Search PubMed⌕ Search

Biomedical subjects

Michael R Gold

Publications and source records attributed to Michael R Gold.

62 records · Page 4Linked to original sources

Advanced rhythm discrimination for implantable cardioverter defibrillators using electrogram vector timing and correlation.

INTRODUCTION: Discrimination of ventricular and supraventricular arrhythmias remains one of the major challenges for appropriate implantable defibrillator (ICD) therapy delivery. The electrogram vector timing and correlation (VTC) algorithm was developed for such rhythm discrimination. The VTC algorithm differentiates normally conducted supraventricular beats from abnormally conducted ventricular beats by comparing the timing and correlation of rate and shock channel electrograms. METHODS AND RESULTS: Rate and shock channel electrograms of sinus rhythm and induced arrhythmias were collected from 93 patients during ICD placement. The algorithm was developed using data from 50 patients and prospectively tested in a software model with the remaining 43 patients. A sinus rhythm reference was formed by averaging complexes of the shock channel signal aligned by the peak amplitude of the rate channel. Eight features measuring the amplitude and timing of shock channel signal characteristics were extracted from the reference for comparison. When a high-rate rhythm was detected, the VTC algorithm computed the correlation of the arrhythmia complex features with the reference. Rhythms with a sufficient number of uncorrelated beats were classified as ventricular tachycardia (VT). In a dual-chamber implementation, the VTC algorithm is integrated with ventricular and atrial rate comparison (V>A) and stability above an atrial fibrillation rate threshold. The test set consisted of 117 arrhythmias. Dual-chamber sensitivity was 100% (81/81 VT) and specificity was 97% (35/36 supraventricular tachycardia). Single-chamber analysis demonstrated 99% sensitivity and 97% specificity. CONCLUSION: The VTC algorithm demonstrated high sensitivity and specificity in discriminating between ventricular and supraventricular arrhythmias.

Aged↗

Cardiovascular responses to repetitive defibrillation during implantable cardioverter-defibrillator testing.

OBJECTIVE: To study the effects of electrical applications and subsequent postshock hypotension on myocardial performance and vascular tone during implantable cardioverter-defibrillator (ICD) placement. DESIGN: Prospective, blinded, observational investigation. SETTING: Single, university-affiliated institution. PARTICIPANTS: Twenty patients undergoing elective ICD placement and testing under general anesthesia. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Serial measurements were made of hemodynamic variables, left ventricular end-systolic (ESA) and end-diastolic (EDA) areas, fractional-area-of-contraction (FAC), time of hypoperfusion (when mean arterial pressure < or =50 mmHg postshock), and applied conversion energy. Multiple linear regression was performed to determine correlations among collected variables, and repeated measures analysis of variance was used to compare mean values. Minimal changes were detected in mean values of arterial, pulmonary, and central venous pressures; cardiac output; heart rate; and mixed venous saturation during repeated testing. Percentage changes in cardiac index (CI) rose and systemic vascular resistance index (SVRI) fell, however, as the number of shocks increased, reaching significance at the seventh and eighth shocks (v baseline; both p = 0.015). The percentage change in CI was linearly related to hypoperfusion time and accumulated energy (%deltaCI = 1.553 + [0.068 x sigma hypoperfusion time [sec]], r = 0.92, p < 0.001; %deltaCI = 0.326 + [0.125 x sigma Energy [J]], r = 0.94, p < 0.001). The percentage change in SVRI was inversely related to hypoperfusion time and accumulated energy (%deltaSVRI = 2.195 - [0.122 x sigma energy [J]], r = 0.79, p = 0.004; %deltaSVRI = 0.542 - [0.0634 - sigma hypoperfusion time [sec]], r = 0.73, p = 0.01). Echocardiographic EDA, ESA, and FAC were not significantly changed but showed substantial variability. CONCLUSION: Hemodynamic stability was generally well maintained during ICD placement and testing. Increases in CI were associated with concurrent reductions in systemic afterload, rather than enhanced FAC. Increasing postshock hypotension and applied energy were associated with decreases in CI and systemic afterload. Insignificant, but highly variable, changes were noted echocardiographically.

Adult↗

Effect of shock polarity on the efficacy of transthoracic atrial defibrillation.

