Test of 20 similar intensive care ventilators in daily use conditions--evaluation of accuracy and performances.

Infrequent control, aging of components, may compromise the accuracy of ICU ventilators. In order to assess the reliability of ventilators during their clinical use, we bench tested a group of 20 CPU1 ventilators (Ohmeda) sampled at random in several ICU units. We found major leaks in 5 ventilators, attributable to the disposable tubings used in these systems. Mean error in expired tidal volume and corresponding standard deviation (precision) were greater than 100 ml in two. Positive end expiratory pressure measurement comprised a mean error higher than 2 cm H2O in 40% of the ventilators tested. The valve opening pressure threshold was correlated to the inspiratory flow (r = 0.81) contrary to the valve opening delay (average 138 +/- 40 ms). These two parameters did not correlate with the age of the ventilator. Our study addresses the need for periodic control of ventilator performance in order to minimize the risks of errors and malfunctions.

Age Factors↗

Single- versus triple-lumen central catheter-related sepsis: a prospective randomized study in a critically ill population.

PURPOSE: A prospective randomized study was conducted over a 23-month period in an adult medical-surgical intensive care unit to determine whether triple-lumen catheters reduce the need for peripheral vascular access and whether they are associated with a higher rate of infection than single-lumen catheters. PATIENTS AND METHODS: After the insertion route, internal jugular or subclavian, was selected by the physician, patients were randomized either to single-lumen or triple-lumen catheter groups. Complementary peripheral vascular access was allowed in both groups. Catheters were removed according to preestablished defined reasons: suspicion of catheter-related sepsis, uselessness of central venous access, duration of catheterization of more than 21 days, discharge from the intensive care unit, or death. RESULTS: Data on 129 central venous catheters were collected from 91 consecutive patients. Twenty-five of 68 patients from the single-lumen group and 1 of 61 patients from the triple-lumen group needed peripheral vascular access (p less than 0.001). Catheter-related sepsis rates, defined either by clinical signs and positive qualitative tip cultures (8.9% versus 11.5%) or by quantitative tip cultures (16.2% versus 11.5%), were identical in the single-lumen and triple-lumen groups (type II error: 8%). CONCLUSION: In intensive care units, the use of triple-lumen catheters is associated with a dramatic decrease in the need for peripheral vascular access. The incidence of central venous catheter-related sepsis appears identical for single- and triple-lumen catheters.

Adult↗

[A study of 11 ventilators for anesthesia: laboratory testing].

Eleven anaesthesia ventilators were instrumentally tested under various conditions. They included: Excel and Modulus II Plus (Ohmeda); 710 and Servo anaesthesia circle 985 (Siemens); Jollytronic (Soxil) and Elsa (Engström); SA2 and Cicero (Dräger); ABT 4,300 (Kontron); Monnal A and the prototype Alys (Taema). The test circuit comprised a two compartment model lung, a pneumotachograph, a pressure gauge in the "airway". The volume was calculated as the integral of flow rate. Each machine was calibrated by the firms' technicians. Before each test, the pneumotachograph was calibrated using a 11 air syringe and the pressure gauge with a 5 cm water column. Each machine ventilated the model lung for 30 min before starting the tests. There were five tests: 1) reliability of the machine's spirometer, 2) reliability of the ventilation rate, 3) reliability of pressure measurements, 4) effect of increasing fresh gas flow on spirometry, 5) effect of increasing downstream resistances. In usual simulated ventilatory conditions, all the machines accurately delivered the setted ventilation and spirometric measurements were with minimal error only. Several ventilators (SA2, Excel, 710, Elsa, ABT 4,300) did not succeed in maintaining their performances when compliance was strongly decreased or resistance of the test lung notably increased. Resistance in the circuit during simulated spontaneous ventilation was < 3.6 cmH2O.l-1.s-1. Increasing fresh gas flow raised the minute volume delivered in six ventilators. It is concluded that, during extreme ventilatory conditions, the inspired volume must be adjusted so as to maintain the inspired tidal volume. However, ventilators which increase inspiratory time in response to an increased mechanical load cannot be adjusted by this way.

