Search PubMed⌕ Search

Biomedical subjects

N K Chou

Publications and source records attributed to N K Chou.

54 records · Page 3Linked to original sources

HeartMate left ventricular assist device for long-term circulatory support.

We describe three successful cases of HeartMate left ventricular assist device (LVAD; Thermo Cardiosystems, Woburn, MA, USA) implantation in patients with end-stage heart failure for long-term circulatory support. Patient 1 was a 34-year-old woman with postpartum cardiomyopathy. Patients 2 and 3 were both males with dilated cardiomyopathy, 50 years and 21 years of age, respectively. They all presented in cardiogenic shock with decreased sensorium and anuria. Temporary mechanical support with an intra-aortic balloon pump or extracorporeal membrane oxygenation (ECMO) was needed for life support. Because bleeding and right ventricular failure often occur after HeartMate LVAD implantation, we used a Vascutek tube (Vascutek Ltd, Inchinnan, Scotland) graft to wrap inflow and outflow valve conduits and ECMO as a bridge to HeartMate LVAD implantation. Following surgery, cardiac output increased from 2.70, 2.06 and 2.53 L/min to 4.50, 5.80 and 5.00 L/min in the three patients. HeartMate LVAD can provide safe and stable long-term circulatory support without the need for anticoagulation. One of the patients remained on HeartMate for 287 days before undergoing successful heart transplantation. Patients with HeartMate LVAD are ambulatory and may be discharged while awaiting heart transplantation. Heart function may recover after long-term ventricular unloading with HeartMate LVAD.

Adult↗

Rescue for acute myocarditis with shock by extracorporeal membrane oxygenation.

BACKGROUND: Acute myocarditis (AM) complicated with refractory cardiogenic shock carries a very high mortality. We report our experience in treating these patients, who were rescued by extracorporeal membrane oxygenation (ECMO) and intravenous immunoglobulin. METHODS: Over a 5-year period, 5 patients with AM were rescued with ECMO in our hospital. Femoral venoarterial ECMO was performed in 4 patients, and right atrium-left atrium-aorta ECMO in the other 1 due to ventricular dysfunction. Hemofiltration was applied to 3 patients. Marked elevated creatine kinase, its MB form, and troponin T (TnT) were found before ECMO. RESULTS: All the patients could be weaned off the ECMO after 140.0+/-57.7 hours of ECMO support. One patient died of multiple organ failure 10 days later after removal of ECMO, resulting in a 20% mortality. Renal function returned to normal in all survivors. The 4 survivors were discharged uneventfully in 23.3+/-8.3 days and resumed functional class I status. The TnT level declined to the low level within 3 days (slope -4.94+/-1.18 ng/mL/day), and might be an indicator of good recovery of myocardium. CONCLUSIONS: ECMO can provide an effective and simple treatment for critical AM with a satisfactory result and reduce the possibility of progressive cardiomyopathy.

Acute Disease↗

Low incidence of transplant coronary artery disease in Chinese heart recipients.

OBJECTIVES: This study sought to assess the incidence of transplant coronary artery disease (CAD) in Chinese heart recipients. BACKGROUND: The prevalence of transplant CAD detected by angiography at 1, 2 and 4 years after heart transplantation was 11%, 22% and 45%, respectively. The incidence of transplant CAD in Chinese heart recipients has not been reported. METHODS: For those recipients surviving for more than 1 year after transplantation, coronary angiography was performed annually for surveillance of transplant CAD. The recipient characteristics, donor characteristics, rejection episodes, medication and human leukocyte antigen (HLA) mismatches were recorded. RESULTS: Fifty patients were included in this study. Thirteen (26%) recipients had ischemic heart disease. Two patients (4%) had active cytomegalovirus (CMV) infection after transplantation. The mean number of rejection episodes in the 1st year after transplantation was 1.15. Among 47 patients with complete data of donor and recipient histocompatibility antigens, there were seven patients (14.9%) with two or fewer HLA mismatches. Among 74 angiograms of 50 patients reviewed, only one patient had discrete stenosis less than 50% in the middle portion of the left anterior descending artery at 1 year after transplantation. The cumulative incidence of transplant CAD was 2% at 1 year and 2% at 2 and 4 years after transplantation. CONCLUSIONS: The incidence of transplant CAD was low in Chinese heart transplant recipients. Low percentage of ischemic heart disease in recipients, low occurrence of active CMV infection and rejection episodes after transplantation, less racial disparity, and lower HLA mismatches may be the important factors.

