Search PubMed⌕ Search

Biomedical subjects

Naeun Park

Publications and source records attributed to Naeun Park.

9 recordsLinked to original sources

Towards a reference model for representing nursing information needs.

Information needs studies in clinical settings often face the problem of integrating and analyzing data collected using different study tools. Generally, a coding taxonomy or a model is developed to capture and code the study data. Significant efforts are required to develop a model that not only captures the study data but is also closer to the clinical domain to draw meaningful real world inferences. Further, a study-specific model limits comparative evaluation of studies across different institutions. In this paper, we propose a reference model for representing nursing information needs. We use an iterative and collaborative approach in representing the concepts in the model. The model consists of 33 information (need) concepts, 29 information sources and 7 categories of nursing tasks which were used to code 228 identified information need instances.

Hospitals, Urban↗

Genetic and environmental contributions to carotid intima-media thickness and obesity phenotypes in the Northern Manhattan Family Study.

BACKGROUND AND PURPOSE: Both carotid intima-media thickness (IMT) and obesity are independent determinants of stroke and cardiovascular disease. The prevalence of obesity is higher in Hispanics. The genetic basis of IMT and obesity has not been well-characterized in Caribbean Hispanics. The purpose of this study was to examine the genetic and environmental contributions to IMT and obesity in this population. METHODS: The data included 440 subjects from 77 Caribbean Hispanic families. Mean IMT and maximum IMT were measured in the internal carotid artery, common carotid artery, and carotid bifurcation. The total IMT was calculated as the mean value of IMT at all segments. Obesity phenotypes included body mass index (BMI), waist circumference, waist-to-hip ratio (WHR), and skin-fold thickness. Variance component methods were used to estimate age-adjusted and sex-adjusted heritability. Bivariate analyses were conducted to test for genetic and environmental correlations between IMT and obesity. RESULTS: Heritabilities for IMT ranged from 9% to 40%, with the highest for total maximum IMT and lowest for internal carotid artery maximum IMT. Heritabilities for BMI, waist circumference, WHR, and skin-fold thickness were 44%, 47%, 5%, and 36%, respectively. There were significant genetic, but not environmental, correlations between IMT and BMI, waist circumference, and skin-fold thickness. There were no genetic or environmental correlations between IMT and WHR. CONCLUSIONS: We found a substantial genetic contribution to IMT, BMI, waist circumference, and skin-fold thickness. Obesity and IMT may share common genetic factors. Future gene mapping studies are warranted to identify genes predisposing to IMT and obesity in this population.

Adult↗

Outcome after traumatic frontal intracerebral haemorrhage: a comparison of unilateral and bilateral haematomas.

Frontal intracerebral haemorrhage (ICH) is a common result of cranial trauma. Outcome differences between bilateral and unilateral frontal ICH are not well studied but would be valuable to predict prognosis in clinical practice. Two aims are proposed in this study: first to compare the risk of developing delayed ICH after bilateral or unilateral frontal ICH, and second to determine the variables helpful to predict outcome according to the Glasgow Outcome Scale (GOS). Between January 1993 and December 1997, 694 consecutive patients with traumatic ICH were admitted to the Chang Gung Medical Center within 24 h of the trauma. Patients with ICH in sites other than the frontal lobes were excluded. A total of 161 cases (mean age 46.3+/-20.3 years), including 57 bilateral (mean age 52.5+/-18.7 years) and 104 unilateral (mean age 42.9+/-20.5 years) traumatic frontal ICH were studied. Twenty-eight of 57 patients (49%) with bifrontal ICH versus 17 of 104 patients (16%) with unilateral frontal ICH had a further, delayed ICH. In 42 of 45 patients (93%) with delayed ICH, this occurred within 5 days of the initial trauma. Multivariate logistic regression was used to select significant predictors of outcome. We found that delayed ICH (p<0.001), age (p=0.004) and mechanism of injury (p=0.001) explained the worse outcome in patients with bifrontal ICH. The best-fitting logistic regression model included three variables: delayed ICH (p=0.011), initial GCS (p=0.023), and a sum score of clinical and radiological variables (p=0.003). Bifrontal ICH tended to occur in older patients after a fall and was associated with a higher risk of developing delayed ICH or brain stem compression compared to unilateral ICH damage. Using these three variables - delayed ICH, initial GCS, and the sum score - in a logistical regression model is useful to predict outcome in patients with traumatic frontal ICH and may aid patient management.

Adult↗

Comparison of the handheld Retinomax K-Plus2 and on-table autokeratometers in children with and without cycloplegia.

