Search PubMed⌕ Search

Biomedical subjects

N Vakil

Publications and source records attributed to N Vakil.

At least 109 records · Page 6Linked to original sources

A prospective, randomized, blinded trial of cytological yield with disposable cytology brushes in upper gastrointestinal tract lesions.

Brush cytology is an important technique in the diagnosis of upper gastrointestinal tract lesions. Optimum cytological yields depend on cellularity (a measure of the amount of epithelial cellular material) and preservation (a measure of artifact induced by desiccation). We sought to determine the cytological yield of four disposable cytology brushes. Seventy-eight patients were studied, with a total of 80 disposable cytology brushes from four different manufacturers (Wilson-Cook, Microvasive, Mill-Rose, and Hobbs). Cellularity and preservation were assessed in a blinded fashion by experienced cytotechnologists. There was no significant difference in cellularity between the different non-disposable brushes. However, the Wilson Cook disposable cytology brush was significantly superior to the other disposable cytology brushes (P < 0.05) with regard to preservation. Its unique design features (longer head and more acutely angled bristles) may account for the better results.

Cytological Techniques↗

Abnormal vitamin B12 metabolism in human immunodeficiency virus infection. Association with neurological dysfunction.

An increased prevalence of vitamin B12 deficiency has been reported in patients infected by the human immunodeficiency virus (HIV). We report an unexpectedly high prevalence (20%) of such abnormal vitamin B12 metabolism in a population of HIV-infected patients referred for neurological evaluation. This abnormality was associated with both peripheral neuropathy and myelopathy. A majority of those treated with cyanocobalamin had a therapeutic response. Selected neuropathological results suggest a relationship between vitamin B12 deficiency and vacuolar myelopathy. Vitamin B12 deficiency may be a frequent and treatable cause of neurological dysfunction in patients with HIV infection.

HIV Infections↗

Gas in gallstones: quantitative determinations and possible effects on fragmentation by shock waves.

The presence of gas in a gallstone can profoundly affect the ability of shock waves to fragment the stone by various mechanisms. In the present study, the aim was to determine the gas content of gallstones and determine if increasing the gas content of the stone affected the outcome of lithotripsy. Thirty human gallstones, transferred directly from gallbladder bile into sterile saline, were studied. The initial gas content of all stones was determined by differential weighing under saline before and after degassing. Eighteen gallstones were pairs; each pair was from a single patient and of similar size and composition. One gallstone of each of the pairs was exposed to air and the other was kept under saline. Then each of the paired gallstones was subjected to 1000 pulses at power level 3 (highest) in a Diasonics Therasonic lithotripter (Diasonics, Milpitas, CA). The volume of gas present at the beginning of the experiment in all groups of stones was 2.4 +/- 2.1 mm3, and 27% of all gallstones tested contained measurable amounts of gas initially. There was no significant difference in the volume of gas present in the paired stones at the beginning of the experiment (group A, 1 +/- 0.4 mm3; group B, 2 +/- 1 mm3). After group A stones were exposed to air, the gas content was significantly higher (36 +/- 18 mm3) than in the paired group B stones stored under saline (3 +/- 2 mm3; P less than 0.05). Stones exposed to air fragmented more easily than stones stored under saline. The mean number of pulses required to cause initial fragmentation was significantly lower in the group of stones exposed to air (22 +/- 7) compared with those stored under saline (610 +/- 139; P less than 0.05). The fragments were smaller and more numerous in the group of stones exposed to air than in those stored under saline. It is concluded that gas is present in some gallstones and that the efficacy of lithotripsy increases with increasing stone gas content. Our data suggest that alterations in the physical characteristics of gallstones can have profound effects on the outcome of lithotripsy.

Analysis of Variance↗

The appreciation of colour in endoscopy.

The perception of colour at endoscopy has been taken for granted since the discovery of the fibreoptic bundle and the advent of fibreoptic endoscopy. Fibreoptic and lens assemblies can distort the impression of colour by selectively absorbing some wavelengths of light. In the case of electronic endoscopes, the principal sensor is the charge-coupled device (CCD), a small microelectronic device that converts an image into a sequence of electronic signals which, after appropriate processing, are transformed into an image on the monitor screen. The image is therefore visualized as a mosaic of small images, one from each sensing element. Colour is synthesized by using sequential illumination using filters or by filters placed over the CCD. Fibre-endoscopes may alter colour by selectively transmitting certain portions of the visible spectrum, while electronic endoscopes are susceptible to errors due to poor calibration of the instrument and manipulation of the colour controls by endoscopists. Colour information provides the endoscopist with clues to the nature of the lesion and also a site for biopsy. In experimental situations, colour information has been used to determine blood flow and classify lesions. Much work needs to be done to define normal and abnormal colour in the gastrointestinal tract and to develop a standard terminology for colour nomenclature in endoscopy.

