Search PubMed⌕ Search

Biomedical subjects

N Fleischmann

Publications and source records attributed to N Fleischmann.

15 recordsLinked to original sources

Monitoring of a paper mill wastewater treatment plant using UV/VIS spectroscopy.

A submersible UV/VIS spectrometer was used to monitor a paper mill wastewater treatment plant. It utilises the UV/VIS range (200-750 nm) for simultaneous measurement of COD, filtered COD, TSS and nitrate with just a single instrument. The instrument measures in-situ, directly in the process. Paper mill wastewater shows typical and reproducible spectra at various process measuring points. There is a relative maximum at 280 mm due to the absorbance by dissolved organic substances, mainly ligninic acids. Comparison of absorbance spectra distinctly shows the decrease of this peak, indicating biological degradation throughout the treatment process. Summarising, one can say that paper mill wastewater cannot be monitored by a simple UV probe measuring only the absorbance at a single wavelength. The required information can only be gained from the whole spectra. Regarding plant control it is suggested that only the overall spectral information is used. Calibrations to conventional parameters are now merely carried out for purposes of reference-checking.

Calibration↗

On-line monitoring for control of a pilot-scale sequencing batch reactor using a submersible UV/VIS spectrometer.

A submersible UV/VIS spectrometer was used to monitor a pilot-scale sequencing batch reactor (SBR). The instrument utilises the whole UV/VIS range between 200 and 750 nm. With just one single instrument nitrate, organic matter and suspended solids can be measured simultaneously. The spectrometer is installed directly in the reactor, measures in real-time, and is equipped with an auto-cleaning system using pressured air. The paper shows the calibration results for measurements in the SBR tank, time series for typical SBR cycles, and proposes possible ways for optimisation of the operation by using these measurements.

Bioreactors↗

Time-resolved delta spectrometry: a method to define alarm parameters from spectral data.

Alarm parameters are in many ways different from measurements of well defined chemical substances. Being confronted with an increasing number of potentially harmful compounds as well as financial and logistic constraints, new variables (such as alarm parameters) that allow for an integrated assessment or for a first screening can be a solution. To monitor for surrogate or aggregate variables can be a useful strategy to overcome some of the constraints. It must be conceived that this can go along with losses in terms of comparability of results and even in tailor-made variables. Spectral data and their evolution over time are rich in information and compensate for losses due to aggregation and generalisation. Therefore it can be expected that alarm parameters developed from spectral data are transferable, accurate and selective to an extent which is beyond the state-of-the-art. The paper introduces time-resolved delta spectrometry, a method that was developed to generate alarm parameters from spectral data.

Algorithms↗

Spectral in-situ analysis of NO2, NO3, COD, DOC and TSS in the effluent of a WWTP.

An in-situ UV spectrometer was applied to the effluent of a WWTP in Switzerland and calibrated using a multivariate calibration algorithm based on PLS regression. Except for nitrite, the calibration was based on comparative measurements of the effluent in the plant laboratory. Samples made of stock solution added to three different matrices prepared in the EAWAG laboratory were used for the nitrite calibration because the effluent concentrations were always in the range of 0.06-0.26 mg/l. The results show very good precision for nitrite and nitrate. The measuring range for COD and DOC was not completely covered by the measurements, so the meaningfulness of the results is limited. Nevertheless the precision obtained for soluble COD is high enough for most applications at WWTPs. The accuracy of the TSS measurement is unsatisfactory as regards effluent limits since the spectrometer used does not cover the wavelength region up to 700 nm, which gives better signals for TSS calibration due to its strong correlation with turbidity.

Algorithms↗

In situ sensing of volatile organic compounds in groundwater: first field tests of a mid-infrared fiber-optic sensing system.

