Publications and source records attributed to N G Baldwin.

At least 19 recordsLinked to original sources

Spinal stabilization by using crossed-screw anterior-posterior fixation after multisegmental total spondylectomy for thoracic chondrosarcoma. Case report.

The authors describe the case of a 41-year-old man with high-grade chondrosarcoma who presented with a paraspinous mass extending into three thoracic vertebrae (T10-12). Crossfixed long anterior and posterior instrumentation was placed after three complete spondylectomies (T10-12). This technique augments spinal stability with an outrigger effect by using crossfixators placed between paired dorsal rods, as well as between the anterior and posterior hardware components. This technique may be used as an alternative when multiple vertebrae or all three spinal columns are involved by radioresistant malignant tumors in patients in whom there is a relatively long life expectancy.

Adult↗

Magnetic source imaging and brain surgery: presurgical and intraoperative planning in 26 patients.

OBJECT: The availability of large-array biomagnetometers has led to advances in magnetoencephalography that permit scientists and clinicians to map selected brain functions onto magnetic resonance images. This merging of technologies is termed magnetic source (MS) imaging. The present study was undertaken to assess the role of MS imaging for the guidance of presurgical planning and intraoperative neurosurgical technique used in patients with intracranial mass lesions. METHODS: Twenty-six patients with intracranial mass lesions underwent a medical evaluation consisting of MS imaging, a clinical history, a neurological examination, and assessment with the Karnofsky Performance Scale. Magnetic source imaging was used to locate the somatosensory cortex in 25 patients, the visual cortex in six, and the auditory cortex in four. The distance between the lesion and the functional cortex was determined for each patient. Twenty-one patients underwent a neurosurgical procedure. As a surgical adjunct, a frameless stereotactic navigational system was used in 17 cases and a standard stereotactic apparatus in four cases. Because of the results of their MS imaging examination, two patients were not offered surgery, four underwent a stereotactic biopsy procedure, 10 were treated with a subtotal surgical resection, and seven were treated with complete surgical resection. One patient deteriorated before a procedure could be scheduled and, therefore, was not offered surgery, and two patients were offered surgery but declined. Three patients experienced surgery-related complications. CONCLUSIONS: Magnetic source imaging is an important noninvasive neurodiagnostic tool that provides critical information regarding the spatial relationship of a brain lesion to functional cortex. By providing this information, MS imaging facilitates a minimum-risk management strategy and helps guide operative neurosurgical technique in patients with intracranial mass lesions.

Adult↗

Ex vivo expansion of tumor-draining lymph node cells using compounds which activate intracellular signal transduction. I. Characterization and in vivo anti-tumor activity of glioma-sensitized lymphocytes.

It has been shown that adoptive immunotherapy can be curative for established malignant tumors. The key to this treatment lies in obtaining sufficient numbers of lymphocytes which are sensitized to recognize tumor antigens and carry out immunological reactions to destroy tumor cells. Reported here are the results of experiments to: 1) sensitize lymphocytes to the antigens of rat glioma cells and expand them ex vivo for use in adoptive immunotherapy, 2) characterize the cells of the expanded population, and 3) evaluate antitumor activity in a cohort of rats with well-established intracranial gliomas. Viable RT-2 glioma cells were injected into the hind foot pads of syngeneic Fischer 344 rats. After 10 days, the tumor draining lymph nodes (DLN) were harvested from the injected limbs and mechanically dissociated. The cells of the DLN were then suspended in culture medium supplemented with low dose interleukin-2 (IL-2) and incubated for 18 hours with Bryostatin-1 and ionomycin (Bryo/Io) to stimulate expansion. The cells were next washed to remove the Bryo/Io and resuspended in culture medium and IL-2. Population expansions of 40- to 100-fold were seen after 8 days. Flow cytometric analysis showed these cells to be a nearly pure population of T lymphocytes of the CD3+CD8+ phenotype. Intravenous injection of the ex vivo expanded DLN cells did not significantly improve survival of rats with a seven-day intracerebral RT-2 glioma, although, compared to untreated controls, the tumors of the treated animals were smaller, showed no necrosis, and appeared to be less infiltrative. Furthermore, the treated animals had a pronounced lymphocytic infiltration of their tumors with greater associated degrees of hemorrhagic change and peritumoral edema. When the ex vivo expanded DLN cells were intravenously injected into three-day intracerebral RT-2 glioma models, tumors were almost always eliminated and the animals survived their tumor challenge. We conclude that successful expansion of glioma-sensitized DLN lymphocytes is possible and that adoptive immunotherapy using these cells is capable of effectively limiting the progression of large gliomas, while totally eradicating small ones.

