Cervical vertebral strain measurements under axial and eccentric loading.

The mid to lower cervical spine is a common site for compression related injury. In the present study, we determined the patterns of localized strain distribution in the anterior aspect of the vertebral body and in the lateral masses of lower cervical three-segment units. Miniature strain gages were mounted to human cadaveric vertebrae. Each preparation was line-loaded using a knife-edge oriented in the coronal plane that was moved incrementally from anterior to posterior to induce compression-flexion or compression-extension loading. Uniform compressive loading and failure runs were also conducted. Failure tests indicated strain shifting to "restabilize" the preparation after failure of a component. Under these various compressive loading vectors, the location which resulted in the least amount of deformation for a given force application (i.e., stiffest axis) was quantified to be in the region between 0.5- 1.0 cm anterior to the posterior longitudinal ligament. The location in which line-loading produced no rotation (i.e., balance point) was in this region; it was also close to where the vertebral body strains change from compressive to tensile. Strain values from line loading in this region produced similar strains as recorded under uniform compressive loading, and this was also the region of minimum strain. The region of minimum strain was also more pronounced under higher magnitudes of loading, suggesting that as the maximum load carrying capacity is reached the stiffest axis becomes more well defined.

Aged↗

An experimental technique to induce and quantify complex cyclic forces to the lumbar spine.

The human spine is a complex, heterogeneous nonlinear and viscoelastic structure. In addition, in vivo loading is not uniaxial. Although many studies on the mechanical behavior of the spine under "pure" forces and single cycle load applications exist, little research is conducted with complex cyclic loads. In this study, we developed a technique to induce and quantify controlled complex physiological loads to the lumbar spinal column under cyclic (chronic) conditions. The methods described include specimen preparation and mounting to induce controlled complex loading (cyclic compression-flexion vector was chosen as an example), instrumentation, and biomechanical data to achieve the objectives. The results indicated that the specimen sustained the external load in a combined compression-flexion mechanism without considerable off-axis forces (lateral shears) and moments (lateral bending and torsion). By mounting the anchoring bolt in appropriate places (such as an anterolateral placement to induce compression-flexion-lateral bending), this technique can be used to apply and continuously quantify complex physiological acute or cyclic loads to describe the biomechanics of the spine. This procedure of inducing complex loads eliminates the difficulty in applying the principles of superposition, using the response from individual "pure" forces to account for the nonlinearity and viscoelasticity of the human lumbar spinal column.

Biomechanical Phenomena↗

Rotational stability of a spinal pedicle screw/rod system.

Although the geometry of spinal instrumentation constructs may significantly affect efficacy, the variation in biomechanical data may not assist the clinician in an appropriate selection. The purpose of the present study was to quantify the effects of transverse fixators on rotational strength of a common pedicle-screw-with-rods system. Pedicle screws were mounted in blocks of polymethyl-methacrylate at angles to reproduce the configuration of placement in the human lumbar spine. Twenty cycles of +/- 12 N-m axial rotation moment was applied, and the steady-state response was used in the analysis. Configurations tested included both medial and lateral placement of longitudinal rods as well as the addition of one or two transverse rods. Up to a 20% difference in stiffness was noted between medial and lateral placement of longitudinal rods when no transverse rods were mounted. A maximum difference in flexibility of 6% was noted between the use of one and two transverse rods. For medially placed rods, a single transverse connector will add significant rotational stiffness even for shorter rod lengths; for laterally placed longitudinal rods, only the longer rod lengths need a transverse connector.

Bone Nails↗

Fusion rate and biomechanical stiffness of hydroxylapatite versus autogenous bone grafts for anterior discectomy. An in vivo animal study.

