Doppler color flow mapping in the evaluation of prosthetic mitral and aortic valve function.

Doppler color flow mapping and color-guided conventional Doppler studies were performed on 119 patients with 126 prosthetic valves (mitral alone in 60, aortic alone in 52 and both mitral and aortic in 7 patients) within 2 weeks of the catheterization study or surgery, or both. The mean pressure gradients derived by color-guided continuous wave Doppler ultrasound correlated well with those obtained at catheterization for both the tissue and mechanical mitral and aortic prostheses (r = 0.85 to 0.87). For the effective prosthetic orifice areas, better correlation with catheterization results were obtained with the tissue mitral (r = 0.94) and tissue aortic (r = 0.87) prostheses than with the mechanical mitral (r = 0.79) and mechanical aortic (r = 0.76) prostheses. The maximal width of the color flow signals at their origin from the tissue mitral prostheses also correlated well with the effective prosthetic orifice area at catheterization (r = 0.81). Doppler color flow mapping identified prosthetic valvular regurgitation with a sensitivity and specificity of 89% and 100%, respectively, for the mitral and 92% and 83% for the aortic prostheses. There was complete agreement between the Doppler color flow mapping and angiographic grading of the severity of prosthetic valvular regurgitation in 90% of mitral and 73.5% of the aortic regurgitant prostheses with under- or overestimation by greater than 1 grade in only two cases. Valvular and paravalvular regurgitation was correctly categorized by Doppler color flow mapping in relation to the surgical findings in 94% of the mitral and 80.5% of the aortic prostheses.

Adult↗

Reproducibility of two-dimensional exercise echocardiography.

To determine the reproducibility of two-dimensional exercise echocardiography, duplicate studies were performed on the same patients a median of 14 days apart. Because measurements are operator-dependent, interobserver variability was calculated for two experienced readers who interpreted the findings independently in a blinded manner. A high degree of interobserver agreement was found in evaluation of both ejection fraction measurements and wall motion abnormalities. Readings for ejection fraction immediately after exercise taken on different days could be estimated within 4% of the values measured in the first test; similarly measured wall motion score index was within 6% of that in the first test. Ejection fractions and wall motion scores were highly correlated between tests 1 and 2. The correlation coefficients between tests 1 and 2 were 0.92 for both the pre- and postexercise ejection fractions and 0.98 for both the pre- and postexercise wall motion scores. Quantitative two-dimensional echocardiography immediately after exercise is highly reproducible, providing a valuable tool for assessing serial changes in left ventricular function.

Adult↗

Color-guided Doppler echocardiographic assessment of aortic valve stenosis.

The severity of valvular aortic stenosis was assessed by Doppler color flow mapping in 100 consecutive patients who underwent successful cardiac catheterization within 2 weeks of the Doppler study. The maximal width of the aortic stenosis jet seen in 61 of these patients (Group A) was measured at the aortic valve. Color-guided continuous wave Doppler examination was used to measure the mean transaortic pressure gradient, and the aortic valve area was estimated using the simplified continuity equation. The aortic stenosis jet was not seen in 39 patients (Group B), and the mean pressure gradient and aortic valve area in these patients were assessed by conventional Doppler echocardiography alone. The mean pressure gradient obtained by continuous wave Doppler study and cardiac catheterization in the 61 Group A patients correlated well (r = 0.90); the correlation was lower in the 39 Group B patients (r = 0.70). The overall correlation for the combined Groups A and B was good (r = 0.82). The aortic valve area estimated by continuous wave Doppler study and cardiac catheterization in 54 Group A patients correlated well (r = 0.92); the correlation in 22 Group B patients was lower (r = 0.71). The correlation for all 76 patients (Groups A and B) was good (r = 0.80). The maximal aortic stenosis jet width also correlated well with the aortic valve area estimated at catheterization in 54 patients (r = 0.90). Group C represented an additional 14 patients in whom the left ventricle could not be entered during cardiac catheterization.(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent↗

The value of two-dimensional echocardiography and pulsed Doppler technique in facilitating percutaneous catheterization of the subclavian vein.

We have found combined two-dimensional echocardiographic imaging and range-gated pulsed Doppler flow mapping to be very useful and accurate in identifying the location and course of the subclavian vein. It can be efficiently utilized to minimize the incidence of iatrogenic complications during percutaneous central venous catheterization. This is particularly relevant in patients who are predisposed to a high risk of complications from the procedure.

Catheterization, Central Venous↗

Color Doppler assessment of mitral regurgitation induced by supine exercise in patients with coronary artery disease.

Development of mitral regurgitation (MR) during acute myocardial ischemia is a well known occurrence. To assess the feasibility and clinical utility of detecting MR during exercise testing, color Doppler examinations were performed in 22 patients with angiographically proved coronary artery disease (CAD) and in 17 normal subjects before, during and after graded supine bicycle exercise. Not only was MR visualized using color Doppler during dynamic testing, but it was also slightly more sensitive (59% vs 54%) and specific (100% vs 88%) than the electrocardiographic response in identifying patients with CAD. When the appearance of MR or diagnostic electrocardiographic changes or both were used to identify patients with CAD, the sensitivity of exercise tolerance testing increased to 82%, although the specificity was 88%. In addition, exercise-induced MR was observed to be as sensitive and specific as exercise-induced wall motion abnormalities. Combining exercise-induced MR with wall motion abnormalities also increased the sensitivity to 82%, with the specificity remaining at 100%. With use of exercise-induced MR, wall motion abnormalities or electrocardiographic changes, the sensitivity and specificity of the exercise test in diagnosing CAD was 91% and 88%, respectively. The degree of MR as estimated by maximal area of regurgitation signals, as well as by its ratio to left atrial area, did not correlate with extent of CAD. However, the presence of exercise-induced MR suggested an increased likelihood of 3-vessel CAD because it was found in 9 of 11 patients with 3-vessel CAD, compared with 2 of 5 patients with 2-vessel and 2 of 6 patients with 1-vessel CAD.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Evaluation of aortic insufficiency by Doppler color flow mapping.