Animals↗

Ex vivo expansion of tumor-draining lymph node cells using compounds which activate intracellular signal transduction. II. Cytokine production and in vivo efficacy of glioma-sensitized lymphocytes.

We have investigated the anti-tumor activity of ex vivo activated and expanded T cells which had been sensitized in vivo to one of two different syngeneic rat glioma cell lines; D74 or RT-2. Rats were sensitized by inoculation of irradiated tumor cells into each hind foot pad. After 10 days, the tumor-draining lymph node (DLN) from each popliteal region was excised and prepared as a single cell suspension. Tumor-DLN lymphocytes were next activated overnight in RPMI-1640 medium containing 10% fetal bovine serum (FBS), Bryostatin-1 (5 nM), ionomycin (1 microM), and 20 U human recombinant interleukin-2 (IL-2) per ml. Culture for seven days in RPMI-1640 supplemented with FBS and IL-2 resulted in approximately 100-fold expansion of the lymphocyte population. Both D74- and RT-2-sensitized T cells constitutively secreted tumor necrosis factor-alpha, and both lymphocyte populations produced comparable amounts of the cytokine when co-cultured with either glioma cell line. Neither D74- and RT-2-sensitized effectors constitutively secreted gamma-interferon (gamma-IFN), but both populations produced gamma-IFN when exposed to either glioma cell line in vitro. D74-sensitized T cells released significantly more gamma-IFN than the RT-2 DLN lymphocytes. In vitro Chromium-release assays indicated that RT-2-sensitized T cells were more cytotoxic for RT-2 targets than for the D74 line and that D74-sensitized effectors were also more cytotoxic for RT-2 targets. To assess in vivo therapeutic efficacy, rats who had been inoculated intradermally with RT-2 cells three days earlier received an intravenous injection of RT-2- or D74-sensitized DLN cells (10(6) cells/gram body weight) expanded after activation with Bryostatin-1 and ionomycin or an equal number of lymphokine-activated killer (LAK) cells. Tumor diameters were measured daily and revealed that injection of glioma-sensitized lymphocytes led to the elimination of tumor while treatment with LAK cells had no therapeutic benefit. These results indicate, that at least for these two glioma lines, gamma-IFN release, rather than in vitro cytotoxicity, was a better predictor for in vivo immunotherapeutic efficacy of the glioma-sensitized, expanded T cells.

Animals↗

Adoptive immunotherapy of malignant glioma using tumor-sensitized T lymphocytes.

Malignant glioma remains one disease for which there is no curative therapy. Clearly there is a need to explore new and innovative approaches for their treatment. In this report, we review our preclinical trial of a new adoptive immunotherapy protocol using cytotoxic T lymphocytes (CTL) which had been sensitized to glioma in vivo and then activated and their number expanded ex vivo using compounds which enhance signal transduction. These glioma-sensitized lymphocytes, when introduced systemically into rats with either an intracerebral or intradermal glioma, eradicated or slowed the progression of their tumor. These results indicate for the first time that a reproducible and sustained eradication of a malignant glioma could be achieved by the adoptive transfer of tumor-sensitized, ex vivo expanded CTL. A Phase I clinical trial is now underway to test the safety and potential efficacy of this immunotherapy in patients with recurrent malignant glioma.

Animals↗

Cervical spondylotic myelopathy: surgical decision making.

