Method for measuring thickness of dielectric films using microdielectric fringe-effect sensors.

A method for noninvasive thickness measurements of dielectric films using fringe-effect (FE) sensors is developed and experimentally validated. The fringing electrical field, created by electrodes microfabricated at the film substrate, depends on the film thickness and dielectric permittivity of the film under test (FUT). The unknown film thickness is estimated by matching the theoretical prediction of thickness-dependent sensor admittance with the measured value. In the case of FE sensors with spatially periodic, interdigitated electrode (IDE) configuration, the admittance prediction is simplified, which allows for the real-time measurements of changing thickness. The developed method can be used to continuously measure the changing dielectric permittivity of the FUT material, which makes it possible to determine the thickness of films of changing dielectric properties, caused by chemical or other transformations. The application of the developed method is demonstrated experimentally by measuring the thickness of silicon nitride film deposited in several increments on the quartz substrate of the IDE sensor. In the expected range of sensor sensitivity, the results show an excellent agreement with the independent thickness measurements.

Journal Article↗

Control of thermal therapies with moving power deposition field.

A thermal therapy feedback control approach to control thermal dose using a moving power deposition field is developed and evaluated using simulations. A normal tissue safety objective is incorporated in the controller design by imposing constraints on temperature elevations at selected normal tissue locations. The proposed control technique consists of two stages. The first stage uses a model-based sliding mode controller that dynamically generates an 'ideal' power deposition profile which is generally unrealizable with available heating modalities. Subsequently, in order to approximately realize this spatially distributed idealized power deposition, a constrained quadratic optimizer is implemented to compute intensities and dwell times for a set of pre-selected power deposition fields created by a scanned focused transducer. The dwell times for various power deposition profiles are dynamically generated online as opposed to the commonly employed a priori-decided heating strategies. Dynamic intensity and trajectory generation safeguards the treatment outcome against modelling uncertainties and unknown disturbances. The controller is designed to enforce simultaneous activation of multiple normal tissue temperature constraints by rapidly switching between various power deposition profiles. The hypothesis behind the controller design is that the simultaneous activation of multiple constraints substantially reduces treatment time without compromising normal tissue safety. The controller performance and robustness with respect to parameter uncertainties is evaluated using simulations. The results demonstrate that the proposed controller can successfully deliver the desired thermal dose to the target while maintaining the temperatures at the user-specified normal tissue locations at or below the maximum allowable values. Although demonstrated for the case of a scanned focused ultrasound transducer, the developed approach can be extended to other heating modalities with moving deposition fields, such as external and interstitial ultrasound phased arrays, multiple radiofrequency needle applicators and microwave antennae.

Feedback↗

MR thermometry-based feedback control of efficacy and safety in minimum-time thermal therapies: phantom and in-vivo evaluations.

The experimental validation of a model-based, thermal therapy control system which automatically and simultaneously achieves the specified efficacy and safety objectives of the treatment is reported. MR-thermometry measurements are used in real-time to control the power of a stationary, focused ultrasound transducer in order to achieve the desired treatment outcome in minimum time without violating the imposed safety constraints. Treatment efficacy is quantified in terms of the thermal dose delivered to the target. Normal tissue safety is ensured by automatically maintaining normal tissue temperature below the imposed limit in the user-specified locations. To reflect hardware limitations, constraints on the maximum applied power are also imposed. At the pretreatment stage, MR imaging and thermometry are used to localize the treatment target and identify thermal and actuation models. The results of phantom and canine experiments demonstrate that spatially-distributed, real-time MR temperature measurements enhance one's ability to robustly achieve the desired treatment outcome in minimum time without violating safety constraints. Post-treatment evaluation of the outcome using T2-weighted images of canine muscle showed good spatial correlation between the sonicated area and thermally damaged tissue.

Animals↗

Physiological control of blood pumps using intrinsic pump parameters: a computer simulation study.