Color Perception↗

Altered density of glomerular binding sites for atrial natriuretic factor in bile duct-ligated rats with ascites.

The renal response to atrial natriuretic factor is blunted in cirrhosis with ascites. This might be due to alterations of renal receptors for atrial natriuretic factor. Therefore density and affinity of glomerular atrial natriuretic factor binding sites of bile duct-ligated rats with ascites (n = 10) and of sham-operated controls (n = 10) were determined. Glomerular atrial natriuretic factor binding sites were identified to be of the B-("biologically active") and C-("clearance") receptor type. Discrimination and quantitative determination of B and C receptors for atrial natriuretic factor were achieved by displacement experiments with atrial natriuretic factor(99-126) or des(18-22)atrial natriuretic factor(4-23), an analogue binding to C receptors only. Density of total glomerular atrial natriuretic factor binding sites was significantly increased in bile duct-ligated rats (3,518 +/- 864 vs. 1,648 +/- 358 fmol/mg protein; p less than 0.05). This was due to a significant increase of C-receptor density (3,460 +/- 866 vs. 1,486 +/- 363 fmol/mg protein; p less than 0.05), whereas density of B receptors was not significantly different in bile duct-ligated rats (58 +/- 11 vs. 162 +/- 63 fmol/mg protein). Affinity of atrial natriuretic factor to its glomerular binding sites did not differ significantly between both groups. These data suggest that an altered glomerular atrial natriuretic factor receptor density could be involved in the renal resistance to atrial natriuretic factor in cirrhosis with ascites.

Animals↗

Atrial natriuretic factor and cyclic guanosine monophosphate: ion transport in rat colon in vitro and in vivo.

The role of atrial natriuretic factor receptors in the colon is uncertain. Accordingly, the effects of atrial natriuretic factor in vivo and in vitro were studied. In vivo perfusion of the colon in Sprague-Dawley rats was used to measure Na+, K+, Cl-, and water transport, while atrial natriuretic factor was infused into the jugular vein at 0.5 or 1.0 micrograms.kg-1.min-1. In vitro experiments in Ussing chambers measured short-circuit current and ion fluxes before and after atrial natriuretic factor administration. Because cyclic guanosine monophosphate is thought to be a second messenger for atrial natriuretic factor, short-circuit current was also determined before and after exposure to 8-Br-cyclic guanosine monophosphate. Plasma atrial natriuretic factor (atriopeptin III) levels were determined by radioimmunoassay. The in vivo transport of water, sodium, and chloride and the secretion of potassium were not altered by atrial natriuretic factor infusion. In vitro studies showed no change in Na+ or Cl- transport or change in short-circuit current. Plasma atrial natriuretic factor concentrations increased from 139 +/- 55 pg/mL to 1385 +/- 396 pg/mL during infusion, and urine output increased from 12.6 +/- 0.5 microL/min to 37.4 +/- 2.9 microL/min (P less than 0.05). In contrast, 8-Br-cyclic guanosine monophosphate in vitro caused a significant (P = 0.0004) increase in short-circuit current from 1.2 +/- 0.2 to 2.9 +/- 0.3 microEq.cm-2.h-1.

Animals↗

The effects of synthetic human secretin on calcium carbonate solubility in human bile.

This study sought to determine the effects of synthetic human secretin on ionized calcium and carbonate concentrations in human hepatic bile. Five patients with a nasobiliary drain in the right hepatic duct were studied. Three basal samples of bile were collected, each over a 15-minute period. Synthetic human secretin was then infused IV at 0.05 micrograms.kg-1.h-1 for 45 minutes followed by 0.5 micrograms.kg-1.h-1 for 45 minutes. Bile was sampled over 15-minute periods. To document return to baseline conditions, two further samples of bile were obtained over 15-minute periods 2 hours after the infusion was terminated. Bile acid concentration was determined by an enzymatic method; pH and PCO2 were measured with an automated analyzer. Total calcium was determined by inductively coupled plasma emission spectrometry and ionized calcium by an ion-specific electrode. Bicarbonate and carbonate concentrations were calculated using Henry's law and the Henderson-Hasselbalch equation. The fraction of bile sampled by the catheter was determined by Indocyanin Green recovery at the end of the experiment. Secretin caused an increase in bile flow and bicarbonate output. Bicarbonate concentrations increased from 26 +/- 3 mmol/L to 41 +/- 3 mmol/L (P less than 0.05), and chloride concentrations decreased. Mean bile acid concentrations declined significantly from 14.6 +/- 2 mmol/L to 4.7 +/- 1 mmol/L (P less than 0.05). Ionized calcium concentrations decreased from 0.7 +/- 0.005 mmol/L to 0.5 +/- 0.02 mmol/L (P less than 0.05) while pH increased significantly from 7.44 +/- 0.06 to 7.6 +/- 0.04 (P less than 0.05). Carbonate concentrations increased significantly from 0.15 +/- 0.02 mmol/L to 0.26 +/- 0.03 mmol/L, and the ion product for calcium carbonate increased significantly from 0.099 +/- 0.002 (mmol/L)2 to 0.135 +/- 0.015 (mmol/L)2 (P less than 0.05). Synthetic human secretin augments the ion product of calcium and carbonate in human hepatic bile, increasing the tendency for calcium carbonate precipitation.

