Search PubMed⌕ Search

Biomedical subjects

N J Weissman

Publications and source records attributed to N J Weissman.

At least 55 records · Page 3Linked to original sources

Acute hemodynamic changes during carotid artery stenting.

To determine the clinical significance of acute hemodynamic disturbances during stenting in the carotid sinus region, we assessed the relation between intraprocedural changes in heart rate (HR) and blood pressure (BP) and adverse neurologic and cardiac outcomes. Eighteen patients underwent carotid stenting with the Wallstent (Schneider Inc). Suitable candidates had at least 60% diameter stenosis of the carotid artery by angiography. Initial and nadir HR and BP were recorded during the predilatation, stent delivery, and postdilatation periods. Bradycardia was defined as HR < or =60 beats/min and hypotension as systolic BP < or =100 mm Hg. Nineteen Wallstents were successfully deployed in all 19 carotid arteries. Some degree of bradycardia or hypotension occurred in 68% of carotid stent procedures, but administration of vasoactive medications was necessary in only 7 patients (37%) with more persistent hemodynamic disturbances. Hypotension or the need for continuous vasopressor therapy was significantly more common during postdilatation (32%) than in the predilatation period (5%) (p = 0.02). Bradycardia was not reduced by prophylactic atropine. In 1 patient the hemodynamic response to stenting may have contributed to an adverse neurologic and cardiac outcome. Thus, despite frequent fluctuations in HR and BP, most carotid stenting procedures were performed with excellent overall results, even in patients at high risk.

Aged↗

An assessment of heart-valve abnormalities in obese patients taking dexfenfluramine, sustained-release dexfenfluramine, or placebo. Sustained-Release Dexfenfluramine Study Group.

BACKGROUND: The appetite-suppressant drug fenfluramine, usually given in combination with phentermine, has been reported to be associated with cardiac valvular regurgitation. Concern has been raised that the d-enantiomer of fenfluramine, dexfenfluramine, may also cause this problem. We were able to study the question by modifying an ongoing trial comparing dexfenfluramine with regular dexfenfluramine and placebo. METHODS: We modified our randomized, double-blind, placebo-controlled study of dexfenfluramine to include echocardiographic examinations of 1072 overweight patients within a median of one month after the discontinuation of treatment. The patients (approximately 80 percent of whom were women) had been randomly assigned to receive dexfenfluramine (366 patients), investigational sustained-release dexfenfluramine (352 patients), or placebo (354 patients). The average duration of treatment was 71 to 72 days in each of the three groups. Echocardiograms were assessed in a blinded fashion. RESULTS: When all degrees of valvular regurgitation were considered and when the two dexfenfluramine groups were combined, there was a higher prevalence of any degree of aortic regurgitation (17.0 percent vs. 11.8 percent, P=0.03) and any degree of mitral regurgitation (61.4 percent vs. 54.4 percent, P=0.01) in the active-treatment groups than in the placebo group. These differences were primarily due to a higher prevalence of physiologic, trace, or mild regurgitation. Analyses that used the criteria of the Food and Drug Administration for aortic regurgitation of mild or greater severity and mitral regurgitation of moderate or greater severity found no statistically significant difference among the groups (P=0.14 to 0.75). These analyses showed that aortic regurgitation of mild or greater severity occurred in 5.0 percent of the patients in the dexfenfluramine group, 5.8 percent of those in the sustained-release dexfenfluramine group, 5.4 percent of those in the two active-treatment groups combined, and 3.6 percent of those in the placebo group. Mitral regurgitation of moderate or greater severity occurred in 1.7, 1.8, 1.8, and 1.2 percent, respectively. Aortic regurgitation of mild or greater severity, mitral regurgitation of moderate or greater severity, or both occurred in 6.5 percent, 7.3 percent, 6.9 percent, and 4.5 percent, respectively. CONCLUSIONS: The increased prevalence of aortic and mitral regurgitation in patients treated with dexfenfluramine was small, and the degree of regurgitation was usually classified as physiologic, trace, or mild. However, the duration of therapy was short, and whether therapy of longer duration would yield the same or different results is not known.

