Search PubMed⌕ Search

Biomedical subjects

Nabil A Ebraheim

Publications and source records attributed to Nabil A Ebraheim.

28 records · Page 2Linked to original sources

Open reduction and internal fixation of 117 tibial plateau fractures.

This retrospective study evaluated the surgical management of 117 tibial plateau fractures treated between 1990 and 1998. At last patient follow-up, results were rated good to excellent in 94, fair in 13, and poor in 10 cases. Follow-up radiographs showed degenerative changes in the lateral compartment in 29 cases. Other complications included five wound infections, two deep venous thromboses, five delayed unions, and three nonunions. Operative treatment of tibial plateau fractures is recommended as it enables better alignment, meniscal access, and other soft-tissue injury repair.

Adolescent↗

Percutaneous computed tomographic stabilization of the pathologic sacroiliac joint.

Metastases to the sacroiliac joint region can be a source of significant pain in many patients who are terminally ill. Six patients with metastatic lesions in the sacroiliac region who presented with significant posterior pelvic pain were treated with computed tomography-guided insertion of iliosacral screws. All patients reported excellent pain control in the early postoperative period. Computed tomography-guided insertion of iliosacral screws in an area of relatively preserved bone stock provides good purchase of the screws. It is a safe percutaneous procedure and it helps alleviate pain in patients with sacroiliac metastases.

Aged↗

Syndesmotic disruption in low fibular fractures associated with deltoid ligament injury.

Low fibular fractures that were associated with deltoid ligament disruption and inferior tibiofibular syndesmotic disruption were studied. All of the patients had a Type B Weber fibular fracture associated with a deltoid ligament injury. It was difficult to detect the syndesmosis disruption on the initial assessment of the anteroposterior and mortise radiographs obtained preoperatively because there was no obvious talar shift on the plain radiograph. Careful evaluation of the plain radiograph and determination of all the recommended measurements were necessary to diagnose the syndesmotic disruption. However, the syndesmotic disruption was easily recognizable on axial computed tomography scans when comparing the injured and the noninjured sides. Axial computed tomography scans also showed a shallow incisura fibularis in all patients and in three cases it revealed anterior fibular subluxation that was not appreciated on the plain radiographs obtained preoperatively. On the basis of the current study using the level of the fibular fracture as a guideline for application of the syndesmotic screw as suggested by some authors may not be accurate. There are several factors that should be considered including the depth of the incisura fibularis, posterior malleolus fractures, deltoid ligament injury, and subluxation of the fibula. The surgeon's impression in the operating room of syndesmosis stability should be considered as the best guideline in the application of syndesmosis fixation rather than depending on the level of the fibular fracture.

Adult↗

The tibialis anterior used as a local muscle flap over the tibia after soft tissue loss.

BACKGROUND: A series of 12 extremities among 11 patients with open wounds exposing the tibia were treated using a local tibialis anterior muscle flap. There was an associated tibial shaft fracture in 11 of the 12 extremities, which were managed by external fixation or intramedullary nailing. The wounds, ranging from 1 to 15 cm in length, were located anteriorly over the middle and distal thirds of the tibia. METHODS: A retrospective chart review included patients whose open anterior tibial wounds were managed with an anterior tibialis rotational flap. These patients had been treated at the Medical College of Ohio between 1995 and 1999. No patients were excluded, and all the patients had at least 1 year of follow-up evaluation. RESULTS: Complete coverage was obtained in all cases. All the wounds healed without complication. All the associated tibial shaft fractures had a delayed union or nonunion, with 10 of the 11 requiring bone graft or an exchange intramedullary nail. CONCLUSION: The anterior tibialis is a relatively easy flap to use for covering anterior tibial open wounds. The high rate of nonunion seems related more to the injury than to the coverage technique.

Adult↗

Dynamic changes in the contact area of the sacroiliac joint.

Thirty adult dry-bone ilium specimens were used in conjunction with computer analysis to determine the average articular contact area between the sacrum and ilium at the sacroiliac joint. Simulating an unstable pelvic injury, the sacroiliac joint was displaced in three directions by moving the ilium posteriorly, superiorly, and posterosuperiorly. After each displacement, the contact area between the sacrum and ilium at the sacroiliac joint was calculated. The data showed that the average articular surface area of the male sacroiliac joint (1138.3 mm2) was approximately 12.8% greater than the average surface area of the female sacroiliac joint (992.5 mm2). The average articular contact area between the sacrum and ilium at the sacroiliac joint was lowest with the ilium displaced posterosuperiorly compared to equal displacements superiorly or posteriorly. This study quantitatively illustrated the loss of contact surface area between the sacrum and ilium during various displacements of the ilium, thus indicating the clinical cross-section area available for open reduction and internal fixation or fusion.

Adult↗

Extensor hallucis longus innervation: an anatomic study.

Thirty legs from skeletally mature embalmed cadavers were dissected to define the most common pattern and the variants of innervation of the extensor hallucis longus muscle and its clinical significance. Twenty-seven muscles had only one innervating branch (90%). Only three muscles had two innervating branches (10%). Twenty-one of the branches entered the muscles from the fibular side (63.6%), six entered the muscles from the tibial side (18.2%), and six entered the muscles from the anterior edge (18.2%). The branches innervating the extensor hallucis longus from the fibular side had a closer relation with the fibular periosteum than those entering the muscle from the tibial side or the anterior edge. The mean length of these branches between their points of origin and entry in the extensor hallucis longus was 5.0 +/- 1.5 cm. The high risk zone for the iatrogenic injury to the muscular branch of the extensor hallucis longus was located between 5.9 +/- 1.7 and 10.9 +/- 1.7 cm inferior to the most distal palpable point of the fibular head. The current study confirmed that the extensor hallucis longus was supplied mostly by one nerve that usually entered the muscle from the fibular side and had a close relation to the fibular periosteum in the dangerous zone.

