Microwave ablation using a spiral antenna design in a porcine thigh muscle preparation: in vivo assessment of temperature profile and lesion geometry.

INTRODUCTION: Theoretical studies have suggested that microwave energy can increase the depth of heating compared with radiofrequency energy. A spiral microwave antenna design may have advantages over previous designs using smaller designs because the resulting power deposition pattern is considerably larger than the catheter diameter. We tested the efficacy of a spiral antenna using microwave energy in a porcine thigh muscle preparation. METHODS AND RESULTS: In five anesthetized pigs, the thigh muscle was exposed and bathed in heparinized bovine blood (36 degrees to 37 degrees C). A helical microwave catheter with a fiberoptic thermometer attached to the distal end was positioned perpendicular to the thigh muscle. The antenna-tissue interface and tissue temperatures at depths of 3.0 and 6.0 mm were measured. A 915-MHz microwave generator delivered energy at one of three power outputs (50, 100, or 150 W) for 60 seconds. Seventy lesions were created: 50 W (n = 23), 100 W (n = 24), and 150 W (n = 23). The mean depths at 50, 100, and 150 W were 4.3 +/- 1.8 mm, 7.2 +/- 1.7 mm, and 9.4 +/- 0.9 mm, respectively. Lesion depth (R = 0.96, P = 0.05), maximum surface dimension (R = 0.99, P = 0.06), and volume (R = 0.99, P = 0.04) were closely correlated to the power applied. CONCLUSION: Power is an important determinant of lesion size using a spiral microwave antenna. A novel, spiral microwave antenna design can create lesions of significant depth that may be applicable for the ablative therapy of ventricular tachycardia.

Animals↗

Safety and efficacy of a steerable temperature monitoring microwave catheter system for ventricular myocardial ablation.

INTRODUCTION: Radiofrequency current delivered during cardiac ablation is limited by a rise in impedance secondary to coagulum formation on the ablation electrode. Microwave antennas continue to deliver energy despite the presence of coagulum; thus, temperature control of the ablation electrode may be even more important for microwave than for radiofrequency ablations to avoid thromboembolic risks. The purpose of this study was to test the safety and efficacy of an ablation system utilizing a feedback control system to maintain a fixed target temperature for creating lesions with multiple applications of microwave energy. METHODS AND RESULTS: Microwave ablation was assessed using an 8.5-French catheter at 2 to 4 sites in 11 dogs. Microwave energy delivery was performed for 60 seconds three times at the same site. Power was regulated using a feedback control mechanism to maintain a target temperature of 75 degrees C. Ambulatory ECG monitoring was performed before and after ablation to assess arrhythmia occurrence. After follow-up, the dogs were euthanized, and lesion dimensions measured after fixation. The mean power applied to achieve the target temperature of 75 degrees C was 9.3+/-44 W. The mean depth of the lesions was 8.8+/-4.2 mm. The mean volume of the lesions was 304+/-240 mm3. Forty-four percent of the lesions were transmural. No endocardial thrombus was found. Ventricular tachycardia was observed acutely but resolved after 1 week. CONCLUSION: Temperature feedback control systems for microwave ablation using a temperature-controlled system is feasible for myocardial ablation and creates uniform and large lesions; however, such large lesions can be acutely proarrhythmic.

Animals↗

Effect of saline irrigation flow rate on temperature profile during cooled radiofrequency ablation.

INTRODUCTION: Cooled radiofrequency ablation has been developed clinically for the treatment of ventricular tachycardia. Although clinical studies employ a constant saline flow rate for cooling, we hypothesized that varying the flow rates might optimize the temperature profile at depth. METHODS: In excised ovine left ventricle, we compared the temperature profile from a catheter tip electrode thermocouple to those placed at depths of 0.0 mm, 1.0 mm, and 2.0 mm. We compared the following settings: 20 Watts without flow, 20 Watts with 0.3 cc/sec flow, 20 Watts with 0.5cc/sec flow, and 70C surface temperature without flow (temperature control). RESULTS: The temperatures decreased from 77.5 +/-10.5 degrees C, 91.7+/-6.3 degrees C, 65.5 +/- 11.8 degrees C, and 52.5 +/- 11.8 degrees C at 20W without saline irrigation at the tip, 0.0mm, 1.0mm, and 2.0 mm, respectively, to 33.0+/-1.4 degrees C, 63.4 +/- 7.0 degrees C, 57.1+/-5.8 degrees C, 49.9+/-5.8 degrees C+ at 20W with 0.5 ml/sec flow (*p<0.01, +p = 0.09). The lesion volumes were 79.6mm3 for 20W without flow, 64.1 mm3 for 20W with 0.3 ml/sec flow, 47.5 mm3 for 20W with 0.5 ml/sec flow, and 28.6 mm3 for temperature control. CONCLUSIONS: We conclude that 1) the temperature profile greatly depends upon the rate of saline flow for cooling; 2) at high flow rates, the 0.0 mm and 1.0 mm temperatures are similar; 3) even at high irrigation rates, lesion size is greater than for temperature control; 4) the tip temperature significantly underestimates the surface temperature and improved methods of measuring temperature are needed.