Analysis of Variance↗

Perspectives in "electronic endoscopy". Past, present and future of fibers and CCDs in medical endoscopes.

Electronic endoscopy has undergone considerable evolution in recent years. Early instruments had poorer resolution than fiberscopes, and distorted colors significantly. The second generation of electronic endoscopes has been considerably improved, and electronic endoscopy is expected to play a major role in endoscopy in the next decade, with its enhanced teaching abilities, permanent image storage, reproduction and retrieval. An important new development has been the development of a high-resolution colonoscope & gastroscope. Electronic endoscopes are now able to produce better resolution than fiberscopes, and the future should bring further improvements in resolution with electronic instruments. A number of problems still remain to be solved with electronic endoscopy. Irregular reflection from secretions, food and blood at short focus (less than 1 cm) results in a loss of resolution, which makes electronic endoscopy particularly difficult when bleeding is brisk. Electronic endoscopes synthesize color from a strobed signal of red, blue and green in a processor. Color is dependent on brightness, and at close focus, excessive brightness in the center of the field results in erratic color reproduction. Images acquired at electronic endoscopy may be digitized for storage and processing in a computer--which, however, is not a straightforward task at the present time. Image processing in electronic endoscopy is still in its early stages, but we anticipate that new developments in early diagnosis, classification and measurement of lesions will take place. Digitized images can also be transmitted via telephone lines, and it will soon be possible to instantaneously send images across the world.

Color↗

Gentamicin nephrotoxicity in extrahepatic cholestasis: modulation by dietary calcium.

The present study was designed to test the hypothesis that the presence of a specific hepatobiliary disease, namely common bile duct obstruction, in the absence of other risk factors will exacerbate gentamicin nephrotoxicity. Furthermore, since bile duct ligation decreases urinary calcium excretion, we studied the role of calcium supplementation in the prevention of gentamicin nephrotoxicity in this model. Male Sprague-Dawley rats were allocated to sham groups and common bile duct ligation groups. Gentamicin at 40 and 100 mg per kg per day for 5 days induced a more severe azotemia in common bile duct ligation animals than in sham controls. Furthermore, higher levels of renal gentamicin were found in common bile duct ligation rats than in sham rats early in the course of therapy, at its termination and during the recovery period. Pretreatment of common bile duct ligation animals with dietary calcium supplementation significantly attenuated gentamicin nephrotoxicity and the increased renal gentamicin accumulation, whereas initiation of calcium supplementation concurrent with gentamicin administration had no salutary effect. We conclude that experimental extrahepatic cholestasis in the rat, in the absence of any other factor, potentiates gentamicin nephrotoxicity. The effect is prevented by pretreatment with dietary calcium supplementation but is not modified by concurrent administration of a high-calcium diet.

Animals↗

The effects of intraduodenal bile acid administration on biliary secretion of ionized calcium and carbonate in man.

The importance of calcium in gallstone formation is increasingly recognized. Calcium carbonate is an important constituent of gallbladder stones and may be present in the nidus of cholesterol stones. Secondary deposition of calcium carbonate on the surface of cholesterol gallstones is an important reason for failure of oral bile acid dissolution therapy. We sought to determine the effects of bile acids on the crystallization conditions of calcium carbonate in bile. We studied 18 patients with choledocholithiasis with a percutaneous or endoscopically placed catheter high in the biliary tree. Samples of bile in the basal state and following replacement of the bile acid pool with cholic acid, chenodeoxycholic acid and ursodeoxycholic acid were analyzed for total calcium, ionized calcium, bicarbonate and carbonate, and the saturation index for calcium carbonate was calculated. Hepatic bile in the basal state was supersaturated with calcium carbonate. Total calcium concentrations rose linearly with rising bile acid concentrations but ionized calcium was maintained in a relatively narrow range. These data are consistent with an important role for bile acids in binding calcium. Extrapolation of the linear regressions between bile acid concentration and calcium concentrations suggested that in the absence of bile acids, biliary calcium concentrations are in passive equilibrium with plasma. Chenodeoxycholic acid and ursodeoxycholic acid caused a bicarbonate-rich choleresis and significantly augmented the saturation index for calcium carbonate, whereas cholic acid caused no change. In contrast with animal models, the apparent choleretic activity of cholic acid, chenodeoxycholic acid and ursodeoxycholic acid was similar, and no hyper-choleresis was observed with ursodeoxycholic acid. Chenodeoxycholic acid and ursodeoxycholic acid therefore increase the thermodynamic possibility for calcium carbonate precipitation.