Adult↗

Kissing stents in the aortic bifurcation.

BACKGROUND: We report the first series of simultaneously delivered stents used to treat stenosis of the aortic bifurcation. Surgical treatment of aortoiliac occlusive disease carries up to a 3% mortality rate. Percutaneous balloon techniques to treat aortic bifurcation stenosis, although safer, are still associated with up to a 9% incidence of dissection, thrombosis, or significant residual stenosis. Kissing stent insertion should decrease the incidence of these complications. METHODS: Twenty patients underwent kissing stent insertion. Suitable candidates included patients with symptoms of lower limb ischemia and significant atherosclerotic lesions in both ostial common iliac arteries (n = 15) or with extremely complex single ostial iliac stenoses (n = 5). Palmaz stents were delivered simultaneously to both limbs of the aortic bifurcation. RESULTS: Kissing stent insertion was successfully performed in all 20 patients without acute complications. Mean percent stenosis decreased from 46.2%+/-24.8% to -6.8%+/-13.3% (P = .0001) in the right iliac artery, 42.3%+/-22.8% to -1.6% +/-18.1% (P = .0001) in the left iliac artery, and 19.1%+/-16.6% to 2.3%+/-16.4% (P= .0008) in the distal aorta. Intermittent claudication symptoms were improved in 18 (95%) of 19 patients with 12 (63%) of 19 patients becoming totally asymptomatic. The strongest predictor of clinical outcome after kissing stent insertion was the preprocedural extent of femoropopliteal disease: 8 (89%) of 9 patients with femoropopliteal narrowing <75% bilaterally became completely asymptomatic at follow-up compared with only 3 (30%) of 10 patients with more severe stenoses (P = .02). CONCLUSIONS: We have demonstrated in 20 patients that stenoses of the aortic bifurcation can be treated effectively with kissing stents with few serious adverse events.

Aged↗

Histopathology of coronary lesions with early loss of minimal luminal diameter after successful percutaneous transluminal coronary angioplasty: is thrombus a significant contributor?

BACKGROUND: Early loss of minimal luminal diameter of >0.3 mm after successful percutaneous transluminal coronary angioplasty (PTCA) is associated with a higher incidence of restenosis. The underlying mechanism of this early loss is unknown and thrombus may be a contributing factor. METHODS: We performed a prospective study using quantitative computerized planimetry on coronary tissue specimens obtained by directional coronary atherectomy of 24 lesions in which early loss occurred 22+/-9 minutes after successful PTCA. RESULTS: Thrombus was present in 9 (37%) of 24 coronary specimens. Segmental areas (mm2) and percentage of total area were distributed as follows: sclerotic tissue, 4.07+/-0.7 mm2 (63%+/-6%); fibrocellular tissue, 0.97+/-0.27 mm2 (16%+/-4%); hypercellular tissue, 0.99+/-0.29 mm2 (12%+/-3%); atheromatous gruel, 0.18+/-0.07 mm2 (3%+/-0.1%); and thrombus, 0.24+/-0.15 mm2 (6%+/-0.4%). There was no difference in the relative early loss index between lesions with or without thrombus (35%+/-7% vs 26%+/-2%, respectively; P= .87). Multiple stepwise regression analysis did not identify any histologic predictors of relative early loss index. CONCLUSION: Histopathologic analysis of coronary lesions with early loss after successful PTCA suggests that thrombus may not play a significant role in this angiographic phenomenon.

Adult↗

Effects of prolonging peak dobutamine dose during stress echocardiography.