The color Doppler echocardiographic studies and aortic angiograms of all patients who had these procedures performed within 2 weeks of each other between October 1984 and August 1985 were reviewed to determine whether any parameters of the regurgitant jet visualized by color Doppler study predicted the severity of aortic insufficiency as assessed by angiographic grading. Patients with an aortic valve prosthesis were excluded. Twenty-nine patients had aortic insufficiency and had adequate color Doppler studies for analysis. The mean time between color Doppler examination and angiography was 2.3 days (range 0 to 12). The maximal length and area of the regurgitant jet were poorly predictive of the angiographic grade of aortic insufficiency. The short-axis area of the regurgitant jet from the parasternal short-axis view at the level of the high left ventricular outflow tract relative to the short-axis area of the left ventricular outflow tract at the same location best predicted angiographic grade, correctly classifying 23 of 24 patients. However, the jet could be seen from this view in only 24 of the 29 patients. The height of the regurgitant jet relative to left ventricular outflow tract height measured from the parasternal long-axis view just beneath the aortic valve correctly classified 23 of the 29 patients. Mitral stenosis or valve prosthesis, which was present in 10 patients, did not interfere with the diagnosis or quantitation of aortic insufficiency by these methods.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Diagnosis of double aortic arch by cross sectional echocardiography with Doppler colour flow mapping.

A case of double aortic arch in a 15 month old boy was diagnosed by cross sectional echocardiography supplemented by Doppler colour flow mapping. These examinations showed two very large vessels communicating with the aorta; the demonstration of anterograde flow in one vessel and retrograde flow in the other enabled a definite diagnosis of Edwards type IA double aortic arch to be made.

Aorta, Thoracic↗

Color Doppler assessment of mitral regurgitation with orthogonal planes.

We evaluated 147 patients with adequate color Doppler and angiographic studies for mitral regurgitation. Sixty-five patients had no mitral regurgitation by both color Doppler and angiography and 82 patients had mitral regurgitation by both techniques. Thus the sensitivity and specificity of color Doppler for the detection of mitral regurgitation was 100%. Three two-dimensional echocardiographic planes (parasternal long and short axis, apical four-chamber view) were used to analyze variables of the mitral regurgitant jet signals in the left atrium. The best correlation with angiography was obtained when the regurgitant jet area (RJA) (maximum or average from three planes) expressed as a percentage of the left atrial area (LAA) obtained in the same plane as the maximum regurgitant area was considered. The maximum RJA/LAA was under 20% in 34 of 36 patients with angiographic grade I mitral regurgitation, between 20% and 40% in 17 of 18 patients with grade II mitral regurgitation, and over 40% in 26 of 28 patients with severe mitral regurgitation. Maximum RJA/LAA also correlated with angiographic regurgitant fractions (r = .78) obtained in 21 of 40 patients in normal sinus rhythm and with no evidence of associated aortic regurgitation. Other variables of the regurgitant jet such as maximal linear and transverse dimensions, maximal area, or maximal area expressed as a percentage of the LAA in one or two planes correlated less well with angiography. Color Doppler is a useful noninvasive technique that is not only highly sensitive and specific in the identification of mitral regurgitation but also provides accurate estimation of its severity.

Adolescent↗

Color Doppler evaluation of aortic dissection.

Color Doppler studies were performed in 16 adult patients with proven DeBakey type I and III aortic dissection. Simultaneous opacification of both aortic lumina with oppositely directed flow was noted by color Doppler in at least one aortic segment in 14 of 16 patients (12 type I, two type III). In two patients (one type I, one type III), flow was seen in one lumen only, with clot demonstrated in the other lumen in one of them. Of 12 patients in whom communication between two aortic dissection channels was shown by angiography/surgery, color Doppler correctly identified them in nine patients (four ascending aorta, two aortic arch, and three descending aorta), either by direct visualization of flow moving from one lumen into the other (six patients) or indirectly by analyzing differences in timing of opacification of the two lumina and flow direction (three patients). Also, color Doppler correctly diagnosed aortic regurgitation as severe (aortic regurgitation jet occupying more than 75% of left ventricular outflow) in three patients and moderate in four patients. Color Doppler provides comprehensive evaluation of flow dynamics in aortic dissection.

Adult↗

Calibration of color Doppler flow mapping during extreme hemodynamic conditions in vitro: a foundation for a reliable quantitative grading system for aortic incompetence.

If color Doppler imaging is to continue to evolve into a reliable clinical method to noninvasively evaluate regurgitant lesions, then its grading methods must be quantitated and calibrated under extreme hemodynamic conditions. A left heart pulse duplicator was used to provide a completely controllable system to study aortic incompetence jet morphologies as a function of hemodynamic extremes. The system was first used to calibrate the limits of resolution of color Doppler imaging. Next, to define which jet features reliably predict the defect size or the regurgitant fraction and which are primarily influenced by instantaneous hemodynamic variables, we measured the jets' maximal length, width, proximal width, and temporal pattern of color variance during independent variations in the heart rate, cardiac output, and pressure gradient across the incompetent valve. The proximal jet width (immediately below the valve plane) was the only reliable independent predictor of both the defect size and the regurgitant fraction. Jet depth accurately predicted peak velocity (quantitated by laser Doppler velocimetry); it reliably predicted the severity of incompetence only at a known pressure gradient across the valve. Large defects (5 mm) produced jets with maximal color variance in early diastole, whereas small defects produced pandiastolic variance.