Animals↗

Selective activation of the K(+)(ATP) channel is a mechanism by which sudden death is produced by low-energy chest-wall impact (Commotio cordis).

BACKGROUND: Sudden death due to relatively innocent chest-wall impact has been described in young individuals (commotio cordis). In our previously reported swine model of commotio cordis, ventricular fibrillation (with T-wave strikes) and ST-segment elevation (with QRS strikes) were produced by 30-mph baseball impacts to the precordium. Because activation of the K(+)(ATP) channel has been implicated in the pathogenesis of ST elevation and ventricular fibrillation in myocardial ischemia, we hypothesized that this channel could be responsible for the electrophysiologic findings in our experimental model and in victims of commotio cordis. METHODS AND RESULTS: In the initial experiment, 6 juvenile swine were given 0.5 mg/kg IV glibenclamide, a selective inhibitor of the K(+)(ATP) channel, and chest impact was given on the QRS. The results of these strikes were compared with animals in which no glibenclamide was given. In the second phase, 20 swine were randomized to receive glibenclamide or a control vehicle (in a double-blind fashion), with chest impact delivered just before the T-wave peak. With QRS impacts, the maximal ST elevation was significantly less in those animals given glibenclamide (0.16+/-0.10 mV) than in controls (0.35+/-0.20 mV; P=0.004). With T-wave impacts, the animals that received glibenclamide had significantly fewer occurrences of ventricular fibrillation (1 episode in 27 impacts; 4%) than controls (6 episodes in 18 impacts; 33%; P=0.01). CONCLUSIONS: In this experimental model of commotio cordis, blockade of the K(+)(ATP) channel reduced the incidence of ventricular fibrillation and the magnitude of ST-segment elevation. Therefore, selective K(+)(ATP) channel activation may be a pivotal mechanism in sudden death resulting from low-energy chest-wall trauma in young people during sporting activities.

Adenosine Triphosphate↗

Long-term outcome of patients with syncope associated with coronary artery disease and a nondiagnostic electrophysiologic evaluation.

Syncope in the patient with structural heart disease and a nondiagnostic noninvasive workup is a generally accepted indication for an invasive electrophysiologic study. However, if the electrophysiologic evaluation is not highly sensitive, arrhythmic causes of syncope may not be discovered. In these patients, recurrent syncope and even sudden death may be observed at follow-up. Thus, we evaluated long-term follow-up in 68 consecutive patients who presented with syncope, coronary artery disease, and who had a negative invasive electrophysiologic evaluation. At a mean follow-up of 30 +/- 18 months (range 1 to 65), there have been 2 sudden deaths and 1 episode each of ventricular fibrillation and ventricular tachycardia in patients treated with an implantable cardioverter-defibrillator. All 4 arrhythmias occurred in patients with left ventricular fractions < or = 25%. Seventeen patients had recurrent presyncope or syncope. Bradycardia causing syncope was found in 8 of these patients. A bundle branch block at the initial evaluation predicted for the occurrence of bradycardia at follow-up. We conclude that in patients with coronary artery disease and syncope, noninducibility at electrophysiologic study predicts a lower risk of sudden death and ventricular arrhythmias. However, in patients with a reduced ejection fraction, the risk of sudden death and ventricular arrhythmias remains up to 10%/year and these patients may warrant treatment with implantable cardioverter-defibrillators. Recurrent syncope is common, and frequently a bradyarrhythmia is found to be the cause. Treatment of selected patients (especially those with bundle branch blocks) with permanent pacemakers may be justified.

Adult↗

Mechanisms of death in the CABG Patch trial: a randomized trial of implantable cardiac defibrillator prophylaxis in patients at high risk of death after coronary artery bypass graft surgery.

