Search PubMed⌕ Search

Biomedical subjects

N Soehendra

Publications and source records attributed to N Soehendra.

At least 55 records · Page 3Linked to original sources

Endoscopic ultrasound for differential diagnosis of focal pancreatic lesions, confirmed by surgery.

BACKGROUND: Endoscopic ultrasound is increasingly used for evaluation of pancreatic cancer. The potential of sonographic morphology to differentiate histology type and biological behaviour of pancreatic lesions is doubtful. METHODS: We prospectively studied 115 patients with focal pancreatic lesions on endoscopic ultrasound. Morphology was assessed using Olympus UM3/20/200 echoendoscopes. Histologic confirmation of diagnosis was obtained in all patients. RESULTS: Endoscopic ultrasound correctly diagnosed 18/34 benign and 77/81 malignant lesions. Sensitivity, specificity, accuracy, PPV and NPV for diagnosing malignancy were 95%, 53%, 83%, 83% and 82%, respectively. Endosonographic diagnosis of the lesions (% correct) were: pancreatic cancer, 84 (63.3%); chronic pancreatitis, 14 (71.4%); ampullary cancer, 9 (77.8%); cystadenoma, 5 (80%); ampullary adenoma, 2 (50%); acute pancreatitis, 1 (0). In 13 patients of chronic pancreatitis, diagnosed as cancer, diagnosis was based on absence of sonographic features of chronic pancreatitis (7) or suspected involvement of adjacent structures (6). In 3 patients malignancy was missed owing to features of chronic pancreatitis. Non-suspected neuroendocrine tumours were misjudged in all 10 cases using morphologic criteria as pancreatic cancer (8), cystadenoma and chronic pancreatitis. Accuracy for prediction of metastatic lymph nodes and an advanced pancreatic cancer stage (TxN1 or T3Nx) was 61% and 75%, respectively. On retrospective analysis, a lesion >2 cm, vessel ingrowth, absence of cystic spaces and absence of diffuse pancreatitis were associated with pancreatic cancer. CONCLUSIONS: While overall sensitivity was high, specificity of endoscopic ultrasound for diagnosis of malignancy was low, especially in presence of chronic pancreatitis. In addition, endosonography had only a limited potential to predict the histological type of lesions.

Adult↗

Mediastinal lymphadenopathy in patients with or without previous malignancy: EUS-FNA-based differential cytodiagnosis in 153 patients.

OBJECTIVE: Mediastinal lymphadenopathy (ML) is a cause for concern, especially in patients with previous malignancy. The investigation of choice is thoracic CT with a variable sensitivity and specificity requiring tissue diagnosis. We used endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) for cytodiagnosis of ML in patients with and without previous malignancy. The cause, distribution of lesions, and incidence of second cancers were investigated. METHODS: Linear echoendoscopes and 22-gauge needles for cytology were used for EUS-FNA. A cytological diagnosis of malignancy was accepted, and histology or consistent follow-up of at least 9 months confirmed benign results. RESULTS: One hundred fifty-three patients underwent EUS-FNA between November 1997 and November 1999 (mean age, 60 yr; range, 13-82 yr; 105 men). Cytology was adequate in 150 patients. Final diagnosis was malignancy in 84 and benign in 66 patients (sensitivity, specificity, and diagnostic accuracy: 92%, 100%, 95%, respectively). In 101 patients without previous cancer cytology identified 48 malignant (lung, 41; extrathoracic, 7) and 51 benign lesions (inflammation, 35; various, 9; sarcoidosis, 7) (sensitivity, specificity, accuracy: 88%, 100%, 94%). Fifty-two patients had prior malignancy, mostly in extrathoracic sites. Cytology revealed recurrences in 21 patients, second cancer in 9 and benign lesions in 21 patients (inflammatory, 11; sarcoidosis, 8; tuberculosis, 1; abscess, 1) (sensitivity, specificity, accuracy: 97%, 100%, 98%). CONCLUSIONS: In patients without previous cancer malignant ML originates from the lung >80%. In those with previous malignancy recurrence of extrathoracic sites is the major cause. Benign lesions and treatable second cancers occur in a significant frequency, emphasizing the need for tissue diagnosis. EUS-FNA is a safe and minimally invasive alternative for cytodiagnosis in the mediastinum.

