Search PubMed⌕ Search

Biomedical subjects

Mir S Siadaty

Publications and source records attributed to Mir S Siadaty.

5 recordsLinked to original sources

Papaverine prolongs patency of peripheral arterial catheters in neonates.

OBJECTIVE: To test the hypothesis that the continuous infusion of papaverine-containing solutions in peripheral arterial catheters would decrease the catheter failure rate and increase the functional duration of the catheter in neonates. STUDY DESIGN: In a prospective, randomized, placebo-controlled, masked trial, 82 catheters were placed in 70 neonates in the papaverine group and 98 catheters were placed in 71 neonates in the placebo group. RESULTS: The catheters in the papaverine group remained functional for a significantly longer duration than those in the placebo group. The median (25th%, 75th%) time before catheter failure was 16.6 (9.5, 24.3) days in the papaverine group and 12 days (6.1, 18.2) in the placebo group ( P = .023; Cox proportional hazards model). There was no significant difference in the incidence of intraventricular hemorrhage (IVH) between groups, and there was no evidence of hepatic toxicity. CONCLUSIONS: The continuous infusion of papaverine-containing fluids prolongs the patency of peripheral arterial catheters in neonates. In this small number of infants, we found no difference in the incidence of IVH or hepatic toxicity.

Anticoagulants↗

D-dimer testing for deep venous thrombosis: a metaanalysis.

BACKGROUND: The use of D-dimer assays as a rule-out test for deep venous thrombosis (DVT) is controversial. To clarify this issue we performed a systematic review of the relevant literature. METHODS: We identified eligible studies, using MEDLINE entries from February 1995 through October 2003, supplemented by a review of bibliographies of relevant articles. Studies reporting accuracy evaluations comparing D-dimer test results with lower extremity ultrasound or venography in symptomatic patients with suspected acute DVT were selected for review. Two reviewers critically appraised each study independently according to previously established methodologic standards for diagnostic test research. Those studies judged to be of highest quality were designated Level 1. RESULTS: The 23 Level 1 studies reported data on 21 different D-dimer assays. There was wide variation in assay sensitivity, specificity, and negative predictive values, and major differences in methodology of reviewed studies. A multivariate analysis of assay performance, controlling for sample size, DVT prevalence, reference standard, and patient mix, found few differences among the assays in effect on test performance as measured by diagnostic odds ratio. Increasing prevalence of DVT was associated with poorer test performance (P = 0.01), whereas the choice of venography as the reference standard was associated with better test performance (P <0.005). CONCLUSIONS: Explanations for the wide variation in assay performance include differences in biochemical and technical characteristics of the assays, heterogeneity and small size of patient groups, and bias introduced by choice of reference standards. Assay sensitivity and negative predictive value were frequently <90%, uncharacteristic of a good rule-out test. General use of D-dimer assays as a stand-alone test for the diagnosis of DVT is not supported by the literature.

Biomarkers↗

GeneX Va: VBC open source microarray database and analysis software.

Developed by the Virginia Bioinformatics Consortium (VBC), GeneX Va is an open source, freeware database and bioinformatics analysis software for archiving and analyzing Affymetrix GeneChip data. It provides an integrated framework for management, documentation, and analysis of microarray experiments and data to support a range of users, from individual research laboratories to institutional microarray facilities. GeneX Va also provides web-based access to a PostgreSQL relational database system with a comprehensive security system. Data can be extracted from the database and delivered to interactive or scriptable statistical analysis protocols. The security system allows each investigator to manage their own array data and analysis output files and also provides custom access privileges for other users, groups, and internal/external collaborators. The analysis interface uses "Analysis Trees," an innovative user interface that allows researchers to interactively create a tree-structured flow chart of analysis routines. The latest GeneX Va software is available from and can be freely downloaded at the Sourceforge web site http://va-genex.sourceforge.net. To allow researchers to access the database and analysis capabilities of the GeneX Va system, microarray data from many VBC GeneChip experiments have been deposited into a public section of the GeneX Va system at the University of Virginia. The VBC GeneX Va sites, which include documentation, are at http://genes.med.virginia.edu/ of the University of Virginia and at http://genex.csbc.vcu.edu/ of the Virginia Commonwealth University.

Computer Security↗

Incremental value of combined perfusion and function over perfusion alone by gated SPECT myocardial perfusion imaging for detection of severe three-vessel coronary artery disease.

OBJECTIVES: We hypothesized that combining functional assessment to perfusion enhances the ability of electrocardiographic gating Tc-99m sestamibi single photon emission computed tomography (gated SPECT) myocardial perfusion imaging (MPI) to detect defects in multiple vascular territories in patients with severe three-vessel coronary artery disease (3VD). BACKGROUND: In patients with 3VD, perfusion defects in multiple vascular territories may not always be evident due to globally reduced perfusion. METHODS: Gated SPECT MPIs were interpreted sequentially with perfusion first, followed by combined perfusion/function, in 143 patients with angiographic 3VD and a control group of 112 non-3VD patients. All patients underwent coronary arteriography within one month of MPI. RESULTS: In 3VD patients, combined perfusion/function analysis yielded significantly greater numbers of abnormal segments/patient (6.2 +/- 4.7 vs. 4.1 +/- 2.8, p < 0.001) and more defects in multiple vascular territories (60% vs. 46%, p < 0.05) than perfusion alone. In the control group, there were no differences between the combined perfusion/function and perfusion alone interpretations. Multivariate analysis of 15 different clinical, stress, and scintigraphic variables in all patients revealed age (p < 0.0001) and number of abnormal vascular territories by combined perfusion/function (p < 0.0001) to be the most powerful predictors of 3VD. Addition of functional data to clinical, stress, and perfusion yielded a significant increase in the predictive value of 3VD (global chi-square: 131.7 vs. 89.8, p < 0.00001). Specificity of combined perfusion/function analysis was not lower than perfusion alone (72% vs. 69%, p = NS). CONCLUSIONS; Adjunctive assessment of function with perfusion by gated SPECT MPI enhances the detection of defects in multiple vascular territories in patients with severe 3VD, without adversely affecting its specificity.

Aged↗

The effect of physician feedback and an action checklist on diabetes care measures.

The objective was to evaluate whether physician feedback accompanied by an action checklist improved diabetes care process measures. Eighty-three physicians in an academic general medicine clinic were provided a single feedback report on the most recent date and result of diabetes care measures (glycosylated hemoglobin [A1c], urine microalbumin, serum creatinine, lipid levels, retinal examination) as well as recent diabetes medication refills with calculated dosing and adherence on 789 patients. An educational session regarding the feedback and adherence information was provided. The physicians were asked to complete a checklist accompanying the feedback on each of their patients, indicating requested actions with respect to follow-up, testing, and counseling. The physicians completed 82% of patient checklists, requesting actions consistent with patient needs on the basis of the feedback. Of the physicians, 93% felt the patient information and intervention format to be useful. The odds of urine microalbumin testing, serum creatinine, lipid profile, A1c, and retinal examination increased in the 6 months after the feedback. The increase was sustained at 1 year only for microalbumin and retinal exams. There was no significant change in refill adherence for the group overall after the feedback, although adherence did improve among patients of physicians attending the educational session. No significant change was noted in lipid or A1c levels during the study period. In conclusion, a simple physician feedback tool with action checklist can be both helpful and popular for improving rates of diabetes care guideline adherence. More complex interventions are likely required to improve diabetes outcomes.

Adult↗