Search PubMed⌕ Search

Biomedical subjects

N Pallikarakis

Publications and source records attributed to N Pallikarakis.

At least 37 records · Page 2Linked to original sources

A computer program for estimating the influence of the body bicarbonate pool during CO2 breath tests.

Mathematical representation of physiological systems is a useful means of monitoring various parameters and factors of such systems. The use of compartmental models for the study of physiological systems has led to the introduction of several new techniques for solving problems, concerning the kinetics between the individual sites of these systems. The computer program, presented here, allows the calculation of the influence of a mammillary model, representing the bicarbonate pool, on the expiration rate of the label, administered during a breath test. It consists of two modules, one for performing non-linear least squares regression fitting of discrete measurements from a breath test (model output) and a second one for estimating the corresponding label released into the bicarbonate pool (model input), based on the measurements of expired air. Data, derived from metabolic studies using oral administration of naturally labelled 13C-glucose in man, under various metabolic conditions, was used as an input to this program.

Bicarbonates↗

Fructose utilization during exercise in men: rapid conversion of ingested fructose to circulating glucose.

The aim of the present study was to compare the metabolic fate of repeated doses of fructose or glucose ingested every 30 min during long-duration moderate-intensity exercise in men. Healthy volunteers exercised for 3 h on a treadmill at 45% of their maximal oxygen consumption rate. "Naturally labeled" [13C]glucose or [13C]fructose was given orally at 25-g doses every 30 min (total feeding: 150 g; n = 6 in each group). Substrate utilization was evaluated by indirect calorimetry, and exogenous sugar oxidation was measured by isotope ratio mass spectrometry on expired CO2. Results were corrected for baseline drift in 13C/12C ratio in expired air due to exercise alone. Fructose conversion to plasma glucose was measured combining gas chromatography and isotope ratio mass spectrometry. Most of the ingested glucose was oxidized: 81 +/- 4 vs. 57 +/- 2 g/3 h for fructose (2P < 0.005). Exogenous glucose covered 20.8 +/- 1.4% of the total energy need (+/- 6.7 MJ) compared with 14.0 +/- 0.6% for fructose (2P < 0.005). The contribution of total carbohydrates was significantly higher and that of lipids significantly lower with glucose than with fructose. The blood glucose response was similar in both protocols. From 90 to 180 min, 55-60% of circulating glucose was derived from ingested fructose. In conclusion, when ingested repeatedly during moderate-intensity prolonged exercise, fructose is metabolically less available than glucose, despite a high rate of conversion to circulating glucose.

Adult↗

Influence of the bicarbonate pool and on the occurrence of 13CO2 in exhaled air.

In 13CO2 breath tests, based on 13C:12C ratio measurements, the appearance of 13C in exhaled CO2 was monitored after the administration of a 13C-labelled compound. Independently of the substrate used, the existence of a bicarbonate pool into which the CO2 produced enters before being exhaled, imposes a delay on the appearance of changes in the 13C:12C ratio. To estimate the nature and magnitude of this delay, we applied a two-compartment model to describe the kinetics of the body bicarbonate pool and we evaluated the 13C:12C ratio of CO2 entering that pool from the measured 13C:12C ratio in the exhaled CO2 after an oral intake of "naturally labelled" 13C-glucose. Our results demonstrated that discrepancies between total and exogenous glucose oxidation in relation to the peak occurrence time, as well as the absolute quantities, could be adequately explained by the interference of the bicarbonate stores.

Bicarbonates↗

Remarkable metabolic availability of oral glucose during long-duration exercise in humans.