Implantable flow and pressure sensors, used to control rotary blood pumps, are unreliable in the long term. It is, therefore, desirable to develop a physiological control system that depends only on readily available measurements of the intrinsic pump parameters, such as measurements of the pump current, voltage, and speed (in revolutions per minute). A previously proposed DeltaP control method of ventricular assist devices (VADs) requires the implantation of two pressure sensors to measure the pressure difference between the left ventricle and aorta. In this article, we propose a model-based method for estimating DeltaP, which eliminates the need for implantable pressure sensors. The developed estimator consists of the extended Kalman filter in conjunction with the Golay-Savitzky filter. The performance of the combined estimator-VAD controller system was evaluated in computer simulations for a broad range of physical activities and varying cardiac conditions. The results show that there was no appreciable performance degradation of the estimator-controller system compared to the case when DeltaP is measured directly. The proposed approach effectively utilizes a VAD as both a pump and a differential pressure sensor, thus eliminating the need for dedicated implantable pressure and flow sensors. The simulation results show that different pump designs may not be equally effective at playing a dual role of a flow actuator and DeltaP sensor.

Computer Simulation↗

Direct thermal dose control of constrained focused ultrasound treatments: phantom and in vivo evaluation.

The first treatment control system that explicitly and automatically balances the efficacy and safety goals of noninvasive thermal therapies is described, and its performance is evaluated in phantoms and in vivo using ultrasound heating with a fixed, focused transducer. The treatment efficacy is quantified in terms of thermal dose delivered to the target. The developed feedback thermal dose controller has a cascade structure with the main nonlinear dose controller continuously generating the reference temperature trajectory for the secondary, constrained, model predictive temperature controller. The control system ensures thermal safety of the normal tissue by automatically complying with user-specified constraints on the maximum allowable normal tissue temperatures. To reflect hardware limitations and to prevent cavitation, constraints on the maximum transducer power can also be imposed. It is shown that the developed controller can be used to achieve the minimum-time delivery of the desired thermal dose to the target without violating safety constraints, which is a novel and clinically desirable feature. The developed controller is model based, and requires patient- and site-specific models for its operation. These models were obtained during pre-treatment identification experiments. In our implementation, predictive models, internally used by the automatic treatment controller, are dynamically updated each time new temperature measurements become available. The adaptability of internal models safeguards against adverse effects of modelling errors, and ensures robust performance of the control system in the presence of a priori unknown treatment disturbances. The successful validation with two experimental models of considerably different thermal and ultrasound properties suggests the applicability of the developed treatment control system to different anatomical sites.

Animals↗

Standard-independent estimation of dielectric permittivity with microdielectric fringe-effect sensors.

Microdielectric spectroscopy with planar fringe-effect (FE) interdigital sensors is a useful method for noninvasive characterization of the interfacial properties of the materials. Unfortunately, obtaining an accurate dielectric spectrum is difficult because of the complexity of the probing electrical field created by the FE sensor and the contribution of the sensor substrate and stray elements to the overall measurements. Previously, quantitative microdielectric spectroscopy required the calibration of the FE sensor with standard materials that are known to be dielectrically similar to an unknown sample of interest. This limitation complicates the application of microdielectric spectroscopy, particularly in cases where the monitored sample undergoes a transformation that changes its dielectric permittivity. A standard-independent method for quantitative FE microdielectric measurements is proposed in this paper. The developed method is based on comparison of the theoretically predicted admittance of the FE sensor with the sample of known dielectric properties and the measured sensor admittance. Comparison of the theoretical predictions with the admittance measurements reveals the contribution of the unknown stray elements. The measurements with an unknown sample are then adjusted for the strays. The contribution of the sensor substrate to the sensor measurements is removed using the theoretical model derived from the electroquasistatic approximation of Maxwell equations. The dielectric permittivity of the material being tested is calculated by successively solving the system of complex nonlinear equations for each frequency at which the sensor admittance is measured. The developed method is illustrated by applying it to the dielectric measurements of several dissimilar samples. The results are in excellent agreement with those obtained using the gold standard parallel-plate measurement method over the entire range of frequencies.

Journal Article↗

Minimum-time thermal dose control of thermal therapies.