STUDY DESIGN: The fusion rate and biomechanical stiffness were evaluated for 56 goat spinal units from 14 animals that had anterior discectomies and grafting procedures completed using hydroxylapatite and autogenous bone and survived for 6, 12, and 24 week healing times. OBJECTIVES: Harvested spinal units underwent radiographic imaging to assess fusion, biomechanical testing in axial compression, flexion, extension, lateral bending, and axial rotation to assess strength, and histological analysis. The above results were compared for the two procedures and the different healing times. SUMMARY OF BACKGROUND DATA: Because of some of the complications associated with the use of autogenous iliac crest bone graft in spine fusions, there has been considerable interest in the use of calcium phosphate ceramics as a possible substitute for a grafting material. One of the attractive features of calcium phosphate ceramics is the resulting strong bond that is formed with the host bone unlike other inert compounds. METHODS: Surgeries were done at four sites on each animal with two in the cervical spine and two in the lumbar spine. Radiography was done during the survival time and postsacrifice. Biomechanical testing was done on the day of sacrifice under physiological loads. Both hard tissue sections and decalcified sections were histologically evaluated. RESULTS: A 55% fusion rate for bone preparations and a 50% fusion rate for the hydroxylapatite (HA) units was found for the 12 and 24 week preparations. The HA preparations were better at maintaining disc space height. The biomechanical analysis revealed significantly higher stiffness values for fused preparations than for nonfused samples under extension, lateral bending, and axial rotation. Fused units demonstrated no statistical difference in biomechanical stiffness between HA versus autogenous bone units for any mode of loading. CONCLUSIONS: Our results indicate that these dense, nonresorbable hydroxylapatite blocks perform as well as autogenous bone for anterior spinal fusions in this animal model. The use of this hydroxylapatite material in anterior spine fusions may have some clinical validity.

Animals↗

Cyclic compression-flexion loading of the human lumbar spine.

STUDY DESIGN: The present study was designed to investigate the biomechanical behavior of the lumbar spine under controlled complex physiologic situations with chronic input. OBJECTIVE: The objective was to determine the response of the human cadaver lumbar spinal column under repetitive compression-flexion forces. SUMMARY OF BACKGROUND DATA: Studies have been conducted in the past to determine the biomechanical response of the spine under uniaxial or pure forces. There is no methodology that can be used to apply and continuously quantify the fatigue response of the lumbar spinal column under controlled combined complex loading vectors (e.g., compression flexion). METHODS: Intact cadaver lumbar columns (L1-L5) were mounted with the superior end in contact with a ball-transfer mount, inducing a flexion load to the spine while allowing multiple degrees of freedom. The distal portion of the specimen was attached to a six-axis load cell to quantify the force sustained by the specimen during the entire loading cycle. The applied load and piston deformation and the generalized six-axis force histories were gathered as a function of time using a digital data acquisition system. RESULTS: The stiffness versus number of cycles (K-N) response exhibited nonlinear characteristics. The stiffness increased initially and then stabilized after 1,000-2,000 cycles of loading, delineating the viscoelastic characteristics of the spine. The initial stiffness increase before stabilization was found to be significantly different (P < 0.025) compared to the stiffness beyond 2,000 cycles. CONCLUSIONS: The data suggest that the fatigue response can be understood by cyclically loading the ligamentous lumbar spine preparation to approximately 2,000 cycles.

Aged↗

Correlation of microtrauma in the lumbar spine with intraosseous pressures.

This study was conducted to determine the relationship between intraosseous pressure and vertebral microtrauma in the lumbar spine. Functional spinal units were excised from human cadavers. Radio-opaque dye was injected into the nucleus. Miniature transducers were inserted into the vertebrae to record intraosseous pressures. Compressive loading was applied quasistatically (2 mm/sec) until injury occurred. Movement of the contrast medium was monitored under fluoroscopy. The subchondral endplate was the most vulnerable component for initiation of injury to the lumbar spine segment. In the initial stages of loading, the vertebral endplates gradually bulged outward, with the contrast medium staying within the nucleus. However, at higher physiologic load levels, before reaching the limiting load, the deformations increased, resulting in buckling of one of the endplates. This was followed by the contrast medium impregnating the spongiosa. Microlevel trauma was not observed radiographically after load removal, indicating that one cannot always equate a normal radiograph with normal spinal anatomy. Mean forces, deformations, stiffnesses, energies, and strains were 7.8 kN (+/- 1.4), 5.23 mm (+/- 0.78), 1940 N/mm (+/- 226), 18.7 J (+/- 4.4), and 35.5% (+/- 3.7), respectively. Pressure in the vertebral body containing the injured endplate before the onset of microtrauma was different (P < 0.05) from the pressure after injury; the pressures in the body containing the intact endplate, however, were not statistically different. Significant differences (P < 0.05) in the intraosseous pressures occurred between the two spinal levels at low-level physiologic loads before the onset of microtrauma.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Intravertebral pressure changes caused by spinal microtrauma.

