Search PubMed⌕ Search

Biomedical subjects

Muzammil A Arain

Publications and source records attributed to Muzammil A Arain.

6 recordsLinked to original sources

Optoelectronic approach to adaptive radio-frequency transversal filter implementation with negative coefficients by using optical spectrum shaping.

A multitap negative and positive coefficient radio-frequency transversal filter is implemented by using a digital-micromirror-device spatial light modulator for weighting-factor control and a chirped fiber Bragg grating for time-delay control. The demonstrated architecture is reconfigurable, has high speed and low loss, and is robust through digital programmability for a wide variety of filtering algorithms. A design using an interleaver for differential detection realizes an ultrahigh bandwidth with a maximum processable frequency of 33.7 GHz. A multitap low-pass filter, a negative tap notch filter with 40 dB attenuation, and a multitap negative coefficient bandpass filter are experimentally demonstrated. The results are in agreement with theory.

Journal Article↗

Programmable broadband radio-frequency transversal filter with compact fiber-optics and digital microelectromechanical system-based optical spectral control.

To the best of our knowledge, for the first time a programmable broadband rf transversal filter is proposed that operates on the principle of broadband optical spectral control implemented with a spatial light modulator input rf signal time delay and weight selection over a near-continuous signal space. Specifically, the filter uses a chirped fiber Bragg grating in combination with a two-dimensional digital micromirror device to enable a programmable rf filter. As a first step, a two-tap rf notch filter is demonstrated with a tuning range of 0.563-6.032 GHz with a 25-dB notch depth at test notch frequencies of 845 and 905 MHz. The proposed filter can find applications in diverse fields such as radar, communications, medicine, and test and measurement.

Journal Article↗

Superwide-angle coverage code-multiplexed optical scanner.

A superwide-angle coverage code-multiplexed optical scanner is presented that has the potential to provide 4 pi-sr coverage. As a proof-of-concept experiment, an angular scan range of 288 degrees for six randomly distributed beams is demonstrated. The proposed scanner achieves its superwide coverage by exploiting a combination of phase-encoded transmission and reflection holography within an in-line hologram recording-retrieval geometry. The basic scanner unit consists of one phase-only digital mode spatial light modulator for code entry (i.e., beam scan control) and a holographic material from which we obtained what we believe is the first-of-a-kind extremely wide coverage, low component count, high speed (e.g., microsecond domain), and large aperture (e.g., > 1-cm diameter) scanner.

Journal Article↗

High-speed two-dimensional laser scanner based on Bragg gratings stored in photothermorefractive glass.

A high-speed free-space wavelength-multiplexed optical scanner with high-speed wavelength selection coupled with narrowband volume Bragg gratings stored in photothermorefractive (PTR) glass is reported. The proposed scanner with no moving parts has a modular design with a wide angular scan range, accurate beam pointing, low scanner insertion loss, and two-dimensional beam scan capabilities. We present a complete analysis and design procedure for storing multiple tilted Bragg-grating structures in a single PTR glass volume (for normal incidence) in an optimal fashion. Because the scanner design is modular, many PTR glass volumes (each having multiple tilted Bragg-grating structures) can be stacked together, providing an efficient throughput with operations in both the visible and the infrared (IR) regions. A proof-of-concept experimental study is conducted with four Bragg gratings in independent PTR glass plates, and both visible and IR region scanner operations are demonstrated.

Journal Article↗

Angstrom-range optical path-length measurement with a high-speed scanning heterodyne optical interferometer.

A highly accurate method of optical path-length measurement is introduced by use of a scanning heterodyne optical interferometer with no moving parts. The instrument has demonstrated the potential to measure optical path length at angstrom resolution over continuous thickness in the micrometer range. This optical path length can be used to calculate the thickness of any material if the refractive index is known or to measure the refractive index of the material if the thickness is known. The instrument uses a single acousto-optic device in an in-line ultra-stable reflective geometry to implement rapid scanning in the microsecond domain for thickness measurements of the test medium.

Journal Article↗

Code-multiplexed optical scanner.

A three-dimensional (3-D) optical-scanning technique is proposed based on spatial optical phase code activation on an input beam. This code-multiplexed optical scanner (C-MOS) relies on holographically stored 3-D beam-forming information. Proof-of-concept C-MOS experimental results by use of a photorefractive crystal as a holographic medium generates eight beams representing a basic 3-D voxel element generated via a binary-code matrix of the Hadamard type. The experiment demonstrates the C-MOS features of no moving parts, beam-forming flexibility, and large centimeter-size apertures. A novel application of the C-MOS as an optical security lock is highlighted.

Journal Article↗