Comparison of the pupil card and pupillometer in measuring pupil size.

PURPOSE: To determine the difference in pupil size measured with the Colvard pupillometer in mesopic and scotopic luminance and with the Rosenbaum pupil card in mesopic luminance between 2 examiners. SETTING: Michel Pop Clinics, Montreal, Quebec, Canada. METHODS: Two examiners used the Colvard pupillometer and the Rosenbaum card to measure pupil size in 58 eyes. The Colvard pupillometer was used in mesopic and scotopic light conditions. The Rosenbaum card was used in mesopic luminance only. Pupil size was evaluated with a 1.0 mm interval scale at the nearest half millimeter. RESULTS: For the 3 sets of data, the limits of agreement and coefficient of interrater repeatability were calculated and a 2 x 2 factorial analysis of variance was performed. Because of interexaminer bias, measurements done in mesopic luminance with the Rosenbaum card were not statistically different from those with the Colvard pupillometer in scotopic luminance, although interrater repeatability of the Colvard pupillometer (0.8 mm) was superior to that of the Rosenbaum card (1.3 mm). CONCLUSIONS: Examiner bias was the greatest statistical bias in all sets of measures. Surgeons may want to opt for a "safe" limit of pupil size (ie, 0.5 to 0.8 mm greater than the measured size) when calculating optical zones in refractive surgery. Future devices for pupil measurement should be based on automatic adjustment sizing.

Diagnostic Techniques, Ophthalmological↗

Ultrasound biomicroscopy of the Artisan phakic intraocular lens in hyperopic eyes.

PURPOSE: To study in situ the intraocular position of the Artisan iris-claw intraocular lens (IOL) (model 203) (Ophtec) in phakic hyperopic eyes using ultrasound biomicroscopy (UBM). METHODS: Echograms of the anterior chamber were taken preoperatively and 24 to 317 days postoperatively in 4 eyes implanted with the Artisan IOL (power +4.0 to +6.0 diopters). The preoperative anterior chamber depth (ACD) and the postoperative distance between the IOL and the corneal endothelium (endothelium-optic distance) and between the IOL and the lens were measured. The echograms were assessed for the effect of the IOL on iris tissue. RESULTS: The preoperative ACD ranged from 3.10 to 3.56 mm and the postoperative endothelium-optic distance, from 2.03 to 2.54 mm. The distance between the lens and the posterior surface of the IOL ranged from 0.35 to 0.79 mm. Several UBM echograms showed indentation of iris tissue by the IOL haptics and optic edge, although no pigmentary dispersion was noted. CONCLUSIONS: Adequate space was maintained between the Artisan hyperopic IOL and the corneal endothelium, angle, and crystalline lens. Haptic indentation of the iris, which could lead to pigment erosion, was observed. Preoperative gonioscopy and maintenance of normal intraocular pressure postoperatively suggest the indentation was secondary to inadequate lens vaulting relative to the high natural arch of the iris in hyperopic eyes. Shortening the haptics or increasing the lens vault might resolve this problem.

Anterior Chamber↗

Refractive lens exchange versus iris-claw Artisan phakic intraocular lens for hyperopia.

PURPOSE: To study a paired-match comparison between refractive lens exchange with pseudophakic IOL implant (RLE) and Artisan phakic IOL for high hyperopia. METHODS: Nineteen eyes (12 patients, 20 to 41 years old) with an Artisan phakic IOL (Model 203: 1.00-D increment) for hyperopia from +2.75 to +9.25 D were matched to 19 eyes (15 patients, 26 to 46 yr) with hyperopia from +2.75 to +7.50 D, who had refractive lens exchange (pseudophakic IOL implantation; lenses: 0.50-D increment). Average paired-match difference was 1.13 D and 7.7 years of age. RESULTS: At 1 month after surgery, 84% of refractive lens exchange/pseudophakic IOL eyes and 94% of Artisan phakic IOL eyes had a spherical equivalent refraction within +/- 1.00 D of emmetropia; 58% and 68% of eyes, respectively, were within +/- 0.50 D (P = .97). No eye lost lines of best spectacle-corrected visual acuity (BSCVA) and no significant changes in BSCVA were found in any eye at 1 month after surgery (P = .17). The percentage of eyes with uncorrected visual acuity (UCVA) of 20/40 or better improved from 79% to 89% of eyes at 1 to 2 months after phakic IOL; it remained at 89% to 82% of eyes from 1 to 2 months after refractive lens exchange/ pseudophakic IOL. The coefficient of correlation showed statistically better accuracy (intended vs. achieved refraction; P = .035) for the Artisan phakic IOL (R = 0.83) than for refractive lens exchange/ pseudophakic IOL (R = 0.50). CONCLUSIONS: Spherical equivalent refraction outcome and BSCVA after surgery were similar for both procedures. The Artisan phakic IOL in carefully selected patients provided a better overall outcome for young patients with high hyperopia whose accommodation was preserved, as compared to refractive lens exchange.

