Seasonal variation of mortality in the Antiarrhythmics Versus Implantable Defibrillators (AVID) study registry.

OBJECTIVES: We postulated that the pattern of death would be nonrandom with respect to temporal variables. BACKGROUND: Previous studies have demonstrated increased sudden death is associated with periods of relative stress, and overall mortality is associated with temporal variables. METHODS: In the Antiarrhythmics Versus Implantable Defibrillators (AVID) registry, vital status was obtained for 4,450 patients (who had a recent episode of sustained ventricular arrhythmias or unexplained syncope and inducible ventricular tachycardia) through the National Death Index Service as of December 31, 1997 (follow-up 25.5 +/- 13.7 months). RESULTS: Mortality was not associated with the day of the week or with holidays but was associated with season (P = .033). Seasonal variation was present both in northern and southern sites. Mortality was higher during the winter months compared to the remaining months (111.2% in winter vs 96.5% in other months, P = .036). In addition, increased mortality was associated with a high-risk season variable defined (prior to evaluation of treatment arm associations) as spring in the north and winter in the south (P < .001). The hazard ratio for death associated with this "high-risk season" measured 1.25 (P = .001) compared to the other seasons in each region. A test of interaction between "high-risk" season and implantable cardioverter-defibrillator (ICD) status suggested that the group with ICDs experienced reduced mortality during the "high-risk season" compared to the group without ICDs (P = .047). CONCLUSIONS: Mortality was higher in the winter months and in the respective regional "high-risk" seasons. Furthermore, seasonal variation in mortality may have been due to variation in sudden arrhythmic death, and associated increases in mortality were reduced by ICD therapy.

Anti-Arrhythmia Agents↗

Enhanced detection of arrhythmia vulnerability using T wave alternans, left ventricular ejection fraction, and programmed ventricular stimulation: a prospective study in subjects with chronic ischemic heart disease.

INTRODUCTION: In previous studies, the prognostic value of T wave alternans (TWA) was similar to that of programmed ventricular stimulation (PVS). However, presently it is unclear if TWA and PVS identify the same patients or provide complementary risk stratification information. In addition, the effects of left ventricular ejection fraction (LVEF) on the prognostic value of TWA are unknown. The aim of this study was to determine if combined assessment of TWA, LVEF, and PVS improves arrhythmia risk stratification. METHODS AND RESULTS: This was a prospective study of 144 patients with coronary artery disease and LVEF < or =40% who were referred for PVS for standard clinical indications. The endpoint was the combined incidence of death, sustained ventricular arrhythmias, and appropriate implantable cardioverter defibrillator (ICD) therapy. TWA (hazard ratio 2.2, P = 0.03) and PVS (hazard ratio 1.9, P = 0.05) both were significant predictors of endpoint events, and TWA was the only independent predictor. LVEF markedly influenced the prognostic value of TWA, which was a potent predictor of events in subjects with LVEF between 30% and 40% (event rates: TWA+ 36%, TWA- 0%, P = 0.001) but did not predict events in subjects with LVEF <30% (hazard ratio 1.1, P > 0.5). PVS successfully identified additional low-risk patients within the cohort with negative or indeterminate TWA results (hazard ratio 4.7, P = 0.015) but did not provide incremental prognostic information for TWA+ patients (hazard ratio 0.9, P > 0.5). CONCLUSION: The combined use of TWA, LVEF, and PVS is a promising new approach to arrhythmia risk stratification that permits identification of high-risk and very-low-risk patients.

Aged↗

Optimization of atrial defibrillation with a dual-coil, active pectoral lead system.

