Clinical experience with heat sterilization for reprocessing dialyzers.

Use of heat sterilization for dialysis reprocessing offers significant advantages over chemical germicides. Polysulfone dialyzers (Fresenius 60M or 80M) can be sterilized by heating to 105 degrees C for 20 hr, thus permitting clinical trials of this method. One hundred eighty patients received 9,000 treatments. Pyrogenic reactions, sepsis, and subjective symptoms have not occurred. In vitro clearances (Qb 500 ml/min, Qd 800 ml/min) at baseline and after 2-8 uses did not differ (340 +/- 29 vs. 352 +/- 4 ml/min, respectively). KoA determined in vivo did not decrease (baseline 709 +/- 131 vs. 7th use 632 +/- 50 ml/min). Kt/V for urea was not different in 18 patients treated with heat sterilized dialyzers over 6 months when compared with a baseline period with formaldehyde sterilized dialyzers (1.37 +/- 0.12 vs. 1.32 +/- 0.11 at similar time and blood flows). Mean use number was 7.4 (dialyzers limited to 11 uses). Of discarded dialyzers, 44% failed a bedside integrity test (blood side pressurized at > 400 mmHg for 1 min), 36% failed automated fiber bundle or pressure holding tests, 8% had a blood leak, and 12% reached 11 uses. Clinical blood leaks occur in < 0.5% of treatments. Heat sterilization is a safe and effective method of dialysis reprocessing, but quality control of the process is essential. Based on initial clinical experience, heat sterilization of dialyzers for reuse is a promising alternative to chemical disinfection.

Blood Urea Nitrogen↗

Measurement of access flow during hemodialysis using the constant infusion approach.

With reversed placement of blood lines and with a peripheral arteriovenous access, hemodialysis recirculation (R) consists of a local access component, and a central cardiopulmonary component that must be separated for the calculation of access flow (Qac) using indicator dilution principles. With indicator injections that follow constant infusion principles Qac = (1 - Rx)/(Rx(1 - CPR)) x (Qb,x - UFR), where Qb is the extracorporeal blood flow, where UFR is the ultrafiltration rate, and where the index x indicates reversed placement of blood lines. CPR, the amount of cardiopulmonary recirculation (CPR = Qac/CO) is determined from two recirculation measurements with correct (index n) and with reversed (index x) placement of blood lines CPR = Rn(1 - Rx)/Rx(1 - Rn) x (Qb,x - UFR)/Qb,n. Qac was measured in 11 hemodialysis (HD) patients using a thermodilution device tested in an in vitro set-up based on constant infusion principles. Mean Qac was 1.135 L/min and 1.054 L/min for measurements done early and late in dialysis. The coefficient of variation was +/-7.3% and +/-8.6%, respectively. Repeated measurements of access flow in HD patients showed good reproducibility (Qac.1 = 1.01*Qac.0, r2 = 0.98), with the regression line not different from the line of identity; however, in vivo results remain to be validated by an independent technique.

Arteriovenous Shunt, Surgical↗

New access device for hemodialysis.

A new subcutaneous device (Dialock; Biolink Corp., Middleboro, MA) provides vascular access to patients who currently require hemodialysis (HD). The device consists of a port-like valve, implanted subcutaneously below the clavicle, which provides a linear flow passage to two catheters placed in the right atrium via the jugular vein. The valve is accessed percutaneously with needle-cannulas that functionally convert the device to twin catheters for connecting the patient to the HD lines. Interdialytic patency is maintained using a standard heparin lock. The device has been implanted in 10 outpatients under local anesthesia, with almost immediate use for HD (median, 3 days) and has functioned successfully for more than 6 months (mean +/- SD, 4.0 +/- 1.7; > 400 dialysis sessions). Blood flows over 300 ml/min were consistently achieved (average, 320 +/- 50) with venous and arterial pressures of 197 +/- 42 mmHg and -241 +/- 31 mmHg, respectively. After 40 patient-months, condition of the needle puncture sites remains satisfactory. Four systemic infections have occurred in three patients; all have resolved without the need for device removal. There have been no infections at the puncture sites. One patient whose heparin lock was not changed for 23 days (for reasons unrelated to the device) required fibrin sheath stripping of his catheters. Patient and nurse acceptance has been excellent. The device may offer substantial improvement over conventional devices for HD access.

