Search PubMed⌕ Search

Biomedical subjects

Mustafa Soylak

Publications and source records attributed to Mustafa Soylak.

At least 19 recordsLinked to original sources

Solid phase extraction of gold(III) on Amberlite XAD-2000 prior to its flame atomic absorption spectrometric determination.

A solid phase extraction method for the determination of gold(III) at trace levels by flame atomic absorption spectrometer (FAAS) was developed. The method was based on retention of gold as chloro complexes through the Amberlite XAD-2000. The effect of some analytical parameters including hydrochloric acid concentration, sample volume, sample and eluent flow rates, eluent volume, eluent concentration and interfering ions on the recovery of gold(III) was investigated. The retention of gold(III) from 1.5 mol l(-1) HCl solution and the recovery of gold with 0.07 mol l(-1) NH3 solution were quantitative (>or=95%). The relative standard deviation (RSD) was calculated as 3.2% (n = 10). The detection limit for gold was 2 microg l(-1). The accuracy was checked with the determination of gold spiked an artificial seawater and a pure copper samples.

Adsorption↗

Solid-phase extraction of Mn(II), Co(II), Ni(II), Cu(II), Cd(II) and Pb(II) ions from environmental samples by flame atomic absorption spectrometry (FAAS).

A new method using a column packed with Amberlite XAD-2010 resin as a solid-phase extractant has been developed for the multi-element preconcentration of Mn(II), Co(II), Ni(II), Cu(II), Cd(II), and Pb(II) ions based on their complex formation with the sodium diethyldithiocarbamate (Na-DDTC) prior to flame atomic absorption spectrometric (FAAS) determinations. Metal complexes sorbed on the resin were eluted by 1 mol L(-1) HNO3 in acetone. Effects of the analytical conditions over the preconcentration yields of the metal ions, such as pH, quantity of Na-DDTC, eluent type, sample volume and flow rate, foreign ions etc. have been investigated. The limits of detection (LOD) of the analytes were found in the range 0.08-0.26 microg L(-1). The method was validated by analyzing three certified reference materials. The method has been applied for the determination of trace elements in some environmental samples.

Acetone↗

A multi-element solid-phase extraction method for trace metals determination in environmental samples on Amberlite XAD-2000.

A method for the preconcentration of some transition elements at trace level was proposed using a column filled with Amberlite XAD-2000 resin. Metal ions were adsorbed on XAD-2000 as their diethyldithiocarbamate chelates, then analytes retained on the resin were eluted by 1 mol L(-1) nitric acid in acetone and determined by flame atomic absorption spectrometry (FAAS). The influences of some analytical parameters including pH of sample solution, ligand amount, the type, concentration and volume of elution solution, flow rates of the sample and eluent solutions, adsorption capacity of the resin and sample volume on the preconcentration efficiency have been investigated. The influences of some matrix elements were also examined. The detection limit (N=20, 3 sigma) for Mn(II), Fe(II), Co(II), Cu(II), Cd(II), Zn(II), Pb(II) and Ni(II) were found as 0.20, 0.35, 0.25, 0.20, 0.20, 0.15, 0.45 and 0.25 microg L(-1), respectively. The validation of the procedure was carried out by analysis of certified reference materials. The proposed method was applied to natural waters and kale vegetable (Brassica oleracea var. acephala).

Brassica↗

Separation/preconcentration of silver(I) and lead(II) in environmental samples on cellulose nitrate membrane filter prior to their flame atomic absorption spectrometric determinations.

An enrichment method for trace amounts of Ag(I) and Pb(II) has been established prior to their flame atomic absorption spectrometric determinations. The preconcentration/separation procedure is based on chelate formation of Ag(I) and Pb(II) with ammonium pyrrolidine dithiocarbamate (APDC) and on retention of the chelates on cellulose nitrate membrane filter. The influences of some analytical parameters including pH and amounts of reagent, etc. on the recoveries of analytes were investigated. The effects of interferic ions on the quantitative recoveries of analytes were also examined. The detection limits (k=3, N=11) were 4.6 microg L(-1) for silver(I) and 15.3 microg L(-1) for lead(II). The relative standard deviations (R.S.D.) of the determinations for analyte ions were below 3%. The method was applied to environmental samples for the determination of analyte ions with satisfactory results (recoveries>95%).

Adsorption↗

Preconcentration of Pb(II), Cr(III), Cu(II), Ni(II) and Cd(II) ions in environmental samples by membrane filtration prior to their flame atomic absorption spectrometric determinations.