INTRODUCTION: Atrial defibrillation can be achieved with standard implantable cardioverter defibrillator (ICD) leads, but the optimal shocking configuration is unknown. The objective of this prospective study was to compare atrial defibrillation thresholds (DFTs) with three shocking configurations that are available with standard ICD leads. METHODS AND RESULTS: This study was a prospective, randomized, paired comparison of shocking configurations on atrial DFTs in 58 patients. The lead system evaluated was a transvenous defibrillation lead with coils in the superior vena cava (SVC) and right ventricular apex (RV) and a left pectoral pulse generator emulator (Can). In the first 33 patients, atrial DFT was measured with the ventricular triad (RV --> SVC + Can) and unipolar (RV --> Can) shocking pathways. In the next 25 patients, atrial DFT was measured with the ventricular triad and the proximal triad (SVC --> RV + Can) configurations. Delivered energy at DFT was significantly lower with the ventricular triad compared to the unipolar configuration (4.7 +/- 3.7 J vs 10.1 +/- 9.5 J, P < 0.001). Peak voltage and shock impedance also were significantly reduced (P < 0.001). There was no significant difference in DFT energy when the ventricular triad and proximal triad shocking configurations were compared (3.6 +/- 3.0 J vs 3.4 +/- 2.9 J for ventricular and proximal triad, respectively, P = NS). Although shock impedance was reduced by 13% with the proximal triad (P < 0.001), this effect was offset by an increased current requirement (10%). CONCLUSION: The ventricular triad is equivalent or superior to other possible shocking pathways for atrial defibrillation afforded by a dual-coil, active pectoral lead system. Because the ventricular triad is also the most efficacious shocking pathway for ventricular defibrillation, this pathway should be preferred for combined atrial and ventricular defibrillators.

Aged↗

Comparison of step-down and binary search algorithms for determination of defibrillation threshold in humans.

Determination of DFT is an integral part of ICD implantation. Two commonly used methods of DFT determination, the step-down method and the binary search method, were compared in 44 patients undergoing ICD testing for standard clinical indications. The step-down protocol used an initial shock of 18 J. The binary search method began with a shock energy of 9 J and successive shock energies were increased or decreased depending on the success of the previous shock. The DFT was defined as the lowest energy that successfully terminated ventricular fibrillation. The binary search method has the advantage of requiring a predetermined number of shocks, but some have questioned its accuracy. The study found that (mean) DFT obtained by the step-down method was 8.2 +/- 5.0, whereas by the binary search method DFT was 8.1 +/- 0.7 J, P = NS. DFT differed by no more than one step between methods in 32 (71%) of patients. The number of shocks required to determine DFT by the step-down method was 4.6 +/- 1.4, whereas by definition, the binary search method always required three shocks. In conclusion, the binary search method is preferable because it is of comparable efficacy and requires fewer shocks.

Aged↗

The Rap GTPases regulate integrin-mediated adhesion, cell spreading, actin polymerization, and Pyk2 tyrosine phosphorylation in B lymphocytes.

Integrin-mediated adhesion plays an important role in B cell development and activation. Signaling initiated by antigens, chemokines, or phorbol esters can rapidly convert integrins to an activated adhesion-competent state. The binding of integrins to their ligands can then induce actin-dependent cell spreading, which can facilitate cell-cell adhesion or cell migration on extracellular matrices. The signaling pathways involved in integrin activation and post-adhesion events in B cells are not completely understood. We have previously shown that anti-Ig antibodies, the chemokine stromal cell-derived factor-1 (SDF-1; CXCL12), and phorbol esters activate the Rap1 and Rap2 GTPases in B cells and that Rap activation is essential for SDF-1-induced B cell migration (McLeod, S. J., Li, A. H. Y., Lee, R. L., Burgess, A. E., and Gold, M. R. (2002) J. Immunol. 169, 1365-1371; Christian, S. L., Lee, R. L., McLeod, S. J., Burgess, A. E., Li, A. H. Y., Dang-Lawson, M., Lin, K. B. L., and Gold, M. R. (2003) J. Biol. Chem. 278, 41756-41767). We show here that preventing Rap activation by expressing Rap-specific GTPase-activating protein II (RapGAPII) significantly decreased lymphocyte function-associated antigen-1- and alpha(4) integrin-dependent binding of murine B cell lines to purified adhesion molecules and to other cells. Conversely, augmenting Rap activation by expressing a constitutively active form of Rap2 enhanced B cell adhesion, showing for the first time that Rap2 can promote integrin activation. We also show that blocking Rap activation inhibited anti-Ig-induced cell spreading and phorbol ester-induced actin polymerization as well as anti-Ig- and SDF-1-induced phosphorylation of Pyk2, a tyrosine kinase involved in morphological changes and chemokine-induced B cell migration. Thus, the Rap GTPases regulate integrin-mediated B cell adhesion as well as processes that control B cell morphology and migration.

