Search PubMed⌕ Search

Biomedical subjects

Mirko Nitschke

Publications and source records attributed to Mirko Nitschke.

9 recordsLinked to original sources

Thermo-responsive poly(NiPAAm-co-DEGMA) substrates for gentle harvest of human corneal endothelial cell sheets.

Gentle harvesting of corneal endothelial cell sheets grown in culture is of interest for the development of cornea replacement strategies. Thin films of a fast responding copolymer of N-isopropylacrylamide (NiPAAm) and diethyleneglycol methacrylate (DEGMA) with a phase transition temperature of 32 degrees C were prepared and evaluated for that purpose. The polymer layers were immobilized onto fluorocarbon substrates using low pressure argon plasma treatment. Cell culture and detachment experiments were performed with L929 mouse fibroblasts and human corneal endothelial cells (HCEC) at standard conditions. The hydrogel-coated supports were found to permit adhesion, spreading, and proliferation of both cell types. Harvesting of cell sheets was achieved upon lowering the temperature to about 30 degrees C. The formation of a closed monolayer as a crucial prerequisite for maintaining ionic pump function in HCEC was proven by ZO-1 immunostainung. Labeling of fibronectin indicated that the vast majority of the extracellular matrix is detached from the hydrogel coatings together with the cell layer. Inspired by this result, the reuse of the hydrogel-coated culture carriers was investigated confirming the suitability of the substrates for repeated cell harvesting. Altogether, the introduced thermoresponsive coating was found advantageous for the efficient generation of HCEC sheets and will be further utilized in transplantation strategies.

Animals↗

Surface modification of poly(hydroxybutyrate) films to control cell-matrix adhesion.

Tailoring surface properties of degradable polymer scaffolds is key to progress in various tissue engineering strategies. Poly(3-hydroxybutyrate) and poly(3-hydroxybutyrate-co-4-hydroxybutyrate) thin films were modified by low pressure ammonia plasma, low pressure water vapour plasma, or immersion in a sodium hydroxide solution to elaborate means to control the cell-matrix adhesion of human umbilical cord vein endothelial cells grown on these materials. Fibronectin (FN) heteroexchange and cell adhesion were correlated to the physicochemical characteristics of the modified polymer surfaces which were investigated by X-ray photoelectron spectroscopy (XPS), scanning force microscopy (SFM), electrokinetic measurements, and contact angle measurements. All treatments increased the hydrophilicity of the polymer samples, which could be accounted to newly created amine or carboxyl functionalities for ammonia plasma or water vapour plasma treatments, respectively, and ester hydrolysis for treatments with alkaline aqueous solutions. Main features of cell adhesion and FN reorganisation-evaluated after 1h and after 5 days-could be attributed to the anchorage strength of pre-coated FN layers at the polymer surface, which was, in turn found to be triggered by the type of modification applied. In line with earlier studies referring to different materials cell adhesion and matrix reorganisation were shown to be sensitively controlled through the physicochemical profile of poly(hydroxybutyrate) surfaces.

Cell Adhesion↗

Immobilized hyperbranched glycoacrylate films as bioactive supports.

[Image: see text] We report on the low-pressure plasma immobilization, characterization and application of thin films of hyperbranched glycoacrylates, poly(3-O-acryloyl-alpha,beta-D-glucopyranoside) (AGlc), on PTFE-like fluorocarbon surfaces. This method is an efficient and versatile way to immobilize sugar-carrying branched acrylates as thin films of approximately 5 nm thickness on polymeric substrates while the functional groups and properties of the immobilized molecules are largely retained. The extent of poly(AGlc) degradation during plasma immobilization was investigated using FTIR-ATR spectroscopy and XPS. The thickness and topography of the immobilized films were characterized using spectroscopic ellipsometry and SFM, respectively. Studies of protein adsorption, as well as cell adhesion and proliferation on the poly(AGlc) surfaces, showed that these materials are suitable for the control of biointerfacial phenomena. Fluorescence images of fibronectin adsorbed on to the branched glycoacrylate with a mask.

Acrylates↗

In situ study of the thermoresponsive behavior of micropatterned hydrogel films by imaging ellipsometry.

A patterned hydrogel was immobilized on a polymer substrate by low-pressure argon plasma treatment using a masking technique. The polymer sample showed a thermoresponsive aggregation behavior in the region of 35-37 degrees C. The micropatterned, thermoresponsive hydrogel film has been characterized with imaging ellipsometry. The characterization was carried out on the dry film as well as on a swollen sample in water. The thermoresponsive behavior was studied in deionized water by temperature-dependent measurements in a solid-liquid cell. Through imaging ellipsometry, it was possible to distinguish the different regions of interest on a micrometer scale and to follow the swelling of the hydrogel part as a function of the temperature. It was possible to visualize the swelling as 3D profiles of Delta at various temperatures. Long-term changes of the sample could also be detected, which cannot be picked up by conventional ellipsometry.

Journal Article↗

Immobilization of an anticoagulant benzamidine derivative: effect of spacer arms and carrier hydrophobicity on thrombin binding.

