrillation does not result in myocardial injury. The onset of AF results in sympathetic activation and increased brain natriuretic peptide levels, which resolve following restoration of sinus rhythm.

Adult↗

Long-term care of the patient with the atrial defibrillator.

With an aging population, atrial fibrillation is becoming an increasingly common cause of hospital admission. Patients with recurrent, symptomatic persistent atrial fibrillation often require repeated admissions to the hospital for cardioversion. The development of the atrial defibrillator has empowered such patients to take charge of their condition and perform cardioversion on themselves at home. This liberates them from the worry of hospitalization and can increase patient confidence. The implantation of an atrial defibrillator, however, has some disadvantages, and long-term use of the device exposes patients to some of the psychological adaptations that occur in recipients of implantable devices. This article discusses in depth the patient selection process, the implantation procedure, the use of the atrial defibrillator, and problems that can arise during long-term follow-up.

Anti-Arrhythmia Agents↗

Temporal changes in atrial refractoriness following DC cardioversion of persistent atrial fibrillation in man.

AIMS: Studies have demonstrated shortening of the atrial effective refractory period (ERP) after episodes of atrial fibrillation (AF). This is termed atrial remodelling. It is unclear whether restoration of SR after persistent AF in patients with a clinical substrate results in reversal of this shortening and whether this is maintained long term. METHODS AND RESULTS: The ERP was determined at mid-lateral right atrial wall (MLRA) and right atrial appendage (RAA) at 600 ms and 400 ms drive cycle lengths and at basic sinus cycle length in 81 patients with persistent AF immediately, 24 h and 2 weeks following external DC cardioversion. All atrially active drugs were stopped for at least 5 half lives. (1) Prolongation of the ERP was observed at both atrial sites and all cycle lengths up to 24 h post cardioversion (p < 0.0001). (2) However, between 24 h and 2 weeks a subsequent shortening occurred in the ERP returning it to near post cardioversion levels. (3) The ERP was significantly longer at 24 h post cardioversion in patients who remained in SR for 2 weeks or longer compared with those who reverted to AF. CONCLUSION: Prolongation of the atrial ERP occurred following restoration of SR in persistent AF patients but was not maintained and displayed a biphasic pattern such that by 2 weeks the ERP had returned to baseline values. Despite this finding, a longer ERP at 24 h post cardioversion was associated with maintenance of SR in the medium-term.

Aged↗

How do atrial pacing algorithms prevent atrial arrhythmias?

With an ageing population, atrial fibrillation has become an increasing cause of hospital admission and morbidity. Pacemaker implantation may prevent atrial tachyarrhythmias by preventing bradycardia and pauses. Implantable devices are now available with specific atrial pacing algorithms designed to prevent atrial arrhythmias. These algorithms work by increasing the atrial pacing rate to achieve continuous overdrive pacing or by responding to triggers such as premature atrial complexes. This article examines how the algorithms work by describing the functions of one of the new generation of pacemakers in detail. Early studies have indicated that the use of preventative pacing can reduce atrial arrhythmia burden and symptomatic atrial fibrillation in selected patients. There are clearly some patients who benefit from implantation of these devices but what remains unclear is how to identify this patient group.

Algorithms↗

Improving the acceptability of the atrial defibrillator for the treatment of persistent atrial fibrillation: the atrial defibrillator sedation assessment study (ADSAS).