Adolescent↗

Endosonography-guided, fine-needle aspiration cytology extending the indication for organ-preserving pancreatic surgery.

OBJECTIVE: Organ preserving pancreatic resections are considered whenever malignant disease is ruled out. In tumors of low malignant potential such as cystadenomas and neuroendocrine tumors, the diagnosis is rarely established preoperatively. We studied the feasibility of cytodiagnosis using endosonography-guided fine-needle aspiration in determining the operative approach. METHODS: A total of 78 patients (16 female, 62 male; mean age 61.4 yr, range 31-82 yr) with focal pancreatic lesions underwent EUS-FNA. Final diagnosis was confirmed by histology, cytology, or clinical follow up (>9 months). Patients with tumors of low malignant potential were managed by customized pancreatic resections. RESULTS: Final diagnosis was malignant tumors in 36 patients, tumors of low malignant potential in nine (six, neuroendocrine, two, borderline mucinous cystadenomas, one, borderline adenocarcinoma), and benign in 31 (two inadequate smears). No complications occurred. With six false-negative and no false-positive results, the accuracy, sensitivity, specificity, and positive and negative predictive values were 92%, 84%, 100%, 100%, and 86%, respectively. Five patients with low malignant tumors underwent duodenum-preserving pancreatic head resection, three mid segment resection, and one pylorus-preserving pancreatoduodenectomy. CONCLUSIONS: EUS-FNA is useful in the preoperative cytodiagnosis of pancreatic tumors of low malignant potential. It extends the indication for organ-preserving pancreatic resections and avoids the unnecessary sacrifice of adjacent organs.

Adenocarcinoma↗

Prospective evaluation of morphology, function, and quality of life after extracorporeal shockwave lithotripsy and endoscopic treatment of chronic calcific pancreatitis.

OBJECTIVE: Therapeutic endoscopy may be effective in selected patients with chronic calcific pancreatitis (CCP). We prospectively evaluated the early outcome of extracorporeal shockwave lithotripsy (ESWL) in combination with interventional endoscopy, using broad inclusion criteria. METHODS: A total of 48 consecutive patients (35 male, 13 female) were recruited for ESWL and endoscopic therapy of symptomatic CCP. Symptoms, quality of life, pancreatic morphology and function were assessed before and after. RESULTS: Multiple stones (n = 43), strictures (n = 34), and pancreas divisum (n = 11) were found. A median of 13 ESWL sessions (range 2-74) with a median of 22,100 shockwaves (1,700-150,900) were required. Endoscopic pancreatic sphincterotomy (n = 48), stricture dilation (n = 12), and/or stenting (n = 27) were performed. After therapy, drainage of the pancreatic duct system was achieved in 36, complete stone clearance in 21 patients. Follow-up (n = 38) at 7 months (range 5-9) showed a significant decrease in pancreatic duct diameter (p < 0.001) and pain score (p < 0.0001) whereas complete pain relief was observed in 45% of cases. Several quality of life scores improved significantly. Weight gain occurred in 68% of patients. Normalization of fasting blood glucose and HbA1c levels were observed in four patients, without modifying their treatment. Improvement in pain score correlated with weight gain and decrease in pancreatic duct diameter. Nonalcoholic etiology was associated with a better chance for improvement in pain score and decrease in pancreatic duct diameter. The presence of strictures did not deteriorate the clinical outcome. CONCLUSIONS: Besides pain relief, ESWL in combination with interventional endoscopy resulted in pancreatic ductal decompression, weight gain, and improvement in quality of life in a considerable number of patients with advanced CCP.

Calculi↗

Boerhaave-mimicking esophageal perforation with subsequent esophagobronchial fistula formation as the primary manifestation of Crohn's disease.