Adolescent↗

Cardiorespiratory response of heart transplantation recipients to exercise in the early postoperative period.

In this study, we evaluated the cardiorespiratory function of orthotopic heart transplantation (OHT) recipients during exercise. Seventeen male OHT recipients, ranging in age from 22 to 60 years, participated in this study 47 +/- 21 days after surgery. The control group consisted of 17 sedentary healthy men. Breath-by-breath measurement of cardiorespiratory function was obtained during the incremental exercise of leg cycling. At peak exercise, the oxygen (O2) uptake (16.5 +/- 3.3 vs 33.9 +/- 8.2 mL.kg-1.min-1), work rate (82 +/- 19 vs 169 +/- 42 watts), heart rate (HR), O2 pulse, and blood lactate level of the OHT recipients were significantly lower than the respective values of the control group. At the ventilatory threshold, the OHT group also showed a significantly lower O2 uptake (10.7 +/- 1.6 vs 18.3 +/- 5.1 mL.kg-1.min-1), work rate (39 +/- 12 vs 89 +/- 33 watts), HR, O2 pulse, ventilatory equivalent for O2, and ventilatory equivalent for carbon dioxide. The OHT recipients showed a high resting HR (97 +/- 7 beats/min) and a low peak HR (123 +/- 14 beats/min) during exercise, and their HR continued to increase for 1 to 3 minutes after cessation of exercise. Our data revealed a low level of cardiorespiratory endurance in OHT recipients during the early postoperative stage. A multidisciplinary cardiac rehabilitation program should be considered to enhance physical functional capacity and quality of life, and promote return to work.

Adult↗

Heart transplantation with marginal recipients and donors.

With improvements in surgical techniques and management of postoperative complications, heart transplantation can now be performed with donors and recipients who were previously considered unsuitable. In this study, we report the results of heart transplantation with marginal donors and recipients in our hospital. From June 1993 through June 1998, we performed 79 heart transplantations. Marginal recipients were defined as those with high pulmonary vascular resistance (> 6 Wood units), severe renal impairment (serum creatinine > 2 mg/dL and creatinine clearance < 50 mL/min), or severe hepatic dysfunction (ALT and AST > 100 IU/L or serum bilirubin > 2.5 mg/dL). Marginal donors were those with any of the following conditions: old age (> 40 years), size mismatch (donor/recipient body weight ratio < 0.8), history of chronic alcohol use, previous cardiopulmonary resuscitation and hypotension, hepatitis B or C virus positivity, coronary artery disease, high-dose dopamine (> 10 micrograms.kg-1.min-1), or prolonged allograft ischemic time (> 4 hours). Of the 79 transplantations performed, 45 (58%) involved marginal recipients or donors. The 30-day mortality rate was 5%, and the 1-year and 5-year survival rates were 87% and 83%, respectively. The survival rates did not differ significantly between cases involving marginal donors or recipients and those involving nonmarginal donors and recipients. There were 27 marginal recipients (34%), only one of whom died during surgery. Five of six recipients with severe renal impairment needed short-term hemodialysis after transplantation. Recipients with high pulmonary vascular resistance had a higher incidence of early acute rejection (5/10 vs 22/69). Thirty-three (42%) of the patients received transplants from marginal donors, four of whom died during surgery; two died of acute vascular rejection, one of allograft failure caused by prolonged ischemic time, and one of bleeding secondary to preoperative sepsis and coagulopathy. These results show that heart transplantation may be performed in marginal recipients and donors, with acceptable operative mortality.

