Search PubMed⌕ Search

Biomedical subjects

N Lange

Publications and source records attributed to N Lange.

At least 55 records · Page 3Linked to original sources

Some computational and statistical tools for paired comparisons of digital images.

This article is a case-based review that introduces applied statisticians to a number of issues and methods that arise in clinical studies with paired digital images as outcomes. Single photon emission computed tomography (SPECT) is the imaging modality used in two examples. The first is a physical simulation of relevant clinical features of SPECT images using a customized head phantom scanned under different experimental conditions. The objective is to demonstrate and compare several current methods for image registration, i.e., image superimposition in some optimal manner to obtain a common frame of reference within which to make pixel-by-pixel comparisons. Image registration together with image normalization to correct for spurious differences in background activity levels enable quantification of differences in paired images. The physical simulation assesses quantification accuracy. The second example involves two SPECT images of the same brain tumour patient taken about two months apart. The objective here is to demonstrate several tools from morphological image analysis for image segmentation, i.e., separation of 'figure' and 'ground', and simple image regression to detect patterns of differences in time, again after registration and normalization. The clinical context of both examples helps to keep the review in practical focus and is a useful starting point for descriptions of many standard tools in applied medical image analysis. References to relevant literature are provided for readers wanting to study particular subjects in depth. As medical image analysis becomes more sophisticated, more cost-conscious and scrutinized more intensively, proper attention to the computational and statistical bases for practical conclusions become even more crucial.

Brain Neoplasms↗

[The use of the HET-CAM test for the determination of the irritating effects of humic acids].

Using the synthetic humic acid product HS 1500 and the native product Sodium-Humate, the suitability of the HET-CAM-test to evaluate irritating effects was tested. Neither sensitizing nor irritating properties were detectable in concentrations of up to 10% in either humic acid solution. This leads us to the conclusion that both products are very mildly acting substances on mucous membranes and skin, causing no irritative effects. In order to improve the certainty of these results, it is still currently recommended to carry out the Draize-test in addition to the HET-CAM procedure (SPIELMANN, 1992). We are convinced that the HET-CAM-test can be a very useful first step in distinguishing between irritative and non irritative substances and in protecting animals from pain, even in the event that the results of both tests do not clearly correspond to each other. Taking into account the results of our experiments, a modified HET-CAM-test also seems to be useful to predict the antiphlogistic effects of chemical substances.

Animal Testing Alternatives↗

Electrical stimulation for idiopathic scoliosis.

To evaluate the effectiveness of lateral electrical spinal stimulation for idiopathic scoliosis, 87 patients treated with this modality were reviewed retrospectively. All patients had no prior treatment, had a documented progression of more than 5 degrees, and were skeletally immature. Forty-seven patients were compliant and followed until skeletal maturity or institution of other treatment. Fifty percent of patients with a high probability of progression required surgery. For compliant patients, 51% progressed 5 degrees or more and 36% progressed 10 degrees or more or required a change to another treatment modality. Statistical analysis demonstrated no significant difference in the probability of progression between this group of treated patients and previously published groups of untreated patients.

Adolescent↗

[The hexobarbital sleeping time in a pharmacologico-toxicological experiment with special reference to age and chronobiologically-limited variations in Wistar rat strain WIST/Lppt].

Investigations were performed to determine the hexobarbital sleeping time (HST) of a strain of Wistar rats (WIST/Lppt). Another aim of the studies was to demonstrate possibilities to use the HST as a method to get additional informations during pharmacological and toxicological experiments. The age--and sex--dependent changes in the hexobarbital sleeping time of the investigated strain of rats are in coincidence with results of other authors, using different rat strains. Additionally, the HST more or less depends on circadian and circannual rhythm. It was stated that the HST as a prescreening-method before starting investigations in detail is of great importance.

Age Factors↗

Poly(anhydride) administration in high doses in vivo: studies of biocompatibility and toxicology.