The problem of controlling noninvasive thermal therapies is formulated as the problem of directly controlling thermal dose of the target. To limit the damage to the surrounding normal tissue, the constraints on the peak allowable temperatures in the selected spacial locations are imposed. The developed controller has a cascade structure with a linear, constrained, model predictive temperature controller in the secondary loop. The temperature controller manipulates the intensity of the ultrasound transducer with saturation constraints, which noninvasively heats the spatially distributed target. The main nonlinear thermal dose controller dynamically generates the reference temperature trajectories for the temperature controller. The thermal dose controller is designed to force the treatment progression at either the actuation or temperature constraints, which is required to minimize the treatment time. The developed controller is applicable to high and low-intensity treatments, such as thermal ablation and thermoradiotherapy. The developed approach is tested using computer simulations for a one-dimensional model of a tumor with constraints on the maximum allowable temperature in the normal tissue and a constrained power output of the ultrasound transducer. The simulation results demonstrate that the proposed approach is effective at delivering the desired thermal dose in a near minimum time without violating constraints on the maximum allowable temperature in healthy tissue, despite significant plant-model mismatch introduced during numerical simulation. The results of in vitro and in vivo validation are reported elsewhere.

Algorithms↗

Quantitative measurements of dielectric spectra with microdielectric fringe-effect sensors.

The parallel-plate method is a gold standard for measuring dielectric properties of materials. However, it requires sampling of the material under testing (MUT), which makes it less suitable for real time, dynamic, and in situ measurements. The alternative to the parallel-plate method is to use the microdielectric fringe-effect (FE) sensors, which can be placed inside the process or laboratory equipment to provide rapid, on-line, and noninvasive characterization of the dielectric properties. An additional potential advantage of the FE measurements is the ability to obtain spatially localized and interfacial measurements, which may be important in some applications. Unfortunately, interpretation of the FE sensor measurements is difficult because of the spatial nonuniformity of the electrical excitation field created by the FE sensor and the extraneous contributions from the sensor substrate and unknown stray elements. The objective of this study is to summarize the theoretical basis of the dielectric measurements using planar interdigitated sensors and to use it in the development of a new method for obtaining quantitative measurements with FE sensors. As the first step, the basic correlation between the impedance measurements obtained with the FE sensor and the dielectric properties of the MUT is elucidated. The theoretical results are then used to analyze the contribution of the sensor substrate and unknown stray components to the overall measurements. A novel calibration method to eliminate extraneous contributions is then proposed. The application example demonstrates the application of the developed method to the measurement of the dielectric permittivities of a polydispersed cis-polyisoprene samples. The results are compared with those obtained using the parallel-plate measurements and show excellent agreement. Experimental comparison with the alternative calibration methods is also performed, indicating significant improvement in accuracy of dielectric measurements over a broad range of frequencies.

Journal Article↗

Control strategy for maintaining physiological perfusion with rotary blood pumps.

We present arguments and simulation results in favor of a novel strategy for control of rotary blood pumps. We suggest that physiological perfusion is achieved when the blood pump is controlled to maintain an average reference differential pressure. In the case of rotary left ventricular assist devices, our simulations show that maintaining a constant average pressure difference between the left ventricle and aorta results in physiological perfusion over a wide range of physical activities and clinical cardiac conditions. We simulated rest, light, and strenuous exercise conditions, corresponding to cardiac demands of 4.92, 7.98, and 14.62 L/min, respectively. For different exercise levels, the clinical conditions ranged from normal to failing to asystolic heart. By maintaining a constant pressure difference of 75 mm Hg between the left ventricle and aorta, with either an axial or a centrifugal blood pump, a total cardiac output close to the physiological cardiac demand was achieved, irrespective of the heart condition. The simulations of the transitions between different levels of exercise indicate that with the same reference differential pressure, the proposed approach leads to rapid adaptation of the total cardiac output to physiological levels, while avoiding suction. Comparison with the traditional control strategy of maintaining a reference rotational speed (rpm) of the pump indicates that though the traditional approach has some degree of adaptability, it is only adequate over a narrow range of cardiac demand and clinical conditions of the patient. Our results indicate that the proposed approach is superior to the alternatives in providing an adequate and autonomous adaptation of the total cardiac output over a broad range of exercise conditions (expected when an assist device is used as a destination therapy) and clinical statuses of the native heart (such as further deterioration or recovery of cardiac function), while having the potential to improve the quality of life of patients by reducing the need for monitoring and frequent human intervention. The proposed approach can be clinically implemented using simple controllers, and requires the implantation of two pressure sensors, or estimation of the pressure difference based on other available measurements.