It was reported previously that glucose ingestion prior to or at the beginning of muscular exercise was a readily available metabolic substrate. The aim of this study was to see what percentage of carbohydrate utilization can be covered by glucose ingested regularly during exercise. Male healthy volunteers exercised for 285 min at approximately 45% of their individual maximal O2 uptake on a 10% uphill treadmill. After 15 min adaptation to exercise they received either 200 g (group G 200) or 400 g (group G 400) glucose (0.25 g X ml H2O-1) orally in eight equal doses repeated every 30 min (G 200 = 8 X 25 g, n = 4; G 400 = 8 X 50 g, n = 4). Indirect calorimetry was used to evaluate carbohydrate and lipid oxidation. Naturally labeled [13C]glucose was used to follow the oxidation of the exogenous glucose. Total carbohydrate oxidation was 341 +/- 22 and 332 +/- 32 g, lipid oxidation was 119 +/- 8 and 105 +/- 5 g, and exogenous glucose oxidation was 137 +/- 4 and 227 +/- 13 g (P less than 0.005) in groups G 200 and G 400, respectively. Endogenous glucose oxidation was about half in G 400 of what it was in G 200: 106 +/- 27 vs. 204 +/- 24 g (P less than 0.02). During the last hour of exercise, exogenous oxidation represented 55.3 and 87.5% of total carbohydrate oxidation for groups G 200 and G 400, respectively.(ABSTRACT TRUNCATED AT 250 WORDS)

3-Hydroxybutyric Acid↗

Utilization of oral sucrose load during exercise in humans. Effect of the alpha-glucosidase inhibitor acarbose.

We investigated the hormonal and metabolic response to a 100-g sucrose load given 15 min after adaptation to moderate-intensity (50% VmaxO2) long-duration (4-h) exercise in healthy volunteers. The effect of a 100-mg dose of the alpha-glucosidase inhibitor Acarbose ingested with the sucrose load was also investigated. "Naturally labeled [13C] sucrose" was used to follow the conversion to expired-air CO2 of the sugar ingested by isotope-ratio mass spectrometry. Circulating hormone and metabolite data were obtained in nine subjects, and indirect calorimetry and stable isotope methodology were applied to six of them. Under placebo, 93 +/- 4 g sucrose were entirely oxidized during the 4 h of exercise, total carbohydrate utilization was 235 +/- 14 g, endogenous carbohydrate utilization was 142 +/- 13 g, and total lipid oxidation was 121 +/- 7 g. A single oral dose of 100 mg Acarbose ingested with the sucrose load did not significantly modify total carbohydrate (239 +/- 2 g/4 h) or lipid (122 +/- 6 g/4 h) oxidation. In contrast, sucrose oxidation was reduced to 53 +/- 6 g/4 h and endogenous carbohydrate utilization increased to 186 +/- 7 g/4 h. Reduction of the rises in blood glucose and fructose and of the increases in plasma insulin and C peptide under Acarbose confirmed these effects, whereas lower circulating levels of alanine suggested a higher rate of gluconeogenesis. These data show that a 100-g glucose load ingested soon after initiation of exercise is a perfect available metabolic substrate.(ABSTRACT TRUNCATED AT 250 WORDS)

Acarbose↗

Metabolic adaptations in post-exercise recovery.

To investigate further the hormonal and metabolic adaptations occurring when carbohydrates are ingested after prolonged exercise, we have compared the fate of a 100-g oral glucose load (using 'naturally labelled' 13C-glucose) in healthy volunteers after an overnight fast at rest either without previous exercise or after a 3-h exercise performed on a treadmill at about 50% of the individual VO2 max. In comparison to the control conditions, the oral glucose tolerance test (OGTT) performed in the post-exercise recovery period was characterized by a greater rise in peripheral blood glucose levels and delayed insulin response. Plasma glucagon values were significantly elevated at the time glucose was given (+48 +/- 13 pg ml-1) and at the end of the OGTT. Plasma-free fatty acid (FFA) levels were 1675 +/- 103 microEq 1-1 when glucose was given, and subsequently reduced to values similar to those observed in the control conditions. Indirect calorimetry indicated that OGTT in post-exercise recovery was associated with decreased carbohydrate and increased lipid oxidation when compared to control conditions. Exogenous glucose oxidation was also significantly reduced: 21.1 +/- 2.6 vs. 35.9 +/- 1.9 g per 7 h. We suggest that the higher plasma glucagon levels and the delayed insulin response played a role in the decreased hepatic glucose retention previously described by others in post-exercise recovery. Our data also suggest that the higher lipid oxidation rate observed at the time glucose was given in the post-exercise period could explain, according to the Randle 'glucose-fatty acid cycle', the decreased carbohydrate oxidation and the preferential muscle glycogen repletion already well documented. The reason why the lipid oxidation rate remains increased 3-7 h after glucose ingestion in spite of the fact that FAA levels at that time are similar to those observed in control conditions is still unknown; further kinetic studies are needed to clarify this point.