PURPOSE: To compare the keratometry measurements in children by the handheld Nikon Retinomax K-Plus2 (Rmax) and the on-table Topcon KR8100 autokeratometers and evaluate the degree of agreement in the 2 instruments between children with and without cycloplegia. SETTING: Department of Ophthalmology, Kaohsiung Municipal United Hospital, and Chang-Gung Memorial Hospital, Kaohsiung, Taiwan. METHODS: The first cohort comprised 61 children who were consecutively collected in the pediatric ophthalmology clinic. The keratometry was measured under cycloplegia. The second cohort included 156 school children who received routine vision screening without cycloplegia. The horizontal and vertical keratometry data were measured by both instruments. The mean bias and agreement between the 2 types of measurements were evaluated. RESULTS: Both horizontal and vertical keratometry data from the Rmax were systemically and mildly lower than the data from the Topcon. The mean keratometric difference in the 2 types of instruments was minimal and clinically acceptable: 72% to 85% was within +/-0.5 diopter. The agreement of measured data in the children without cycloplegia was higher than that in the children with cycloplegia. CONCLUSIONS: The handheld Retinomax provided comparable data to that of the conventional on-table Topcon. It is useful in the clinic to measure keratometry in children and therefore may offer a convenient tool for assessing corneal curvature for fitting contact lenses or for implanting intraocular lenses in young children.

Child↗

Immunohistochemical and ultrastructural comparative study of external lamina structure in 31 cases of cellular, classical, and melanotic schwannomas.

Unlike most soft tissue tumors, schwannoma is characterized by the presence of distinct linear, frequently duplicated external lamina (EL). Although electron microscopy remains the gold standard for demonstrating this unique feature and distinguishing its morphologic variants from mimickers, the use of two anti-EL antibodies, laminin and type IV collagen, appears to supersede electron microscopy in terms of current practice. To determine whether immunohistochemical expression correlates with ultrastructural findings, 10 cellular schwannomas, 18 classic schwannomas, and 3 melanotic schwannomas were evaluated ultrastructurally and immunohistochemically using antibodies to type IV collagen and laminin. Immunohistochemically, a moderate to strong intensity in more than 50% of tumor cells was detected using either antibody in most cases of cellular schwannomas (70%), the Antoni A areas of classic schwannomas (78%), and melanotic schwannomas (67%). Ultrastructurally, the presence of diffusely continuous, duplicated EL was observed in 30% of cellular schwannomas and 56% of classic schwannomas, while 50% of cellular schwannomas and 22% of classic schwannomas showed either continuous simple EL or discontinuous but duplicated EL alone. In addition, two cellular schwannomas (20%) and four classic schwannomas (22.2%) had only a simple layer of EL in focal areas. In contrast to the distinct immunostaining surrounding individual cells seen in the former two subtypes, all three melanotic schwannomas displayed a biphasic-staining pattern of the EL (ie, individual cell and nested), which was confirmed at the ultrastructural level. The authors found a significant difference in intensity between the Antoni A and B areas of classic schwannomas using both laminin and type IV collagen. In addition, the intensities of laminin and type IV collagen in the Antoni A areas of classic schwannomas were significantly stronger compared with those of cellular schwannomas. Nevertheless, there was no significant difference either between two antibodies or between cellular and classic variants with regard to the extent of immunoreaction. Only in classic schwannomas did the extent of immunoreaction against both laminin and type IV collagen correlate significantly with the ultrastructural EL distribution pattern (diffusely continuous vs. discontinuous). However, this association was not detected in cases of cellular schwannomas. On the other hand, the intensities of laminin and type IV collagen did not correlate with the ultrastructural thickness of EL, irrespective of the morphologic subtypes. In conclusion, both type collagen IV and laminin are still reliable markers of EL in various types of schwannomas. Schwannomas exhibiting a monolayered EL are as strong in immunoreaction as those displaying reduplicated/thickened EL, indicating that a single layer of EL is thick enough to be identified by both antibodies with sufficient sensitivity. The peculiar biphasic EL pattern seen in melanotic schwannoma remains under-recognized, which may lead to misdiagnosis as malignant melanomas, especially in limited biopsy specimens.

Adult↗

Impact of family history of high myopia on level and onset of myopia.

PURPOSE: To investigate the impact of a positive family history of high myopia on the level and onset of myopia and its ocular components. METHODS: A cross-sectional study was conducted. The participants (aged 17 to 45 years) were categorized into four groups: normal, mild, moderate, and high myopia. The age of first glasses for myopia was used as the onset of myopia. The impact of the family history on the level and the onset of myopia was quantified. Parental effect on corneal curvature (CC), anterior chamber depth (ACD), and axial length (AXL) was analyzed. RESULTS: The study included 185 normal subjects, 170 mild, 140 moderate, and 392 high myopes. Family history was strongly associated with the probands' status (P < 6 x 10(-12)). When there was >or=1 highly myopic parent, the odds ratios (ORs) of developing mild or moderate myopia were between 2.5 and 3.7 (95% CI: 1.1-6.5) and the ORs of having high myopia were > 5.5 (95% CI: 3.2-12.6). A strong association (P = 2 x 10(-6)) between parental myopic state and the AXL in the subjects was also found, but there was no statistical relationship for ACD or CC. There was an association between high myopia in parents and the onset of myopia in children. Siblings had a weaker association with the level of myopia and had no effect on the onset of myopia. CONCLUSIONS: This study found strong familial effects on the level and onset of myopia even after adjusting for environmental factors. The parental effect on ocular components in their offspring was primarily on AXL.