OBJECTIVES: This study sought to test whether the physiologic advantage of a prolonged dobutamine stage during stress echocardiography can be effectively combined with a clinically practical infusion protocol. BACKGROUND: Dobutamine has a half-life of 2 min and requires up to 10 min to achieve steady state. Despite these known pharmacodynamics, dobutamine stress echocardiography is routinely performed by advancing doses at 3-min intervals. Canine studies have shown that dobutamine stress echocardiography end points will occur at a lower dose if each stage is prolonged, but these findings have yet to be used in the clinical setting. METHODS: The standard 3-min dobutamine dose stage during stress echocardiography was modified by extending the peak dose (40 micrograms/kg body weight per min) for an additional 2 min. Consecutive patients underwent this modified protocol to test whether the requirement for atropine could be reduced. According to this modified protocol, if a dobutamine stress echocardiographic end point (85% of maximal predicted heart rate, new wall motion abnormalities, hypotension, arrhythmia or intolerable symptoms) was not reached at 3 min of the peak dose, this dose was prolonged for an additional 2 min. If a doubtamine stress echocardiographic end point was still not attained, atropine (up to 1.0 mg intravenously) was administered. RESULTS: The study included 84 patients, 22 of whom (26.2%) achieved a dobutamine stress echocardiographic end point using the standard 3-min stage. Of the 62 patients who did not reach an end point in the initial 3 min of peak dobutamine dose, the additional 2 min of dobutamine increased heart rate (from 99.6 +/- 23.8 to 107.2 +/- 23.2 beats/min, p < 0.01) and allowed 20 patients (32.3%, p < 0.01) to attain an end point. Of the remaining 42 patients, 23 never achieved a stress echocardiographic end point, despite 1.0 mg of atropine. One patient developed supraventricular tachycardia during the additional 2 min of dobutamine, and one developed nonsustained ventricular tachycardia after receiving atropine. CONCLUSIONS: These data demonstrate that a significant number of patients (32%) who do not reach a dobutamine stress echocardiographic end point with the standard protocol can safely attain an end point solely by extending the duration of the peak dose. Adoption of this strategy may reduce the need for supplemental atropine and its potential adverse effects.

Adult↗

Assessing atherosclerotic plaque morphology: comparison of optical coherence tomography and high frequency intravascular ultrasound.

BACKGROUND: OCT can image plaque microstructure at a level of resolution not previously demonstrated with other imaging techniques because it uses infrared light rather than acoustic waves. OBJECTIVES: To compare optical coherence tomography (OCT) and intravascular ultrasound (IVUS) imaging of in vitro atherosclerotic plaques. METHODS: Segments of abdominal aorta were obtained immediately before postmortem examination. Images of 20 sites from five patients were acquired with OCT (operating at an optical wavelength of 1300 nm which was delivered to the sample through an optical fibre) and a 30 MHz ultrasonic transducer. After imaging, the microstructure of the tissue was assessed by routine histological processing. RESULTS: OCT yielded superior structural information in all plaques examined. The mean (SEM) axial resolution of OCT and IVUS imaging was 16 (1) and 110 (7), respectively, as determined by the point spread function from a mirror. Furthermore, the dynamic range of OCT was 109 dB compared with 43 dB for IVUS imaging. CONCLUSIONS: OCT represents a promising new technology for intracoronary imaging because of its high resolution, broad dynamic range, and ability to be delivered through intravascular catheters.

Aorta, Abdominal↗

Factors influencing regional myocardial contractile response to inotropic stimulation. Analysis in humans with stable ischemic heart disease.

BACKGROUND: We hypothesized that the response of a myocardial segment to maximal dobutamine reflects not only maximal blood flow but also tethering, metabolic, and beta-blocker status. METHODS AND RESULTS: Patients with stable ischemic heart disease (n = 27) had positron emission tomographic measurement of blood flow at rest and with adenosine, and echocardiography at rest and with dobutamine. Positron emission tomographic measurement of [18F]fluorodeoxyglucose myocardial distribution also was made. Adenosine blood flow in segments that contracted normally at peak dobutamine was similar to that of segments that became hypokinetic (1.06 +/- 0.72 versus 1.02 +/- 0.77 mL.g-1.min-1). Segments that became akinetic failed to augment blood flow (0.68 +/- 0.30 mL.g-1.min-1). Fluorodeoxyglucose-blood flow mismatch was more common in segments with abnormal wall motion at peak dobutamine (24 of 59, 41%) versus those that contracted normally (63 of 269, 23%; chi 2, 7.40; P < .01). In patients off beta-blockers, segments that contracted normally at peak dobutamine increased blood flow with adenosine (0.70 +/- 0.31 to 0.86 +/- 0.46 mL.g-1.min-1; P < .05), whereas those that became abnormal did not (0.63 +/- 0.24 to 0.65 +/- 0.19 mL.g-1.min-1; P = NS). Segments of patients on beta-blockers that contracted normally at peak dobutamine increased blood flow with adenosine (0.78 +/- 0.31 to 1.10 +/- 0.70 mL.g-1.min-1; P < .05), as did segments that became abnormal (0.74 +/- 0.34 to 1.06 +/- 0.82 mL.g-1.min-1; P = NS). However, segments adjacent to ones with abnormal wall motion at rest had higher frequency of abnormal response at peak dobutamine in groups on (48% versus 16%; chi 2, 14.1; P < .001) and off (51% versus 21%; chi 2, 10.9; P < .01) beta-blockers. CONCLUSIONS: Augmented contraction at maximal dobutamine depends not only on increased myocardial blood flow but also on tethering, metabolic, and beta-blocker status. Furthermore, impaired flow reserve does not preclude a normal response to maximal dobutamine, since blood flow need not increase greatly to meet demand.