Adaptation, Physiological↗

Fate of exogenous glucose during exercise of different intensities in humans.

The extent to which an oral load of glucose is absorbed from the gut and oxidized during prolonged exercise is a matter of controversy. Four healthy volunteers, 18-28 yr, were submitted on 4 different days to a 105-min treadmill exercise at 22, 39, 51, and 64% of their individual VO2max. After 15 min adaptation to exercise, they received orally 100 g naturally labeled [13C]glucose. Oxidation of the exogenous glucose was followed by 13CO2 measurements in the expired air; total carbohydrate and lipid oxidation were evaluated by indirect calorimetry. Between 22 and 51% VO2 max, total carbohydrate, lipid oxidation, and exogenous glucose oxidation were linearly correlated with the relative work load (r = 0.81; P less than 0.01). Between 51 and 64% VO2 max, exogenous glucose oxidation and lipid oxidation tended to level off, whereas endogenous carbohydrate oxidation was markedly enhanced. The lesser contribution of exogenous glucose during the most intense exercise might be due to a decrease in the oxidation in the muscles or to a lesser availability of this exogenous glucose.

Adult↗

Glucose oxidation in relation to the size of the oral glucose loading dose.

Using "naturally labeled 13C-glucose" the conversion to expired air CO2 of 100, 66 and 33 g oral glucose loads was evaluated, during 7 hr, in 6 male healthy volunteers. The total amounts of exogenous glucose converted to expired air CO2 were proportional to the loading doses and averaged, in g/7 hr, 14.6 +/- 2.1 for 33 g, 20.8 +/- 2.1 for 66 g and 31.2 +/- 1.6 for 100 g. In contrast total glucose oxidation, evaluated by indirect calorimetry, was similar in the three groups and was not correlated with the dose of glucose given. The plasma insulin response was significantly correlated with the load of glucose (r = 0.86; p less than 0.001) whereas such correlation was not observed with the blood glucose response. Comparison with data available in the literature on the influence of the size of the oral glucose load on endogenous glucose production and on splanchnic glucose output suggests that the greater oxidation of exogenous glucose seen when the oral load of glucose is increased essentially results from a greater enrichment of the systemic glucose pool with exogenous glucose.

Adult↗

A wavelet-based method for removal of out-of-plane structures in digital tomosynthesis.

Reconstructed images in digital tomosynthesis (DTS) are affected by artifacts due to blur from planes other than the fulcrum plane. A wavelet-based method has been developed for the discrimination and subsequent removal of unrelated structures from the reconstructed plane. The approach exploits both the specific pattern of noise in DTS and the spatial locality of the wavelet transformation. The technique was implemented on a DTS clinical protoype system. Experimental evaluation on angiographic types of images demonstrated excellent noise differentiation and elimination. The method is therefore particularly useful for certain medical imaging applications such as vascular DTS imaging.

Angiography↗

Q-Pro: a quality control management system for medical equipment.

Q-Pro is an application for quality control (QC) and inspection of medical equipment. The system has been designed on the basis of a broad requirements analysis, contributed by clinical engineers from several European countries and with a focus on current and forthcoming regulatory requirements concerning the quality control and risk management for medical equipment. Q-Pro comprises a generalized application, providing the necessary flexibility to accommodate the different degrees of difficulty and specialization in creating or customizing QC protocols, carrying out inspections and managing collected data. The system incorporates a tool library for QC protocol design, widely used multimedia as well as a local database for protocol and inventory data archiving. The paper presents a detailed account of the system context of use, design and functionality.

Equipment and Supplies↗