A method for separation-preconcentration of Pb(II), Cr(III), Cu(II), Ni(II) and Cd(II) ions by membrane filtration has been described. The method based on the collection of analyte metal ions on a cellulose nitrate membrane filter and determination of analytes by flame atomic absorption spectrometry (FAAS). The method was optimized for several parameters including of pH, matrix effects and sample volume. The recoveries of analytes were generally in the range of 93-100%. The detection limits by 3 sigma for analyte ions were 0.02microgL(-1) for Pb(II), 0.3microgL(-1) for Cr(III), 3.1microgL(-1) for Cu(II), 7.8microgL(-1) for Ni(II) and 0.9microgL(-1) for Cd(II). The proposed method was applied to the determination of lead, chromium, copper, nickel and cadmium in tap waters and RM 8704 Buffalo River Sediment standard reference material with satisfactory results. The relative standard deviations of the determinations were below 10%.

Cadmium↗

SP70-alpha-benzoin oxime chelating resin for preconcentration-separation of Pb(II), Cd(II), Co(II) and Cr(III) in environmental samples.

In the presented work, alpha-benzoin oxime immobilized SP70 chelating resin was synthesized for separation and preconcentration of Pb(II), Cd(II), Co(II) and Cr(III). The optimization procedure for analytical parameters including pH, eluent type, flow rate, etc. was examined in order to gain quantitative recoveries of analyte ions. The effects of foreign ions on the recoveries of studied metal ions were also investigated. The detection limits (3sigma) were found to be 16.0, 4.2, 1.3, 2.4microgL(-1) for Pb, Cd, Co and Cr, respectively. The preconcentration factor was 75 for Pb, 100 for Cd, Co and Cr. The optimized method was validated with certified reference materials and successfully applied to the waters, crops and pharmaceutical samples with good results (recoveries greater than 95%, R.S.D. lower than 10%).

Benzoin↗

Cr(VI) and Cr(III) speciation on Bacillus sphaericus loaded diaion SP-850 resin.

A speciation procedure for chromium(III) and chromium(VI) in the environmental samples has been established in the presented work. The procedure presented based on quantitative biosorption of chromium(III) on Bacillus sphaericus loaded Diaion SP-850 at pH 5. The Cr(VI) recoveries at pH 5 were below 5% on the biosorbent. After reduction of Cr(VI) by concentrated H(2)SO(4) and ethanol, the system was applied to the total chromium. Cr(VI) was calculated as the difference between the total chromium content and the Cr(III) content. Optimal analytical conditions including pH, amounts of biosorbent, etc. for Cr(III) recoveries were investigated. The influences of the some alkaline and earth alkaline ions and some transition metals on the recoveries were also investigated. The capacity of biosorbent for chromium(III) was 6.95 mgg(-1). The detection limit (3 sigma) of the reagent blank for chromium(III) was 0.50 microgL(-1). The procedure was successfully applied to the speciation of chromium(III) and chromium(VI) in natural water samples (R.S.D. lower than 5%, recoveries greater than 95%).

Adsorption↗

Membrane filtration - atomic absorption spectrometry combination for copper, cobalt, cadmium, lead and chromium in environmental samples.

Cellulose nitrate membrane filter was used for the preconcentration-separation of Cu, Co, Cd, Pb and Cr ions. The analyte ions were collected on the membrane filter by the aid of carmine. Then membrane filter was dissolved by using nitric acid. The levels of the analytes in the final solutions were determined by flame atomic absorption spectrometry (FAAS). The analytical parameters including pH, amounts of carmine, sample volumes etc. have been optimized. No influences have been observed from the matrix ions. The detection limits for analytes were in the range of 0.08 microg/l-0.93 microg/l. The validation of the procedure was checked by the analysis of standard reference sediment (GBW 07309). The present method has been successfully applied for the FAAS determinations of analyte ions in real samples including black tea and magnesium salts.

Collodion↗

Heavy metal contents of the karasu creek sediments, Nigde, Turkey.

Heavy metal contamination in sediments of the Karasu spring was investigated in the presented study. In this respect, sediment samples were collected from contaminant sites along the spring starting from the spring water manifestation site, base of the Akkaya dam to the dam exit site. Heavy metal concentrations were determined by X-ray Fluorescence Spectrometer. Cobalt, copper, arsenic, tin, nickel, zinc, cadmium, lead, aluminum, iron, titan, chromium and manganese contents of the Karasu creek sediments are found as 18.30-69.00, 12.40-595.0 5.50-345.3, 5.80-15.1, 10.9-64.1, 28.90-103,300, 4.1-356.2, 7.70-37,840, 13,460-109,400, 11,740-62,900, 22.18-59.04, 41.70-369 and 12.09-3,480 mg/kg, respectively. Results indicate the presence of a contamination in the Karasu creek. All the metal concentrations were found to be exceeding their acceptable limit values. Eutrophication is developed in the Karasu creek and the Akkaya dam. It is thought that heavy metal accumulation in the creek is originated from discharge from mine quarries, industrial and domestic wastes. Protection zones should be defined and all necessary measures must be taken along the Karasu creek.