Anesthesia, Closed-Circuit↗

A dose-range study of intrathecal meperidine combined with bupivacaine.

Twenty-one patients were included in a randomized study to receive either 10 mg of 0.5% hyperbaric bupivacaine alone or combined with 0.05, 0.1, 0.2, 0.3, 0.4 or 0.5 mg.kg-1 meperidine for spinal anaesthesia. Sensory blockade was assessed by pin prick, motor blockade by the Bromage scale, and postoperative analgesia by VAS scores and by the time before the first demand for analgesia. Spinal meperidine did not change the duration of sensory blockade, but induced a dose-related increase in postoperative efficient analgesia. Spinal meperidine might be considered as a means to obtain postoperative analgesia in the hours immediately following surgery.

Aged↗

Effect of preoperative normovolemic hemodilution on left ventricular segmental wall motion during abdominal aortic surgery.

Preoperative normovolemic hemodilution (PNH) has been proposed for patients scheduled to undergo aortic surgery. Coronary artery disease is frequent in these patients. The aim of the study was to assess the effect of PNH on hemodynamics and segmental wall motion (SWM) evaluated by transesophageal echocardiography in such patients. Twenty patients with coronary artery disease were allocated randomly to either PNH or no PNH; PNH was performed after anesthetic induction using dextran 60,000. Patients were operated on under general anesthesia and monitored intraoperatively with electrocardiographic lead CM5, radial and pulmonary artery catheters, and transesophageal echocardiography positioned to obtain a short-axis view. Hemodynamic and transesophageal echocardiographic data were collected after anesthetic induction and after PNH, before and 5 min after aortic clamping, after unclamping, and at the end of surgery. Aortic clamping induced a significant increase in systemic vascular resistance and arteriovenous difference in oxygen and a decrease in cardiac index (P < 0.05), but the effect of aortic clamping was inversely related to hemodilution. The SWM score (graded from 1 = normal to 5 = dyskinesia) was significantly increased after aortic clamping, mainly in the anterior segment (P < 0.05). Four patients in the control (no PNH) group and one in the PNH group developed new SWM abnormalities indicative of myocardial ischemia during surgery (P = NS). This study suggests that PNH may improve hemodynamic tolerance to aortic clamping in patients with coronary artery disease. The observed changes in SWM indicate that PNH may not worsen myocardial ischemia in patients scheduled to undergo aortic surgery.

Aged↗

Can portable chest x-ray examination accurately diagnose lung consolidation after major abdominal surgery? A comparison with computed tomography scan.

PURPOSE: To prospectively quantify the degree of accuracy of portable chest x-ray film examination in the detection of postoperative lung consolidations. STUDY: Nineteen patients had a chest x-ray film and computed tomography (CT) scan the day before and 48 h following elective abdominal aortic replacement. RESULTS: The diagnosis of lung consolidations by x-ray film examination showed sensitivity of between 0.33 and 1.00, depending on the lung zone considered (lower at the lung bases). Specificity always was greater than 0.79. Radiologic lung volume decreased 16 percent postoperatively (p < 0.01) on average and noninflated parenchyma increased by a factor of 3 (p < 0.0001). Postoperatively, PaO2 correlated with the amount of condensed lung by CT scan (p < 0.002). CONCLUSION: In postoperative conditions, x-ray film examination is a method which presents good specificity but poor sensitivity in the diagnosis of lung consolidations.

Abdomen↗

[The effect of 211At labelled monoclonal antibody against gastric cancer on DNA, RNA and protein synthesis in gastric cancer cell].

By means of nuclide precursor incorporation, the effects of 211At labelled monoclonal antibody against gastric cancer (211At-3H11McAb) on DNA, RNA and protein synthesis in gastric cancer cell were studied. The results show that 211At-3H11McAb and Na211At-3 inhibit 3H-TdR, 3H-UR and 3H-Leu incorporation, especially 3H-UR incorporation, into gastric cancer cell at 3.7 x 10(4)Bq and 1.85 x 10(5)Bq; the inhibiting rates depend on concentration. The DNA biosynthesis in gastric cancer cell gradually recover after the drug is removed, suggesting that the drug should exert an inhibiting action on DNA biosynthesis in tumor cell through interference of DNA metabolism.

