Search PubMed⌕ Search

Biomedical subjects

Miles N Wernick

Publications and source records attributed to Miles N Wernick.

6 recordsLinked to original sources

Tomographic image reconstruction based on a content-adaptive mesh model.

In this paper, we explore the use of a content-adaptive mesh model (CAMM) for tomographic image reconstruction. In the proposed framework, the image to be reconstructed is first represented by a mesh model, an efficient image description based on nonuniform sampling. In the CAMM, image samples (represented as mesh nodes) are placed most densely in image regions having fine detail. Tomographic image reconstruction in the mesh domain is performed by maximum-likelihood (ML) or maximum a posteriori (MAP) estimation of the nodal values from the measured data. A CAMM greatly reduces the number of unknown parameters to be determined, leading to improved image quality and reduced computation time. We demonstrated the method in our experiments using simulated gated single photon emission computed tomography (SPECT) cardiac-perfusion images. A channelized Hotelling observer (CHO) was used to evaluate the detectability of perfusion defects in the reconstructed images, a task-based measure of image quality. A minimum description length (MDL) criterion was also used to evaluate the effect of the representation size. In our application, both MDL and CHO suggested that the optimal number of mesh nodes is roughly five to seven times smaller than the number of projection bins. When compared to several commonly used methods for image reconstruction, the proposed approach achieved the best performance, in terms of defect detection and computation time. The research described in this paper establishes a foundation for future development of a (four-dimensional) space-time reconstruction framework for image sequences in which a built-in deformable mesh model is used to track the image motion.

Algorithms↗

A similarity learning approach to content-based image retrieval: application to digital mammography.

In this paper, we describe an approach to content-based retrieval of medical images from a database, and provide a preliminary demonstration of our approach as applied to retrieval of digital mammograms. Content-based image retrieval (CBIR) refers to the retrieval of images from a database using information derived from the images themselves, rather than solely from accompanying text indices. In the medical-imaging context, the ultimate aim of CBIR is to provide radiologists with a diagnostic aid in the form of a display of relevant past cases, along with proven pathology and other suitable information. CBIR may also be useful as a training tool for medical students and residents. The goal of information retrieval is to recall from a database information that is relevant to the user's query. The most challenging aspect of CBIR is the definition of relevance (similarity), which is used to guide the retrieval machine. In this paper, we pursue a new approach, in which similarity is learned from training examples provided by human observers. Specifically, we explore the use of neural networks and support vector machines to predict the user's notion of similarity. Within this framework we propose using a hierarchal learning approach, which consists of a cascade of a binary classifier and a regression module to optimize retrieval effectiveness and efficiency. We also explore how to incorporate online human interaction to achieve relevance feedback in this learning framework. Our experiments are based on a database consisting of 76 mammograms, all of which contain clustered microcalcifications (MCs). Our goal is to retrieve mammogram images containing similar MC clusters to that in a query. The performance of the retrieval system is evaluated using precision-recall curves computed using a cross-validation procedure. Our experimental results demonstrate that: 1) the learning framework can accurately predict the perceptual similarity reported by human observers, thereby serving as a basis for CBIR; 2) the learning-based framework can significantly outperform a simple distance-based similarity metric; 3) the use of the hierarchical two-stage network can improve retrieval performance; and 4) relevance feedback can be effectively incorporated into this learning framework to achieve improvement in retrieval precision based on online interaction with users; and 5) the retrieved images by the network can have predicting value for the disease condition of the query.

Algorithms↗

Multiple-image radiography.