Cervical spondylotic myelopathy can produce a variety of clinical signs and symptoms secondary to neural compromise and biomechanical involvement of the spine. The surgical treatment of cervical spondylotic myelopathy remains a controversial issue after many years of study, evolution, and refinement. Several ventral, dorsal, or combined approaches have been defined. The complications associated with ventral approaches and the concerns about kyphosis following dorsal approaches led to the development of a variety of laminoplasty procedures. This paper reviews the biomechanical basis of cervical spondylotic myelopathy and its effect on choosing the appropriate surgical approach.

Journal Article↗

Cervical spondylotic myelopathy treated with corpectomy: technique and results in 44 patients.

Forty-four patients with cervical spondylotic myelopathy who underwent a ventral surgical approach were evaluated with respect to the results of surgery. The neurological status of the patients was categorized according to the modified Japanese Orthopedic Association scale (0-18). Three patients had a functional score of 8, one patient 9, five patients 10, five patients 11, seven patients 12, seven patients 13, seven patients 14, and nine patients had a functional score of 15, preoperatively. Twenty-three patients underwent a one-level corpectomy, 15 patients a two-level corpectomy, and six patients underwent a three-level corpectomy. Forty-one (93.1%) of the 44 patients underwent ventral cervical plate fixation. Complications among the 44 patients included graft- and instrumentation-related complications in seven cases, iliac crest donor-site infection in three cases, and respiratory complications in three cases. The follow-up periods ranged between 7 and 60 months (mean 42.3 months). Overall, the fusion rate was 97.72%. Three patients showed no functional change (6.8%), two patients were worse (4.5%), and 39 patients (88.6%) showed functional improvement in their score between +1 and +6 points (mean 2.16 points). There was no statistically significant difference in the functional improvement score in patients younger or older than 60 years old. The mean improvement in the functional score was found to be +2.857 +/- 1.352, +2.400 +/- 1.454, and +0.5000 +/- 1.871 following one-level corpectomy, two-level, and three-level corpectomies, respectively. There were statistically significant differences in the neurological improvement observed between patients with one-level corpectomy and three-level corpectomy (p < 0.01), as well as between those with two-level and three-level corpectomy (p < 0.05). There was no statistically significant difference in the neurological outcome between patients with one-level and two-level corpectomy (p > 0.05). The results of this study demonstrate a high rate of solid bone fusion and a high rate of functional (neurological) improvement. Five patients underwent reoperation, predominantly for instrumentation failure. The use of instrumentation dictates careful consideration of the risk/benefit ratio associated with its use in each case.

Journal Article↗

A comparison of the pathophysiologic effects of carbon dioxide, nitrous oxide, and helium pneumoperitoneum on intracranial pressure.

BACKGROUND: Previous studies have suggested that diagnostic laparoscopy may be contraindicated in multiple trauma patients with closed head injuries because of the detrimental effects of carbon dioxide (CO2) pneumoperitoneum on intracranial pressure (ICP). In this study we compared the effects of two alternative inflation gases, helium (He) and nitrous oxide (N2O), against the standard agent used in most hospitals, CO2. ICP was monitored in experimental animals both with and without a space occupying intracranial lesion designed to simulate a closed head injury. METHODS: Twenty-four domestic pigs (mean, 30 kg) were divided into four groups (6 CO2, 6 He, 6 N2O, and 6 control animals without insufflation). All animals were monitored for ICP, intraabdominal pressure, mean arterial pressure, end-tidal CO2 (ETCO2), and arterial blood gases. These parameters were measured for 30 minutes prior to introducing a pneumoperitoneum and then for 80 minutes thereafter. The measurements were repeated after artificially elevating the ICP with a balloon placed in the epidural space. RESULTS: The mean ICP increased significantly in all groups during peritoneal insufflation compared with the control group (P < 0.005). The CO2-insufflated animals also showed a significant increase in PaCO2 (P < 0.05) and ETCO2 (P < 0.05), as well as a decrease in pH (P < 0.05). After inflating the epidural balloon the ICP remained significantly higher in animals inflated with CO2 as compared with the He and N2O groups (P < 0.05). CONCLUSIONS: Peritoneal insufflation with He and N2O resulted in a significantly less increase in ICP as compared with CO2. That difference was most likely due to a metabolically mediated increase in cerebral perfusion (PaCO2) in the CO2 group. Further studies need to be conducted to determine the safety and efficacy of using He and N2O as inflation agents prior to attempting diagnostic or therapeutic laparoscopy in patients with potential closed head injuries.