BACKGROUND: The energy requirement for internal ventricular defibrillation is reduced by reversal of shock polarity. The influence of shock polarity on the efficacy of transthoracic atrial defibrillation is unknown. METHODS: This prospective, randomized study enrolled 110 consecutive patients who were referred for elective cardioversion of persistent atrial fibrillation (AF). The electrodes were placed in the anteroposterior position. The patients were randomized to receive either standard (anterior pad = cathode) or reversed polarity (anterior pad = anode) shocks with a damped sinusoidal monophasic waveform. A step-up protocol was used to estimate the cardioversion threshold. The initial shock energy was 50 J, with subsequent increments to 100, 200, 300, and 360 J in the event of cardioversion failure. RESULTS: Sixty-four percent of the patient population were men, with a mean age of 66 +/- 13 years and a mean duration of AF of 242 +/- 556 days. The overall success rates of cardioversion were 84% for standard polarity and 78% for reversed polarity (P not significant). Among the patients who were successfully cardioverted, the mean atrial defibrillation threshold was 198 +/- 103 J for standard polarity and 212 +/- 107 J for reversed polarity (P not significant). CONCLUSIONS: Reversal of shock polarity does not improve transthoracic cardioversion efficacy with a standard damped sinusoidal monophasic waveform. Alternate strategies should be considered for patients who fail external cardioversion, such as adjunctive pharmacologic treatment, use of a biphasic shock waveform, or internal cardioversion.

Aged↗

T wave alternans for ventricular arrhythmia risk stratification.

Identifying patients at high risk of sudden cardiac death is an important goal, given the magnitude of this problem. In this regard, T wave alternans (TWA) is a heart-rate-dependent measure of arrhythmia vulnerability. The predictive accuracy of this test is maximal at heart rates between 100 and 120 bpm, which are usually achieved with exercise or atrial pacing. TWA has been shown to predict inducibility of ventricular tachycardia with programmed stimulation and to predict spontaneous arrhythmic events. This test has been applied to diverse populations, including patients with coronary artery disease, nonischemic cardiomyopathy, congestive heart failure, and status post implantable defibrillators. Despite these encouraging results, the role of TWA to guide clinical therapy still must be better elucidated.

Arrhythmias, Cardiac↗

The direct recruitment of BLNK to immunoglobulin alpha couples the B-cell antigen receptor to distal signaling pathways.

Following B-cell antigen receptor (BCR) ligation, the cytoplasmic domains of immunoglobulin alpha (Ig alpha) and Ig beta recruit Syk to initiate signaling cascades. The coupling of Syk to several distal substrates requires linker protein BLNK. However, the mechanism by which BLNK is recruited to the BCR is unknown. Using chimeric receptors with wild-type and mutant Ig alpha cytoplasmic tails we show that the non-immunoreceptor tyrosine-based activation motif (ITAM) tyrosines, Y176 and Y204, are required to activate BLNK-dependent pathways. Subsequent analysis demonstrated that BLNK bound directly to phospho-Y204 and that fusing BLNK to mutated Ig alpha reconstituted downstream signaling events. Moreover, ligation of the endogenous BCR induced Y204 phosphorylation and BLNK recruitment. These data demonstrate that the non-ITAM tyrosines of Ig alpha couple Syk activation to BLNK-dependent pathways.

Adaptor Proteins, Signal Transducing↗

The influence of gender on arrhythmias.

It is becoming increasingly apparent that there are important gender differences in normal cardiac physiology. These, in turn, could be associated with differences in the type and severity of cardiac arrhythmias. Women have higher resting heart rates than men, probably as a result of a combination of autonomic and intrinsic factors. The clinical significance of this observation is unclear at the present time. Women have a lower incidence of sudden cardiac death, which could be related to the delayed onset of coronary artery disease in women, presumably as a result of the protective effects of female hormones during gestational years. In survivors of sudden cardiac death, there are major gender differences, with fewer women having underlying coronary artery disease and a greater percentage of women having structurally normal hearts. QT interval prolongation and Torsade de Pointes are more common in women, probably on the basis of differences in ion channels between genders. Women appear especially susceptible to Torsades from QT-prolonging drugs such as quinidine or tricyclic antidepressant medications. The mechanisms of paroxysmal supraventricular tachycardia differ between the genders, although therapy seems to be equally efficacious in men and women. Lastly, atrial fibrillation is considerably more common in men. There is also some evidence that it is better tolerated by men.

Arrhythmias, Cardiac↗