Aged↗

Steroid-related osteonecrosis in inflammatory bowel disease.

Osteonecrosis is a serious complication of steroid therapy characterized by death of all the cellular elements of bone. We describe a series of patients with steroid-induced osteonecrosis in inflammatory bowel disease. Seven of 161 patients (4.3%) treated with corticosteroids for inflammatory bowel disease over a 10-yr period developed osteonecrosis. The median age at the onset of inflammatory bowel disease was 20 yr and for osteonecrosis the median age was 28 yr. Patients had received steroids for a mean duration of 42 wk with a mean daily dose of 26 mg/day and a mean cumulative lifetime prednisone dose of 7 g. Osteonecrosis occurred within 6 mo of the last administration of steroid in all patients. It presented with joint pain in the hip or knee and was frequently mistaken for the arthralgia of steroid withdrawal or the arthropathy of inflammatory bowel disease. Multiple joints were involved in 6 of the 7 patients. Surgery for the joint disease was required in 4 of the 7 patients. The median duration of follow-up was 2 yr. Five of the 7 patients continued to have significant joint pain and disability that limited their activity. We conclude that inflammatory bowel disease predisposes to steroid-induced osteonecrosis. The age of patients is younger, and the dose and duration are considerably lower than that reported for steroid-induced osteonecrosis in other disease states. Bone scans or magnetic resonance imaging should be performed in patients with joint pain who are receiving or have recently received corticosteroid therapy. Early detection and treatment may prevent the crippling long-term complications of this disease.

Adult↗

Adequacy of "hot biopsy" for the treatment of diminutive polyps: a prospective randomized trial.

Patients with diminutive polyps in the rectum or sigmoid colon were randomized to "hot biopsy" treatment for either 1) electrocautery for 2 s (fixed duration cautery) or 2) cautery until visible necrosis of the polyp base was evident (variable duration cautery). Sigmoidoscopy was performed 4 wk after treatment to determine the adequacy of polyp eradication. In the fixed duration cautery group, 11 of 21 polyps (52%) were eradicated, compared with 12 of 14 polyps (86%) in the variable duration cautery group (p = 0.04). When analyzed according to whether or not visible necrosis was achieved (some of the polyps in the fixed duration cautery group showed necrosis with 2 s cautery), 19 of 23 polyps (83%) were eradicated when necrosis was evident, compared to 5 of 12 (42%) without necrosis (p = 0.004). We conclude that hot biopsy treatment for diminutive polyps is significantly more effective when visible necrosis is achieved during cautery. Furthermore, even with visible necrosis, there is a 17% failure rate of polyp eradication.

Adenoma↗

Optical performance of electronic imaging systems for the colon.

Electronic (video) endoscopes are a significant new development in gastroenterology, offering the potential of enhanced teaching and permanent storage of pictorial data. The primary concern of gastroenterologists is the resolution and color performance of these instruments, as these parameters have important bearings on the ability to discern pathological changes in mucosa. We sought to determine the resolution and color capabilities of electronic colonoscopes and compare them with a conventional fiber colonoscope. Resolution was determined using a standard test chart at various distances and the number of picture elements (a measure of resolution) was calculated. The mean number of picture elements was Fujinon (219), Fiber (172), Pentax (169), Toshiba (142), Olympus (140), and Welch Allyn (133). In close focus examination (target distances less than 1 cm), the Fujinon and Toshiba endoscopes had significantly higher resolution than the other instruments. Color was measured quantitatively using a standard color chart and a color analyzer. Color polygons were plotted for each endoscope on a reference chromaticity diagram. All systems had an acceptable overall performance but color was undersaturated with some systems. The optical performance of electronic endoscopes has improved considerably since the inception of electronic endoscopy.

Colonoscopes↗

Complications of endoscopic gastrostomy: pneumoperitoneum and volvulus of the colon.

Pneumoperitoneum caused by percutaneous gastrostomy usually follows a benign clinical course, but led to progressive volvulus of the ileocolic segment in the patient described here. This article explains relationships between pneumoperitoneum after surgical or endoscopic procedures and volvulus involving the intraperitoneally mobile intestinal loops.

Aged↗

Pasteurella multocida septicemia and peritonitis in a patient with cirrhosis: case report and review of the literature.

A case of Pasteurella multocida septicemia and peritonitis in a patient with cirrhosis is reported and the literature reviewed. Patients with cirrhosis and exposure to domestic animals are at risk for this infection. Initial empiric therapy of spontaneous bacterial peritonitis in such patients should include a penicillin to which this organism is usually susceptible.

Adult↗