BACKGROUND: Spontaneous ruptures of the esophagus are rare, but may lead to deleterious courses, even if diagnosed early. CASE REPORT: We report a case of Boerhaave's syndrome-mimicking esophageal perforation due to a stricture of the distal esophagus as the primary manifestation of Crohn's disease. Diagnosis was delayed resulting in a complicated clinical course. The presented patient is the first case in the literature with esophageal perforation related to a previously undiagnosed Crohn's disease that lead to stenosis of the distal esophagus before becoming clinically apparent. CONCLUSION: Difficulties in differential diagnosis, problems related to initial misdiagnosis and consecutive mismanagment of spontaneous esophageal perforation, and treatment options including nonsurgical approaches are discussed.

Aged↗

Role of transesophageal endosonography-guided fine-needle aspiration in the diagnosis of lung cancer.

STUDY OBJECTIVE: Bronchoscopic methods fail to diagnose lung cancer in up to 30% of patients. We studied the role of transesophageal endosonography (EUS)-guided fine-needle aspiration (FNA; EUS-FNA) in such patients. DESIGN: Prospective study. The final diagnosis was confirmed by cytology, histology, or clinical follow-up. SETTING: University hospital. PATIENTS: Thirty-five patients (30 male and 5 female; mean age, 60.9 years; range, 34 to 88 years) with suspected lung cancer in whom bronchoscopic methods failed. Patients with a known diagnosis, recurrence of lung cancer, or mediastinal metastasis from an extrathoracic primary were excluded. INTERVENTIONS: EUS and guided FNA of mediastinal lymph nodes. RESULTS: The procedure was uneventful, and material was adequate in all. The final diagnosis by EUS-FNA was malignancy in 25 patients (11 adenocarcinoma, 10 small cell, 3 squamous cell, and 1 lymphoma) and benign disease in 9 patients (5 inflammatory, 2 sarcoidosis, and 2 anthracosis). Another patient with a benign result had signet-ring cell carcinoma diagnosed on pleural fluid cytology (probably false-negative in EUS-FNA). The sensitivity, specificity, accuracy, and positive and negative predictive values were 96, 100, 97, 100, and 90%, respectively. There were no complications. Reviewing the EUS morphology, the nodes were predominantly located in levels 7 and 8 of American Thoracic Society mediastinal lymph node mapping (subcarinal and paraesophageal region). In seven patients, the punctured nodes were < 1 cm (four malignant and three benign), which are difficult to sample by other methods. The malignant nodes had a hypoechoic, homogenous echotexture. CONCLUSIONS: EUS-FNA is a safe, reliable, and accurate method to establish the diagnosis of suspected lung cancer when bronchoscopic methods fail, especially in the presence of small nodes.

Adult↗

Diagnosing sarcoidosis using endosonography-guided fine-needle aspiration.

STUDY OBJECTIVES: The ability to diagnose sarcoidosis cytologically has been reported previously, but the method is rarely used. Endoscopic ultrasonography (EUS) is a sensitive technique for detecting mediastinal lymph nodes, which in addition provides an opportunity to carry out guided fine-needle aspiration (FNA) cytology. We report herein on the use of EUS-FNA in the diagnosis of sarcoidosis. PATIENTS AND METHODS: Nineteen patients with suspected sarcoidosis were investigated using EUS-FNA with a linear echoendoscope and a 22-gauge Hancke-Vilman needle. MEASUREMENTS AND RESULTS: In all 19 patients, EUS revealed enlarged mediastinal lymph nodes (mean size, 2.4 cm), located subcarinally (n = 15), in the aortopulmonary window (n = 12), or in the lower posterior mediastinum (n = 5). The nodes had an isoechoic or hypoechoic appearance, with atypical vessels in five cases. The amount of aspirate obtained using EUS-FNA was adequate in all patients, and contained blood in excess of normal in some, indicating a high degree of vascularity. Cytology demonstrated epithelioid cell granuloma formation, suggesting sarcoidosis. Mycobacterial cultures were negative in all of the patients except one, in whom the final diagnosis was tuberculosis. The specificity and sensitivity of EUS-FNA in the diagnosis of sarcoidosis were 94% and 100%, respectively. CONCLUSIONS: EUS of mediastinal lymph nodes in sarcoidosis reveals certain characteristic features. However, it is not capable of differentiating the lesions from tuberculosis or malignancy. EUS-FNA is a safe and sensitive method of aspirating material for cytology and mycobacterial cultures. We believe it will provide a useful alternative in the diagnosis of sarcoidosis.

