Search PubMed⌕ Search

Biomedical subjects

Nancy M Richards

Publications and source records attributed to Nancy M Richards.

5 recordsLinked to original sources

A prospective comparison of 3 new-generation pulse oximetry devices during ambulation after open heart surgery.

OBJECTIVE: To assess the clinical performance of 3 new-generation pulse-oximetry signal-processing software systems (Philips FAST, Masimo SET, and Nellcor N-3000) during ambulation after open-heart surgery. DESIGN: Prospective, convenience sample. SETTING: Cardiac surgical progressive care unit in a 629-bed, not-for-profit, tertiary-care teaching hospital. PATIENTS: Status post-cardiac-surgery patients (n = 36) during their first postoperative ambulation. INTERVENTIONS: None. PROTOCOL: Randomization was used for digit and hand selection, and all 3 devices were used continuously during ambulation. Data on dropouts, false alarms, and correlation with heart rate were recorded. We continuously measured arterial oxygen saturation via pulse oximetry during ambulation with all 3 devices. RESULTS: Pairwise comparisons indicated significant differences among the 3 devices for data dropout and false alarm. In repeated-measures analysis, the Nellcor N-3000 had the greatest likelihood of data dropout (odds ratio of 31.9 to Masimo and 5.6 to Philips, at the 95% confidence interval). However, the converse was true for false alarms; the Masimo had the most false alarms, with an odds ratio of 17.9 to Nellcor and 2.3 to Philips, at the 95% confidence interval. There were also significantly more dropouts with all 3 devices when readings were taken on a hand on an arm from which a radial graft had been taken (p = 0.004). For heart-rate correlation, the mean absolute difference among the 3 devices was similar: Philips = 4.3 beats/min, Masimo = 5.1 beats/min, and Nellcor = 3.0 beats/min. CONCLUSIONS: There are significant differences among the 3 devices with regard to dropout and false alarms. High numbers of dropouts are problematic because no pulse-oximetry patient information is available during dropout. However, false alarms are even more problematic, because they desensitize clinicians to alarms and call into question the accuracy of displayed data. While our data highlight the statistical differences between the studied oximeters, the clinical implications of these differences warrant further study.

Adult↗

Ventricular assist devices: developing and maintaining a training and competency program.

Ventricular assist devices (VADs) have made it possible for patients with end-stage heart failure to survive until a donor heart is available. In addition to serving as a bridge to transplantation, evolving indications for VADs include bridge to recovery and destination therapy. There are many VAD programs, but in the majority of programs only a small number of devices are implanted each year. Low volume poses a challenge in terms of provision of comprehensive education and training for nurses who will care for patients with VADs and in terms of maintaining competency to care for these patients. This article briefly addresses current VAD technology and VAD program development. The major focus is on the education and competency challenges and solutions the authors have experienced as infrequent users of VAD technology.

Clinical Competence↗