BACKGROUND: The CABG Patch trial compared prophylactic implantable cardiac-defibrillator (ICD) implantation with no antiarrhythmic therapy in coronary bypass surgery patients who had a left ventricular ejection fraction <0.36 and an abnormal signal-averaged ECG. There were 102 deaths among the 446 ICD group patients and 96 deaths among the 454 control group patients, a hazard ratio of 1.07 (P=0.63). The mechanisms of death were classified, and hypotheses were tested about the effects of ICD therapy on arrhythmic and nonarrhythmic cardiac deaths in the CABG Patch Trial and the Multicenter Automatic Defibrillator Implantation Trial (MADIT). METHODS AND RESULTS: The 198 deaths in the trial were reviewed by an independent Events Committee and classified by the method of Hinkle and Thaler. Only 54 deaths (27%) occurred out of hospital; 145 deaths (73%) were witnessed. Seventy-nine (82%) of the 96 deaths in the control group and 76 (75%) of the 102 deaths in the ICD group were due to cardiac causes. Cumulative arrhythmic mortality at 42 months was 6.9% in the control group and 4.0% in the ICD group (P=0. 057). Cumulative nonarrhythmic cardiac mortality at 42 months was 12. 4% in the control group and 13.0% in the ICD group (P=0.275). Death due to pump failure was significantly associated with death >1 hour from the onset of symptoms, dyspnea within 7 days of death, and overt heart failure within 7 days of death. CONCLUSIONS: In the CABG Patch Trial, ICD therapy reduced arrhythmic death 45% without significant effect on nonarrhythmic deaths. Because 71% of the deaths were nonarrhythmic, total mortality was not significantly reduced.

Anti-Arrhythmia Agents↗

Comparison of frequency of complications of implantable cardioverter-defibrillators in children versus adults.

Compared with adults patients (n = 309) receiving implantable cardioverter-defibrillators at the same institution, pediatric patients (n = 11) exhibited a trend toward lower defibrillation thresholds. At follow-up of 29 +/- 17 months, the incidence of recurrent arrhythmias was similar, but lead revisions and device infections were more common in the pediatric patients.

Adolescent↗

Intracardiac echocardiographic guidance during microwave catheter ablation.

The purpose of this study was to explore the potential of intracardiac echocardiography in monitoring lesion formation and assisting with the assessment of ablative lesions using microwave energy. Microwave energy is a promising modality for catheter ablation. Because microwave lesions may have considerable variability in dimension, the ability to assess them may be particularly useful. One hundred twenty-five microwave lesions were created in vitro in ovine left ventricles. Correct assessment of catheter-endocardial contact was possible in virtually all cases. Intracardiac imaging always identified correctly whether or not an ablation was performed. During ablation, gas formation was observed in all instances. Sensitivity, specificity, and predictive values for identification of ablation lesions were 88% to 92%. Although the correlations with pathology for lesion dimensions were relatively poor, intracardiac imaging had a predictive accuracy of 80% to 85% to discriminate small from large lesions. Intracardiac guidance for microwave ablation is useful for verifying tissue-electrode contact, monitoring lesion formation, and localizing lesions. It is also a useful tool for the assessment of lesion size. These attributes, combined with the ability to facilitate transseptal catheterization and to identify complications such as hemopericardium, make intracardiac echocardiography a potentially useful method for guiding microwave ablation of arrhythmic foci.

Animals↗

Technologic advances in implantable cardioverter defibrillators.

Multiple technologic advances in the implantable cardioverter defibrillator (ICD) have resulted in smaller size, easier implantation, and improved detection, therapy, and stored diagnostic information. Advanced dual-chamber ICDs are currently available that allow dual-chamber rate-responsive pacing with mode switching, enhanced detection algorithms, antitachycardia pacing, low-energy cardioversion, high-energy shocks, and extensive diagnostics. Based on improvements in lead systems and improved energy waveforms, almost all devices are being implanted with nonthoracotomy leads in the pectoralis area. The results of recent clinical trials have expanded indications for the ICD for primary and secondary prevention of sudden cardiac death. With advances in capacitor and battery technology coupled with improved lead systems and waveform resulting in lower defibrillation thresholds, it is likely that lower-output, smaller devices will be developed. In the future, ICDs may have expanded indications and may incorporate physiologic sensors to access hemodynamic significance of arrhythmias and algorithms for prediction and prevention of cardiac arrhythmias.

Defibrillators, Implantable↗

Cardiac arrhythmias and the athlete.