Adult↗

[Endoscopic argon plasma coagulation of Barrett mucosa].

BACKGROUND: Up to 10% of patients with Barrett's esophagus develop adenocarcinoma of the distal esophagus. Endoscopic surveillance is recommended. We studied the potential of Argon plasma coagulation (APC) for eradication of Barrett's esophagus. METHODS: Indication for APC was the histologic evidence of columnar epithelium with a length of > or = 2 cm, located proximal of the cardia and with the presence of goblet cells. Endoscopic therapy was performed using an Argonbeamer (Beamer 2, Erbe Company, Tübingen, Germany) under i.v. sedation and repeated in intervals of 2-3 weeks with the aim of complete eradication of Barrett's epithelium. One month after macroscopic Barrett eradication, superficial and deep biopsies were obtained every 2 cm in 4 quadrant technique to confirm the endoscopic aspect of complete eradication. RESULTS: We report our results (follow-up median: 12 mths., 3-25) in the first 12 patients (8m/4f, median age 57 yrs., 42-69) in which treatment was completed. In one case there was evidence of moderate dysplasia. A mean of 5 (4-11) sessions were required for complete Barrett eradication in 11 patients (median size of Barrett-segment: 4 cm, range 2-11), in one patient partial regression of 50% was observed treatment was discontinued after 17 sessions while only. Deep biopsies showed subepithelial columnar epithelium islands in one case, recurrence of Barrett occurred in 2 cases after 3 and 6 months. Under APC-treatment, 11/12 patients complained about retrosternal pain and odynophagia. No other complications were observed. CONCLUSION: Our preliminary results indicate that APC is safe and effective to eradicate Barrett's epithelium. Follow-up in a larger number of patients is necessary to assess longterm results (Barrett recurrence, decrease in the incidence of the adenocarcinoma), before APC may generally be recommended.

Adenocarcinoma↗

New haemostatic techniques: histoacryl injection, banding/endoloop ligation and haemoclipping.

New endoscopic modalities for the haemostasis of upper gastrointestinal bleeding include cyanoacrylate tissue glue injection for oesophageal and gastric varices, ligation using bands and loops for variceal and non-variceal bleeding, and clips for non-variceal bleeding. These new modalities aim to improve primary and secondary haemostasis rates and the safety of endoscopic treatment. Preliminary experience using these modalities has been encouraging, but prospective randomized trials using adequate patient numbers are still needed to validate their efficacy and safety. The choice of treatment will depend on the clinical context and the anatomy of the bleeding lesion. Cyanoacrylate injection, which achieves rapid haemostasis and obliteration of the treated varix, is ideally suited to acute variceal bleeding and the obliteration of large gastric varices. Bands and loops are used in conjunction with a transparent cap attachment for the elective treatment of oesophageal varices. The clip is most effective when a vessel from a non-variceal bleeding source can be identified.

Enbucrilate↗

Stent retriever for dilation of pancreatic and bile duct strictures. brand@uke.uni-hamburg.de.