Adult↗

Validation of changes in extracellular volume measured during hemodialysis using a segmental bioimpedance technique.

Sum of segmental bioimpedance analysis (BIAs) has recently been introduced as a more accurate estimation of extracellular volume (ECV). The current study was designed to compare the changes in ECV estimated by whole body bioimpedance (BIA(W)) and BIAs and to determine whether BIAs could be used to accurately estimate changes in ECV compared with the ultrafiltration volume (UFV) as measured by the dialysis machine. Ten men (age, 49 +/- 10 years; dry weight, 78 +/- 13 kg) were studied during hemodialysis (HD). A multifrequency bioimpedance analyzer (BIS4000B; Xitron Technologies, San Diego, CA) and a digital switch developed by the authors were used to automatically collect data from three body segments (arm, trunk, and leg) and the whole body using the stated technique. There was a significant difference in delta ECV(W) and UFV at the end of the treatment (2.75 +/- 0.74 L vs 3.95 +/- 0.73 L, p < 0.05) because fluid removal from the trunk has almost no effect on whole body resistance. However, delta ECVs was not significantly different from UFV (3.76 +/- 0.65 L vs 3.95 +/- 0.73 L, p = NS). BIAs is a more accurate approach to monitor changes in ECV during HD than is BIA(W) because changes in local resistance can be allocated to segments with uniform geometry and resistivity. This is a prerequisite for future studies on dynamics of regional fluid distribution during hemodialysis.

Biophysical Phenomena↗

Predictive value of access blood flow in detecting access thrombosis.

The aim of this study was to evaluate whether repeated measurement of access blood flow (Qac) using the ultrasound dilution technique could predict access failure in patients on hemodialysis. One hundred thirty-one patients were evaluated at intervals of 8 weeks for a period of 6 months. The incidence of thrombosis was determined within each study period. During the 6 month follow-up, 36 thrombotic events occurred in 27 of 68 polytetrafluoroethylene (PTFE) grafts, and only six thrombotic events in 5 of 63 arteriovenous (AV) fistulas. The relative risk for access thrombosis for patients with PTFE grafts was 5.6 times greater than for patients with AV fistulas. Qac was significantly lower in thrombotic compared with patent PTFE grafts (958 +/- 506 ml/min vs 1141 +/- 482 ml/min, p < 0.05). A significant relationship was found between the incidence of subsequent PTFE graft thrombotic events and Qac (p < 0.001). Compared with accesses with high blood flow (1100-1400 ml/min), the risk for subsequent thrombosis tripled in grafts with a Qac of less than 500 ml/min. This relationship was not seen with AV fistulas. In patent PTFE grafts, Qac remained unchanged within each 2 month interval, whereas it decreased in thrombotic PTFE grafts. Thus, repeated measurements of Qac have the potential to predict future access failure in PTFE grafts; however, an increased measuring frequency might improve the predictive value of graft failure with high Qac.

Female↗

Exercise and extracorporeal blood cooling during hemodialysis.

Intradialytic exercise may improve hemodialysis efficiency. Because exercise interferes with thermal energy and fluid balance, relative blood volume changes (deltaBV%), arterial blood temperatures (T(art)), mean arterial blood pressures, and heart rates (HR) were measured using different dialysate temperatures (Tdia). Four stable patients (age, 49.9 +/- 7.7 years) were studied during 22 treatments that either maintained Tdia at 35.9 degrees C +/- 0.1 degrees C (standard) or provided maximum extracorporeal cooling (cool, Tdia = 34.8 degrees C +/- 0.8 degrees C) in attempts to maintain a constant T(art). Patients exercised for 1 hr at a resistance of 21 +/- 5 W on a stationary bicycle ergometer. Energy expenditure monitored by indirect calorimetry increased from 117 +/- 38 W (baseline) to 338 +/- 116 W (exercise). Mean arterial blood pressures increased by 7 +/- 7 mmHg with cool Tdia, but remained unchanged (-1 +/- 4 mmHg) with standard Tdia (p < 0.05). However, the increase in T(art) was smaller with cool (0.1 degrees C +/- 0.3 degrees C) than with standard (0.3 degrees C +/- 0.2 degrees C) Tdia (p < 0.05). The larger increase in O2 uptake per change in HR (68 +/- 56 vs 38 +/- 17 ml/beat) indicated an increase in stroke volume when cool dialysate was used (p = NS). Exercise produced a small (0.95% +/- 0.95%), but significant, decrease in deltaBV% that reversed at the end of exercise. Intradialytic exercise was well tolerated, especially when Tdia was lowered such that hemodynamic stress to dissipate excess heat through the cutaneous circulation was reduced and blood pressure stability was improved.