Antibodies, Monoclonal↗

Selection of high-level abamectin resistance from field-collected house flies, Musca domestica.

Abamectin is a novel, highly promising insecticide with activity against many pests. To determine if resistance to abamectin could occur, we collected house flies from several New York dairies and selected them in the laboratory. Resistance developed rapidly and to a high level (36 or greater than 60,000-fold, depending upon test technique and/or adjuvant) that could not be overcome by the synergists piperonyl butoxide or S,S,S-tributylphosphorotrithioate. There was no increase in (cross)resistance to crotoxyphos, dichlorvos, dimethoate, tetrachlorvinphos, permethrin, dieldrin or lindane following abamectin selection. Our results suggest the potential for abamectin resistance is high, at least in house flies, and that the judicious use of abamectin will be needed to prolong its usefulness as an insecticide.

Animals↗

[Analysis of failures of spinal anesthesia as a function of practice development in a university hospital].

This study is a retrospective analysis of 303 consecutive spinal anaesthesia performed in orthopaedic patients of a University Hospital between January and December 1990. Failure of spinal anaesthesia was defined as the requirement for general anaesthesia to perform surgery. The parameters studied as possible risk factors of failure were patients demographics, local anaesthetic agents and solutions and techniques of spinal anaesthesia (single injection versus continuous spinal anaesthesia). Failures were related to inadequate or incomplete extension of sensory blockade or to difficulties to perform spinal injection. Continuous spinal anaesthesia was performed in 209 patients mostly with 0.5% isobaric bupivacaine, while 94 patients received a single injection of either hyperbaric 0.5% tetracaine with adrenaline or 0.5% bupivacaine or 5% lidocaine. Failures occurred in 6.3% of the cases but were significantly less frequent with continuous spinal anaesthesia (4.8%) than with the conventional technique (9.6%). The incidence of failure was higher with hyperbaric tetracaine (11.1%) confirming its poor reliability. Inadequate extension of the anaesthetic block was the main cause of failure whatever the spinal anaesthetic technique. These results point out the reliability of continuous spinal anaesthesia but problems may occasionally occur due to spinal catheter misplacement.

Academic Medical Centers↗

[Pharmacology and mechanism of action of opiates administered by the subarachnoid route].

The sites of action of spinally administered opiates are specific receptors (mu kappa delta) located in the spinal dorsal horn. Pharmacokinetics of spinally administered opiates are determined by their lipophilic property. Morphine has a weak octanol-water partition coefficient and remains in the CSF during a long period following the cephalic movements of lumbar CSF to the supraspinal structures. More lipophilic opiates are rapidly eliminated from the CSF. Nevertheless, significant pethidine concentrations are documented in the ventricular CSF, due to vascular absorption of the drug. Pharmacokinetics features of different opiates determine the duration of analgesia and the risk of respiratory depression after spinal injection.

Analgesics, Opioid↗

Expression of calf prochymosin gene in Escherichia coli.

The expression plasmid pTaAC containing Tac promoter and calf prochymosin B gene was constructed and transformed into E.coli JM105. Addition of 0.1 mM IPTG into the culture at logarithmic phase induced the production of prochymosin markedly. The expression of prochymosin gene was regulated by temperature in addition to the inducer IPTG. At 30 degrees C in the presence of IPTG prochymosin was barely detected, whereas at 42 degrees C in the absence of IPTG a relatively high level of prochymosin was found. The expressed protein was estimated to be 12-19% of total cell proteins by electrophoresis analysis or 80-100 mg/l by ELISA. The yield of active chymosin was 14-20 mg/l after denaturation, renaturation and activation.

Animals↗

[The role of nucleus tractus solitarii (NTS) in acupuncture inhibition of visceral-somatic reflex (VSR)].