Biomechanical Phenomena↗

Nonlinear controller for ventricular assist devices.

This paper presents the design of a gain-scheduled proportional integral (PI) feedback controller for ventricular assist devices to maintain physiologically motivated perfusion. The selected control objective is to maintain an average differential pressure deltaP between the left ventricle and the aorta. Computer simulations for different pathological conditions, ranging from the normal heart to left heart asystole, and a wide range of physiological scenarios, ranging from rest to strenuous exercise, were used to validate the performance of the controller and the effectiveness of the selected control objective in ensuring physiologically adequate perfusion under different clinical and cardiac demand conditions.

Aorta↗

Model-predictive control of hyperthermia treatments.

A model-predictive controller (MPC) of the thermal dose in hyperthermia cancer treatments has been developed and evaluated using simulations with one-point and one-dimensional models of a tumor. The developed controller is the first effort in: 1) the application of feedback control to pulsed, high-temperature hyperthermia treatments; 2) the direct control of the treatment thermal dose rather than the treatment temperatures; and 3) the application of MPC to hyperthermia treatments. Simulations were performed with different blood flow rates in the tumor and constraints on temperatures in normal tissues. The results demonstrate that 1) thermal dose can be controlled in the presence of plant-model mismatch and 2) constraints on the maximum allowable temperatures in normal tissue and/or the pulsed power magnitude can be directly incorporated into MPC and met while delivering the desired thermal dose to the tumor. For relatively high blood flow rates and low transducer surface intensities--factors that limit the range of temperature variations in the tumor, the linear MPC, obtained by piece-wise linearization of the dose-temperature relationship, provides an adequate performance. For large temperature variations, the development of nonlinear MPC is necessary.

Computer Simulation↗

Modeling and control of a brushless DC axial flow ventricular assist device.

This article presents an integrated model of the human circulatory system that incorporates circulatory support by a brushless DC axial flow ventricular assist device (VAD), and a feedback VAD controller designed to maintain physiologically sufficient perfusion. The developed integrated model combines a network type model of the circulatory system with a nonlinear dynamic model of the brushless DC pump We show that maintaining a reference differential pressure between the left ventricle and aorta leads to adequate perfusion for different pathologic cases, ranging from normal heart to left heart asystole, and widely varying physical activity scenarios from rest to exercise.

Equipment Design↗

Physiologic control of rotary blood pumps: an in vitro study.

Rotary blood pumps (RBPs) are currently being used as a bridge to transplantation as well as for myocardial recovery and destination therapy for patients with heart failure. Physiologic control systems for RBPs that can automatically and autonomously adjust the pump flow to match the physiologic requirement of the patient are needed to reduce human intervention and error, while improving the quality of life. Physiologic control systems for RBPs should ensure adequate perfusion while avoiding inflow occlusion via left ventricular (LV) suction for varying clinical and physical activity conditions. For RBPs used as left ventricular assist devices (LVADs), we hypothesize that maintaining a constant average pressure difference between the pulmonary vein and the aorta (deltaPa) would give rise to a physiologically adequate perfusion while avoiding LV suction. Using a mock circulatory system, we tested the performance of the control strategy of maintaining a constant average deltaPa and compared it with the results obtained when a constant average pump pressure head (deltaP) and constant rpm are maintained. The comparison was made for normal, failing, and asystolic left heart during rest and at light exercise. The deltaPa was maintained at 95 +/- 1 mm Hg for all the scenarios. The results indicate that the deltaPa control strategy maintained or restored the total flow rate to that of the physiologically normal heart during rest (3.8 L/m) and light exercise (5.4 L/m) conditions. The deltaPa approach adapted to changing exercise and clinical conditions better than the constant rpm and constant deltaP control strategies. The deltaPa control strategy requires the implantation of two pressure sensors, which may not be clinically feasible. Sensorless RBP control using the deltaPa algorithm, which can eliminate the failure prone pressure sensors, is being currently investigated.

Blood Circulation↗