Search PubMed⌕ Search

Biomedical subjects

N D Charkes

Publications and source records attributed to N D Charkes.

At least 37 records · Page 2Linked to original sources

Comparison of left anterior oblique and geometric mean gastric emptying.

A left anterior oblique image (LAO) and the geometric mean of anterior and posterior counts have both been proposed as methods for acquiring gastric emptying data. Both approaches are used to correct for the changes in attenuation that occur as the depth of radiolabeled solids changes during gastric emptying. These two methods were compared by using a power exponential curve fit to calculate a lag phase, an equilibrium emptying rate, and a half-time for gastric emptying in 20 patients. There were no significant differences (mean +/- 1 s.e.m.) in the measured half-emptying time (115 +/- 10 versus 104 +/- 7 min) (p = 0.08) or rate of gastric emptying (0.015 +/- 0.002 versus 0.015 +/- 0.002 min-1) (p = 0.56) for LAO imaging versus the geometric mean. However, the LAO measurements of the lag phase were significantly higher (69 +/- 7 min) than the geometric mean (53 +/- 6 min) measurements (p = 0.004). This resulted in 4/20 (20%) of patients with normal geometric mean lag phase measurements who would have been reclassified as abnormal using the LAO method.

Female↗

Thallium-201 SPECT increases detectability of thyroid cancer metastases.

Thallium-201- (201Tl) chloride is known to accumulate in metastatic foci of differentiated thyroid carcinoma, but small and deep-seated lesions are generally not detectable by planar imaging. We have evaluated the use of 201Tl-chloride single-photon emission computed tomography (SPECT) in 41 post-thyroidectomy patients with differentiated thyroid carcinoma and one with medullary carcinoma; planar imaging alone was done in eight additional patients (total 50). Of 20 patients with known metastatic disease, planar 201Tl images were positive in 12 (60%) but SPECT revealed an additional 5 (25%) who had metastases (total 85%). SPECT revealed foci as small as 1.0 cm in the neck and 1.5 cm in the lungs, and was particularly useful in detection of disseminated micronodular pulmonary metastases, especially in patients whose scans were negative with diagnostic doses of 131I. Some pitfalls in interpretation of the tomographic reconstructions were found. Thallium-201 SPECT is a marked improvement over planar imaging in the detection of metastases of differentiated thyroid cancer.

Adenocarcinoma↗

The two-component stomach: effects of meal particle size on fundal and antral emptying.

Using a dual-headed gamma camera and a standardized egg test meal labeled with 99mTc-sulfur colloid, the quantitative emptying of the total, proximal and distal stomach in five normal subjects was characterized. The same egg meal was given to the volunteers in 3 different forms: homogenized, and as 2.5 mm and 5.0 mm cubes on 3 separate occasions for a total of 15 studies. For the total stomach emptying, the lag phase and half emptying time (T1/2) obtained using a power exponential model were significantly shorter for the homogenized test meal than for the 2.5 mm and 5.0 mm cubed egg particles; the lag phases were 29 +/- 19 min (mean +/- SD) vs 55 +/- 26 (P less than 0.05) and 64 +/- 24 min (P less than 0.01), the T1/2's were 71 +/- 30 min vs 91 +/- 26 (P less than 0.05) and 104 +/- 30 min (P less than 0.05), respectively. For the proximal stomach, no statistically significant difference was observed among the 3 test meals; the T1/2s for the homogenized, 2.5 mm and 5.0 mm cubed meals were 65 +/- 26 min, 53 +/- 18 min and 64 +/- 20 min, respectively. For the distal stomach, both the peak activity (%) and time to peak activity (min) were significantly higher for the 2.5 mm cubes (43%, 54 min) and the 5.0 mm cubes (38%, 60 min) than for the homogenized eggs (16.4%, 30 min) (P less than 0.01).(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Scintigraphic evaluation of gastric emptying: are radiolabeled solids necessary?