A prototype mid-infrared sensor system for the determination of volatile organic pollutants in groundwater was developed and tested under real-world conditions. The sensor comprises a portable Fourier transform infrared spectrometer, coupled to the sensor head via mid-infrared transparent silver halide fiber-optic cables. A 10 cm unclad middle section of the 6-m-long fiber is coated with ethylene propylene copolymer in order to enrich the analytes within the penetration depth of the evanescent field protruding from the fiber sensor head. A mixture of tetrachloroethylene, dichlorobenzene, diethyl phthalate, and xylene isomers at concentrations in the low ppm region was investigated qualitatively and quantitatively in an artificial aquifer system filled with Munich gravel. This simulated real-world site at a pilot scale enables in situ studies of the sensor response and spreading of the pollutants injected into the system with controlled groundwater flow. The sensor head was immersed into a monitoring well of the aquifer system at a distance of 1 m downstream of the sample inlet and at a depth of 30 cm. Within one hour, the analytes were clearly identified in the fingerprint region of the IR spectrum (1300 to 700 cm(-1)). The results have been validated by head-space gas chromatography, using samples collected during the field measurement. Five out of six analytes could be discriminated simultaneously; for two of the analytes the quantitative results are in agreement with the reference analysis.

Equipment Design↗

A multivariate calibration procedure for UV/VIS spectrometric quantification of organic matter and nitrate in wastewater.

A submersible UV/VIS spectrometer for in-situ real-time measurements is presented. It utilises the UV/VIS range (200-750 nm) for simultaneous measurement of COD, filtered COD, TSS and nitrate with just a single instrument. A global calibration is provided that is valid for typical municipal wastewater compositions. Usually high correlation coefficients can be achieved using this standard setting. By running a local calibration improvements concerning trueness, precision and long term stability of the results can be achieved. The calibration model is built by means of PLS, various validation procedures and outlier tests to reach both high correlation quality and robustness. This paper describes the UV/VIS spectrometer and the calibration procedure.

Calibration↗

Online sensing of volatile organic compounds in groundwater using mid-infrared fibre optic evanescent wave spectroscopy: a pilot scale test.

A prototype sensing system for in-situ monitoring of volatile organic compounds in contaminated groundwater was tested at a pilot scale plant. The sensor consists of a commercially available Fourier transform infrared spectrometer, connected to a 6 m long infrared transparent silver halide fibre optic cable. A 10 cm long core-only section at the centre of the fibre is mounted on a sensor head and coated with a hydrophobic polymer layer, while the remaining fibre is protected by Teflon tubing and thus not in contact with the surrounding media. The sensor head was immersed into the monitoring wells of the pilot plant testing the sensor system under circumstances close to field conditions and typical for in-situ measurements. The pilot plant consists of a 1 m3 cubic tank filled with gravel. A pump is used to circulate water horizontally through the tank, simulating a natural aquifer. The evolution of the concentration of analytes injected into the system is monitored with time using the developed prototype sensing system. The results are validated by corresponding sampling and analysis with headspace gas chromatography.

Environmental Monitoring↗

Rapid automated detection of nitrification kinetics using respirometry.

There is no doubt that respirometry is a useful measurement principle in the field of wastewater treatment. Although a large variety of methods and case studies have been published, respirometry has become neither a standard tool for control nor for assessment and optimisation of treatment plants. drawback of the conventional method for determining nitrification kinetics is the long experimental time. This disadvantage can be avoided by "turning over" the experiment. Starting with low ammonia concentrations the steep slope of the Monod curve is measured first. The low concentration branch of the Monod curve is also the part where e.g. inhibition can be detected. Therefore the proposed procedure allows us to speed up the measurement of nitrification kinetics and to measure nitrification inhibition on-line.

Ammonia↗

Management of sensible water uses with real-time measurements.

For the protection of bankside wells and a groundwater recharge an early warning system had to be developed. The monitoring network design is based on sensor measurements only. For this purpose a new submersible spectrometer has been successfully tested for multi-parameter measurements directly in the medium. The developed system can easily be upgraded with other new sensors. Only calibration and validation data are supplied by conventional grab sampling and laboratory analysis.. A conventional testfilter improved by on-line monitoring at 5 sampling sites serves as a reference system. The whole system is equipped with remote control and the internet serves as the control centre of the network. All measurement data from all 9 sites are available in real time on the internet.