Adolescent↗

Extracorporeal membrane oxygenation in treatment of cardiogenic shock caused by acute myocarditis.

We report a 31-year-old woman with acute myocarditis who was transferred to our hospital because of rapidly progressive cardiogenic shock unresponsive to infusion of high doses of inotropic agents and intraaortic balloon pump support. Upon arrival at our hospital, extracorporeal membrane oxygenation (ECMO) was immediately established through a right femoral venoarterial route by percutaneous cannulation; the blood flow of ECMO was maintained at around 2,100 mL/min. Shock-induced rhabdomyolysis complicated with acute renal failure occurred. During treatment with ECMO and hemodialysis, the patient gradually recovered cardiac and renal function. The patient was maintained on ECMO for 90 hours then successfully weaned from the machine without major complications. Our experience suggests that ECMO can be used for temporary mechanical circulatory support in patients with cardiogenic shock due to acute myocarditis.

Acute Disease↗

Extracorporeal membrane oxygenation in the perioperative period of heart transplantation.

Mechanical circulatory support is occasionally needed in the perioperative period of heart transplantation. Between February and May 1995, three recipients of cardiac transplant at the National Taiwan University Hospital required the use of extracorporeal membrane oxygenation (ECMO) for temporary mechanical circulatory support in the perioperative period of heart transplantation. All three patients received ECMO through the percutaneous femoral veno-arterial route. The ECMO device has a heparin-bound Carmeda Bioactive surface and centrifugal pump. Patient 1 needed ECMO for treatment of a postoperative pulmonary hypertensive crisis. Patient 2 needed ECMO for early cardiac allograft failure, possibly due to ischemia. Patient 3 needed ECMO as a bridge to his first heart transplant after acute myocardial infarction complicated with cardiogenic shock, and again as a bridge to retransplantation because of acute failure of the first cardiac transplant and finally for a temporary circulatory support during rescue treatment for acute vascular rejection of the second cardiac transplant. All three patients were successfully treated with ECMO without major complications. In conclusion, ECMO provides excellent mechanical circulatory support for some situations in the perioperative period of heart transplantation.

Aged↗

Left atrial spontaneous echo contrast in asymptomatic patients with a mechanical valve prosthesis.

BACKGROUND: Valve thromboembolism may be a fatal complication of mechanical valve prosthesis if detected late. Spontaneous echo contrast (SEC) is a well-documented prothrombotic phenomenon; here we report it in asymptomatic patients with a mechanical valve prosthesis. METHODS: Ninety-two asymptomatic patients with a mechanical valve prosthesis for underlying rheumatic heart disease underwent transesophageal echocardiography. Appendage area, peak filling and emptying velocities of the left atrial appendage, and the presence or absence of SEC and thrombi were determined. The results of 56 patients without SEC or thrombi (group I) were compared with those of 24 patients with SEC and no thrombi (group II) and 12 patients with thrombi (group III). RESULTS: Spontaneous echo contrast was present in 39% of the asymptomatic patients with a mechanical valve prosthesis. Although 12 patients had cardiac thrombi, including valve thrombi in 4, no patients presented symptoms. Anticoagulant therapy had no significant association with SEC and atrial thrombi. There was a significantly greater prevalence of atrial fibrillation and mitral prosthesis in groups II and III than in group I. Two patterns of left atrial appendage flow were identified: one was organized biphasic flow with peak filling velocities of 41.2 +/- 17.2 cm/s and emptying velocities of 40.5 +/- 17.5 cm/s. The other showed irregular, very low peak filling velocities (104 +/- 11.5 cm/s) and emptying velocities (12.3 +/- 13.1 cm/s). The former flow pattern was associated with sinus rhythm and the latter form was associated with atrial fibrillation. CONCLUSIONS: There was a relatively high prevalence of SEC and thrombi in patients with a mechanical valve prosthesis. Patients with a valve prosthesis may not have clinical symptoms. Anticoagulation intensity was not associated with the occurrence of SEC and thrombi. Patients with the mitral valve prosthesis and atrial fibrillation were identified as a high-risk of subgroup for the development of SEC and thrombi.