Clinical studies indicate variations in intravertebral pressures in patients with and without low back pain. It is known that not all patients with back pain have abnormal lumbar radiographs and, furthermore, microfractures of the endplate may be one of the causes in the origin of low back pain. Consequently, this study was conducted to determine the interrelationship between microtrauma and intraosseous pressures in the lumbar spine. Miniature pressure transducers were inserted into the vertebral bodies and spinous processes of human cadaver spinal units. Radio-opaque medium was injected into the nucleus to fluoroscopically monitor the movement of the fluid from the disc as the preparation was loaded up to the initiation of microtrauma (before reaching the ultimate load-carrying capacity). The onset of injury was evidenced by the microfracture of one of the two endplates and impregnation of the contrast medium into the spongiosa. After relaxation, another cycle of loading was applied by limiting the deflections to the maximum compression sustained under the intact configuration. The load, stiffness, and energy-absorbing capacities were lower (P < 0.05) for the injured specimen compared with the intact configuration. The intraosseous pressures were higher (P < 0.05) in the vertebral body and the spinous process of the vertebra where the endplate exhibited microtrauma in the injured cycle compared with the intact cycle. In contrast, the intraosseous pressures in the vertebral body and the spinous process at the level where the endplate remained intact were not significantly different between the two cycles of loading.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Continuous motion analysis of the head-neck complex under impact.

The objective of the present study was to analyze the localized kinematic biodynamics of the human head-neck complex under impact loading. Unembalmed human cadaveric head-neck complexes were subjected to axial compressive forces delivered using an electrohydraulic testing device. The head-neck complex was aligned along the stiffest-axis; musculature was simulated using preloaded springs and cables; and retroreflective targets were inserted into the vertebral body, the facet joint articulation, and the spinous process at every level of the cervical column. At dynamic loading rates (1.8-5.1 m/min), mid to lower cervical spine injuries consistently occurred in these preparations. Continuous motion analysis of the components (vertebral body, intervertebral disk, facet joint, and the spinous process) at all levels of the cervical spine showed the temporal order of the transfer of the external load. Injuries documented by computed tomography and cryomicrotomy techniques correlated with the kinematics of the structure. The application of dynamic loading to the head-neck complex coupled with high-speed, continuous-motion analysis of the intervertebral components of the entire cervical column makes possible the definition of the temporal kinematic mechanics that are fundamental to the understanding of the biodynamics of cervical spine trauma. Using these procedures, we have correlated the kinematics with the onset and pattern of neck injury secondary to impact forces.

Aged↗

Kinematics of the lumbar spine following pedicle screw plate fixation.

This investigation was conducted to determine the kinematic response of the lumbar spine instrumented with transpedicular screws and plates. Seven unembalmed human cadaveric lumbar spines were used. Retroreflective targets were inserted into the bony landmarks of each vertebral body, facet column, and spinous process. The specimen was quasistatically loaded until failure (initial cycle) using an electrohydraulic testing device at a rate of 2.5 mm/sec. After radiography, the specimen was again loaded (injury cycle) to the failure compression determined in the previous cycle. Transpedicular screws then were inserted bilaterally at one level proximal and distal to injury. The stabilized cycle of loading was conducted using the procedure adopted in the injury cycle. Comparative analysis of the localized kinematic data between the stabilized and injured columns indicated a reduction in motion between fixated levels, increasing the rigidity of the column. At levels proximal and distal to fixation, however, motion increased, indicating added flexibility. These alterations in the motion, observed during single-cycle loading, may be further accentuated in vivo, leading to hypermobility and degeneration of the spine.

Adult↗

A biomechanical impact test system for head and facial injury assessment and model development.