Prevention of blood coagulation is very often a prerequisite for successful medical devices. For that purpose, passivation of the key coagulation enzyme thrombin through the derivatization of the material's surface with an amidine-based molecule has been found to be promising. To further enhance the efficiency of this approach, thin layers of maleic anhydride copolymers offering different physico-chemical characteristics were tethered with carboxyl terminated polyethylene glycol to covalently immobilize a benzamidine-type derivative. The free carboxyl surface groups produced by the attachment of polyethylene glycol (PEG) were quantified by Ag(+) labeling and subsequent XPS detection. The film thickness as well as the carboxyl group content were found to be clearly dependent on the copolymer hydrophobicity and the nature of the PEG molecule. For the assessment of the anchorage of the thrombin to the benzamidine-derivative functionalized surfaces, the substrates were immersed in a buffered thrombin solution and the enzyme adsorption was studied using immunostaining/confocal laser scanning microscopy. Higher degrees of thrombin binding were observed for substrates configured with the hydrophilic compared to the more hydrophobic copolymer. Moreover, surface-bound spacers based on alpha,omega-heterobifunctional PEG amino acids (alphaAm,omegaAc-PEG) also enhanced the benzamidine surface density in comparison to homofunctional PEG diacids (alphaAc,omegaAc-PEG) because of a lower degree of carboxyl inactivation due to PEG 'bridging'. Altogether, the choice of copolymer coatings and the type of PEG spacers were demonstrated to enhance the efficiency of the thrombin scavenging by the covalently immobilized coagulation inhibitor.

Adsorption↗

Thermo-reversible swelling of thin hydrogel films immobilized by low-pressure plasma.

Thin films of graft copolymers consisting of poly(N-isopropylacrylamide) (PNiPAAm) or poly(N,N-diethylacrylamide) (PDEAAm) as polymer backbone and poly(ethyleneglycol) as side chains were cross-linked on fluoropolymer substrates by low-pressure plasma treatment. All immobilized polymers exhibit a lower critical solution temperature between 34 and 40 degrees C. The swelling and collapsing of the hydrogels was examined with temperature-dependent spectroscopic ellipsometry. Two time ranges of swelling were observed: a fast 'dynamic' and a slow 'equilibrium' swelling. The dynamic swelling occurs within minutes or less, whereas the equilibrium swelling needs several days to complete. The surface-bound hydrogels show a shift in the transition temperature toward lower temperatures compared with the behavior in solution. Full reversibility of the dynamic swelling/collapsing was found, but the temperature scan exhibits a hysteresis between heating and cooling cycles. The PNiPAAm-containing hydrogels show a sharper transition compared to the PDEAAm-containing hydrogels, which is almost linear over a wide temperature range.

Journal Article↗

Two-level structured self-adaptive surfaces with reversibly tunable properties.

We report a route to fabricate two-level structured self-adaptive surfaces (SAS) of polymer materials. The first level of structure is built by a rough polymer film that consists of needlelike structures of micrometer size. The second level of structure is formed by the nanoscopic self-assembled domains of a demixed polymer brush irreversibly grafted onto the needles. By exposing the surface to solvents that are selective to one of the components of the brush, we reversibly tune the surface properties. The large-scale surface structure amplifies the response and enables us to control wettability, adhesion, and chemical composition of the surface over a wide range.

Journal Article↗

Low pressure plasma treatment of poly(3-hydroxybutyrate): toward tailored polymer surfaces for tissue engineering scaffolds.

Thin films of poly(3-hydroxybutyrate) were modified by microwave ammonia plasma treatment. The results of the modification were studied by means of contact angle goniometry, ellipsometry, Fourier transform infrared-attenuated total reflection spectroscopy, atomic force microscopy, and X-ray photoelectron spectroscopy. To prove the presence of amino groups on the poly(3-hydroxybutyrate) surface, chemical labeling with 4-trifluoromethyl benzaldehyde was performed before X-ray photoelectron spectroscopy analysis. Under the applied plasma conditions, a hydrophilic surface with a good long-term stability was obtained.

Electron Probe Microanalysis↗

Thermo-responsive PNiPAAm-g-PEG films for controlled cell detachment.

A series of graft copolymers consisting of either poly(N-isopropylacrylamide) (PNiPAAm) or poly(N,N-diethylacrylamide) (PDEAAm) as a thermo-responsive component in the polymer backbone and poly(ethyleneglycol) (PEG) were immobilized as thin films and cross-linked on a fluoropolymer substrate using low-pressure argon plasma treatment. The surface-immobilized hydrogels exhibit a transition from partially collapsed to completely swollen, which is in the range of 32-35 degrees C and corresponds to the lower critical solution temperature of the soluble polymers. The hydrogels were used as cell carriers in culture experiments with L929 mouse fibroblast cells to probe for cell adhesion, proliferation, and temperature-dependent detachment of cell layers. The fibroblast cells adhere, spread, and proliferate on the hydrogel layers at 37 degrees C and become completely detached after reducing the temperature by 3 K. The cell release characteristics were further correlated to the swelling and collapsing behavior of the hydrogel films and the polymer solutions as measured in PBS solution and RPMI cell cultivation medium. It could be shown that, long before the swelling has completed upon temperature reduction, the cells detach. This can be attributed to the large content of PEG present in the hydrogel, which weaken the cell adhesion strength to the hydrogel layers.

Acrylic Resins↗