Geologic Sediments↗

Dysprosium(III) hydroxide coprecipitation system for the separation and preconcentration of heavy metal contents of table salts and natural waters.

A procedure for the determination of trace amounts of Pb(II), Cu(II), Ni(II), Co(II), Cd(II) and Mn(II) is described, that combines atomic absorption spectrometry-dysprosium hydroxide coprecipitation. The influences of analytical parameters including amount of dysprosium(III), centrifugation time, sample volume, etc. were investigated on the recoveries of analyte ions. The effects of concomitant ions were also examined. The recoveries of the analyte ions were in the range of 95.00-104.00%. The detection limits corresponding to three times the standard deviation of the blank for the analytes were in the range of 14.1-25.3 microg/L. The method was applied to the determination of lead, copper, nickel, cobalt, cadmium and manganese ions in natural waters and table salts good results were obtained (relative standard deviations <10%, recoveries >95%).

Centrifugation↗

Adsorption of Pb(II) and Cr(III) from aqueous solution on Celtek clay.

This paper presents the adsorption of Pb(II) and Cr(III) from aqueous solution on Celtek clay. Batch experiments were carried out as a function of the adsorbent dosage, solution pH, shaking time, and temperature. The equilibrium data of fitted well with the linear Langmuir and Freundlich models. Dubinin-Radushkevick (D-R) isotherm model was applied to describe the nature of the adsorption of the metals, and found that it occurred physically. Thermodynamic parameters, the change in Gibbs free energy change (DeltaG degrees), enthalpy (DeltaH degrees) and entropy (DeltaS degrees) were also calculated. These parameters indicated that the adsorption of Pb(II) and Cr(III) on Celtek clay was feasible, spontaneous and exothermic process in nature. Based on the results, it was concluded that Celtek clay had a significant potential for removing Pb(II) and Cr(III) from wastewater using adsorption method.

Adsorption↗

Sorbent extraction of rubeanic acid-metal chelates on a new adsorbent: Sepabeads SP70.

A sorbent extraction procedure for lead, iron, cadmium and manganese ions on Sepabeads SP70 adsorption resin has been presented prior to their flame atomic absorption spectrometric determinations. By the passage of aqueous samples including analyte ions-rubeanic acid chelates through Sepabeads SP70 column, metal chelates adsorb quantitatively and almost all matrix elements will pass through the column to drain. The influence of potential interfering ions was also studied. The validation of the method was made though the analysis of LGC 6010 Hard drinking water, SRM 1577b Bovine liver and GBW 07603 Bush branches and leaves standard reference materials (SRM). The method was applied to the determination of analyte ions from various water, wastewater, cow meat and milk, red wine, and tobacco samples with successfully results.

Adsorption↗

Copper(II)-rubeanic acid coprecipitation system for separation-preconcentration of trace metal ions in environmental samples for their flame atomic absorption spectrometric determinations.

A simple and facile preconcentration procedure based on the coprecipitation of trace heavy metal ions with copper(II)-rubeanic acid complex has been developed. The analytical parameters including pH, amounts of rubeanic acid, sample volume, etc. was investigated for the quantitative recoveries of Pb(II), Fe(III), Cd(II), Au(III), Pd(II) and Ni(II). No interferic effects were observed from the concomitant ions. The detection limits for analyte ions by 3 sigma were in the range of 0.14 microg/l for iron-3.4 microg/l for lead. The proposed coprecipitation method was successfully applied to water samples from Palas Lake-Kayseri, soil and sediment samples from Kayseri and Yozgat-Turkey.

Cadmium↗

Determination of trace metals by atomic absorption spectrometry after coprecipitation with europium hydroxide.

A procedure for the determination of trace amounts of chromium(III), iron(III), lead(II) and manganese(II) is described, that combines atomic absorption spectrometry-europium hydroxide coprecipitation. The influences of analytical parameters including amount of europium(III), amount of ammonia, sample volume, etc. were investigated on the recoveries of analyte ions. The effects of concomitant ions were also examined. The recoveries of the analyte ions were in the range of 95-104%. The detection limits (3 s) were in the range of 1.7-17.1 microg/L. The validation of the presented coprecipitation procedure was performed by the analysis of Bovine Liver 1577-b and BCR-144R Sewage Sludge (domestic origin) standard reference materials. The method was applied to the determination of analytes in real samples including natural waters and some food, soil and fertilizer samples, etc. and good results were obtained (relative standard deviations < 10%, recoveries > 95%).