A standard, dual-isotope meal (Tc-99m-egg sandwich and In-111 DTPA in water) was administered to 14 normal volunteers and 37 patients, who had not undergone gastric surgery, to determine if the emptying characteristics of the liquid phase alone could accurately predict delayed solid emptying. Delayed gastric emptying was defined clinically as a solid half-emptying time more than two standard deviations greater than the mean for normal volunteers. Linear regression analysis was performed on the natural logarithm of liquid fractional retention at each time interval to yield a slope and y-intercept for each subject. There was no significant difference (0.6 less than P less than 0.8) between volunteers and patients with normal solid emptying for the liquid slope. In patients who exhibited delayed gastric emptying for solids, the liquid slopes were significantly different from the normal values (P less than .001). There was a high correlation of liquid slope to solid half-emptying time in all patients and volunteers (r = -0.80, P less than .001). Comparison of the liquid slope measurement to solid half-emptying time criteria revealed a sensitivity of 96%, a specificity of 100%, and a predictive value of 100% for the slope test. These results suggest that delayed gastric emptying can be accurately detected with a liquid-solid meal using only a single-liquid label.

Adult↗

Biphasic nature of gastric emptying.

The existence of a lag phase during the gastric emptying of solid foods is controversial. It has been hypothesised that among other early events, the stomach requires a period of time to process solid food to particles small enough to be handled as a liquid. At present no standardised curve fitting techniques exist for the characterisation and quantification of the lag phase or the emptying rate of solids and liquids. We have evaluated the ability of a modified power exponential function to define the emptying parameters of two different solid meals. Dual labelled meals were administered to 24 normal volunteers. The subjects received meals consisting of either Tc-99m in vivo labelled chicken liver or Tc-99m-egg, which have different densities, and In-111-DTPA in water. The emptying curves were biphasic in nature. For solids, this represented an initial delay in emptying or lag phase followed by an equilibrium emptying phase characterised by a constant rate of emptying. The curves were analysed using a modified power exponential function of the form y(t) = 1-(1-e-kt)beta, where y(t) is the fractional meal retention at time t, k is the gastric emptying rate in min-1, and beta is the extrapolated y-intercept from the terminal portion of the curve. The length of the lag phase and half-emptying time increased with solid food density (31 +/- 8 min and 77.6 +/- 11.2 min for egg and 62 +/- 16 min and 94.1 +/- 14.2 min for chicken liver, respectively). After the lag phase, both solids had similar emptying rates, and these rates were identical to those of the liquids. In vitro experiments indicated that the egg meal disintegrated much more rapidly than the chicken liver under mechanical agitation in gastric juice, lending further support to the hypothesis that the initial lag in emptying of solid food is due to the processing of food into particles small enough to pass the pylorus. We conclude that the modified power exponential model permits characterisation of the biphasic nature of gastric emptying allowing for quantification of the lag phase and the rate of emptying for both solids and liquids.

Adult↗

MR imaging in thyroid disorders: correlation of signal intensity with Graves disease activity.

Thirty-six patients with a variety of thyroid disorders and eight healthy subjects were studied with T1- and T2-weighted magnetic resonance (MR) imaging. Solid benign nodules, malignant tumors, and inflammatory conditions were not distinguishable by thyroidal MR signal intensity, but almost all patients with Graves disease had a moderate to marked diffuse increase in signal intensity at both settings. Quantitative evaluation showed that in these patients, the thyroid-muscle signal intensity contrast ratio was linearly related to both the serum thyroxine (T4) level and the 24-hour radioactive iodine uptake. In three patients treated with iodine 131, this contrast ratio rose or fell in parallel with the serum T4 level and 24-hour radioactive iodine uptake. Either parenchymal changes or increased vascularity in Graves disease, or both, could produce these findings. In patients without Graves disease, signal intensity was not correlated with serum T4 levels. These findings suggest that MR signal intensity may reflect the activity of the stimulatory process in Graves disease and may therefore be a useful measure of thyroid function in this disorder, with both diagnostic and prognostic value.

Graves Disease↗

Bone scanning in the adductor insertion avulsion syndrome ("thigh splints").