Adolescent↗

Comparison of the linkage results of two phenotypic constructs from longitudinal data in the Framingham Heart Study: analyses on data measured at three time points and on the average of three measurements.

BACKGROUND: Family studies are often conducted in a cross-sectional manner without long-term follow-up data. The relative contribution of a gene to a specific trait could change over the lifetime. The Framingham Heart Study offers a unique opportunity to investigate potential gene x time interaction. We performed linkage analysis on the body mass index (BMI) measured in 1970, 1978, and 1986 for this project. RESULTS: We analyzed the data in two different ways: three genome-wide linkage analyses on each exam, and one genome-wide linkage analysis on the mean of the three measurements. Variance-component linkage analyses were performed by the SOLAR program. Genome-wide scans show consistent evidence of linkage of quantitative trait loci (QTLs) on chromosomes 3, 6, 9, and 16 in three measurements with a maximum multipoint LOD score > 2.2. However, only chromosome 9 has a LOD score = 2.14 when the mean values were analyzed. More interestingly, we found potential gene x environment interactions: increasing LOD scores with age on chromosomes 3, 9, and 16 and decreasing LOD scores on chromosome 6 in the three exams. CONCLUSION: The results indicate two points: 1) it is possible that a gene (or genes) influencing BMI is (are) up- or down-regulated as people aged due to aging process or changes in lifestyle, environments, or genetic epistasis; 2) using mean values from longitudinal data may reduce the power to detect linkage and may have no power to detect gene x time, and/or gene x gene interactions.

Adult Children↗

Localization of a novel melanoma susceptibility locus to 1p22.

Over the past 20 years, the incidence of cutaneous malignant melanoma (CMM) has increased dramatically worldwide. A positive family history of the disease is among the most established risk factors for CMM; it is estimated that 10% of CMM cases result from an inherited predisposition. Although mutations in two genes, CDKN2A and CDK4, have been shown to confer an increased risk of CMM, they account for only 20%-25% of families with multiple cases of CMM. Therefore, to localize additional loci involved in melanoma susceptibility, we have performed a genomewide scan for linkage in 49 Australian pedigrees containing at least three CMM cases, in which CDKN2A and CDK4 involvement has been excluded. The highest two-point parametric LOD score (1.82; recombination fraction [theta] 0.2) was obtained at D1S2726, which maps to the short arm of chromosome 1 (1p22). A parametric LOD score of 4.65 (theta=0) and a nonparametric LOD score of 4.19 were found at D1S2779 in nine families selected for early age at onset. Additional typing yielded seven adjacent markers with LOD scores >3 in this subset, with the highest parametric LOD score, 4.95 (theta=0) (nonparametric LOD score 5.37), at D1S2776. Analysis of 33 additional multiplex families with CMM from several continents provided further evidence for linkage to the 1p22 region, again strongest in families with the earliest mean age at diagnosis. A nonparametric ordered sequential analysis was used, based on the average age at diagnosis in each family. The highest LOD score, 6.43, was obtained at D1S2779 and occurred when the 15 families with the earliest ages at onset were included. These data provide significant evidence of a novel susceptibility gene for CMM located within chromosome band 1p22.

Adolescent↗

Comparison of measurements of refractive errors between the hand-held Retinomax and on-table autorefractors in cyclopleged and noncyclopleged children.

PURPOSE: To compare the measurement of refractive errors (sphere, cylinder, and axis) between the hand-held Retinomax and on-table Topcon autorefractors in cyclopleged and noncyclopleged young children. The average bias and measurement agreement were assessed. DESIGN: Observational cross-sectional study. METHODS: The study included 114 cyclopleged and 156 noncyclopleged young children. The mean difference between the two methods and the 95% limits of agreement were calculated to evaluate the average bias. Two types of analyses were conducted to assess the degree of agreement. First, the proportion of the absolute mean differences was presented in different ranges ( 1.0 diopters for sphere and cylinder; 0-10, 11-20 and >20 degrees for axis). Second, the paired t test was conducted to evaluate the consistency of two types of measurements. RESULTS: The data by the Retinomax had mild bias (0.59 diopters) toward a lower sphere data under noncycloplegia but no bias under cycloplegia. For cylinder and axis, there was either no bias or clinically acceptable bias (0.02-0.13 diopters for cylinder and 2-7 degrees for axis) regardless of cycloplegia. Besides the sphere data under noncycloplegia, in general 90% of the mean differences of sphere and cylinder were within 0.5 diopters. More than 97% of the difference in axis under cycloplegia and 68% under noncycloplegia were within 20 degrees. After adjusting for mild bias, the paired t test showed very consistent results. CONCLUSIONS: The data by the Retinomax were consistent with those by the Topcon. The Retinomax is a useful instrument to screen refractive errors in young children.

Child↗