Search PubMed⌕ Search

Biomedical subjects

N Drasdo

Publications and source records attributed to N Drasdo.

At least 55 records · Page 3Linked to original sources

The effect of optical degradation on the contrast sensitivity function measured at the fovea and in the periphery.

Contrast sensitivity functions (CSF's) were measured for a zone of 0.5 degree angular radius at the fovea and for annular zones extending from 0.5 degrees eccentricity to 1 degree, from 1 to 2 degrees and from 2 to 4 degrees. The effect of optical degradation was taken into account by the application of a correction factor determined from the Modulation Transfer Function (MTF). Using the reciprocal of the peak of the CSF [1/SF (max)] as a parameter, the effect of applying the MTF correction on the CSF with eccentricity was determined. The effect of applying an MTF correction is significantly to increase the rate of change of 1/SF (max) with eccentricity. Since it has been reported that hyperacuity is relatively unaffected by optical degradation, it is proposed that the differing effects of optical degradation between grating acuity and hyperacuity may account, at least partially, for the different rates of decline of these thresholds with eccentricity. The implications of this proposal for M-scaling theories and strategies are considered.

Fovea Centralis↗

Pathology of the optic nerve and visual association areas. Information given by the flash and pattern visual evoked potential, and the temporal and spatial contrast sensitivity function.

Spatial and temporal contrast sensitivity functions (CSF) were compared with visual evoked potentials (VEP) in two groups of patients with pathology selectively affecting different parts of the visual pathway. These consisted of 10 patients with a selective delay of the pattern VEP due to demyelination of one optic nerve (unilateral optic neuritis) and 11 patients with a selective delay of the flash VEP due to pathology of the visual association areas (primary presenile dementia, or Alzheimer's disease). The results led to the following conclusions. Comparison of the VEP and CSF results indicated that VEP latency was more closely associated with the temporal CSF than the spatial CSF. Pathology of the visual association areas which selectively increased the latency of the flash P2 component also reduced sensitivity at low and medium temporal frequencies. In demyelination of the optic nerve, a highly significant correlation was found between the delay of the pattern reversal VEP and sensitivity at high temporal frequencies. Comparison of the results in these two types of pathology suggests that the pattern VEP and flash P1 component, the spatial CSF, and temporal CSF at high temporal frequencies are all processed in the geniculostriate pathway. The flash P2 component and temporal CSF at low and medium frequencies were affected differently from the other measures. The possibility that these processes are transmitted by nongeniculate pathways is discussed.

Adult↗

An improved method for using the DTL fibre in electroretinography.

An improved method using DTL fibre for electroretinography is described. The DTL fibre is comfortable and easy to apply. Corneal anaesthesia is unnecessary. The DTL fiber does not interfere with the retinal image and has been used successfully to record both pattern and flash electroretinograms from subjects of all ages.

Electrodes↗

Complementary components and local variations of the pattern electroretinogram.

Pattern electroretinograms have been presumed to arise from a combination of luminance and pattern detection activities. Since the responses at low spatial frequencies are linearly related to contrast and contain negligible pattern specific components, it is proposed that a retinal illuminance response for higher spatial frequencies can be computed from the optical transfer function of the eye. These computed responses are subtracted from pattern electroretinograms to reveal a pattern-specific response with a marked bandpass characteristic. The peak spatial frequency of the bandpass curve declines with increasing peripheral angle. For central vision, the peak amplitude of the pattern-specific response is larger than the retinal illuminance response, but, in the peripheral retina, the two responses are found to be almost equal. The possible origins of these signals are discussed, and it is concluded that the technique provides a method of obtaining separated illuminance and pattern responses from retinal regions having different properties of spatial selectivity.

Electroretinography↗

Effect of epithelial and stromal edema on the light scattering properties of the cornea.

Transparency of the cornea is dependent on normal metabolism. Any disturbance in function, e.g., corneal edema, results in increased light scattering, reducing contrast sensitivity, and increasing glare susceptibility. A psychophysical method was developed to quantify this visual disability and to separate sources of light scatter within the cornea using three conditions: a no glare condition, a 30 degree angular radius glare condition, and a 3.5 degrees angular radius glare condition. Corneal edema was induced (N = 7) and contrast threshold measurements were recorded for 15 min during edema recovery using a clinically available technique. Retinal contrast attenuation was expressed in terms of light scattering factors (LSFs). Results show that the technique devised separates attenuation of retinal image contrast caused by epithelial and stromal edema and provides quantifiable values for normal light scatter and for that due to epithelial and stromal elements.

Adult↗

Perimetric profiles and cortical representation.

The nature of the interaction between spatial summation and M-scaling was investigated by means of the Octopus automated perimeter. It was found that M-scaling of spatial stimulus parameters, alone, did not result in the expected isosensitivity profile. A clinically flat profile was, however, obtained within the central 30 degrees along the horizontal meridian using a large uniform size target (size 3; projected diameter 0.431 degrees). The eccentricities at which presentation of the standard Goldmann targets would result in an isosensitivity profile across the full extent of the visual field were calculated to further illustrate the over-compensation inherent in the current M-scaling equations.

Adult↗

The effect of perimetric stimulation on evoked potential distribution--a theoretical model.