Cadaver↗

Vulnerability of the spinal accessory nerve in the posterior triangle of the neck: a cadaveric study.

Injury to the accessory nerve results in an obvious shoulder droop, loss of shoulder elevation, and pain. Prevention of inadvertent injury to the accessory nerve is critical in neck dissection. No previous study, however, anatomically demonstrates the mechanism of the spinal accessory nerve traction injury. Anatomic determination of the location and course of the spinal accessory nerve may be helpful for a better understanding of the mechanism of the nerve injury. The accessory nerve courses obliquely across the posterior triangle on the surface of the levator scapula muscle and reaches the trapezius. The length of the spinal accessory nerve in the posterior triangle is 34.7+/- 6.3 mm. The nerve passes through the posterior border of the sternocleidomastoid muscle 50.7+/- 12.9 mm below the tip of the mastoid process and reaches the anterior border of the trapezius 49.8 +/- 5.9 mm above the clavicle. It makes a posterior angle of 73.1 degrees +/- 19.4 degrees, on average, relative to the posterior border of the sternocleidomastoid. When the shoulder is pulled down and the head is turned to the opposite direction, the spinal accessory nerve is stretched in the posterior triangle. In the posterior triangle, the nerve is vulnerable, since it is superficial and covered only by skin and subcutaneous fascia. Therefore, extreme caution should be taken with any surgical procedures in the posterior triangle. Traction injury of the spinal accessory nerve in the posterior triangle cannot be ignored.

Accessory Nerve↗

Intramedullary fibular allograft and nail for treatment of femoral shaft nonunion.

We present a difficult case of hypertrophic nonunion associated with a large cavity in the lower third of the femur. The cavity had been created by a windshield-wiper effect after failure of fixation with a Schneider intramedullary rod in a patient weighing 450 pounds. Treatment consisted of exchanging the Schneider nail with a larger-diame-ter interlocking nail and using the intramedullary fibular allograft to fill the cavity. The fracture healed 4 months after the procedure. At 5-year follow-up, the patient had no complaint, and plain radiographs showed obliteration of the large cavity in the distal femur. Intramedullary fibular graft technique can be used as an adjunct to use of an intramedullary nail when the distal femur contains a large cavity or when the intramedullary rod does not provide adequate fixation stability.

Bone Nails↗

Value of intraoperative true lateral radiograph of C2 pedicle for C1-2 transarticular screw insertion.

BACKGROUND CONTEXT: Transarticular C1-2 screws are widely used in posterior cervical spine instrumentation. Injury to the vertebral artery during insertion of transarticular Cl-2 screw remains a serious complication. Use of a computer-assisted surgery system decreases this complication considerably. However, this system encounters problems in ensuring complete accuracy because of positional variations during preoperative and intraoperative imaging generation. Therefore, intraoperative fluoroscopy still is one of the commonly used methods to guide insertion of transarticular Cl-2 screw. Evaluation of a true lateral radiographic view of the C2 pedicle for screw trajectory during C1-2 transarticular screw insertion may help to minimize this potential complication. PURPOSE: To evaluate the value of intraoperative true lateral radiograph of the C2 pedicle for screw trajectory during C1-2 transarticular screw insertion. STUDY DESIGN: To compare the height of the C2 pedicle area allowing instrumentation on true lateral view radiograph of the C2 pedicle and computed tomographic (CT) scan with multiplanar reconstruction. METHODS: Twenty embalmed human cadaveric cervical spine specimens were used to insert a total of 40 C1-2 transarticular screws using Magerl and Seemann technique. One side of the C2 transverse foramen was filled with radiopaque material (lead oxide) to simulate the artery and to demarcate the danger zone for better visualization on radiography. Measurements and calculation of the mean and standard deviation of the height of the area allowing instrumentation of the C2 pedicle were done on true lateral view radiograph of the C2 pedicle, the sagittal and 30 degrees sagittal views relative to the frontal plane passing exactly through the center of the C2 pedicle of CT scans. Student t test was applied to calculate the statistical significance of measured values. Statistical significance was defined as p or=.36. Using sagittal CT scan views, the height of pedicles was 7.71+/-0.7 mm (right) and 7.58+/-1.01 mm (left), p>or=.23. On 30 degrees sagittal CT scan views, the height of pedicles was 7.84+/-1.00 mm (right) and 7.76+/-1.02 mm (left), p>or=.27. The p value was >or=.78, >or=.56, and >or=.49 for true lateral radiographic view and sagittal CT scan view, true lateral radiographic view and 30 degrees sagittal CT scan view, and sagittal CT scan view and 30 degrees sagittal CT scan views, respectively. On lateral view of cervical spine, the decline angle of the transarticular screw was 51.3+/-0.50 degrees (right) and 50.68+/-0.41 degrees (left), p>or=.17. Mean decline angle was 51+/-0.43 degrees . On the anteroposterior (AP) view, radiograph median angle was 6.87+/-0.53 degrees (right) and 6.0+/-0.59 degrees (left), p>or=.25. Mean median angle was 6.44+/-0.62 degrees. CONCLUSIONS: True lateral radiographic views of the pedicles provide useful information for defining screw trajectory intraoperatively. Using this view along with AP and lateral view of cervical spine and preoperative three-dimensional CT scan may narrow the margin of error in this delicate area.

Aged↗