Conventional radiography produces a single image of an object by measuring the attenuation of an x-ray beam passing through it. When imaging weakly absorbing tissues, x-ray attenuation may be a suboptimal signature of disease-related information. In this paper we describe a new phase-sensitive imaging method, called multiple-image radiography (MIR), which is an improvement on a prior technique called diffraction-enhanced imaging (DEI). This paper elaborates on our initial presentation of the idea in Wernick et al (2002 Proc. Int. Symp. Biomed. Imaging pp 129-32). MIR simultaneously produces several images from a set of measurements made with a single x-ray beam. Specifically, MIR yields three images depicting separately the effects of refraction, ultra-small-angle scatter and attenuation by the object. All three images have good contrast, in part because they are virtually immune from degradation due to scatter at higher angles. MIR also yields a very comprehensive object description, consisting of the angular intensity spectrum of a transmitted x-ray beam at every image pixel, within a narrow angular range. Our experiments are based on data acquired using a synchrotron light source; however, in preparation for more practical implementations using conventional x-ray sources, we develop and evaluate algorithms designed for Poisson noise, which is characteristic of photon-limited imaging. The results suggest that MIR is capable of operating at low photon count levels, therefore the method shows promise for use with conventional x-ray sources. The results also show that, in addition to producing new types of object descriptions, MIR produces substantially more accurate images than its predecessor, DEI. MIR results are shown in the form of planar images of a phantom and a biological specimen. A preliminary demonstration of the use of MIR for computed tomography is also presented.

Absorptiometry, Photon↗

An evaluation of methods for detecting brain activations from functional neuroimages.

Brain activation studies based on PET or fMRI seek to explore neuroscience questions by statistically analyzing the acquired images to produce statistical parametric images (SPIs). An increasingly wide range of univariate and multivariate analysis techniques are used to generate SPIs in order to detect mean-signal activations and/or long-range spatial interactions. However, little is known about the comparative detection performance of even simple techniques in finite data sets. Our aims are (1) to empirically compare the detection performance of a range of techniques using simulations of a simple image phantom and receiver operating characteristics (ROC) analysis, and (2) to construct two near-optimal detectors, both generalized likelihood ratio tests as upper performance bounds. We found that for finite samples of (10-100) images, even when the t-test with single-voxel variance estimates (single-voxel t-test) is the "correct" (i.e. unbiased) model for simple local additive signals, better detection performance is obtained using pooled variance estimates or adaptive, multivariate covariance-based detectors. Normalization by voxel-based variance estimates causes significantly decreased detection performance using either single-voxel t-tests or correlation-coefficient thresholding compared to pooled-variance t-tests or covariance thresholding, respectively. Moreover, we found that SVD by itself, or followed by an adaptive Fisher linear discriminant, provides a detector that is (1) more sensitive to mean differences than a single-voxel t-test, (2) insensitive to the large local signal variances detected by covariance thresholding, and (3) much more sensitive to signal correlations than correlation-coefficient thresholding. Adaptive, multivariate covariance-based approaches and pooled-variance t-tests represent promising directions for obtaining optimal signal detection in functional neuroimaging studies.

Brain↗

Digital camera system to perform infrared photography of iris transillumination.

The authors modified a standard digital camera by replacing an internal infrared-blocking filter that allowed photography of iris transillumination defects. Visible and infrared light was produced with a halogen fiberoptic light source that was placed against the inferior eyelid and directed perpendicular to the globe. To obtain images, the camera was mounted to a tabletop tripod placed 3 to 5 in from a chin/headrest apparatus. Images were downloaded onto a personal computer via software and accessories provided by the camera manufacturer. This technique, which is convenient and produces high quality, color images, can highlight details of the normal and pathologic iris. It may have significant utility in clinical research as well as routine clinical care.

Exfoliation Syndrome↗

A support vector machine approach for detection of microcalcifications.

In this paper, we investigate an approach based on support vector machines (SVMs) for detection of microcalcification (MC) clusters in digital mammograms, and propose a successive enhancement learning scheme for improved performance. SVM is a machine-learning method, based on the principle of structural risk minimization, which performs well when applied to data outside the training set. We formulate MC detection as a supervised-learning problem and apply SVM to develop the detection algorithm. We use the SVM to detect at each location in the image whether an MC is present or not. We tested the proposed method using a database of 76 clinical mammograms containing 1120 MCs. We use free-response receiver operating characteristic curves to evaluate detection performance, and compare the proposed algorithm with several existing methods. In our experiments, the proposed SVM framework outperformed all the other methods tested. In particular, a sensitivity as high as 94% was achieved by the SVM method at an error rate of one false-positive cluster per image. The ability of SVM to out perform several well-known methods developed for the widely studied problem of MC detection suggests that SVM is a promising technique for object detection in a medical imaging application.

Algorithms↗