Adenosine↗

Determination of aortic valve area in valvular aortic stenosis by direct measurement using intracardiac echocardiography: a comparison with the Gorlin and continuity equations.

OBJECTIVES: This study sought to 1) show that intracardiac echocardiography can allow direct measurement of the aortic valve area, and 2) compare the directly measured aortic valve area from intracardiac echocardiography with the calculated aortic valve area from the Gorlin and continuity equations. BACKGROUND: Intracardiac echocardiography has been used in the descriptive evaluation of the aortic valve; however, direct measurement of the aortic valve area using this technique in a clinical setting has not been documented. Despite their theoretical and practical limitations, the Gorlin and continuity equations remain the current standard methods for determining the aortic valve orifice area. METHODS: Seventeen patients underwent intracardiac echocardiography for direct measurement of the aortic valve area, including four patients studied both before and after valvuloplasty, for a total of 21 studies. Immediately after intracardiac echocardiography, hemodynamic data were obtained from transthoracic echocardiography and cardiac catheterization. RESULTS: Adequate intracardiac echocardiographic images were obtained in 17 (81%) of 21 studies. The average aortic valve area (mean +/- SD) determined by intracardiac echocardiography for the 13 studies in the Gorlin analysis group was 0.59 +/- 0.18 cm2 (range 0.37 to 1.01), and the average aortic valve area determined by the Gorlin equation was 0.62 +/- 0.18 cm2 (range 0.31 to 0.88). The average aortic valve area determined by intracardiac echocardiography for the 17 studies in the continuity analysis group was 0.66 +/- 0.23 cm2 (range 0.37 to 1.01), and that for the continuity equation was 0.62 +/- 0.22 cm2 (range 0.34 to 1.06). There was a significant correlation between the aortic valve area determined by intracardiac echocardiography and the aortic valve area calculated by the Gorlin (r = 0.78, p = 0.002) and continuity equations (r = 0.82, p < 0.0001). CONCLUSIONS: In the clinical setting, intracardiac echocardiography can directly measure the aortic valve area with an accuracy similar to the invasive and noninvasive methods currently used. This study demonstrates a new, quantitative use for intracardiac echocardiographic imaging with many potential clinical applications.

Aged↗

Effect of beta-blockade on dobutamine stress echocardiography.

