Myocardial infarct size quantification by MR imaging early after coronary artery occlusion in dogs.

The feasibility of using magnetic resonance (MR) imaging to estimate myocardial infarct size was explored in an in vitro model using only the inherent differences in contrast between infarcted and noninfarcted myocardium. Eight dogs underwent coronary occlusion; their hearts were removed 6 hours later. Estimates of T2 for normal and infarcted myocardium were derived from MR images. Infarct size was quantified anatomically using triphenyltetrazolium-chloride (TTC) staining and compared with MR estimates. The T2 values derived from the images clearly discriminated between infarcted (126 +/- 22 msec) and normal myocardium (88 +/- 10 msec, P less than .05), providing images with good contrast between normal and infarcted myocardium. Comparable differences in T2 values were also noted from spectrometric determinations. Estimates of infarct size by MR imaging compared well with TTC estimates (r = 0.98) over a wide range of infarct sizes from 3% to 29% of the left ventricular mass. These results suggest the potential for in vivo quantification of infarct size based on the inherent contrast difference between infarcted and normal myocardium.

Animals↗

Improvements in the clinical utility of calculated T2 images of the human brain.

Magnetic Resonance Imaging (MRI) affords a considerable improvement in image contrast over other methods by virtue of the intrinsic NMR parameters spin density, T1, and T2. However, the clinical utility of routine quantification of these parameters is currently unknown. Calculated T2 images might afford additional disease specific information provided the calculation algorithm generates accurate T2 values. In this study, calculated T2 images of a MnCl2 phantom (spanning a T2 range of interest of 45.7 ms to 346.6 ms at 6 MHz) were generated utilizing a variety of calculation algorithms based upon a data set of 32 sequential spin-echo (SE) images. In general, when utilizing only the earliest sequential SE after the 90 degree pulse for the T2 calculation, the greater the number of SE used in the calculation algorithm, regardless of how they were averaged, the more accurate and less noisy was the calculated image. When only limited numbers of SE were used in the calculation algorithm, accuracy and noise varied with the choice of TE suggesting that there may be optimal timings for TE for a particular T2 range of interest. Forty-two calculated T2 head images of normal subjects, based upon data sets of 16 sequential SE, were evaluated for the T2 values of normal brain. These were compared to T2 images calculated via 7 different algorithms based upon 16 SE data sets from two patients with CNS pathology. An optimal algorithm was identified in which 16 SE Carr-Purcell-Meiboom-Gill (CPMG) were averaged into two images for the T2 calculation. With this algorithm, calculated images could be generated efficiently which were accurate and relatively noise free. The availability of such images maximized whatever disease specificity, and thus clinical utility, T2 information affords.

Brain↗

Nuclear magnetic resonance diagnosis of an anaplastic astrocytoma.

A patient presented with an 8-month history of a progressive left homonymous visual field deficit, left hemiparesis, and a left thalamocortical sensory deficit that was not detectable by repeated conventional neurodiagnostic evaluations. Proton nuclear magnetic resonance (NMR) imaging revealed a right parietal lesion characterized by a prolonged T2 (spin-spin relaxation time). At surgery, the mass proved to be an anaplastic astrocytoma. NMR appears to be more sensitive than x-ray computerized tomography scanning in some patients with malignant gliomas and offers the clinician an additional probe with which to evaluate these patients.

Astrocytoma↗

Nuclear magnetic resonance evaluation of stroke. A preliminary report.

Nine patients who had acute and subacute stroke were examined by nuclear magnetic resonance (NMR) using a 6-MHz Bruker Instruments proton scanner. A modified Carr-Purcell-Meiboom-Gill pulse sequence was used for signal detection. The resultant string of spin-echoes was Fourier transformed into projections that were subsequently back-projected to a series of spin-echo images. From these images, spin density and T2 were calculated for each pixel. The NMR scans revealed stroke in each of the patients, while CT demonstrated only eight of the lesions. T2 was prolonged in all of the ischemic regions and is the most sensitive NMR parameter in detecting stroke. These preliminary results suggest that NMR scanning of patients who have acute stroke may be clinically useful, and that the T2 component of the NMR signal is most important.

Cerebrovascular Disorders↗

Single-step calculation of the MTF from the ERF.

A method is presented whereby the modulation transfer function can be calculated directly from the edge response function without having to find the line spread function as an intermediate step.

Energy Transfer↗

A precise CT phantom alignment procedure.

Two of the AAPM CT performance phantom inserts require precise alignment. We present a method for aligning an insert which makes use of the partial volume effect. We demonstrate that the procedure is sensitive to tilts of less than one degree and, using the slice thickness insert, allows reproducible positioning.

Humans↗

CT quality assurance: computer assisted slice thickness determination.

The precise slice geometry of a CT scanner is an important, albeit tedious to determine, characteristic. A series of computer programs have been developed to analyze the slice thickness insert of the AAPM phantom. Without operator assistance they generate the beam profiles and slice thicknesses at three points in the scan field. A representative analysis is done on an AS&E scanner with slice thickness settings of 2 to 10 mm. The resulting discrepent measured thicknesses, ranging from 3 to 8 mm, indicate the need to perform such slice thickness measurements as part of a regular quality assurance program.