Poly(anhydrides) proposed for use as vehicles for controlled drug delivery were administered subcutaneously in Sprague-Dawley rats at two dosage levels (800 mg/kg rat and 2400 mg/kg rat) for a period of eight weeks. Biocompatibility was assessed using a number of methods. Thirty-six clinical chemistry and hematology parameters were monitored throughout the study. Blood values were statistically analyzed for any possible effects due to the implanted polymer. After 8 weeks, rats were sacrificed and complete necropsies were performed. Histological evaluations of 33 organ sites including heart, lung, liver, kidney, and brain were performed. In addition, subcutaneous implant sites were excised and examined both grossly and microscopically. Results from evaluations of blood chemistry and hematology data, organ analyses and local implant site analyses overall demonstrated that the poly(anhydride) biomaterial possessed excellent in vivo biocompatibility.

Animals↗

Evaluation of Minibact, a new system for rapid identification of Enterobacteriaceae. Comparison of Minibact, Micro-ID and API 20E with a conventional method as reference.

Minibact, a new system for four-hour identification of Enterobacteriaceae, combined with a computer identification system, was compared with Micro-ID and API 20E in testing 110 strains of Enterobacteriaceae. Minibact gave identification rates of 96.4% at species level and 96.4% at genus level; the corresponding values for Micro-ID were 87.3% and 91.8%, and for API 20E 91.8% and 94.5%. In conclusion, Minibact combined with a computer identification program gave high identification rates fully comparable to those of Micro-ID and API 20E, and the system might be an alternative to conventional identification systems in clinical microbiological departments.

Bacteriological Techniques↗

A computerized patient registration and treatment randomization system for multi-institutional clinical trials.

Computerized registration and randomization for a cooperative clinical trials group is a useful addition to its data gathering and managing process. An automated system eliminates unnecessary paperwork, allows more sophisticated randomization algorithms to be implemented, and makes available a variety of computer-generated reports such as confirmation of registration forms, accrual results, and other statistical tables. This paper describes the design and implementation of such a system for a relatively large cooperative group, the Eastern Cooperative Oncology Group (ECOG), as well as gives general recommendations for conversion of a manual registration and randomization process to an automated one. Our general interactive system, known as PRS for Patient Randomization System, was designed to be easily expandable as its functions increase over time, and transportable to other clinical trials settings.

Clinical Trials as Topic↗

Statistical thinking in functional and structural magnetic resonance neuroimaging.

Burning issues abound in the emerging field of biostatistics for imaging studies of the living human brain. This paper employs two examples to discuss the roles of informed empirical models and modern statistical methods in the analysis of functional and structural magnetic resonance neuroimages. The first example derives from an analysis of a functional baseline study in which simulated signals are embedded in actual brain 'noise' generated by a resting subject lying passively in the imaging device. The second example is taken from a structural volumetric analysis of human brain structure size differences in a sample of healthy adults.

Analysis of Variance↗

Graphs and stochastic relaxation for hierarchical Bayes modelling.

This expository paper describes two useful tools for the statistical analysis of processes that generate repeated measures and longitudinal data. The first tool is a graph for a visual description of dependency structures. The second tool is a stochastic relaxation method ('Gibbs sampling') for fitting hierarchical Bayes models. Graphs are concise and accessible summaries of stochastic models. Graphs aid communications between statistical and subject-matter scientists, during which formulations of scientific questions are modified. An uncluttered picture of the dependency structure of a model augments effectively its corresponding formulaic description. Stochastic relaxation is a computationally intense method that allows experimentation with broader classes of models than were previously thought feasible because of analytic intractability. Stochastic relaxation is intuitive and easily described to non-statisticians. Several sample graphs show how hierarchical Bayes models can use stochastic relaxation to obtain their fits. An example based on estimating drug shelf-life demonstrates some uses of graphs and stochastic relaxation compared with several frequentist growth curve analyses that use restricted maximum likelihood and generalized estimating equations approaches.

Bayes Theorem↗