Animals↗

Magnetic resonance imaging for the evaluation of patients with occult cervical spine injury.

Because it is often difficult to diagnose accurately the structurally intact cervical spine after acute trauma, a series of patients was evaluated with magnetic resonance (MR) imaging to assess its efficacy for the evaluation and clearance of the cervical spine in a trauma victim in the early posttrauma period. Ultralow-field MR imaging was used to evaluate 174 posttraumatic patients in whom physical findings indicated the potential for spine injury or minor radiographic findings indicated injury. This series includes only those patients who did not appear to harbor disruption of spinal integrity on the basis of a routine x-ray film. None had clinically obvious injury. Of the 174 patients, 62 (36%) had soft-tissue abnormalities identified by MR imaging, including disc interspace disruption in 27 patients (four with ventral and dorsal ligamentous injury, three with ventral ligamentous injury alone, 18 with dorsal ligamentous injury alone, and two without ventral or dorsal ligamentous injury). Isolated ligamentous injury was observed in 35 patients (eight with ventral and dorsal ligamentous injury, five with ventral ligamentous injury alone, and 22 with dorsal ligamentous injury alone). One patient underwent a surgical fusion procedure, 35 patients (including the one treated surgically) were placed in a cervical collar for at least 1 month, and 27 patients were placed in a thermoplastic Minerva jacket for at least 2 months. All had a satisfactory outcome without evidence of instability. The T2-weighted sagittal images were most useful in defining acute soft-tissue injury; axial images were of minimal assistance. Posttraumatic soft-tissue cervical spine injuries and disc herniations (most likely proexisting the trauma) are more common than expected. A negative MR image should be considered as confirmation of a negative or "cleared" subaxial cervical spine. Diagnostic and patient management algorithms may be appropriately tailored by this information. Thus, MR imaging is useful for early acute posttrauma assessment in a very select group of patients.

Adolescent↗

Anatomy of the thoracic pedicle.

Thoracic pedicle anatomy (interpedicular distance, transverse and sagittal pedicle widths, transverse and sagittal pedicle angles, and the distance from the axis of the pedicle to the axis of the transverse process) was assessed in 11 cadavers of elderly people. The cadaveric spines were extensively dissected to augment the accuracy of the measurements via caliper and goniometer. The results were compared with those of previous studies that assessed pedicle anatomy with computed tomography, direct measurement, and three-dimensional morphometry. Between the studies, significant differences were found in transverse pedicle width and transverse and sagittal pedicle angles. These morphometric differences may reflect either the diversity of the techniques used to measure the pedicle anatomy or sampling variation. This article presents a previously unreported morphometric finding, the rostral-caudal distance from the thoracic pedicle to the midpoint of the base of the transverse process. At T1, the transverse process is 5.45 +/- 1.2 mm rostral to the pedicle. This relationship gradually changes as the thoracic spine is descended, so that at T12, the transverse process is 6.6 +/- 2.4 mm caudal to the pedicle. Crossover consistently occurs at the T6-T7 region. Although the transverse process is a reliable external landmark for the location of the pedicle in the lumbar spine, this relationship in the thoracic spine is variable and only moderately predictable.

Aged↗

Resection of giant invasive pituitary tumors through a transfacial approach: technical case report.

Giant invasive pituitary adenomas are rare tumors that have been reported to extensively involve the cranial base, as well as other intra- and extra-cranial structures, making surgical resection by traditional approaches impossible. We report two cases, each of a giant invasive adenoma involving the entire length of the clivus and adjacent structures that was resected via a transfacial approach with excellent results. Both tumors were in middle-aged men; one was nonsecreting, and the other secreted follicle-stimulating hormone alpha-subunit. Most previously reported giant invasive adenomas have been prolactinomas. Both tumors were resected via a transfacial approach that incorporated an osteoplastic maxillotomy with palatal division and a posterior pharyngeal incision that provided exposure from the suprasellar region to C2. Both of the patients received postoperative radiation and have done very well. Their cosmetic results were excellent. The complications included postoperative meningitis in one patient and a nasal voice in the other. The transfacial approach provides excellent access for this type of extensive midline tumor requiring resection from the suprasellar region down to the foramen magnum.