Actins↗

Activation of the Rap GTPases in B lymphocytes modulates B cell antigen receptor-induced activation of Akt but has no effect on MAPK activation.

Signaling by the B cell antigen receptor (BCR) activates the Rap1 and Rap2 GTPases, putative antagonists of Ras-mediated signaling. Because Ras can activate the Raf-1/ERK pathway and the phosphatidylinositol 3-kinase (PI3K)/Akt pathway, we asked whether Rap activation limits the ability of the BCR to signal via these pathways. To do this, we blocked the activation of endogenous Rap1 and Rap2 by expressing the Rap-specific GTPase-activating protein RapGAPII. Preventing Rap activation had no effect on BCR-induced activation of ERK. In contrast, BCR-induced phosphorylation of Akt on critical activating sites was increased 2- to 3-fold when Rap activation was blocked. Preventing Rap activation also increased the ability of the BCR to stimulate Akt-dependent phosphorylation of the FKHR transcription factor on negative regulatory sites and decreased the levels of p27Kip1, a pro-apoptotic factor whose transcription is enhanced by FKHR. Moreover, preventing Rap activation reduced BCR-induced cell death in the WEHI-231 B cell line. Thus activation of endogenous Rap by the BCR limits BCR-induced activation of the PI3K/Akt pathway, opposes the subsequent inhibition of the FKHR/p27Kip1 pro-apoptotic module, and enhances BCR-induced cell death. Consistent with the idea that Rap-GTP is a negative regulator of the PI3K/Akt pathway, expressing constitutively active Rap2 (Rap2V12) reduced BCR-induced phosphorylation of Akt and FKHR. Finally, our finding that Rap2V12 can bind PI3K and inhibit its activity in a manner that depends upon BCR engagement provides a potential mechanism by which Rap-GTP limits activation of the PI3K/Akt pathway, a central regulator of B cell growth and survival.

Animals↗

Effect of an implantable cardioverter defibrillator with atrial detection and shock therapies on patient-perceived, health-related quality of life.

BACKGROUND: This study used a device (DDD implantable cardioverter defibrillator [ICD]) capable of delivering pacing and shock therapies to restore normal sinus rhythm in patients with atrial tachycardias or atrial fibrillation (AF). The purpose of this study was to assess the effect of the device on patient-perceived, health-related quality of life (QOL). METHODS: The DDD ICD was implanted in 267 patients with drug refractory, symptomatic AF from 45 centers across Europe, the United States, and Canada. Patients completed self-reported, validated QOL assessments at baseline and at 3- and 6-month follow-up visits (The Medical Outcomes Short Form 36 [SF-36] and the Symptom Checklist [SCL]). RESULTS: The mean age of the study group was 62 +/- 12 years, and 73% of the patients were male. A total of 150 patients completed SF-36 assessments, and 138 patients completed SCL assessments at all 3 times. Baseline scores were more impaired (P <.05) on most SF-36 scales compared with norms for a general population, but were similar to a comparison group of patients with AF who were referred to tertiary care centers. The role-physical, physical functioning, vitality, mental health, and social functioning scales all improved significantly with time (all P <.04). Similarly, symptom frequency and severity (SCL) also improved significantly from baseline to 6 months (both P <.01). Shock therapy was delivered in 86 of the 150 patients (57%) with complete SF-36 evaluations. There was no evidence that receiving shocks decreased the relative improvement in QOL associated with implantation of the device. CONCLUSIONS: In a 6-month period, QOL improves after implantation of a DDD ICD with atrial shock and pacing therapies. These improvements were not attenuated by receipt of shocks.

Atrial Fibrillation↗

Effect of shock polarity on defibrillation thresholds with a hybrid patch-coil lead system.