Dobutamine is an effective pharmacologic stress used in conjunction with echocardiography because of its beta-agonist properties. Concurrent beta-blockade might alter this effectiveness; however, current clinical experience has been variable. The purpose of this study is to determine whether concurrent beta-blockade alters the ability of a dobutamine stress echocardiogram to detect a fixed coronary stenosis by preventing the onset of a wall motion abnormality or by altering the dose at which the wall motion abnormality appears. Paired dobutamine stress tests with and without beta-blockade (esmolol 500 microgram/kg initial bolus, 100 microg/kg/min infusion) were performed in a canine model (n = 8) with a fixed single-vessel coronary stenosis. Heart rate, systolic pressure, proximal left anterior descending coronary flow, myocardial thickening (by sonomicrometry), and left ventricular area change (by epicardial echocardiography) were monitored. Simultaneous beta-blockade resulted in (1) a delayed and diminished increase in hemodynamic parameters (peak heart rate 164.1 +/- 22.3 without beta-blockade vs 110.1 +/- 28.9 beats/min with beta-blockade, p < 0.001, and peak systolic blood pressure 137.9 +/- 26.8 mm Hg without beta-blockade vs 107.3 +/- 15.3 mm Hg with beta-blockade, p = 0.01), (2) an elimination of the physiologic effects of low-dose (5 and 10 microg/kg/min) dobutamine (-0.7 percent +/- 16.7 percent change in myocardial thickening from baseline with beta-blockade, p = NS), and (3) an elimination or alteration in timing of inducible wall motion abnormalities caused by severe coronary artery stenoses (mean termination dose 28.8 +/- 9.9 with beta-blockade vs 15.6 +/- 6.1 microg/kg/min without beta-blocker, p < 0.01). The findings in this canine model suggest that the competitive antagonist markedly attenuates the ability of dobutamine stress echocardiography to detect a significant coronary lesion and may alter its ability to detect viable myocardium at low-dose testing. Further clinical studies to determine the sensitivity of dobutamine stress echocardiography in the presence of beta-blockers and to establish protocol standards are necessary.

Adrenergic beta-Agonists↗

Cardiac allograft vasculopathy in partially inbred miniature swine. I. Time course, pathology, and dependence on immune mechanisms.

To assess the role of the immune system in cardiac allograft vasculopathy in large animals, heterotopic heart transplantation was done between partially inbred miniature swine, animals in which transplantation can be done across defined major histocompatibility barriers in a reproducible fashion. Porcine hearts transplanted into untreated recipients across a class I, class II, or full major histocompatibility mismatch were acutely rejected in 6 to 8 days (n = 4). Hearts transplanted into untreated recipients across minor histocompatibility barriers survived for 21 to 44 days (n = 5) and showed no evidence of cardiac allograft vasculopathy. When recipients were treated with a 12-day course of cyclosporine, hearts transplanted across minor histocompatibility barriers survived 42, 64, and 56 days and did not develop vascular lesions. However, hearts transplanted into cyclosporine-treated recipients across a full major histocompatibility disparity survived 20, 22, and 23 days and all three developed biopsy-proven vasculopathy. In one animal, the progression of intimal proliferation was followed in vivo by intracoronary ultrasonography. The degree of intimal thickening documented by ultrasonography correlated well with the intimal proliferation found on tissue histologic samples. These results are the first to show that in large animals, an immune response stimulated by donor major histocompatibility antigens is involved in the induction of cardiac allograft vasculopathy. In addition, these studies point out the utility of a large-animal model of cardiac allograft vasculopathy in which transplantation across defined major histocompatibility barriers can be done reproducibly and in which accurate determinations of the progression or regression of coronary vascular lesions in individual animals can be accurately assessed in vivo.

Animals↗

Percutaneous transvenous intracardiac ultrasound imaging in dogs: a new approach to monitor left ventricular function.

OBJECTIVE: To evaluate the feasibility and ability of percutaneous transvenous intracardiac echocardiography (ICE) to image the left ventricle (LV) and monitor its function from the right ventricular (RV) cavity. METHODS: A 10 MHz catheter was advanced into the RV from the jugular vein and positioned along the septum at the LV papillary muscle level in five dogs. The catheter was manipulated until a stable catheter position along the septum, which provided on-axis images of LV, was obtained. Different states of LV size and systolic function (n = 80) were created with dobutamine or esmolol, both in the presence and absence of coronary stenoses. LV stroke area (cm2) obtained by ICE was measured at the mid-ventricular level and compared with stroke volume (cm3) obtained simultaneously with a transaortic flow probe. LV end diastolic, end systolic, and stroke areas obtained by ICE were also compared with those obtained by short-axis epicardial echocardiography. RESULTS: In 96% of the stages, short axis images of the LV could be obtained and measured by ICE. LV end diastolic, end systolic, and stroke areas measured by ICE were not significantly different from epicardial echocardiographic values. Stroke area correlated with stroke volume in each dog (mean correlation coefficient 0.79 (SEE 0.19) cm2) (P < 0.001). CONCLUSIONS: Percutaneous intracardiac ultrasound imaging allows monitoring of LV function from the RV with an accuracy comparable to a short-axis epicardial echocardiogram. The present device can be used in closed chest experimental studies. With the development of lower frequency devices, this technique may be valuable for continuous monitoring of LV function in patients in the intensive care unit or operating room.