A biomechanical test system has been developed and validated to conduct controlled uniaxial impact experiments of head and facial trauma. The design reduces off-axis accelerations which are not in the direction of impact and allows accurate positioning of test specimens. Impact forces, displacement histories, impulses at impact and spectral responses are compared to free-fall test results at contact velocities representative of facial injuries (2.5, 3.1 and 3.8 m s-1). Models based on the experimental results are developed to reveal stiffness and inertial properties of impact for use in the design of biomechanically protective steering wheels, air bags and other potential impact structures. The results indicate that the system provides a flexible yet controllable method for positioning and testing impact structures reliably.

Accidents, Traffic↗

Effects of anterior vertebral grafting on the traumatized lumbar spine after pedicle screw-plate fixation.

This study was conducted to determine the effects of corpectomy and anterior strut grafting on the biomechanics of traumatized lumbar spine after pedicle screw-plate fixation. Eight lumbar spines were loaded until fracture (initial cycle) and then reloaded to the same deformation (injury cycle). After transpedicular fixation, spines were again loaded (fixation cycle). Partial corpectomy of the fractured body and anterior strut grafting were accomplished; the spine reloaded (strut cycle). Spine angles were measured and biomechanical strength and kinematic parameters analyzed. Load-deformation relationships were similar for fixation and strut cycles until maximum load; at failure, loads were higher for the former (P < 0.05), however. Alignment was improved by stabilization or stabilization plus anterior grafting (P < 0.05). Vertebral height was best maintained by grafting as an adjunct to pedicle fixation (P < 0.05). Kinematics were largely unaffected by grafting, except for reduced motion at the posterior vertebral targets between the fixated levels (P < 0.05). The strength of the fixated spine is relatively unchanged by corpectomy and anterior grafting; alignment may be improved in the latter group.

Biomechanical Phenomena↗

Biomechanical effects of laminectomy on thoracic spine stability.

Thoracic columns (T1-L1 levels) from 15 fresh human cadavers were used to quantify alterations in the biomechanical response after laminectomy. Eight specimens were tested intact (Group I); the remaining seven preparations were tested after two-level laminectomy (Group II) at the midheight of the column. All specimens were fixed at the proximal and distal ends and loaded until failure. Force and deformation were collected by use of a data acquisition system. Failure of the Group I specimens included compressive fractures with or without posterior element distractions, generally at the midheight of the column. Group II preparations failed at the superior aspect of laminectomy or at a level above laminectomy, suggesting an increased load sharing. Biomechanical responses of the Group II preparations were significantly different (P < 0.05) from those of the Group I specimens at deformations from the physiological to the failure range. In addition, failure forces for Group II preparations were significantly lower (P < 0.001) than for Group I specimens. The stiffness and energy-absorbing capacities of the laminectomized specimens were also significantly different (P < 0.05) from those of the intact columns. In contrast, the deflections at failure for the two groups were not statistically different, suggesting that the human thoracic spine is deformation sensitive. Our data demonstrate that a two-level laminectomy decreases the strength and stability of the thoracic spine throughout the loading range. Although this is not a practical concern with an otherwise intact vertebral column, laminectomy, when other abnormalities such as vertebral fracture, tumor, or infection exist, may require stabilization by fusion and instrumentation.

Adult↗

Biomechanical evaluation of Caspar cervical screws: comparative stability under cyclical loading.

Anterior cervical instrumentation is used as an adjunct to bone fusion; however, definitive biomechanical data to support some applications and techniques are lacking. In the absence of supportive experimental data, posterior cortical penetration has been recommended with the Caspar system. Previously, we compared the axial pull-out strength of Caspar screws with and without posterior cortical penetration. This study compares the stability of unicortical versus bicortical screw penetration groups under cyclical loading simulating physiological flexion-extension. Caspar screws were placed in human cadaveric vertebrae with or without posterior cortical purchase. Each screw was separately tested, simulating flexion-extension to 200 cycles. Deformation time data allowed a direct comparison of screw "wobble" with and without posterior cortical purchase. The mean deformation differences between subcortical and bicortical groups were statistically significant and increased over time within both groups. Enhanced stability was noted with bicortical purchase throughout most of the examined range, becoming more pronounced over longer periods of cyclical loading. Significant (P < 0.05) increases in deformation over time were noted for both groups, suggesting potentially significant deterioration at the screw-bone interface, despite bicortical purchase. Such deterioration with repeated flexion-extension loading may be of concern in the use of Caspar plates in the presence of multicolumn instability.