BACKGROUND AND STUDY AIMS: Dilation of high grade strictures of pancreatic or biliary ducts using dilating or balloon catheters may fail. We evaluated the efficacy of the 7-Fr Soehendra Stent Retriever used as a dilator. PATIENTS AND METHODS: Following sphincterotomy, the stricture was first negotiated with a 260 cm long 0.032-inch J-type Terumo wire. Dilation was then attempted using a 7-Fr dilating catheter. If the stricture could not be traversed, the 7-Fr Stent Retriever was inserted over the Terumo wire to dilate the stricture. Between May 1996 and January 1997, the Stent Retriever was used for dilation in 32 patients with biliary or pancreatic duct strictures. RESULTS: The indication for therapeutic endoscopic retrograde cholangiopancreatography (ERCP) was symptomatic chronic pancreatitis in 21 patients (twelve men, nine women; mean age 45.7, range 26-70). The mean length (+/-SD) of the pancreatic duct strictures was 20mm+/-10 (range 3-55) with a prestenotic ductal diameter of 9mm+/-2 (range 2-15). Out of 21 patients, nine suffered from pancreaticolithiasis and were treated with extracorporeal shock wave lithotripsy. All but three patients underwent successful stenting in the same session. Another 11 patients (four men, seven women; mean age 67.4, range 47-85) had cholestasis because of benign or malignant bile duct strictures. The mean length of the strictures was 20mm+/-5 (range 3-40), and the mean prestenotic diameter was 10mm+/-5 (range 4-21). Stenting was easily done in all of these patients in the same session. Symptom relief was observed within the first week after stenting in all patients with a biliary or pancreatic stricture. In seven cases, material for cytological examination was obtained from the bile duct, which revealed malignancy in two cases. There was no complication associated with the use of the Stent Retriever. One subcapsular liver perforation was caused by the guide wire and occurred prior to the use of the Retriever. CONCLUSIONS: Tight pancreatic and bile duct strictures can be dilated successfully with the Stent Retriever. The procedure is of low risk. In addition, tissue sampling is possible in some cases.

Cholestasis↗

[Endosonographically controlled fine needle aspiration cytology--indications and results in routine diagnosis].

UNLABELLED: The usefulness and clinical utility of routine EUS-guided fine needle aspiration cytology (FNA) in the diagnosis of lesions adjacent to the upper gastrointestinal tract was prospectively studied. METHODS: EUS/FNA was performed in 122 patients for 125 lesions: Mediastinal lymph nodes (n = 56), pancreatic lesions (n = 45), paragastric masses (n = 12), submucosal tumors (n = 4) and small hepatic lesions (n = 2) were successfully punctured for cytological diagnosis. RESULTS: Adequate material was gained in 119 out of 125 punctures (95%). Overall sensitivity, specifity, positive and negative predictive value were 90%, 98%, 98% and 89%. Results of EUS/FNA in mediastinal lymph nodes were superior (95%, 100%, 100%, 90%) to those in pancreatic lesions (80%, 100%, 100%, 80%). In paragastric masses sensitivity was 100% whereas specifity was only 67%--due to one false-positive result. Out of four submucosal tumors diagnosis was revealed in three. Two liver metastasis were successfully punctured. 35 out of 56 mediastinal nodes showed malignancy. 27 metastases of lung-, three of gastric-, two of renal cancer and three Non-Hodgkins's lymphoma were diagnosed. The cytological results of 45 pancreatic lesions showed cancer in 19 and chronic inflammation in 21, two abscesses and three benign cysts. There were no complications. 37 patients were treated on outpatient's basis. CONCLUSIONS: EUS-guided FNA is an accurate and safe technique to sample cytology from lesions adjacent to the wall of the upper gastrointestinal tract. New indications may be established for the diagnosis of lung cancer or metastases of other spreading out into the mediastinum or the celiac axis.

Adult↗

Advances in therapeutic endoscopic treatment of common bile duct stones.

