Search PubMed⌕ Search

Biomedical subjects

N Bom

Publications and source records attributed to N Bom.

119 records · Page 7Linked to original sources

The time-distance recorder as a means of improving the accuracy of fetal blood flow measurements.

The influence of pulsatile diameter changes on calculation of volume flow has been studied. In vitro studies and an animal study were carried out with a real-time imaging and pulsed Doppler velocity measurement system. For precise pulsatile diameter information a wall motion tracking device was incorporated. Whereas in vitro a high degree of accuracy was found for the measurements of volume flow, this could not be substantiated in the descending aorta of the fetal lamb, in which Doppler volume flow differed between -7.5 and 17% from magnetic volume flow. In a clinical study the relative influence of various diameter approximations on calculated fetal aortic volume flow was assessed in 16 normal third trimester pregnancies. Depending on the selected diameter approximation method it appeared that differences from 19% underestimation to 9% overestimation in calculated volume flow could be obtained when reference was made to volume flow derived from diameter and velocity information.

Animals↗

Multiplane transesophageal echocardiography: latest evolution in an imaging revolution.

Multiplane imaging with a rotating phased-array transducer from within the esophagus represents the latest development in transesophageal cardiac ultrasound. Transverse, longitudinal, and all possible intermediate oblique planes are easily obtained from the same transducer with minimal probe manipulation. Three-dimensional conceptualization of complex structures and pathologic conditions is facilitated. The major advantages are a simplified examination procedure and much less patient discomfort than monoplane and biplane probe imaging.

Adult↗

Intraoperative epicardial echocardiography: early experience with a newly developed small surgical transducer.

To test the feasibility of performing intraoperative echocardiography with a specially designed epicardial transducer, 20 adult patients were studied. All patients were undergoing coronary bypass surgery and had structurally normal intracardiac anatomy. The surgical transducer has 48 elements and a size at the tip of 10 x 12 x 5 mm. The scan plane has been set at 90 degrees to the cable axis to allow scanning from lateral positions. The terminal 10 cm of the cable has been reinforced to act as a malleable and steerable handle. Good quality images were obtained with the new transducer, and many different imaging planes were identified compared to imaging with the standard transducers. These include the right ventricular apex, the right and left lateral aspects of the heart, the aortic arch, and the pulmonary artery and its branches. The limitation of the probe was the difficulty in obtaining left ventricular apical views because of ventricular arrhythmias sustained when the transducer was placed between the left ventricular apex and the diaphragm. We conclude that this new transducer has a promising future in the application of intraoperative epicardial echocardiography.

Adult↗

The value of transesophageal echocardiography in children with congenital heart disease.

With the use of dedicated pediatric single-plane probes, transesophageal echocardiography was performed prospectively in 102 children to determine the potential value of this new technique in the diagnosis (40 patients) and the follow-up of congenital heart disease (29 patients) and as a monitoring technique during the perioperative period or interventional cardiac catheterization (33 patients). The findings were correlated with precordial studies (102 patients), cardiac catheterization (82 patients), epicardial ultrasound findings (18 patients), or surgical inspection (34 patients). The age at investigation ranged from 2.5 months to 14.9 years (mean age, 5.2 years); weight ranged from 3.7 to 52 kg (mean weight, 19.1 kg). Additional information was obtained in 49 patients (48.4%) and was relevant for patient management in 21 patients (20.6%). Major areas of improved diagnostic insight included the following: (1) systemic and pulmonary venous return, (2) atrial morphology, (3) atrioventricular junction abnormalities, (4) left ventricular outflow tract disease, (5) atrial baffle function, and (6) the Fontan circulation. Inherent limitations were as follows: (1) the semiinvasive character of the procedure, (2) the need for heavy sedation or general anesthesia, and (3) the limited imaging planes provided. Transesophageal echocardiography in children can provide important additional diagnostic information on a wide spectrum of congenital heart lesions. The technique would appear to be a highly valuable adjunct to the diagnostic armentarium of the pediatric cardiologist.

Adolescent↗

Detection and characterization of vascular lesions by intravascular ultrasound: an in vitro study correlated with histology.

High-frequency intravascular ultrasound (30 and 40 MHz) was applied to study 112 human vascular specimens. The ultrasound images were compared with histologic cross-sections. In 44 out of 58 of the histologically classified muscular arteries, a hypoechoic middle layer was seen in the vessel wall, giving it a three-layered appearance. In 10 arteries, fibrous degeneration of the muscular media resulted in a homogeneous appearance of the vessel walls, whereas atherosclerotic plaque precluded the visualization of the arterial media in four of the arteries. A three-layered appearance was seen in seven of nine histologically classified transitional arteries, and a homogeneous arterial wall was seen in two of the nine. None of the 33 elastic arteries, veins, venous bypass, and Goretex conduits showed a hypoechoic medial layer. Histologically proved fibrous intimal thickening was echographically detected in 32 of 48 specimens (67%). It was noted that these intimal lesions were easier to detect with 40 MHz than with 30 MHz transducers. Hypoechoic areas of lipid deposition were detected in 32 of 36 specimens (89%) and could be distinguished from fibrous plaques. Histologically evident calcium deposits were detected with intravascular ultrasound in 35 of 36 specimens (97%). Measurement of plaque area was only possible in cross sections with a three-layered appearance. Quantitative analysis showed a significantly larger lumen area measured from ultrasonic images (26.3 +/- 21.3 mm2) than from histologic cross-sections (21.8 +/- 16.6 mm2, p less than 0.001), probably because of tissue shrinkage during processing for histology. A significant correlation (r = 0.96, p less than 0.001) between ultrasonic and histologic measurements of lumen areas was observed, with and a negligible interobserver and intraobserver variability. Plaque area and medial thickness correlated well with histology (r = 0.87, p less than 0.001 and r = 0.93, p less than 0.001, respectively). It appears from this in vitro study that intravascular ultrasound is an accurate technique for detection and characterization of atherosclerotic lesions. Vessel lumen area can be measured in most instances, whereas plaque area and medial thickness can only be reliably assessed in muscular arteries in which the hypoechoic media serves as a reference, and shadowing by calcium or attenuation by fibrous plaque components is absent.

Adolescent↗

Reference ranges of left ventricular cross-sectional echocardiographic measurements in adult men.

Reference ranges for left ventricle cross-sectional echocardiographic measurements were determined in 67 healthy Dutch men. Age, weight, height, and heart rate were used as the determinants. The images were made with the apical long-axis view, and the calculations were done with the area-length method. The end-diastolic volume, end-systolic volume, stroke volume, and ejection fraction were measured for six consecutive cardiac cycles in every subject and were averaged. Data were analyzed by means of both simple linear regression and multiple linear regression after logarithmic transformation of all measurements. Weight proved to be the best predictor of the echocardiographic end-diastolic volume, end-systolic volume, and stroke volume. The left ventricular ejection fraction could be regarded as independent of the determinants studied. Nomograms of the 5th, 50th and 95th percentile limits were made of the echocardiographic parameters versus weight.

Adult↗