A schematic cortical projection of the human visual field is combined with the concept of dipole planar generators to provide a theoretical model of the scalp distribution of evoked potentials from visual field stimuli. The computations illustrate the importance of gyral surfaces as the principal generators of recorded evoked potentials. Taking several zones of the visual field projection on the striate area as an example, the model is used to produce horizontal profiles of evoked potential amplitude. This indicates the limitation and possibilities of mapping the cortical projections in man and relating these to perimetric findings.

Animals↗

The influence of age on the electroretinogram and visual evoked potential.

Changes in the ERG and VEP across the life span were investigated. The dark adapted and scotopic ERGs both showed a progressive increase in the implicit times of the A and B waves and a reduction in the amplitude of the AB configuration. There was also an increase in the implicit times of the oscillatory potentials of the photopic ERG. The flash and pattern onset-offset VEP both showed changes in waveform with age whilst the waveform of the pattern reversal VEP was constant. The amplitudes of the components of the flash and pattern reversal VEP were very high in the teenage group, but once reduced, were constant from the twenties onwards, showing no further consistent age changes. The latencies of the components of the pattern VEPs showed an increase with age which could be accounted for by the reduction in retinal illuminance due to the decrease in pupil diameter with age. However, the increase in the latency of the flash major positive (P2) component was greater than that expected from the decrease in retinal illuminance alone, suggesting that this is due to neural factors.

Adolescent↗

The influence of age on the spatial and temporal contrast sensitivity function.

A clinical technique for sampling the spatial and temporal CSF at low, intermediate and high frequencies is described. Reductions in contrast sensitivity with age were shown with the highest spatial and temporal frequency stimuli. The reductions can be almost completely accounted for by the reduction of pupil area with age, causing a reduction in retinal illuminance. The results show a significant deterioration in vision with age that is not revealed by standard visual acuity testing.

Adolescent↗

A method of presenting full-field images with minimal distortion.

A method of presenting an image covering the total monocular visual field is described. The geometry of distortion in this full-field image is analysed. Computations demonstrate that local tangential and radial distortion can be minimised by selection of the surface shape, projection and viewing distances. Image luminance distribution can be computed and appears tolerable for most experimental purposes. A unidirectional grating can be presented with the local magnification varying by less than 3% from the central value over the total monocular visual field. For projection of images or gratings with multiple orientations distortion of up to + or - 25% may need to be tolerated. Such systems could have many applications in vision research where unrestricted fields are necessary. A miniature prototype diffusing surface has been generated to produce a full-field grating image with tolerable distortion. An experiment is described to demonstrate the feasibility of plotting a full-field contrast sensitivity function.

Form Perception↗

Electrophysiology of the human visual system.

Progress during the last 60 years has revealed numerous electrical signals arising from many parts of the visual system. These now play an essential part in the detection of many pathological conditions. Further progress in the acquisition and interpretation of these signals is necessary however before they could be justified as part of every routine eye examination. Such significant progress is only likely to occur if the electrophysiological origins of each signal can be more precisely identified and understood. Fundamental research on many aspects is therefore necessary.

Electrodes↗

Sampling systems for visual field assessment and computerised perimetry.

Three successive stages in the representations of the visual image are studied by computations from the best available data. The results are embodied in projections, drawn automatically. These projections are related to the assessment of visual disability and the dimensions of lesions in the retina and visual pathway. Fields can be assessed visually with the aid of graticules or directly during computerised perimetry.

Computers↗

Electroretinography with noncorneal and corneal electrodes.

The noncorneal ERG is essential for certain patients in which corneal recording is contraindicated. A preliminary report is presented investigating ERGs from three noncorneal montages and their correlation with the corneal ERG. Statistical analysis showed that an electrode at the medial canthus combined with medial viewing gave the closest correlation to the corneal ERG. Repeatability was good for all montages. The inner canthus electrode was considered preferable for noncorneal recording because it was less affected by other time-locked activity; it correlated well with the corneal ERG and can be used in conjunction with the electro-oculogram.

Adolescent↗

A pilot study on the use of visual field expanders.

The nature and magnitude of the visual difficulties of five volunteer patients with severely contracted visual field and high visual acuities was investigated by several techniques. These comprised a questionnaire providing a quantitative score of visual impairment, a specially devised visual search task, and an arbitrary method of estimating visual efficiency. Many aspects of visual impairment resulting from contract visual fields were revealed and discussed. Performance scores on the search task indicated that the field expander would probably be useful to a small number of cases for continuous wear, usually as a binocular bioptic system. Other cases might benefit from a clip-on or hand-held device for occasional use. Methods of manufacture and dispensing and difficulty in locating suitable patients were the major limiting factors in this study. The methods of assessment, and the optical system described in this study are worthy of further investigation and development for trial on a larger number of patients.

Eyeglasses↗

Visual field expanders.

Diminishing telescope systems designed to widen the field of view of patients with tunnel vision are described. Theoretical analysis suggests that telescope systems will greatly improve visual search times and diminish the difficulties of such patients. This can be considered quantitatively, and it is suggested that the optimum amount of minifying power can be calculated by applying established formulations on visual efficiency. The inadequacies of previous designs have inhibited development, and further improvements to bioptic systems may be necessary before the final assessment of the clinical value of these devices can be made.

Eyeglasses↗