Athletes, although the healthiest segment of society, can develop cardiac arrhythmias. Benign bradycardias and atrial and ventricular premature contractions are common and seldom require treatment. Supraventricular tachycardias are less common and are usually not life-threatening, but do require treatment. Ventricular arrhythmias, although uncommon, are life-threatening and require treatment. Most athletes with ventricular arrhythmias have structural cardiac abnormalities, and further competitive play is usually prohibited. Commotio cordis, which is a recently described syndrome of sudden death caused by low-energy chest wall impact, may account for a significant percentage of the sudden deaths in athletes.

Arrhythmias, Cardiac↗

Localization of the sites of conduction abnormalities in a mouse model of myotonic dystrophy.

INTRODUCTION: A mouse strain lacking functional myotonic dystrophy protein kinase (DMPK) has recently been developed. DMPK-/- mice exhibit muscular and conduction abnormalities consistent with the disease; however, the site of abnormal cardiac conduction is unknown. METHODS AND RESULTS: Nine homozygous DMPK-/- mice and seven age matched wild-type (WT) controls underwent in vivo electrophysiologic studies using an endocardial 2-French catheter. Baseline intervals as well as Wenckebach and 2:1 cycle lengths were measured to assess AV and ventriculoatrial (VA) conduction. Effective refractory periods (ERP) and functional refractory periods were determined during atrial and ventricular premature stimulation. His-bundle recordings were obtained on all the studied animals (16/16). DMPK-/- mice had significantly prolonged PR (48.1 +/- 5.5 vs 40.9 +/- 3.9 msec, P = 0.010) and AH (36.7 +/- 4.0 vs 31.6 +/- 4.8 msec, P = 0.037) intervals compared to WT controls. HV intervals were very significantly prolonged as well (14.7 +/- 2.0 vs 10.3 +/- 0.8 msec; P < 0.0001). Three of 9 DMPK-/- and 1 of 7 WT mice exhibited VA block. Atrial ERP was reached before AV node ERP in 2 (22%) of 9 of the knockout mice and 5 (71%) of 7 of the controls (P = 0.06). Only one mouse (DMPK-/-) exhibited infra-Hisian block on premature atrial stimulation. CONCLUSION: In this mouse model of myotonic dystrophy, AV conduction abnormalities were localized to the supra-Hisian and infra-Hisian conduction tissues, with a higher predilection to the latter, a finding similar to the human form of the disease.

Animals↗

Clinical profile of commotio cordis: an under appreciated cause of sudden death in the young during sports and other activities.

Not particularly well recognized are athletic field catastrophes in which virtually instantaneous cardiac arrest is produced by nonpenetrating chest blows in the absence of heart disease or identifiable morphologic injury to the chest wall or heart (commotio cordis). To better characterize the clinical profile of this syndrome, we have assembled 70 cases, including 34 occurring during organized competitive athletics and 36 others that occurred during informal recreational sports at home, school or the playground, or during nonsporting activities. Ages were 2 to 38 (mean age: 12) with 70% < 16 years old. Most common sports involved were youth baseball (n = 40), softball (n = 7), and ice hockey (n = 7). Seven (10%) of the 70 commotio cordis victims, including six with documented ventricular fibrillation, have survived the consequences of their chest blow. Eleven of the events (16%) occurred despite the presence of chest padding believed to be potentially protective. Four victims experienced modest chest blows while in circumstances completely unrelated to sports activities; three of the four individuals who delivered these blows were ultimately convicted of criminal acts within the justice system. An experimental model of low-energy chest wall impact demonstrates that commotio cordis events are due largely to the exquisite timing of blows during a narrow window within the repolarization phase of the cardiac cycle, 15 to 30 msec prior to the peak of the T wave.

Adolescent↗

An experimental model of sudden death due to low-energy chest-wall impact (commotio cordis)

BACKGROUND: The syndrome of sudden death due to low-energy trauma to the chest wall (commotio cordis) has been described in young sports participants, but the mechanism is unknown. METHODS: We developed a swine model of commotio cordis in which a low-energy impact to the chest wall was produced by a wooden object the size and weight of a regulation baseball. This projectile was thrust at a velocity of 30 miles per hour and was timed to the cardiac cycle. RESULTS: We first studied 18 young pigs, 6 subjected to multiple chest impacts and 12 to single impacts. Of the 10 impacts occurring within the window from 30 to 15 msec before the peak of the T wave on the electrocardiogram, 9 produced ventricular fibrillation. Ventricular fibrillation was not produced by impacts at any other time during the cardiac cycle. Of the 10 impacts sustained during the QRS complex, 4 resulted in transient complete heart block. We also studied whether the use of safety baseballs, which are softer than standard ones, would reduce the risk of arrhythmia. A total of 48 additional animals sustained up to three impacts during the T-wave window of vulnerability to ventricular fibrillation with a regulation baseball and safety baseballs of three degrees of hardness. We found that the likelihood of ventricular fibrillation was proportional to the hardness of the ball, with the softest balls associated with the lowest risk (two instances of ventricular fibrillation after 26 impacts, as compared with eight instances after 23 impacts with regulation baseballs). CONCLUSIONS: This experimental model of commotio cordis closely resembles the clinical profile of this catastrophic event. Whether ventricular fibrillation occurred depended on the precise timing of the impact. Safety baseballs, as compared with regulation balls, may reduce the risk of commotio cordis.