Computers↗

Computer assisted MTF determination in CT.

A series of computer programs have been written to analyze a scan of the AAPM CT performance phantom resolution insert with little operator assistance. A representative analysis is done on a scan from an AS&E scanner as an example. Its point spread function, edge response function and modulation transfer function are presented.

Computers↗

CT alignment probe for the dose profile insert.

One of the most accepted methods of characterizing the dose in computed tomography (CT) is by measuring the dose profile. Thermoluminescent dosimeters (TLD's) arranged in a stack are scanned in a plexiglass phantom. Unfortunately with this system there is no assurance that the scan properly intercepts the stack. Mispositioning will not be apparent until the TLD's are read, entailing at least a 24 h delay before rescanning. We have designed a simple alignment probe that insures that the scan will be centered on the stack to within 1 mm.

Humans↗

An improved method for determining CT image slice thickness.

One of the important characteristics of a computed tomography scanner is the image slice thickness. Most phantoms designed to measure this parameter do so with a ramp or tilted wire. Such a phantom must be precisely aligned to avoid possible significant inaccuracy. We present here a procedure for measuring the image slice thickness using a phantom containing two crossed ramps. The procedure produced consistent and accurate measurements of slice thickness without having to carry out a time consuming alignment procedure.

Humans↗

Accurate T2 NMR images.

We present a method for producing accurate calculated T2 nuclear magnetic resonance (NMR) images. A modified Carr-Purcell-Meiboom-Gill pulse sequence is used to obtain a series of images with progressive T2 dependence. This image series is then analyzed pixel by pixel to generate a T2 and initial signal strength image. Tests performed using four samples of known T2 indicate accuracies of better than 9%.

Image Enhancement↗

Accurate T1 and spin density NMR images.

We present a method for producing accurate calculated T1 and spin density nuclear magnetic resonance images. A modified Carr-Purcell-Meiboom-Gill pulse sequence is used to obtain a series of images containing both T1 and T2 dependence. The image series is first analyzed to remove the T2 dependence. The resulting images are then analyzed, pixel by pixel, to generate an image containing T1 values and an image containing values proportional to spin density (SD). Tests performed on two phantoms containing solutions of various known T1's and H2O/D2O concentrations indicate that the T1 image values are accurate to better than 11% and the relative SD values agree to within one standard deviation.

Humans↗

Solutions of two paramagnetic ions for use in nuclear magnetic resonance phantoms.

The introduction of paramagnetic ions to affect relaxation times has been used in a variety of nuclear magnetic resonance (NMR) applications. All such relaxants used in NMR phantoms to date have consisted of a single paramagnetic ion. The disadvantage of this is that only one relaxation time can be adjusted as desired, either T1 or T2. This study demonstrates that, by properly choosing two paramagnetic ions, it is possible to adjust both T1 and T2 independently over a wide range of values. Specifically, solutions of MnCl2 and NiCl2 were prepared that simultaneously matched target T1 and T2 values to within approximately 6%.

Chlorides↗

Magnetic resonance imaging in multiple sclerosis: results in 32 cases.

A prospective clinical study was performed in 32 patients with multiple sclerosis (MS) to evaluate the sensitivity of lesion detection and accuracy of lesion localization by neurologic examination, delayed enhanced computed tomography (CT) with a double dose of contrast material, and proton magnetic resonance (MR) imaging. After neurologic examination patients were classified by probability of MS (possible, four patients; probable, three patients; and definite, 25 patients) and by disease activity (acute, chronic with acute exacerbation, or chronic progressive). Subsequently they underwent delayed enhanced CT scanning and MR imaging with more than one spin-echo technique. In five of seven patients with possible or probable MS, both MR imaging and delayed enhanced CT were negative. In 25 cases of definite MS, MR imaging detected pathology in 19 (76%) cases, while CT detected lesions in 15 (60%) of 25 cases. In acute lesions (acute or chronic with acute exacerbation), the two techniques were of similar sensitivity (delayed CT was positive in 65% and MR imaging in 60%), while in chronic progressive MS, MR imaging was superior in lesion detection (MR imaging positive in 75%; delayed CT in 25%). While most lesions (55%) were seen in corresponding locations in both studies, neither MR nor delayed CT correlated well with lesion localization by neurologic examination because a large number of asymptomatic lesions were imaged and many symptomatic lesions were undetected.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

NMR evaluation of stroke in the rat.

Cortical stroke was produced in rats by cautery occlusion of the middle cerebral artery distal to the lenticulostriate origins. Brains were removed, and nuclear magnetic resonance (NMR) scans of whole fixed brains and in vitro measurements of small samples were obtained. Brain tissue was then processed for histology. Routine scans used a modified spin-echo technique. Spin-density and T2-dependent scans were also obtained. Infarcts were detectable in 6 hr due to diminution of the spin-echo intensity from T2 prolongation. NMR changes increased gradually over 48 hr and coincided anatomically with evidence from the neuropathologic sections. NMR imaging is a very sensitive method of evaluating acute cerebral infarction in this animal model.

Animals↗