Automation↗

Type A behavior and coronary atherosclerosis.

OBJECTIVES: To evaluate whether the pathogenesis of type A behavior may involve the premature development of coronary atherosclerosis. BACKGROUND: Type A or coronary-prone behavior is considered a possible risk factor for the development of coronary heart disease. Premature development of coronary atherosclerosis is suspected to play a role. Utilizing electron beam computed tomography, one can accurately determine the degree of coronary artery calcification, which is reflective of coronary atherosclerosis. METHODS: We performed a study of 35 men who had no clinical evidence of coronary heart disease. Twenty exhibited severe type A behavior and 15 exhibited type B behavior. All subjects were given an Electron Beam Computed Tomography scan of their coronary arteries and a treadmill electrocardiogram. RESULTS: Eight of the 20 (40%) type A subjects were found to have coronary calcification compared to none of the type B subjects (P=0.005). The correlation coefficient between type A score and coronary calcium score was 0.39 (P=0.09). CONCLUSIONS: The pathophysiology by which type A behavior increases the risk for coronary heart disease may involve the premature development of coronary atherosclerosis.

Calcinosis↗

Effect of type A behavioral counseling on frequency of episodes of silent myocardial ischemia in coronary patients.

Thirteen of 32 patients with coronary heart disease who also exhibited symptoms and signs of severe time urgency and hostility (the two overt components of type A behavior [TAB]) were found to exhibit multiple episodes of silent myocardial ischemia over a 48-hour period of Holter monitoring as indicated by electrocardiogram ST depressions. Ten of these 13 patients were given 14 months of TAB counseling in an attempt to diminish the intensity of their time urgency and hostility. The remaining three patients served as controls. After counseling, the intensity of the time urgency and hostility of the 10 counseled patients diminished 53% and 59%, respectively, as measured by the videotaped clinical examination. The time urgency and hostility of the three uncounseled control patients did not significantly change. The mean frequency of ischemic episodes in the 10 patients who received TAB counseling significantly declined from an initial 6.6 to 3.1 ischemic episodes per 24 hours. However, the mean frequency of ischemic episodes did not significantly decline in 2 of the 3 uncounseled patients. The third uncounseled patient developed a conduction defect in the 14-month interlude, making an analysis of his repeat 48-hour electrocardiogram for episodes of ST depression impossible.

Behavior Therapy↗

Relation between insecurity and Type A behavior.

This article presents a new Type A Videotaped Clinical Examination scale that measures insecurity. This scale was validated against an existing insecurity measure in a sample of 204 individuals. The results indicated that this new scale is a valid measure of insecurity. The relation between insecurity and type A behavior was examined in a sample of 3013 people. In this large population insecurity showed a strong positive correlation to type A behavior and to each of the two overt behavioral components, time urgency and free-floating hostility.

Aged↗

Causal attributions and coronary heart disease in women.

The relationship between coronary heart-disease endpoints and attributional style in women has been previously unexamined. This study examined the attributions of 73 postmyocardial infarction (MI) women about their heart disease and explored the relationship between attributions and nonfatal coronary recurrence. Women's primary causal attributions included personal behavior (9.6%), blaming others (19.3%), stress (28.8%), luck (12.3%), and family history (13.7%). The largest proportion of recurrences occurred in women attributing their infarcts to marital problems. Of the attributional ratings, ascriptions involving spouses were the only attributions that met entry criteria for logistic regression (p = .019) after controlling for severity of first infarction.

Arousal↗

[Differential anesthetic block].

The concept of differential action of local anaesthetics on nerve fibers of different size is falsified by experiment. The temporal succession of alteration in perception is to be explained by changes at higher levels of integration.

Adult↗