Animals↗

Optimal stage duration in dobutamine stress echocardiography.

OBJECTIVES: This study attempted to determine the benefit of a 5-min dobutamine stress echocardiographic stage versus a 3-min stage in a canine model. BACKGROUND: Dobutamine stress echocardiography, as currently performed, uses a variety of different protocols. Among the many aspects of dobutamine stress echocardiographic protocols that vary is stage duration. Because dobutamine has specific pharmacodynamics, it is possible that stages of different durations may have different cardiovascular effects. METHODS: Paired dobutamine stress echocardiograms were obtained in 10 open chest instrumented dogs. The stage duration for the initial dobutamine stress echocardiogram was randomly allocated to either 3 or 5 min, and all hemodynamic and echocardiographic variables were allowed to return to baseline before the second dobutamine stress echocardiogram was obtained using the alternative stage duration. At each stage, heart rate, systolic blood pressure, coronary flow, myocardial wall thickness and left ventricular cavity area were recorded. Cavity obliteration, hypotension, ventricular tachycardia or a maximal dose of 40 micrograms/kg body weight per min served as the dobutamine stress echocardiographic end point. RESULTS: At baseline, no difference was detected between the 3- or 5-min protocols for heart rate, systolic blood pressure, rate-pressure product, coronary blood flow, wall thickness or percent area change. Heart rate, systolic blood pressure and coronary flow increased more by the 10-micrograms/kg per min dose with the 5-min protocol than with the 3-min protocol. The dobutamine stress echocardiographic end points were achieved at a lower dobutamine dose (15.0 +/- 4.1 vs. 11.0 +/- 2.1 micrograms/kg per min [mean +/- SD], p = 0.01) with the longer stage duration. CONCLUSIONS: In this canine model, a longer stage produced a greater hemodynamic effect at a lower peak dose. Thus, extending stage duration in clinical dobutamine stress echocardiography may achieve equivalent physiologic stress at lower doses and contribute to the optimization of dobutamine stress echocardiographic protocols.

Animals↗

Effect of hydration on cavity obliteration during dobutamine stress echocardiography.

The purpose of this study was to determine whether it is possible to prevent or delay the onset of midventricular cavity obliteration during a dobutamine stress test with standard hydration. Left ventricular (LV) intracavitary obstruction has been reported as the mechanism for hypotension seen in approximately 20% of patients undergoing dobutamine stress echocardiography. In addition, it has been proposed that administration of a normal saline bolus prior to dobutamine infusion may avert the dynamic ventricular obstruction. We performed a standard graded dobutamine stress echocardiogram before and after fluid loading with 10 ml/kg of normal saline in 10 mongrel dogs. Measurements were made of left atrial pressure, aortic pressure, and the area of the LV cavity at the papillary muscle level throughout each infusion. Although hydration produced an increase in baseline left atrial pressure (5.7 +/- 3.2 to 8.1 +/- 2.7 mmHg, p < 0.01) and systolic blood pressure (128 +/- 18 to 139 +/- 22 mmHg, p = 0.03), there was no significant change in pre-dobutamine heart rate or systolic area. With dobutamine infusion, there was a similar change in heart rate, systolic blood pressure, diastolic area, and systolic area (SA) at each dose of dobutamine regardless of hydration status. In addition, the dose at which cavity obliteration occurred was not altered by hydration (p = NS). Although all dogs developed cavity obliteration (SA < 1.0 cm2) with dobutamine infusion, none experienced hypotension. In this canine model, cavity obliteration does not lead to systemic hypotension and cannot be prevented or delayed by volume loading.

Animals↗