Search PubMed⌕ Search

Biomedical subjects

Nabeel A Riza

Publications and source records attributed to Nabeel A Riza.

7 recordsLinked to original sources

Submicrosecond speed optical coherence tomography system design and analysis by use of acousto-optics.

A novel high-speed no-moving-parts optical coherence tomography (OCT) system is introduced that acquires sample data at less than a microsecond per data point sampling rate. The basic principle of the proposed OCT system relies on use of an acousto-optic deflector. This OCT system has the attractive features of an acousto-optic scanning heterodyne interferometer coupled with an acousto-optic (AO) variable optical delay line operating in a reflective mode. Fundamentally, OCT systems use a broadband light source for high axial resolution inside the sample or living tissue under examination. Inherently, AO devices are Bragg-mode wavelength-sensitive elements. We identify that two beams generated by a Bragg cell naturally have unbalanced and inverse spectrums with respect to each other. This mismatch in spectrums in turn violates the ideal autocorrelation condition for a high signal-to-noise ratio broadband interferometric sensor such as OCT. We solve this fundamental limitation of Bragg cell use for OCT by deploying a new interferometric architecture where the two interfering beams have the same power spectral profile over the bandwidth of the broadband source. With the proposed AO based system, high (e.g., megahertz) intermediate frequency can be generated for low 1/f noise heterodyne detection. System issues such as resolution, number of axial scans, and delay-path selection time are addressed. Experiments described demonstrate our high-speed acousto-optically tuned OCT system where optical delay lines can be selected at submicrosecond speeds.

Acoustics↗

Angstrom-range optical path-length measurement with a high-speed scanning heterodyne optical interferometer.

A highly accurate method of optical path-length measurement is introduced by use of a scanning heterodyne optical interferometer with no moving parts. The instrument has demonstrated the potential to measure optical path length at angstrom resolution over continuous thickness in the micrometer range. This optical path length can be used to calculate the thickness of any material if the refractive index is known or to measure the refractive index of the material if the thickness is known. The instrument uses a single acousto-optic device in an in-line ultra-stable reflective geometry to implement rapid scanning in the microsecond domain for thickness measurements of the test medium.

Journal Article↗

Programmable high-speed polarization multiplexed optical scanner.

A fast digital-analog control polarization-based optical scanner with complete three-dimensional beam-forming programmability is described. Its features include low power consumption and large-aperture liquid-crystal-based optics, digital repeatability, and time-multiplexed accurate analog beam forming. Analog frequency and amplitude control of the nematic liquid-crystal beam-former cells permits continuous fine-scan programmability over a 0.66-mrad horizontal deflection, a 0.75 mrad vertical deflection, and an infinity-to-1.84-m focal-length longitudinal scan. First demonstrations included an 8-point volumetric scan and a 2-bit digital lens scan, both at 1310 nm, with a 35-micros random-access time.

Journal Article↗

Code-multiplexed optical scanner.

A three-dimensional (3-D) optical-scanning technique is proposed based on spatial optical phase code activation on an input beam. This code-multiplexed optical scanner (C-MOS) relies on holographically stored 3-D beam-forming information. Proof-of-concept C-MOS experimental results by use of a photorefractive crystal as a holographic medium generates eight beams representing a basic 3-D voxel element generated via a binary-code matrix of the Hadamard type. The experiment demonstrates the C-MOS features of no moving parts, beam-forming flexibility, and large centimeter-size apertures. A novel application of the C-MOS as an optical security lock is highlighted.

Journal Article↗

Foundations for low-loss fiber gradient-index lens pair coupling with the self-imaging mechanism.

A fiber-optic collimator that emits a Gaussian beam with its beam waist at a certain distance after the exit face of the lens is labeled a self-imaging collimator. For such a collimator, the waist of the emitted Gaussian beam and its location are partly dependent on the properties of the gradient-index (GRIN) lens. Parameters for the self-imaging collimator are formulated in terms of the parameters of a GRIN lens (e.g., pitch, core refractive index, gradient index, length) and the optical wavelength. Next, by use of the Gaussian beam approximation, a general expression for the coupling power loss between two self-imaging-type single-mode fiber (SMF) collimators is, for the first time to our knowledge, derived as a function of three types of misalignment, namely, separation, lateral offset, and angular tilt misalignment. A coupling experiment between two self-imaging collimators with changing separation distance is successfully performed and matches the proposed self-imaging mechanism coupling loss theory. In addition, using a prism, lateral offset, as well as angular tilt, misalignments are experimentally simulated for a two self-imaging collimator coupling condition by a single collimator reflective test geometry. Experimental results agree well with the proposed loss formulas for self-imaging GRIN lenses. Hence, for the first time to our knowledge, the mathematical foundations are laid for employing self-imaging-type fiber collimators in SMF-based free-space systems allowing optimal design for ultra-low-loss coupling.

Journal Article↗

Free-space wavelength-multiplexed optical scanner demonstration.

Experimental demonstration of a no-moving-parts free-space wavelength-multiplexed optical scanner (W-MOS) is presented. With fast tunable lasers or optical filters and planar wavelength dispersive elements such as diffraction gratings, this microsecond-speed scanner enables large several-centimeter apertures for subdegree angular scans. The proposed W-MOS design incorporates a unique optical amplifier and variable optical attenuator combination that enables the calibration and modulation of the scanner response, leading to any desired scanned laser beam power shaping. The experimental setup uses a tunable laser centered at 1560 nm and a 600-grooves/mm blazed reflection grating to accomplish an angular scan of 12.92 degrees as the source is tuned over an 80-nm bandwidth. The values for calculated maximum optical beam divergance, required wavelength resolution, beam-pointing accuracy, and measured scanner insertion loss are 1.076 mrad, 0.172 nm, 0.06 mrad, and 4.88 dB, respectively.

Journal Article↗

Micro-electro-mechanical system-based digitally controlled optical beam profiler.

An optical beam profiler is introduced that uses a two-dimensional (2-D) small-tilt micromirror device. Its key features include fast speed, digital control, low polarization sensitivity, and wavelength independence. The use of this 2-D multipixel device opens up the important possibility of realizing several beam profile measurement concepts, such as a moving knife edge, a scanning slit, a moving pinhole, a variable aperture, and a 2-D photodiode array. The experimental proof of the optical beam profiler concept using a 2-D digital micromirror device to simulate the 2-D moving knife edge indicates a small measurement error of 0.19% compared with the expected number based on a Gaussian beam-propagation analysis. Other 2-D pixel arrays such as a liquid-crystal-based 90 degrees polarization rotator sandwiched between crossed polarizers can also be exploited for the optical beam whose polarization direction is known.

Journal Article↗