Sarcoidosis has been observed in association with numerous blood dyscrasias including lymphoma, leukemia, and multiple myeloma. This report describes a patient with sarcoidosis and a refractory anemia whose bone marrow karyotype showed deletion of the long arm of chromosome 5, consistent with a myelodysplastic syndrome. Concurrent sarcoidosis and myelodysplasia may relate to the continued availability of cytokines as a consequence of repeated macrophage, T-cell, and B-cell interactions, with evolution to the 5q- abnormality. This association may merit specific attention in the future approach to the diagnostic evaluation in certain patients with sarcoidosis.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Conflicting data have been reported regarding adjustment of atrioventricular (AV) interval to maximise hemodynamic performance of dual chamber pacemakers. Eleven consecutive patients with complete heart block and dual chamber pacemakers were paced at three AV intervals (150, 200, 250 msec) and free running rates (60-93 bpm, mean 73 +/- 12 bpm) with simultaneous measurements of cardiac output, atrial contribution to left ventricular filling, left ventricular ejection fraction, and peak aortic velocity and acceleration by echo-Doppler techniques to define the optimum AV delay. At all the three AV intervals tested there was no difference in cardiac output (4.7 +/- 0.96, 4.83 +/- 1.12, 4.77 +/- 1.19 litres/min respectively, p = NS), left ventricular ejection fraction (60.2 +/- 10.6%, 61.2 +/- 9.9% and 64 +/- 8.3%, p = NS), atrial contribution to left ventricular filling (0.37 +/- 0.10, 0.38 +/- 0.09, 0.36 +/- 0.16, n = 8, p = NS), peak aortic velocity (104 +/- 8, 105 +/- 12, 104 +/- 13 cm/sec, p = NS) and aortic acceleration (19.68 +/- 4.26, 20.4 +/- 5.58 and 19.0 +/- 4.54 m/sec2, p = NS). Compared to AV delay of 150 msec an increase in cardiac output of 0.5 L/minute was observed in three patients at an AV delay of 200 msec and in one patient at the AV delay of 250 msec. These data suggest that it is difficult to generalize an optimum AV delay in patients with dual chamber pacemakers. With the AV interval in the range of 150-250 msec, only a minority of patients could improve their haemodynamics at rest by adjusting this interval if the baseline cardiac function was normal.
Twelve years experience with pacemaker re-use is reported. Between November 1979 and December 1991, forty two pacemakers were re-used in 42 patients after in-hospital reconditioning. There were 31 males and 11 females in the age range of 29 to 84 years (mean 59 +/- 13 years). In 29 patients, the pulse generator was explanted because of pocket infection and/or impending extrusion, and it was re-implanted at a new site after sterilization. In the remaining 13 patients pacemakers explanted from other patients were implanted because of economic reasons. All patients were regularly followed up in the pacemaker clinic for a mean duration of 34 +/- 35 months (range 6-126 months). There was one infection and one erosion after 12 and 27 months respectively. One of these units was resterilized and implanted without any recurrence of infection or erosion over a follow up of 12 months. There was no adverse reaction or pulse generator failure. Our experience suggests that the use of refurbished pacemakers is a safe and economically viable option.
The long term performance of various pacing leads in use for at least one year is reported from one centre. Between January 1975 and December 1990, 1056 cardiac pacing leads were implanted in 881 patients (mean age 57 +/- 13 years). Eight hundred and three leads were silicone insulated (SI) and 253 leads were polyurethane insulated (PUI). Leads from different manufacturers were used (Medtronic, CPI, Telectronics). The average duration of follow up was 56.6 +/- 77 months (range 12-221 months) for SI and 47.1 +/- 24 months (range 12-99 months) for PUI leads. Overall lead failure occurred more often in the PUI group (n = 46, 18.2%) compared to SI group (n = 93, 11.3%, p < 0.025). Majority of lead failures occurred in the first 36 months after implantation. In particular, Medtronic models 6971, 6972 (urethane) and 6901 (silicone) showed higher rate of complications (25.5%, 26.3% and 44.5% respectively).
Identification of atrial capture during pacing from right atrial appendage is frequently difficult. Electrocardiograms of forty five patients implanted with AAI/DDD pacemakers (thirty unipolar, fifteen bipolar) were analysed to characterize the specific morphology of paced P waves. Compared to sinus P waves, atrial pacing resulted in atrial depolarization of lower amplitude (0.16 +/- 0.05 mv vs 0.11 +/- 0.032 mv, P less than 0.005) but increased duration (0.07 +/- 0.009 sec vs 0.08 +/- 0.017 sec, P less than 0.005). P wave morphology was similar in unipolar and bipolar pacing units. It was positive in lead I (80%), II (71.11%), III (80%) and aVF (75.55%). In lead aVL, paced P waves were usually diphasic with an initial negative deflection (35.55%). Precordial leads showed paced atrial depolarization of small amplitude and did not help in identification of atrial capture. In unipolar pacing P waves were best seen in lead III because of small pacing spike in this lead. Lead II was suitable for identification of paced P waves in bipolar pacing. Thus careful examination of standard ECG leads for paced P waves of low amplitude, prolonged duration and specific morphology can help in confirming atrial capture following pacing stimulus from right atrial appendage.
Long term performance of 163 atrial leads implanted in 158 patients between July 1981 and June 1993 was evaluated. There were 122 DDD and 36 AAI units, with 125 (77%) polyurethane and 38 (23%) silicone leads. One hundred and nine (67%) unipolar and 54 (33%) bipolar leads were used. Patients were followed in the Pacemaker Clinic for 6 to 124 months (mean 50 +/- 39 months). Five patients were lost to follow up. Transient malfunction was observed in 18 cases (sensing 13, pacing 5) within the first 2 weeks. In 13 cases failure to sense subsided spontaneously and in 4 pacing malfunction could be corrected by reprogramming. Lead dislodgement occurred in 4 patients (2.5%), all within the first week. After the 1st month malfunction was uncommon. Between 1 and 12 months undersensing occurred in 4 (2.5%). In 3 cases it could be corrected by reprogramming. In the first year, reoperation was performed in 5 cases for lead related problems (3 dislodgements, 2 insulation failures). Beyond 12 months complications were as follows: failure to sense-8 (5%), failure to pace-3 (2%), insulation break -1 (0.6%). Majority of these problems could be managed by reprogramming. Reoperation was performed in 1 case with insulation break. The pacing mode had to be changed in 5 (3%) patients with dual chamber units who had loss of P wave sensing. During follow-up 98%, 98%, 96%, 95% and 83% of the leads were working satisfactorily at 1,2,3,4 and 9 years respectively. Thus atrial leads have excellent long term performance and an acceptable rate of late malfunction.