Determination of phenolic compounds in fennel by HPLC and HPLC-MS using a monolithic reversed-phase column.

A reversed-phase high-performance liquid chromatography (HPLC) method for analyzing phenolic compounds in fennel (Foeniculum vulgare) has been developed. The use of a monolithic column with short dimensions in combination with optimized chromatographic conditions allows over 100 samples per day to be analyzed. Chromatographic parameters such as column temperature and injection volume, were found to be crucial in obtaining adequate selectivity and resolution, consequently allowing short run times. The method was validated for the major phenolic compounds present in fennel plant material: 3-O-caffeoylquinic acid (3-CQA), chlorogenic acid, 4-O-caffeoylquinic acid (4-CQA), eriocitrin, rutin, miquelianin, 1,3-O-dicaffeoylquinic acid (1,3-diCQA), 1,5-O-dicaffeoylquinic acid (1,5-diCQA), 1,4-O-dicaffeoylquinic acid (1,4-diCQA) and rosmarinic acid. The limits of detection (LOD) and the limits of quantitation (LOQ) ranged from 0.05 to 1.0 microg/mL and from 0.15 to 2.5 microg/mL, respectively. With some adaptation, the extraction procedure could be even less invasive, which is useful in screening work.

Chlorogenic Acid↗

Evaluation of a rinsing-based cleaning process for pipes.

Pipes of various designs were constructed. Pipes were filled with a model solution resembling a dermal solution product. After the removal of the model solution, pipes were rinsed several times with ethanol and rinsing solutions of each step analyzed by gas chromatography. The results gave the information about the dependency between the configuration of the pipe and the efficiency of the cleaning operation. From concentrations measured in the reactor, expected concentrations in rinsing solutions from pipes were predicted. The obtained results confirm that the amount of residues per surface area increases when a pipe includes bends and valves. In terms of extra contamination, each bend was equal to 25 cm, while each valve was equal to 100 cm of pipe length when pipes of 1.8 cm in diameter were used. It was proven that the contributions of individual valves and bends in the pipe are additive in the calculation. The validity of the proposed model was confirmed by experimental data.

Drug Contamination↗

Uncertainty in quantitative thin-layer chromatography.

Globalization forces analysts to demand extended control of variability in analytical measurements. A calculation procedure named the "error budget model" following recommendations proposed more than 20 years ago by the Bureau International des Poids et Mesures is established as a rule for evaluating and expressing the measurement uncertainty across a broad spectrum of measurements. This metrological approach common in physical measurement is not applicable in separation techniques and cannot quantitate measurement uncertainty. Our experiments show that it can be used as a planning tool in the validation of thin-layer chromatographic (TLC) methods. A computer program that quantitates uncertainty components associated with potential sources of uncertainty in quantitative TLC is prepared and tested with experimental data. TLC plates with different qualities of stationary phases (TLC and high-performance TLC) spotted with different types of samples are measured. Application is performed manually and automatically. Plates are scanned with UV-vis scanners and a video documentation system in remission and transmission mode and fluorescence. Although the calculated values are close to the values obtained with validation procedures, the error budget approach cannot substitute validation. Calculated results can predict critical points in real quantitative TLC, but they cannot confirm the validity of a selected chromatographic procedure.

Journal Article↗

Determination of phenylalanine and tyrosine by liquid chromatography/mass spectrometry.

Phenylketonuria is a common metabolic disorder disease. Those affected appear normal at birth, but without treatment they develop severe psychomotor retardation. Throughout life, they must control their blood levels of phenylalanine (Phe) and consume a diet containing adequate amounts of Phe and tyrosine (Tyr). We have developed a liquid chromatographic/mass spectrometric (LC/MS) method for the quantitative evaluation of Phe and Tyr in food samples. This method takes advantage of the good separation of LC and the selective and reliable quantification provided by MS in the electrospray ionization mode. The LC/MS method is very suitable for the determination of selected amino acids in various matrixes. It is sensitive to levels as low as about 0.30 ppm for Tyr and 0.70 ppm for Phe and robust. Nearly 100 nondietary food samples were analyzed by the developed method.

Chromatography, Liquid↗

Quantitative determination of coenyzme Q10 by liquid chromatography and liquid chromatography/mass spectrometry in dairy products.

The dietary sources of CoQ10 and the evaluation of CoQ10 in dairy products were characterized. For quantitation of CoQ10 in food samples, 2 liquid chromatography (LC) methods with UV and mass spectrometry (MS) detections were developed. LC with UV detection was performed at 25 degrees C on a Hyperclone ODS 5 microm 150 x 4.6 mm column with mobile phase consisting of methanol-ethanol-2-propanol (70 + 15 + 15, v/v/v). Flow rate was 1.0 mL/min. Retention time of CoQ10 was 10.9 +/- 0.1 min. The method was sensitive [limit of detection (LOD) = 0.2 mg/kg], reproducible [relative standard deviation (RSD) = 3:0%), and linear up to 25 mg/kg (R > 0.999). LC/MS analysis was performed on a LUNA C18 3 microm, 150 x 4.6 mm column, using mobile phase consisting of ethanol-dioxane-acetic acid (9 + 1 + 0.01, v/v/v), flow rate was 0.6 mL/min, and the retention time of CoQ10 was 4.1 +/- 0.1 min. Identification and quantitation were performed with a Finnigan-LCQ mass detector in positive atmospheric pressure chemical ionization mode. Mass spectra were obtained in selected-ion monitoring mode; molecular mass (M+H)+ m/z 863.4 +/- 1 was used for quantitative determination. MS detection is more sensitive than UV detection (LOD = 0.1 mg/kg), less reproducible (RSD = 4.0%), and linear in selected range. Analytical recoveries are 75-90% and depend on the ratio between the amount of fat in the matrix and the concentration of CoQ10 in the sample. Some soybean milk products were analyzed together with different cow, goat, and sheep milk products. Concentrations obtained with LC and LC/MS were compared with a few accessible results available from the literature. Concentrations varied from 0 ppm in soybean milk to nearly 2 ppm in fresh milk from local farms.

Acetic Acid↗