Blood Volume↗

Relative underestimation of fluid removal during hemodialysis hypotension measured by whole body bioimpedance.

Whole body bioimpedance is considered helpful in monitoring the removal of excess body water by ultrafiltration in hemodialysis patients. In this study, the cumulative, estimated decrease in extracellular volume (V(est)) modeled from whole body bioimpedance data was compared with measured volume (Vmeas) removed by ultrafiltration (UFR = 1.01 +/- 0.31 L/hr) in 12 patients during 36 high efficiency hemodialysis treatments. In the mean, estimated (V(est) = 3.0 +/- 1.4 L) and measured volumes (Vmeas = 3.4 +/- 1.1 L) correlated linearly: V(est) = 1.05 x Vmeas - 0.60, r2 = 0.68. Patients developed hypotension in half the treatments. Except for a larger decrease in systolic blood pressures in hypotensive (34 +/- 24 mmHg) vs. stable (14 +/- 15 mmHg) treatments, patient and treatment characteristics were not different between groups. However, at the end of hemodialysis, the difference V(est) - Vmeas was -0.8 +/- 0.9 L in hypotensive, and only 0.1 +/- 0.4 L in stable patients (p < 0.05). The difference between V(est) and Vmeas can be explained by a predominant removal of excess body water from central body compartments such as the trunk and the central blood volume during hypotension. These compartments are not adequately measured by whole body bioimpedance techniques. However, this information could be helpful in identifying patients with delayed peripheral fluid removal that may occur when either target weight is too low or UFR rates are too high.

Adult↗

Adjunctive antibiotic/anticoagulant lock therapy in the treatment of bacteremia associated with the use of a subcutaneously implanted hemodialysis access device.

To improve vascular access for hemodialysis, a new device (Dialock Hemodialysis Access System, Biolink Corporation, Middleboro, MA) has been developed. Implanted subcutaneously, the device is accessed by percutaneous puncture. Attached to the device are two catheters that are implanted into the superior vena cava or right atrium. Clinical results thus far have been promising. However, use of this device is not free from infectious complications. In the present pilot study, 25 maintenance hemodialysis patients were implanted with 26 Dialock devices. The incidence of bacteremia was 2.9/1,000 catheter days. In 14 episodes of bacteremia in 8 patients the infection was successfully treated with a combination of systemic antibiotic treatment and adjunctive antibiotic/anticoagulant lock therapy. The lock therapy entailed the instillation of both an antibiotic and an anticoagulant into the device. We believe that the antibiotic/anticoagulant lock technique is an effective, adjunctive therapeutic modality in the treatment of infections related to the use of indwelling vascular access devices.

Anti-Bacterial Agents↗

Use of urea kinetics in the nutritional care of the acutely ill patient.