Advances in cannulation techniques and instruments have helped in difficult bile duct cannulation and thus stone extraction. For small common bile duct (CBD) stones, endoscopic papillary balloon dilatation has been proposed as an alternative to endoscopic papillotomy (EPT). The technique must undergo further evaluation before recommending its routine use. For most patients with bile duct stones, EPT remains the method of choice. Out of 8204 patients treated in three surgical endoscopy centers (Chile, Germany, and India), 86% to 91% of all CBD stones could be extracted subsequently after EPT using a Dormia basket; 4% to 7% required mechanical lithotripsy (ML) before removal and 3% to 10% of the patients needed other sophisticated techniques, such as electrohydraulic lithotripsy (EHL), laser-induced shock-wave lithotripsy (LISL), or extracorporeal shock-wave lithotripsy (ESWL). The local expertise and availability of equipment determines the choice of method used. In general, EHL or LISL is used for impacted CBD stones including stones in Mirizzi syndrome refractory to ML. ESWL is best suited for intrahepatic stones. Permanent stenting can be offered to poor risk patients instead of extensive procedures to clear the bile duct. Using currently available nonsurgical techniques, fewer than 1% of all patients with bile duct stones still require surgical intervention.

Algorithms↗

EUS-guided, fine-needle aspiration biopsy using a new mechanical scanning puncture echoendoscope.

BACKGROUND: A new mechanical sector scanning echoendoscope designed for EUS-guided, fine-needle aspiration biopsy (FNAB) was prospectively evaluated. The technical feasibility, safety, and histocytologic FNAB results are reported. METHODS: Eighty-six patients underwent 106 FNAB procedures. The new echoendoscope has a 2.8 mm accessory channel and an elevator. Target sites: pancreas 58, lymph nodes 43, and miscellaneous lesions 5. Lesions were punctured with a 0.7 mm needle and submitted for cytologic and histologic examination. Definitive diagnosis was by surgery or clinical follow-up. RESULTS: The wide scanning field (250 degrees) enabled easy sonographic orientation for FNAB. Longitudinal needle visibility was "good" in 93% and 71% of transesophageal and transgastric procedures, respectively, but were compromised during most transduodenal procedures. Needle penetration of indurated pancreatic lesions failed in two patients, and in four additional patients pancreatic sampling succeeded only after a second attempt using an automated spring-loaded device. The mean number of passes was three. Ten percent of FNAB specimens were "inadequate"; excluding these, the diagnostic accuracy rate was 97%; sensitivity for malignancy was 88.5% and specificity was 100%. CONCLUSION: EUS-guided FNAB is feasible, safe, and accurate using the new mechanical puncture echoendoscope. Needle visibility needs to be improved, particularly for transduodenal FNAB.

Adult↗

Endoscopic ultrasound-guided, 18-gauge, fine needle aspiration biopsy of the pancreas using a 2.8 mm channel convex array echoendoscope.

BACKGROUND: Previous studies have reported on endoscopic ultrasound-guided, fine needle aspiration biopsy using 22- to 25-gauge needles. We evaluated the histologic and cytologic yield of endoscopic ultrasound-guided, fine needle aspiration biopsy of the pancreas using an 18-gauge, Menghini-type core needle. METHODS: Fine needle aspiration biopsy was performed in conjunction with a prototype 2.8 mm channel convex array echoendoscope. The core specimen was placed in formalin for cell block, and residual material was expelled on slides for cytology. Definitive diagnosis was established by surgery or clinical follow-up. RESULTS: Of 45 patients who underwent fine needle aspiration biopsy, the needle failed to penetrate indurated pancreatic lesions in five. An average of 2.6 passes were performed in the remaining patients. Sufficient material for a histologic and/or cytologic diagnosis was obtained in 40 patients (histologic and cytologic yield of 68% and 75%, respectively). Combining the results of histology and cytology, the sensitivity and specificity for detection of malignancy was 76% and 100%, respectively. Histology confirmed the cytologic findings in 35 patients, providing additional tissue specific information. In three cases histology established a diagnosis of malignancy where cytology was not conclusively malignant. However, in three cases of surgically confirmed malignancy histology failed to detect malignancy, whereas cytology showed suspicious or malignant cells. The sensitivity of histology and cytology alone in detecting malignancy was 53% and 70%, respectively. Mild pancreatitis occurred after pancreatic fine needle aspiration biopsy in one patient. CONCLUSION: Core specimens for histology can be safely obtained using an 18-gauge needle. Histology provides tissue-specific information that complements cytology, but histology is less sensitive than cytology in detecting malignancy.

Adenocarcinoma↗