Search PubMed⌕ Search

Biomedical subjects

N Dellby

Publications and source records attributed to N Dellby.

5 recordsLinked to original sources

Direct sub-angstrom imaging of a crystal lattice.

Despite the use of electrons with wavelengths of just a few picometers, spatial resolution in a transmission electron microscope (TEM) has been limited by spherical aberration to typically around 0.15 nanometer. Individual atomic columns in a crystalline lattice can therefore only be imaged for a few low-order orientations, limiting the range of defects that can be imaged at atomic resolution. The recent development of spherical aberration correctors for transmission electron microscopy allows this limit to be overcome. We present direct images from an aberration-corrected scanning TEM that resolve a lattice in which the atomic columns are separated by less than 0.1 nanometer.

Journal Article↗

Spectroscopic imaging of single atoms within a bulk solid.

The ability to localize, identify, and measure the electronic environment of individual atoms will provide fundamental insights into many issues in materials science, physics, and nanotechnology. We demonstrate, using an aberration-corrected scanning transmission electron microscope, the spectroscopic imaging of single La atoms inside CaTiO3. Dynamical simulations confirm that the spectroscopic information is spatially confined around the scattering atom. Furthermore, we show how the depth of the atom within the crystal may be estimated.

Journal Article↗

Towards sub-0.5 A electron beams.

In the 4 years since the previous meeting in the SALSA series, aberration correction has progressed from a promising concept to a powerful research tool. We summarize the factors that have enabled 100-120kV scanning transmission electron microscopes to achieve sub-A resolution, and to increase the current available in an atom-sized probe by a factor of 10 and more. Once C(s) is corrected, fifth-order spherical aberration (C(5)) and chromatic aberration (C(c)) pose new limits on resolution. We describe a quadrupole/octupole corrector of a new design, which will correct all fifth-order aberrations while introducing less than 0.2mm of additional C(c). Coupled to an optimized STEM column, the new corrector promises to lead to routine sub-A electron probes at 100kV, and to sub-0.5A probes at higher operating voltages.

Journal Article↗

Sub-ångstrom resolution using aberration corrected electron optics.

Following the invention of electron optics during the 1930s, lens aberrations have limited the achievable spatial resolution to about 50 times the wavelength of the imaging electrons. This situation is similar to that faced by Leeuwenhoek in the seventeenth century, whose work to improve the quality of glass lenses led directly to his discovery of the ubiquitous "animalcules" in canal water, the first hints of the cellular basis of life. The electron optical aberration problem was well understood from the start, but more than 60 years elapsed before a practical correction scheme for electron microscopy was demonstrated, and even then the remaining chromatic aberrations still limited the resolution. We report here the implementation of a computer-controlled aberration correction system in a scanning transmission electron microscope, which is less sensitive to chromatic aberration. Using this approach, we achieve an electron probe smaller than 1 A. This performance, about 20 times the electron wavelength at 120 keV energy, allows dynamic imaging of single atoms, clusters of a few atoms, and single atomic layer 'rafts' of atoms coexisting with Au islands on a carbon substrate. This technique should also allow atomic column imaging of semiconductors, for detection of single dopant atoms, using an electron beam with energy below the damage threshold for silicon.

Journal Article↗

Progress in aberration-corrected scanning transmission electron microscopy.

A new corrector of spherical aberration (C(S)) for a dedicated scanning transmission electron microscope (STEM) is described and its results are presented. The corrector uses strong octupoles and increases C(C) by only 0.2 mm relative to the uncorrected microscope. Its overall stability is greatly improved compared to our previous design. It has achieved a point-to-point resolution of 1.23 A in high-angle annular dark field images at 100 kV. It has also increased the current available in a 1.3 A-sized probe by about a factor of ten compared to existing STEMs. Its operation is greatly assisted by newly developed autotuning software which measures all the aberration coefficients up to fifth order in less than one minute. We conclude by discussing the present limits of aberration-corrected STEM, and likely future developments.

Journal Article↗