BACKGROUND: To compare the acceptability and effectiveness of three pre-medication regimens for manually activated cardioversion of recurrent persistent atrial fibrillation. METHODS: Eighteen patients implanted with the Jewel AF atrial defibrillator for drug-resistant persistent atrial fibrillation only were studied in an open-labelled randomised crossover study. Patients were assigned to sedation (S) with midazolam elixir, analgesia (A) with morphine sulphate or combination therapy (C) with dextromoramide and lorazepam. Pre-medication was taken up to 1 h before cardioversion. Patients rotated through each type of medication after undertaking at least one cardioversion. Visual analogue scales were completed immediately post-cardioversion and 24 h later for pain, anxiety and 'unpleasantness'. Higher scores represented a worse outcome. RESULTS: After 2 years' follow-up, 238 cardioversions were performed with S, 17 with A and 35 with C. The mean immediate combined score for S (10.9, 95% confidence interval (CI) 8.2-13.6) was significantly lower than for A (17.3, 95% CI 15.1-19.5, P = 0.01) and for C (15.9, 95% CI 12.3-19.6, P = 0.02). All patients who used S chose it as the most favourable pre-medicant. All patients who used A found it the least acceptable. CONCLUSION: Sedation rather than analgesia enhanced the acceptability of manually activated atrial defibrillation.

Adult↗

The circadian variation of atrial defibrillation thresholds.

BACKGROUND: A circadian variation exists for ventricular defibrillation thresholds (DFTs) with a morning peak and a corresponding decrease in therapy success rates from implantable cardioverter defibrillators. Such a variation in atrial DFTs may have implications for the timing of internal cardioversion of atrial arrhythmias. The aim of this study was therefore to determine the circadian variation of atrial DFTs in patents with recurrent atrial fibrillation (AF). METHODS AND RESULTS: Data were collected as part of the worldwide Jewel AF-only study. Patients had recurrent persistent AF and no history of ventricular arrhythmias. The atrial DFT was assessed at device implantation using a step-up protocol and was recorded for 100 patients (age 63.0 +/- 11.7, 74% male, ejection fraction 49.6 +/- 17.8%, left atrial diameter 46 +/- 9 mm). The mean atrial DFT was 6.3 +/- 4.3 J. For the most commonly tested lead configuration (right atrium to coronary sinus in 56 patients), the atrial DFT for patients implanted in the morning (3.3 +/- 1.5 J) was significantly lower than for both the DFT measured in the afternoon (5.8 +/- 3.4 J, p < 0.01) and the DFT measured in the evening (7.4 +/- 5.9 J, p < 0.01). CONCLUSION: There may be a significant variation in measured atrial DFT for the right atrium to coronary sinus configuration, with a nadir in the morning. This is the converse to measurements of ventricular DFTs suggesting different regulatory electrophysiological mechanisms. Further investigation of this possible variation is warranted.

Aged↗

Does sinus rhythm beget sinus rhythm? Long-term follow-up of the patient activated atrial defibrillator.

The aim of this study was to determine the effect of early patient activated cardioversion of atrial fibrillation (AF) using the atrial defibrillator on recurrence of AF. Fifteen patients, mean age 63 +/- 14 years, 80% men, with drug-resistant persistent AF were implanted with the Jewel AF atrial defibrillator. All patients performed self-administered cardioversion for AF recurrences. Over a 2 year follow-up, 238 patient-activated cardioversions were performed in 14 patients. Sinus rhythm was restored on every occasion with 96% of episodes terminating with a single shock. The median time from AF onset to patient awareness of symptoms was 2.5 hours. The median time from onset of symptoms to cardioversion was 3.5 hours. Comparison of the first and second six month period following implant showed a nonsignificant increase in mean total AF duration (75.7 +/- 107.8 hours vs 146.6 +/- 194.1 hours, P = 0.28). Two patients (13%) had a decreasing frequency of AF recurrences. The majority continued to have regular recurrences of AF. The atrial defibrillator is an extremely effective method of restoring sinus rhythm in patients with persistent AF. Regular early use of the atrial defibrillator, increased the duration of sinus rhythm in a minority of patients during long-term follow-up. Most patients had regular recurrences of AF requiring patient-activated cardioversion.

Adult↗

Improving the acceptability of the atrial defibrillator: patient-activated cardioversion versus automatic night cardioversion with and without sedation (ADSAS 2).