Adult↗

Mechanical and electrophysiological effects of 8-oxoberberine (JKL1073A) on atrial tissue.

The effects of 8-oxoberberine (JKL1073A) on contractions and electrophysiological characteristics of atrial tissues were examined. In driven left atria of the rat JKL1073A (10-100 microM) increased twitch tension dose-dependently. In spontaneously beating right atria, JKL1073A increased twitch tension but decreased beating rate slightly. The positive inotropic and the negative chronotropic effect of 30 microM JKL1073A was not affected by prazosin (1 microM), propranolol (1 microM) and 3-isobutyl-1-methyl-xanthine (10 microM) but significantly suppressed by 4-aminopyridine (2 mM 4-AP). Current-clamp study revealed that JKL1073A prolonged rat atrial action potential duration (APD). This prolongation of APD by JKL1073A was decreased by pretreating the cells with 2 mM 4-AP. Voltage-clamp study showed that JKL1073A inhibited the integral of the transient outward current (I(to)) dose-dependently with a KD value of 3.66 +/- 0.93 microM in rat atrial myocytes. The equilibrium dissociation constant (Kd) for JKL1073A bindings to open state I(to) was 0.50 +/- 0.08 microM. The suppression of I(to) by 3 microM JKL1073A was accompanied by shortening of its inactivation time constant from 52.5 +/- 0.9 ms to 16.8 +/- 0.7 ms. V(0.5) for the steady-state inactivation curve of I(to) was shifted from -25.7 +/- 3.3 mV to -34.8 +/- 3.2 mV. In human atrial cells, similar inhibition of I(to) and prolongation of APD by JKL1073A was found. The KD value of JKL1073A for inhibition of the integral of I(to) in human atrial cells is 4.03 +/- 0.02 microM. The Kd for bindings to open state I(to) is 0.5 microM. Currents through K1 channels of rat and human atrial myocytes were not inhibited by JKL1073A at concentrations up to 10 microM. These results indicate that JKL1073A exerts a positive inotropic effect by inhibition of I(to). JKL1073A inhibit I(to) by binding to open state channels or shifting of the steady-state inactivation curve of I(to).

Animals↗

The pulsatile impeller pump for left ventricular assist.

Because of severe hemolysis, especially on producing pulsatile flow by changing the rotating speed of the impellers, the traditional centrifugal pump was rarely used for long-term support of the failing heart. We therefore developed a motor driven pulsatile implantable impeller pump. The pulsatility was achieved by changing the rotating speed via introducing a square waveform voltage into the motor coil. The impeller vane was designed to have both radial and axial curves according to the stream surface and stream lines to reduce the thrombosis and hemolysis. Nine calves weighing 80 to 100 kg were used. With the calves under endotracheal general anesthesia, left posterolateral thoracotomy was performed to connect the inflow tube with the left atrial appendage and to anastomose the outflow tube with the descending aorta. The calves usually awoke and stood up within hours after discontinuation of anesthetics. Within 7 days, continuous monitoring of electrocardiogram, systemic and pulmonary arterial pressures, and central venous pressure were performed to adjust the pump flow to 40% to 50% of the cardiac output. During the survival of 4 to 54 days (mean 16.3 +/- 19.3 days with two calves surviving longer than 1 month), no significant deterioration of liver or renal function was noted. Because of bleeding, hemoglobin reduced from 11.4 +/- 1.8 to 9.0 +/- 1.3 g/dl, and the hematocrit decreased from 34.5 +/- 4.7 to 26.7 +/- 4.6%. No significant changes of free hemoglobin were noted. In our results, the device revealed competent pulsatile function without severe blood damage or organ dysfunction.

Animals↗