Absorptiometry, Photon↗

Energy absorption characteristics of football helmets under low and high rates of loading.

The purpose of this study was to examine the force-deformation characteristics of football helmets subjected to compressive loading on the crown surface. Tests were conducted at quasi-static and dynamic rates of loading. Energies were computed from the force-deformation data. The padding systems represented by the helmets differed in their ability to absorb energy under varying loading rates. Helmets using pneumatic or combination pneumatic-foam padding systems were the most successful while suspension helmets were able to absorb the least amount of energy. The evaluation of energy absorption characteristics is an alternative method of describing the effectiveness of football helmets in preventing head injury.

Acceleration↗

Biomechanical properties of human lumbar spine ligaments.

Biomechanical properties of the six major lumbar spine ligaments were determined from 38 fresh human cadaveric subjects for direct incorporation into mathematical and finite element models. Anterior and posterior longitudinal ligaments, joint capsules, ligamentum flavum, interspinous, and supraspinous ligaments were evaluated. Using the results from in situ isolation tests, individual force-deflection responses from 132 samples were transformed with a normalization procedure into mean force-deflection properties to describe the nonlinear characteristics. Ligament responses based on the mechanical characteristics as well as anatomical considerations, were grouped into T12-L2, L2-L4, and L4-S1 levels maintaining individuality and nonlinearity. A total of 18 data curves are presented. Geometrical measurements of original length and cross-sectional area for these six major ligaments were determined using cryomicrotomy techniques. Derived parameters including failure stress and strain were computed using the strength and geometry information. These properties for the lumbar spinal ligaments which are based on identical definitions used in mechanical testing and geometrical assay will permit more realistic and consistent inputs for analytical models.

Adult↗

The biomechanics of lumbar facetectomy under compression-flexion.

Alterations of posterior spinal elements including the facet joints are commonly associated with a variety of lumbar operative procedures. Under continuous physiologic compression-flexion load application L2-L3 and L4-L5 functional units were tested as intact preparations and then sequentially altered with unilateral facetectomy, bilateral facetectomy, posterior ligament transection, and partial discectomy. Using a method of continuous motion analysis, the movement of the individual spinal components (disc, facet joint, interspinous process distance) were statistically compared between the various surgical alterations. Higher physiologic loads produced significant increases in overall deflection from BF to BFL alterations indicating a preference to preserve the posterior ligaments for this surgical approach. Although insignificant changes in the force-deflection response from one surgical alteration to the next sequential alteration were noted, statistically significant increases in localized facet joint motion may suggest the potential for acceleration of segmental degenerative changes.

Aged↗

Pull-out strength of Caspar cervical screws.

Anterior cervical instrumentation as an adjunct to bone fusion has an important role in cervical spine surgery. Posterior vertebral body cortex purchase is strongly recommended in the use of the Caspar system, although few biomechanical data exist to validate this requirement. In this study, Caspar screws were placed in 43 human cadaveric cervical vertebral bodies, either putting them into the posterior vertebral cortex as identified radiographically or penetrating it by 2 mm as recommended in the literature. Pull-out tests were conducted with tension applied to a connected plate at 0.25 mm/s, and force-deformation data were obtained. Failure typically occurred with clean pull-out; in most instances, cancellous bone remained attached to screw threads. Mean load without posterior cortical purchase was 375 +/- 53 N; with penetration it was 411 +/- 70 N. These differences were nonsignificant. Average deformation to failure was 1.41 +/- 0.10 mm in the group without posterior cortical penetration. In the posterior penetration group, mean deformation was 1.56 +/- 0.16 mm. Again, differences were not significant. Posterior cortical penetration does not improve the pull-out strength of Caspar screws in an isolated vertebral body model, but other biomechanical studies need to be done before insertion methods are altered.

Biomechanical Phenomena↗