Acceptability of the atrial defibrillator is partly limited by concerns about shock related anxiety and discomfort. Sedation and/or automatic cardioversion therapy during sleep may ease shock discomfort and improve patient acceptability. Three atrial cardioversion techniques were compared: patient-activated cardioversion with sedation, automatic night cardioversion with sedation, and automatic night cardioversion without sedation. Sedation was oral midazolam (15 mg). Fifteen patients aged 60 +/- 13 years were assigned each strategy randomly for three consecutive episodes of persistent atrial fibrillation requiring cardioversion. Patients completed questionnaires for multiple parameters immediately and again at 24 hours postcardioversion. Atrial cardioversion strategies with oral sedation (patient-activated and automatic) significantly reduced shock recall by 77% (P < 0.005), therapy dissatisfaction by 57%-71% (P < 0.03), shock discomfort by 61%-73% (P < 0.01), shock pain by 79%-83% (P < 0.001), and shock intensity by 73%-77% (P < 0.03), compared to automatic night cardioversion without sedation (P < 0.02). Atrial shock pain was short-lived and caused little disruption to the patients' daily routines. Automatic night cardioversion without sedation, resulted in sleep disturbances not seen with the other strategies (42% vs 0%, P < 0.001) as well as concerns about future pain or discomfort. Twelve patients (80%) chose patient-activated cardioversion with sedation as their preferred treatment, and three (20%) remainder chose automatic night cardioversion with sedation. Ninety percent of patients chose automatic night cardioversion without sedation as the least acceptable therapy. Sedation significantly increases atrial shock acceptability regardless of cardioversion method. Shocks without sedation are significantly less acceptable to patients using the atrial defibrillators.

Anxiety↗

Effect of an implantable cardioverter defibrillator with atrial detection and shock therapies on patient-perceived, health-related quality of life.

BACKGROUND: This study used a device (DDD implantable cardioverter defibrillator [ICD]) capable of delivering pacing and shock therapies to restore normal sinus rhythm in patients with atrial tachycardias or atrial fibrillation (AF). The purpose of this study was to assess the effect of the device on patient-perceived, health-related quality of life (QOL). METHODS: The DDD ICD was implanted in 267 patients with drug refractory, symptomatic AF from 45 centers across Europe, the United States, and Canada. Patients completed self-reported, validated QOL assessments at baseline and at 3- and 6-month follow-up visits (The Medical Outcomes Short Form 36 [SF-36] and the Symptom Checklist [SCL]). RESULTS: The mean age of the study group was 62 +/- 12 years, and 73% of the patients were male. A total of 150 patients completed SF-36 assessments, and 138 patients completed SCL assessments at all 3 times. Baseline scores were more impaired (P <.05) on most SF-36 scales compared with norms for a general population, but were similar to a comparison group of patients with AF who were referred to tertiary care centers. The role-physical, physical functioning, vitality, mental health, and social functioning scales all improved significantly with time (all P <.04). Similarly, symptom frequency and severity (SCL) also improved significantly from baseline to 6 months (both P <.01). Shock therapy was delivered in 86 of the 150 patients (57%) with complete SF-36 evaluations. There was no evidence that receiving shocks decreased the relative improvement in QOL associated with implantation of the device. CONCLUSIONS: In a 6-month period, QOL improves after implantation of a DDD ICD with atrial shock and pacing therapies. These improvements were not attenuated by receipt of shocks.

Atrial Fibrillation↗

Circadian variation of arrhythmia onset patterns in patients with persistent atrial fibrillation.