Adenoma↗

A comparison of fluoroscopy and computed tomography-derived volumetric multiple exposure transmission holography for the guidance of lumbar pedicle screw insertion.

Holographic technology has recently been modified in such a manner that it may now provide clinical use. It allows the visualization of complex structures in three dimensions and permits clinician interaction with the image, which, in turn, provides significant additional geometric and anatomic information. To objectively assess the potential clinical applicability of holography in pedicle screw placement, we studied 11 elderly human cadavers. All of the cadavers, each of which showed significant degenerative disease of the lumbar spine, underwent thin-section computed tomographic scans of the lumbar spine. The acquired digital information was processed, and volumetric multiple exposure transmission holographic images were rendered. Pedicle screws were passed into anatomically acceptable and radiographically visualized L3-L5 pedicles in each cadaver, half using fluoroscopic guidance and half using holographic guidance alone. The accuracy of screw placement was objectively assessed by a three-point grading scale. The total score for the placement of each pedicle screw was determined by both trajectory (location within the pedicle) and accuracy (containment within the vertebral body) of screw tip placement parameters. Three points were possible for each screw placed. Screw placement in the last six cadavers was individually timed for each technique, and fluoroscopic time was also recorded. Each technique was used on 27 pedicles. The total score for fluoroscopic screw placement was 71 (71 of a possible 81; 88%) and for holographic screw placement was 74 (74 of a possible 81; 91%). In the last six cadavers, the screw placement time (per cadaver) was 8 minutes for fluoroscopic placement and 3.6 minutes for holographic placement. Fluoroscopic time averaged 1.9 minutes per cadaver.(ABSTRACT TRUNCATED AT 250 WORDS)

Aged↗

Crossed-screw fixation of the unstable thoracic and lumbar spine.

An ideal spinal construct should immobilize only the unstable spinal segments, and thus only the segments fused. Pedicle fixation techniques have provided operative stabilization with the instrumentation of a minimal number of spinal segments; however, some failures have been observed with pedicle instrumentation. These failures are primarily related to excessive preload forces and limitations caused by the size and orientation of the pedicles. To circumvent these problems, a new technique, the crossed-screw fixation method, was developed and is described in this report. This technique facilitates short-segment spinal fixation and uses a lateral extracavitary approach, which provides generous exposure for spinal decompression and interbody fusion. The technique employs two large transverse vertebral body screws (6.5 to 8.5 mm in diameter) to bear axial loads, and two unilateral pedicle screws (placed on the side of the exposure) to restrict flexion and extension deformation around the transverse screws and to provide three-dimensional deformity correction. The horizontal vertebral body and the pedicle screws are connected to rods and then to each other via rigid crosslinking. The transverse vertebral body screws are unloaded during insertion by placing the construct in a compression mode after the interbody bone graft is placed, thus optimizing the advantage gained by the significant "toe-in" configuration provided and further decreasing the chance for instrumentation failure. The initial results of this technique are reported in a series of 10 consecutively treated patients, in whom correction of the deformity was facilitated. Follow-up examination (average 10.1 months after surgery) demonstrated negligible angulation. Chronic pain was minimal. The crossed-screw fixation technique is biomechanically sound and offers a rapid and safe form of short-segment three-dimensional deformity correction and solid fixation when utilized in conjunction with the lateral extracavitary approach to the unstable thoracic and lumbar spine. This approach also facilitates the secure placement of an interbody bone graft.

Adolescent↗

Failure of a titanium anterior cervical plate implant: microstructural analysis of failure. Case report.

The authors present the case of a failed titanium anterior cervical spine plate. The plate was contoured during implantation. Analysis of the failed implant with electron microscopy showed no metallurgical flaw to have caused the plate fracture. A crack was apparently initiated with the contouring of the plate. It was located at the weakest point in the plate (the position of the intermediate screw hole), and with subsequent stress, it propagated and led to fracture. Techniques for avoiding failure of this type are discussed.