Experiments were carried out on 164 rabbits. The transmission of abdominal vagal impulses and the mechanism of inhibitory effect by acupuncture systematically were investigated. 1) Electrical stimulation (single pulse of 20 V, 0.5 ms) of abdominal vagus nerve (AVN) produced two kinds of potential on cervical vagus nerve: the fast wave (10.4-24.4 M/sec) and the slow wave (0.9-1.7 M/sec), the later was more stable. 2) In dorsal medulla oblongata the 'M' shaped evoked potentials with long duration (100 ms or so) were recorded. The results suggest that afferents from AVN are mainly transmitted through the small fibres and multi-synaptic connections in Medulla. 3) Out of 301 response units, 281 units (93.6%) concentrated in NTS and adjacent regions. This result was also confirmed by injection of Horseradish Peroxidase (HRP) in the trunk of AVN. 4) On 24 awake rabbits the VSR were elicited by strong stimulation of AVN. Electroacupuncture (EA) on "Zusanli" points inhibited VSR, an effect lasted over 20 min. This inhibitory effect of EA was reversed partly by Naloxone (0.5 mg/kg iv) and was attenuated after lesion (DC 0.5 mA, 1 min.) of NTS. In conclusion, NTS plays an important role in suppression of VSR by EA (P less than 0.01).

Abdominal Pain↗

Site-directed mutagenesis of recombinant rat DNA polymerase beta: involvement of arginine-183 in primer recognition.

By site-directed mutagenesis using synthetic oligonucleotides, amino acid residues 181Phe-Arg-Arg183 of recombinant rat DNA polymerase beta were replaced by other amino acids to clarify the roles of these residues in the DNA synthesizing reaction. Replacement of Phe-181 by alanine reduced the enzyme activity only 30%. Replacement of Arg-182 by alanine and glutamine resulted in reduction of the activity by about 67% and 95%, respectively. The Arg-182----Gln replacement increased the binding strength to single-stranded DNA but did not significantly change the Km's for the primer and dTTP, suggesting that Arg-182 is involved in modulation of binding to the template rather than to the primer or deoxyribonucleoside triphosphate. Replacement of Arg-183 by Gln resulted in reduction of the activity by about 95%, and this change, although causing little change in binding strength to single-stranded DNA, resulted in a 3-4-fold increase in the Km's for the primer and deoxyribonucleoside triphosphate. A more dramatic change was observed when Arg-183 was replaced by Ala, which resulted in a 99.98% reduction of enzyme activity. Although the Km for deoxyribonucleoside triphosphate of this mutant enzyme was hardly changed, that for the primer increased 159-fold. Therefore, it is concluded that Arg-183 occupies an important part of the primer recognition site of DNA polymerase beta.

Amino Acid Sequence↗

[Opening of a foramen ovale during liver transplantation. The value of transesophageal echocardiography].

A case is reported of a foramen ovale becoming patent during orthotopic liver transplantation (OLT). The patient had a hepatoma secondary to post-hepatitis cirrhosis. Monitoring included transesophageal echocardiography (TEE). A veno-venous shunt between the right femoral, portal and left axillary veins was used so as to maintain the venous return during portal and caval clamping. The patient's haemodynamic state remained quite stable throughout this period, and no vasoactive drug was required. Five min after graft reperfusion, pulmonary arterial pressure increased suddenly (mean PAP: 27 mmHg). TEE revealed paradoxical movements of the atrial septum. Colour coded Doppler ultrasound showed blood flowing from the right to the left atrium through a patent foramen ovale. Fifteen min later, mean PAP decreased (18 mmHg) and TEE no longer showed any flow between the two atria. Several studies have reported transient pulmonary hypertension after unclamping when the donor liver is reperfused. This could induce right ventricular failure, with transient inversion of the atrial pressure gradient, which, in turn, could result in a right-to-left shunt through a patent foramen ovale. TEE can monitor regional and overall left ventricular function as well as the atrial septum. This technique might therefore to be useful for cardiac monitoring during OLT.

Cardiomyopathies↗