Animals↗

Quality of life and clinical outcomes in elderly patients treated with ventricular pacing as compared with dual-chamber pacing. Pacemaker Selection in the Elderly Investigators.

BACKGROUND: Standard clinical practice permits the use of either single-chamber ventricular pacemakers or dual-chamber pacemakers for most patients who require cardiac pacing. Ventricular pacemakers are less expensive, but dual-chamber pacemakers are believed to be more physiologic. However, it is not known whether either type of pacemaker results in superior clinical outcomes. METHODS: The Pacemaker Selection in the Elderly study was a 30-month, single-blind, randomized, controlled comparison of ventricular pacing and dual-chamber pacing in 407 patients 65 years of age or older in 29 centers. Patients received a dual-chamber pacemaker that had been randomly programmed to either ventricular pacing or dual-chamber pacing. The primary end point was health-related quality of life as measured by the 36-item Medical Outcomes Study Short-Form General Health Survey. RESULT: The average age of the patients was 76 years (range, 65 to 96), and 60 percent were men. Quality of life improved significantly after pacemaker implantation (P<0.001), but there were no differences between the two pacing modes in either the quality of life or prespecified clinical outcomes (including cardiovascular events or death). However, 53 patients assigned to ventricular pacing (26 percent) were crossed over to dual-chamber pacing because of symptoms related to the pacemaker syndrome. Patients with sinus-node dysfunction, but not those with atrioventricular block, had moderately better quality of life and cardiovascular functional status with dual-chamber pacing than with ventricular pacing. Trends of borderline statistical significance in clinical end points favoring dual-chamber pacing were observed in patients with sinus-node dysfunction, but not in those with atrioventricular block. CONCLUSION: The implantation of a permanent pacemaker improves health-related quality of life. However, the quality-of-life benefits associated with dual-chamber pacing as compared with ventricular pacing are observed principally in the subgroup of patients with sinus-node dysfunction.

Aged↗

Complications of dual chamber pacemaker implantation in the elderly. Pacemaker Selection in the Elderly (PASE) Investigators.

Pacemakers are frequently implanted, yet accurate prospective data on implant complications are limited. Elderly patients may be at increased risk of implant complications and are increasingly being referred for pacemaker implantation. The purpose of the present analysis was to define the incidence and possible predictors of serious complications of dual chamber permanent pacemaker implantation in the elderly. Therefore, we sought to prospectively identify the incidence and predictors of pacemaker implant complications in a large multicenter trial involving patients receiving a dual chamber pacemaker. The Pacemaker Selection in the Elderly (PASE) study was a prospective trial designed to evaluate quality of life in dual chamber pacemaker recipients age 65 years or older randomized to DDDR versus VVIR programming. In addition to being age 65 years or older, patients enrolled in this study were in normal sinus rhythm, and had standard indications for permanent pacemaker implantation. All patients received dual chamber pacemakers and were randomized to DDDR versus VVIR pacing. Pacemaker implant complications were collected on standardized forms which were completed at pacemaker implantation and during follow-up appointments. In this study of 407 patients, there were 26 complications occurring in 25 patients (6.1%). The most frequent complication was lead dislodgment which occurred in 9 patients. This was followed by pneumothorax (8 patients) and cardiac perforations (4 patients). In 18 patients (4.4%) repeat surgical procedures (including chest tubes) were required. Complications were noted prior to discharge in only 18 patients. There were no significant predictors of overall complications. Pneumothorax was more frequent in patients > or = 75 years old, and was observed only in patients with subclavian venous access. In conclusion, complications from pacemaker implantation in the elderly are seen in 6.1% of patients and 4.4% of patients require a repeat surgical procedure. Other than advanced age and lower weight predicting for pneumothorax, there are no significant clinical predictors of complications.

Age Factors↗