Bone Plates↗

A simple method to ensure proper screw position and plate size selection using the Morscher cervical spine locking plate. Technical note.

The use of bone plate instrumentation with screw fixation has proved to be a useful adjunctive measure in anterior cervical spine fusion surgery. Proper fitting, positioning, and attachment of this instrumentation have been shown to be frequently suboptimal if done without radiographic guidance. The most commonly used method of radiographic assistance for placement of this instrumentation is fluoroscopy. While this gives satisfactory technical results, it is expensive and time-consuming, and exposes the patient and the operating room personnel to ionizing radiation. The authors present a simple technique to ensure screw placement and plate fitting using Kirschner wires and a single lateral radiograph. This technique saves time, reduces exposure to radiation, and has led to satisfactory results in over 20 operative cases.

Bone Plates↗

Fractures of the C-2 vertebral body.

Vertical C-2 body fractures are presented in 15 patients with clinical and imaging correlations that suggest the existence of a variety of mechanisms of injury. In these patients, clinical and imaging correlations were derived by: 1) defining the point of impact by clinical examination; 2) defining the point of impact by soft-tissue changes on cranial magnetic resonance (MR) imaging or computerized tomography (CT); 3) obtaining an accurate history of the mechanism of injury; and 4) spine imaging (x-ray studies, CT, and MR imaging) of the C-2 body fracture and surrounding bone and soft tissue. The cases presented involve the region located between the dens and the pars interarticularis of the axis. Although these fractures are rarely reported, they are not uncommon. An elucidation of their pathological anatomy helps to further the understanding of the mechanistic etiology of upper cervical spine trauma. A spectrum of mechanisms of injury causing upper cervical spine fractures was observed. The type of injury incurred is determined predominantly by the force vector applied during impact and the intrinsic strength and anatomy of C-2 and its surrounding spinal elements. From this clinical experience, two types of vertical C-2 body fractures are defined and presented: coronally oriented (Type 1) and sagittally oriented (Type 2). A third type of C-2 body fracture, the horizontal rostral C-2 fracture (Type 3), is added for completeness; this Type 3 fracture is the previously described Type III odontoid process fracture described by Anderson and D'Alonzo.

Adult↗

Sacral fixation using iliac instrumentation and a variable-angle screw device. Technical note.

Secure fixation of the sacrum is technically challenging. The bone of the dorsal sacral surface is often thin, making hook fixation tenuous. The use of bone screws in the sacral pedicles has gained popularity, but rigidity is often not achieved and screw pullout is common. Solid constructs have been achieved using angled rods to stabilize the ilium, but these methods are technically difficult and time-consuming to perform. A technique is described that achieves rigid sacral fixation by adding a bone screw placed through both cortical surfaces of the ilium. This bone screw is a new type that allows attachment to a rod at variable angles. It permits easy attachment to an appropriately contoured rod, which is affixed to sacral hooks or screws. The resulting configuration of the bone-metal interface creates a tripod for load distribution. Additionally, the splayed geometry of these purchase sites provides a significant biomechanical advantage preventing the instrument from being pulled out. The technique for this fixation method, particularly for patients with complex spinal disorders, is described. Use of this new technique provides significant advantages to the spine surgeon in situations in which substantial sacral fixation integrity is necessary.

Biomechanical Phenomena↗

The sequential hook insertion technique for universal spine instrumentation application. Technical note.

A new technique of universal spine instrumentation insertion for the management of thoracic and lumbar spine instability is presented and the results in 10 patients are described. The technique involves the sequential insertion of Texas Scottish Rite Hospital (TSRH) central-post hooks, followed by hook fixation to the rod; force is then applied with correction of deformity, if needed. This allows for methodical, safe, and rapid instrumentation insertion. The new TSRH central-post hook configuration permits manipulation of the hook/rod relationships to the advantage of the surgeon (and patient) by providing more room for both hook insertion and hook/rod fixation. This technique has reduced operative time, facilitated ease of deformity correction, and provided uniformly acceptable early postsurgical results.

Equipment Design↗