In acutely ill patients nitrogen balance is often assessed clinically from measurements of protein intake and urinary urea nitrogen. We have utilized urea kinetic modeling to measure urea generation rates, protein catabolic rates and nitrogen balance in 19 acutely ill patients with varying degrees of renal dysfunction and have studied the effect of varying caloric intake on protein balance during a period of fixed protein intake. In patients with measured creatinine clearances equal to or greater than 50 ml/min there was a highly significant correlation between nitrogen balance estimates derived from urea kinetic modeling and those obtained from urinary urea nitrogen (R = 0.939; p less than 0.001). When creatinine clearance measurements were between 20 to 50 ml/min the correlation between the two estimates was poorer (R = 0.337; p less than 0.001). In patients whose creatinine clearance was below 20 ml/min the correlation between measurements was worse still (R = 0.229; p less than 0.002). To determine the effects of increasing caloric intake on protein catabolic rate seven acutely ill patients were studied. When caloric intake was increased from 27.8 to 34.2 kcal/kg/day while on a fixed protein intake of 1.27 g/kg/day there was a significant fall in protein catabolic rate from 1.39 to 0.99 g/kg/day (p less than 0.002). As urea kinetic modeling takes into account changes in blood urea nitrogen, extrarenal losses of urea and the urinary urea pool, it is the preferred method for measuring protein balance in acutely ill patients particularly those with poor renal function. Serial monitoring of protein catabolic rates permits easy continuous assessment of the effect of increasing caloric intake on protein sparing during parenteral hyperalimentation.

Acute Disease↗

Income and survival in chronic dialysis patients.

The relationship between income and survival rates for chronic dialysis patients in Michigan was examined. To evaluate the relative risk (RR) of dying, by income, a Cox survival regression model was used to adjust for age, race (black versus white), gender, dialytic treatment modality, year of first end-stage renal disease (ESRD) therapy, and primary cause of ESRD. The average household income reported from census data for the ZIP Code of residence for each patient was analyzed as a socioeconomic indicator. Treatment modality on day 120 of ESRD was classified as either center hemodialysis (HD) or CAPD. All new patients, aged 20-59 and registered at the Michigan Kidney Registry between 1/1/80 and 12/31/87 were included in the study. Patients were followed from day 180 of ESRD until death, censoring at transplant, or 12/31/87. The adjusted relative risk of dying decreased for black patients by 3.3% per $1,000 increase in income (p less than 0.01), while the trend by income for white patients was negligible (p greater than 0.10). The difference in trends for the two groups was statistically significant (p less than 0.01). This is a surprising result, since white patients have higher death rates, overall, than do black patients, particularly among subgroups with diabetes and hypertension whose RR was 1.77 and 1.82, respectively. Poor socioeconomic status of the area of residence has a strongly negative effect on survival for black patients, but not for white patients. The reasons for the relationship of death rates with income, especially for black patients, need to be examined in greater detail.

Adult↗

The effect of cooled dialysate on thermal energy balance in hemodialysis patients.

The authors have monitored extracorporeal thermal energy balance using continuous in-line arterial and venous temperature and blood flow measurements. Use of dialysate at 37 degrees C resulted in a mean heat energy gain of 83 +/- 61 cal/min, whereas dialysate at 34 degrees C produced a loss of 463 +/- 121 cal/min. Monitoring extracorporeal thermal energy balance during cooled-dialysate hemodialysis will facilitate the use of feedback loops for dialysate temperature control in order to maximize hemodynamic stability while reducing discomfort. This methodology also may be helpful in assessing the metabolic effects of protein intake, high flux dialysis, membrane biocompatibility, and adequacy of dialysis in relation to thermal energy balance.

Adult↗

In vivo verification of an automatic noninvasive system for real time Kt evaluation.

It is generally accepted that morbidity and mortality of hemodialysis patients is related to dialysis quantitation. Currently available methods for the quantitation of dialysis require blood sampling or a continuous measurement of changes in urea concentration during treatment. These maneuvers are time consuming and expensive, and are generally performed, at most, once per month. The authors introduce an on-line, automated method for measurement of dialyzer electrolyte clearance comparable to urea clearance by using dialysate conductivity sensors placed pre and post dialyzer, and measuring conductivity at three different pre dialyzer levels. Conditions that reduce clearance, such as recirculation or fiber clotting, are automatically taken into account so that the method measures effective clearance rather than dialyzer clearance. In vitro and in vivo studies validate the method. Results are immediately available and can be used to address problems such as improper needle placement and access recirculation. In addition, repetitive electrolyte clearance data can serve to enhance quality assurance programs with respect to verifying the function of reused or new dialyzers. Appropriate algorithms can be used to calculate delivered Kt/V.

Blood Urea Nitrogen↗