Animals↗

Diaion SP-850 resin as a new solid phase extractor for preconcentration-separation of trace metal ions in environmental samples.

A solid phase extraction method was developed for the preconcentration and separation of trace amounts of chromium, manganese, iron, cobalt, copper, cadmium and lead from environmental samples by complexation with alpha-benzoin oxime followed by adsorption onto Diaion SP-850-solid phase extraction column. One molar per liter HNO(3) was used as eluent. The recoveries of analytes at pH 8.0 with 700 mg of resin were greater than 95% without interference from alkaline, earth alkaline and some metal ions. The detection limits by three sigma for analyte ions were 0.65 microg l(-1) for Cr(III), 0.42 microg l(-1) for Mn(II), 0.28 microg l(-1) for Fe(III), 0.73 microg l(-1) for Co(II), 0.30 microg l(-1) for Cu(II), 0.47 microg l(-1) for Cd(II) and 0.50 microg l(-1) for Pb(II). The validation of the procedure was performed by the analysis of the certified standard reference materials. The presented procedure was applied to the determination of analytes in tap, river and sea waters, rice, wheat, canned tomato and coal samples with successfully results (recoveries greater than 95%, R.S.D.'s lower than 8%).

Acrylic Resins↗

Speciation of Cr(III) and Cr(VI) in environmental samples by solid phase extraction on Ambersorb 563 resin.

A simple and sensitive method for the speciation, separation and preconcentration of Cr(VI) and Cr(III) in natural water, soil and sediment samples was developed. Cr(VI) has been separated from Cr(III) and preconcentrated as Cr(III)-diphenylcarbazone complex by using Ambersorb 563 resin and determined by spectrophotometric method at 540 nm. Effect of analytical parameters such as sulfuric acid concentration, ligand volume, type of elution solution, sample volume, amount of resin and foreign ions were investigated. The presented procedure was successfully applied for the chromium speciation in various environmental samples with successfully results.

Absorption↗

Celtek clay as sorbent for separation-preconcentration of metal ions from environmental samples.

The sorption conditions including pH of the aqueous solution, sample volume, etc., on Celtek clay of copper(II), cadmium(II), lead(II), chromium(III), nickel(II) and cobalt(II) ions from environmental samples has been studied. The effects of electrolytes as matrix on the preconcentration were also investigated with the recoveries >95%. The 3 sigma detection limits for copper, cadmium, lead, chromium, nickel and cobalt ions were found to be 0.25, 0.32, 0.73, 0.45, 0.50 and 0.41 microg/l, respectively. The relative standard deviation was <10% for the determination of analytes. The procedure was validated by analysis of a NRCC-SLRS 4 Riverine Water, SRM 1573a Tomato leaves and IAEA 336 Lichen standard reference materials. The developed method was successively utilized for the determination of Cu(II), Cd(II), Pb(II), Cr(III), Ni(II) and Co(II) in various samples including natural waters, wheat and human hair by flame atomic absorption spectrometry (FAAS) with satisfactorily results (recoveries>95% and R.S.D.'s<10%).

Adsorption↗

Trace metal pollution from traffic in Denizli-Turkey during dry season.

OBJECTIVE: To determine the metal contents of date palm (Pheonix dactylifera) samples in dry season from Denizli-Turkey for investigation of heavy metal-polluted traffic. METHOD: The levels of iron, copper, zinc, lead, cadmium, nickel, chromium, and manganese ions in the leaves of thirty five date palm (Pheonix dactylifera) samples collected from various levels of traffic in the streets of Denizli-Turkey were determined by graphite furnace or flame atomic absorption spectrometry. The wet, dry, and microwave digestion procedures for the date palm (Pheonix dactylifera) leaves were compared. The accuracy of the digestion procedures was checked using a standard reference material (IAEA-336 Lichen, SRM). RESULTS: Microwave digestion procedure for the leaves was preferred because it was more proper with respect to both time and recovery than dry and wet digestion. The levels of the heavy metal ions investigated were the highest on the samples from high traffic level. Also correlations between metal levels and traffic volume for all the metals were investigated. CONCLUSION: In the light of our findings, the date palm (Phoenix dactylifera) leaves are suitable as a biomonitor for atmospheric heavy metal-polluted traffic. Significant correlations can be obtained between traffic levels and heavy metal concentrations.

Air Pollutants↗