Shin splints is a defined clinical entity resulting from extreme tension on muscles inserting on the tibia, resulting in periosteal elevation which is detectable by bone scanning. The clinical equivalent in the thigh has been described. We found scintigraphic changes in the femurs of seven short, female, basic trainees at the Fort Dix Army base, most of whom were referred for stress fractures elsewhere in the lower extremities. The scan findings were generally noted in the upper or mid femurs, always involved the anteromedial cortex, and were bilateral in five of the seven subjects. The abnormalities were linear and suggested periosteal elevation, and did not have the typical appearance of stress fracture. Since the findings correspond to the insertion of one or more adductor muscle groups, the descriptive term "adductor insertion avulsion syndrome" or "thigh splints" is proposed for this entity.

Adolescent↗

Mathematical basis for the measurement of absolute and fractional cardiac output with diffusible tracers by compartmental analysis methods.

Using compartmental analysis methods, a mathematical basis is given for the measurement of absolute and fractional cardiac output with diffusible tracers. Cardiac output is shown to be the product of the blood volume and the sum of the rate constants of tracer egress from blood, modified by a factor reflecting transcapillary diffusibility, the transfer fraction. The return of tracer to the blood and distant (intracellular) events are shown to play no role in the solution. Fractional cardiac output is the ratio of the rate constant of tracer egress from blood to an organ, divided by the sum of the egress constants from blood. Predominantly extracellular ions such as sodium or bromide are best suited for this technique, although theoretically any diffusible tracer whose compartmental model can be solved may be used. It is shown that fractional cardiac output is independent of the transfer fraction, and therefore can be measured accurately by tracers which are not freely diffusible.

Animals↗

Multiple scintigraphic findings in a patient with a primary myocardial sarcoma.

Primary myocardial sarcomas are rare. We report the scintigraphic findings observed with TI-201, Ga-67, Tc-99m pyrophosphate, and Tc-99m pertechnetate labeled red cell gated cardiac imaging in a patient with this tumor. We found that thallium and gated blood pool imaging can be used both in the diagnosis of these tumors and the assessment of the effects of chemotherapy on the tumor and normal myocardium. The thallium study was particularly helpful in identifying the malignant nature of the tumor by showing extensive infiltration into surrounding areas.

Adult↗

Studies in skeletal tracer kinetics. V: Computer-simulated Tc-99m (Sn)MDP bone-scan changes in some systemic disorders: concise communication.

Using compartmental analysis techniques, we modeled the biodistribution of Tc-99m(Sn)methylene diphosphonate in humans on a computer, and by selectively perturbing appropriate rate constants, we simulated changes in contrast between bone and soft tissue in a number of systemic disorders. The model predicts low contrast in patients with moderate to marked edema, obesity, congestive heart failure or decreased cardiac output states and high contrast with as little as 25% increase in bone avidity for the tracer. In acute renal failure without fluid-volume imbalance, image contrast should be normal. The model predicts greater contrast shortly after injection in patients with increased cardiac output, skeletal blood flow, or bone avidity; images made at these times would be indistinguishable. These simulations are in keeping with reports in the literature of bone images and bone-to-soft tissue ratios in many of these conditions, suggesting that modeling studies could play an important role image interpretation.

Acute Kidney Injury↗

Evidence for splenic sequestration of in vivo-labeled erythrocytes.

Some of the erythrocytes labeled using an in vivo technique are sequestered by the spleen and thus lost from the circulation. Allowance for this loss must be made if calculations regarding relative changes in ventricular volumes are being made over extensive periods of time.

Cardiac Volume↗

Skeletal blood flow: implications for bone-scan interpretation.

The dispersion of the skeleton throughout the body and its complex vascular anatomy require indirect methods for the measurement of skeletal blood flow. The results of one such method, compartmental analysis of skeletal tracer kinetics, are presented. The assumptions underlying the models were tested in animals and found to be in agreement with experimental observations. Based upon the models and the experimental results, inferences concerning bone-scan interpretation can be drawn: decreased cardiac output produces low-contrast ("technically poor") scans; decreased skeletal flow produces "photon-deficient" lesions; increase of cardiac output or of generalized systemic blood flow is undetectable 1--2 hr after dose; increased local skeletal blood flow results from disturbance of the bone microvasculature and can occur from neurologic (sympatholytic) disorders or in association with focal abnormalities that also incite the formation of reactive bone (e.g., metastasis, fracture, etc.). Mathematical solutions of tracer kinetic data thus become relevant to bone-scan interpretation.

Animals↗