Adult↗

Correlation of wavefront data and corneal asphericity with contrast sensitivity after laser in situ keratomileusis for myopia.

PURPOSE: To investigate the relationship between contrast sensitivity (CS), Zernike wavefront aberrations (WFA), and asphericity after laser in situ keratomileusis (LASIK) for myopia. METHODS: LASIK was performed using the Nidek EC-5000 excimer laser with custom aspheric transition zone (CATz) ablations. Total and high order (HO) WFA of 71 eyes (37 patients) undergoing LASIK in March 2003 were measured before and at 1 month postoperatively with the Nidek OPD-Scan aberrometer at a 4-mm pupil entrance; asphericity was measured at 6 mm (Q index). Preoperative and 1 to 3-month postoperative contrast sensitivity were evaluated with the Vector Vision CSV-1000 at 3, 6, 12, and 18 CPD; the Area Under the Log Contrast Sensitivity Function (AULCSF) was calculated. Uncorrected-visual acuity (UCVA) was evaluated. RESULTS: One month after LASIK, CS decreased significantly at 6 CPD and above (P<.05), then returned to normal at 3 months (P=.33). Postoperative AULCSF correlated with patient age (P=.04) but not with total WFA (P=.13), HO WFA (P=.50), or asphericity (P=.22). Postoperative Logmar UCVA correlated with postoperative total and HO WFA (P<.05). Postoperative total WFA correlated with spherical equivalent refraction (P<.0001); HO WFA correlated with Strehl ratio (P=.004) and asphericity (P=.03). The HO WFA increase was 0.065 microm (P<.05) and did not correlate with preoperative refraction (P=.40). Increase in asphericity correlated with corneal refractive change and was predicted by the parabolic Munnerlyn equation (P<.0001). CONCLUSIONS: After LASIK, AULCSF was not dependent on WFA, but mainly on patient age. WFA results correlated well with postoperative spherical equivalent refraction, asphericity, and Strehl ratio. These conclusions support a published hypothesis that postoperative low amount of WFA does not completely fit contrast sensitivity measurements.

Adult↗

Clinical outcomes of CATz versus OPDCAT.

PURPOSE: To compare refractive outcomes, wavefront outcomes, and corneal asphericity indices (Q values) for patients treated with wavefront-guided or topography-guided custom ablations using the NIDEK Advanced Vision Excimer Laser System (NAVEX). METHODS: A total of 196 eyes of 98 patients underwent wavefront-guided or topography-guided LASIK. A contralateral study of 28 eyes of 14 patients who underwent customized aspheric treatment zone (CATz) ablation in one eye and optical path difference customized aspheric treatment (OPDCAT) in the fellow eye comprised one part of the study. The second part of the study was a retrospective review of myopic LASIK using CATz in 84 eyes and LASIK using OPDCAT in 84 eyes. In the CATz-treated eyes, the preoperative mean spherical equivalent refraction was -4.06+/-1.69 diopters (D). In OPDCAT-treated eyes, the preoperative mean spherical equivalent refraction was -3.67+/-2.17 D. RESULTS: In the CATz-treated eyes, 95% of eyes achieved > or = 20/20 best spectacle-corrected visual acuity (BSCVA) with 15% gaining lines of BSCVA. In the OPDCAT-treated eyes, 94.5% of eyes achieved > or = 20/20 vision with 4.5% gaining lines of BSCVA. The difference in lines gained between CATz and OPDCAT in the retrospective component was statistically significant (P<.005). OPDCAT-treated eyes showed a statistically significant worsening in OPD root-mean-square (OPD-RMS), higher order wavefront error, and corneal asphericity (P<.005) compared to preoperative in the retrospective portion of the study. In the contralateral arm of the study, OPD-RMS value was significantly higher (P<.005) in the OPDCAT eyes than the fellow CATz-treated eyes. OPDCAT-treated eyes show a larger change in the Strehl ratio compared to the CATz-treated eyes (P<.005). CONCLUSIONS: The refractive outcomes were excellent and showed no clinically significant difference between CATz and OPDCAT treatments. The higher induction of aberrations with the OPDCAT ablations may be due to the fact that these treatments are based on Zernike polynomials to drive the ablation.

Adult↗