Search PubMed⌕ Search

Biomedical subjects

Neil Beaudry

Publications and source records attributed to Neil Beaudry.

4 recordsLinked to original sources

Wavelength dependence of the apparent diameter of retinal blood vessels.

Imaging of retinal blood vessels may assist in the diagnosis and monitoring of diseases such as glaucoma, diabetic retinopathy, and hypertension. However, close examination reveals that the contrast and apparent diameter of vessels are dependent on the wavelength of the illuminating light. In this study multispectral images of large arteries and veins within enucleated swine eyes are obtained with a modified fundus camera by use of intravitreal illumination. The diameters of selected vessels are measured as a function of wavelength by cross-sectional analysis. A fixed scale with spectrally independent dimension is placed above the retina to isolate the chromatic effects of the imaging system and eye. Significant apparent differences between arterial and venous diameters are found, with larger diameters observed at shorter wavelengths. These differences are due primarily to spectral absorption in the cylindrical blood column.

Algorithms↗

In vitro multispectral diffuse reflectance measurements of the porcine fundus.

PURPOSE: To quantify the reflectance of the swine fundus as a function of illumination angle and wavelength using a novel technique of intravitreal illumination. METHODS: Enucleated swine eyes were illuminated with a scanning monochromator coupled to a fiber-optic probe placed in the vitreous at several locations. Intravitreal illumination was used to reduce the effects of extraneous reflections and scatter from the anterior structures of the eye, including glints from the internal limiting membrane and blood vessels. Intravitreal illumination provided different light paths and additional information to apply to retinal reflectance modeling. A 25-mm(2) region of the illuminated fundus was imaged while the angle of illumination was varied over a maximum range of 22 degrees . Multispectral images from areas free of large blood vessels were acquired. The diffusely reflected intensity was integrated over the pupil with a solid angle of 0.028 steradians. The spectral reflectance function was calculated for multiple illumination angles. RESULTS: Multispectral fundus image sets were obtained for two enucleated swine eyes by using intravitreal illumination. The fundus spectral reflectance function showed decreasing reflectance with increasing illumination angle, rapid changes in the 430- to 480-nm range, and a fairly consistent reflectance decrease for 480 to 700 nm. CONCLUSIONS: Variations in fundus spectral reflectance with change in the illumination angle were found to deviate from Lambertian behavior, varying from Lambertian by 5% across the spectrum in one sample and 20% in a second sample. Intravitreal illumination resulted in markedly decreased extraneous reflections.

Animals↗

Retinal oximetry using intravitreal illumination.

PURPOSE: To demonstrate spectroscopic retinal oximetry measurements on arteries and veins in swine using intravitreal illumination. Retinal arterial and venous saturations are measured for a range of inspired O2 levels after pars plana vitrectomy. METHODS: Pars plana vitrectomy and intravitreal manipulations were performed on two female American Yorkshire domestic swine. Light from a scanning monochromator was coupled into a fiberoptic intraocular illuminator inserted into the vitreous. The retinal vessels were illuminated obliquely, minimizing vessel glints. Multispectral images of the retinal vasculature were obtained as the swine's arterial blood oxygen saturation was decreased from 100% to 67% in decrements of approximately 10%. Retinal vessel spectra were used to calculate oxygen saturation in selected arteries and veins. Arterial oxygen saturations were calibrated using blood gas analysis on blood drawn from a Swan-Ganz catheter placed in the femoral artery. RESULTS: Oblique illumination of retinal vessels using an intravitreal fiberoptic illuminator provided a substantial reduction in the central vessel glint usually seen in fundus images, thus simplifying the analysis of spectral data. The vessel shadows were displaced from the vessel image simplifying the light paths in the eye. Using a full spectral analysis simplified by the light path reductions, we calculated retinal vessel saturations. The reduction of glint allowed for increased accuracy in measuring retinal vessel spectral optical density. Abnormally low retinal venous oxygen saturations were observed shortly after pars plana vitrectomy. CONCLUSIONS: Retinal oximetry using intravitreal illumination has been demonstrated. As a research tool, intravitreal illumination addresses several difficulties encountered when performing retinal oximetry with transcorneal illumination.

Animals↗

Evanescent-imaging-ellipsometry-based microarray reader.

We describe the development of a label-less ellipsometric imaging microarray reader. The ability of the ellipsometric microarray reader to measure binding of sample to microarray surface is verified using oligonucleotide complementary DNA (cDNA) microarrays. Polarized light illuminates the microarray surface through a glass substrate at an angle beyond the critical angle and changes in the polarization of totally internally reflected light resulting from binding events on the microarray surface are measured. This polarization change is used to measure the thickness of biomolecules bound to the microarray. A prototype ellipsometric imaging microarray reader is constructed and calibrated, and the performance is evaluated with cDNA microarrays. The microarray reader measures changes in refractive index changes as small as 0.0024 and thickness changes as small as 0.28 nm. The optimization of angle of incidence and substrate refractive index necessary to achieve high sensitivity is also described. This ellipsometric technique offers an attractive alternative to fluorescence-microarray readers in some genomic, proteomic, diagnostic, and sensing applications.

Algorithms↗