BACKGROUND: The circadian onset patterns and cycle lengths of atrial tachyarrhythmias (AT) were determined in a group of patients with persistent atrial fibrillation. METHODS: Fifteen patients, mean age 63 +/- 14 years and 80% male, were implanted with the Jewel AF atrial defibrillator (Medtronic, Minneapolis, Minn) for persistent atrial fibrillation only. Onset times of AT and median onset atrial cycle lengths were determined from device memory. RESULTS: Over a follow-up period of 23.3 +/- 7 months, 227 episodes of persistent AT were treated by patient-activated atrial defibrillation. The peak onset of persistent AT was nocturnal, with 74% of episodes initiating between 8 pm and 8 am. Eighty-seven percent of the patients experienced an additional 403 paroxysmal AT episodes. These episodes showed a "double-peaked" pattern with the least number of episodes occurring between midnight and 8 am. The mean onset atrial cycle length of persistent AT was significantly shorter than the paroxysmal AT episodes (200 +/- 37 ms vs 240 +/- 39 ms, P <.005). The atrial cycle lengths at arrhythmia onset of both paroxysmal and persistent AT episodes also demonstrated circadian variation. CONCLUSION: There is a circadian distribution of onsets for persistent AT with predominance at night. Patients with persistent AF have >1 type of atrial arrhythmia with differences in the onset patterns and atrial cycle lengths, suggesting different triggers and onset mechanisms.

Adult↗

Echocardiographic changes and predictors of arrhythmia recurrence after long-term use of the atrial defibrillator.

BACKGROUND: The patient-activated atrial defibrillator allows patients to cardiovert themselves from atrial fibrillation soon after the onset of symptoms. The long-term effects of early cardioversion from persistent atrial fibrillation on left ventricular performance and left atrial size are unknown. METHODS: Eighteen patients, mean age 63.4, 83% male, had the Jewel((R)) AF atrial defibrillator implanted for persistent atrial fibrillation only. Transthoracic echocardiography was performed 3-monthly following implant. Parasternal long axis measurements were taken using conventional M-mode techniques. RESULTS: Over follow-up of 28.0+/-9 months, 377 episodes of persistent atrial fibrillation were terminated by patient-activated cardioversion (median 15 per patient). Echocardiographic measurements at implant were; left atrium 44+/-6 mm, left ventricular end-diastolic diameter 49+/-7 mm, left ventricular end-systolic diameter 34+/-7 mm, fractional shortening 33+/-10% and ejection fraction 65+/-17%. After 1 year there had been a significant decrease in mean left atrial size to 41+/-6 mm (P=0.02) and an increase in mean ejection fraction to 73+/-8% (P=0.04). At long-term follow-up however, all parameters reverted to pre-implant levels. Baseline echocardiographic variables did not predict which patients would demonstrate serial increases in sinus rhythm duration between shocks during long-term follow-up. Patients on antiarrhythmic drug therapy however were more likely to demonstrate "sinus rhythm begetting sinus rhythm". CONCLUSIONS: Use of the atrial defibrillator for spontaneous persistent atrial fibrillation is associated with a medium-term (1 year) reduction in left atrial size and an increase in ejection fraction. These changes were not maintained in the long-term. Synergistic therapy with antiarrhythmic drugs may prolong periods of sinus rhythm between arrhythmia recurrences.

Adult↗

Does rapid atrial pacing terminate atrial fibrillation? A comparison of laboratory and device termination studies.

Atrial fibrillation is understood to be a re-entrant arrhythmia and for many years electrophysiologists have attempted to pace-terminate the rhythm. Several studies have demonstrated that an excitable gap is present during atrial fibrillation and that the capture of small amounts of atrial tissue is possible. Early attempts to terminate atrial fibrillation however were unsuccessful. The rapid development of pacemaker and defibrillator technology has provided an exciting new direction for the treatment of recurrent symptomatic atrial fibrillation. Results from studies of the effectiveness of atrial anti-tachycardia pacing algorithms have suggested that 50% of atrial arrhythmias (including atrial fibrillation) can be pace-terminated. These findings conflict with data from the electrophysiology laboratory where atrial fibrillation has yet to be convincingly terminated. In this review, the current literature is discussed and possible reasons for this discrepancy are proposed.

Algorithms↗