INTRODUCTION: Understanding the factors that affect defibrillation thresholds (DFTs) has important implications both for optimization of defibrillation efficacy and for the design of new lead systems. The objective of this prospective study was to evaluate the effect of shock polarity on defibrillation efficacy at the time of routine pulse generator replacement in patients with a hybrid patch-coil lead system. METHODS: Each patient underwent 4 assessments of DFT: monophasic or biphasic shock with standard or reversed polarity, with the order of testing with respect to polarity randomized. In standard polarity, the right atrial coil is the anode and the left ventricular patch is the cathode. RESULTS: The study population of 30 patients was 80% men with a mean age of 65 +/- 9 years and a mean left ventricular ejection fraction of 33 +/- 12%. There was a significant 21% decrease in the mean monophasic DFT with reversed polarity shocks (13.1 +/- 5.9 J vs. 16.6 +/- 6.5 J, p < 0.01). Reversal of shock polarity did not have a significant effect on the mean biphasic DFT (8.0 +/- 4.8 J vs. 8.5 +/- 4.3 J for reversed and standard polarity respectively, p = NS). However, when an elevated biphasic DFT (>or=15 J) was present in either standard or reversed polarity, a significant decrease in DFT was observed when the opposite polarity was used (16.7 +/- 2.5 J vs. 9.1 +/- 2.7 J, n = 9, p < 0.0001). CONCLUSION: Reversal of shock polarity markedly improves monophasic DFTs with the patch-coil lead configuration. The DFT should be determined with both shock polarities to optimize defibrillation efficacy for patients with high biphasic DFTs (>or=15 J).

Aged↗

Effectiveness of rapid atrial pacing for termination of drug refractory atrial fibrillation: results of a dual chamber implantable cardioverter defibrillator trial.

There is increasing interest in the use of an implantable cardioverter defibrillator (ICD) to manage atrial tachyarrhythmias. Although device-based shock therapy is highly effective in terminating persistent atrial tachyarrhythmias, atrial overdrive pacing may also be useful, particularly when this therapy is applied early after the onset of an arrhythmia. A dual-chamber ICD (Medtronic 7250 Jewel AF(R)) has been studied in 267 patients with drug-refractory symptomatic AF. The patients were enrolled as part of multicenter clinical trial to evaluate the safety and efficacy of the device to manage atrial tachyarrhythmias in the absence of a standard ventricular ICD indication. The device discriminates atrial tachycardia (AT) from atrial fibrillation (AF) based on cycle length and regularity, and employs multiple methods of atrial overdrive pacing as well as shocks to terminate tachyarrhythmia episodes. Patients were followed for an average of 15.8 +/- 9.3 months. A majority (63%) of patients presented with a history of persistent AF and 34% presented with a history of paroxysmal AF. The pacing therapies terminated 54% of AT episodes and 27% of AF episodes. In patients with persistent AF, 75% of the AT/AF episodes that were successfully terminated by pacing lasted <or=9 minutes. When the pacing therapies failed, episodes lasted for several hours and 50% of the episodes received at least one shock. The results of this trial suggest that pace-termination plays an important role in device-based management of atrial tachyarrhythmias. It is estimated that early pace-termination of AT/AF episodes may reduce the need for device-based shocks among patients with persistent AF by about half.

Algorithms↗

Safety of a single successful conversion of ventricular fibrillation before the implantation of cardioverter defibrillators.

UNLABELLED: Multiple successful conversions of ventricular fibrillation (VF) at 10 J below the maximum output of implantable cardioverter defibrillator (ICD) have been recommended as a minimum device implantation criterion. This recommendation is based on the probabilistic properties of defibrillation that necessitates multiple shocks to establish an adequate safety margin for the conversion of subsequent spontaneous arrhythmias. We hypothesized that a single successful shock at a 14 J may suffice. METHODS AND RESULTS: The Low Energy Safety Study (LESS) enrolled 720 patients undergoing initial ICD implantation with a dual-coil transvenous lead and active pulse generator. At implant, an enhanced defibrillation threshold (DFT++) was determined by a rigorous protocol beginning at 14 J, and requiring at least 4 shocks. Fifty percent of all patients were then randomized to full output shock energy and the conversion rates for spontaneous ventricular tachyarrhythmias at rates > 200 beats/min were measured. There were 318 patients randomized to 31 J, of whom 254 were successfully defibrillated by an initial 14 J shock. During a mean follow-up of 24 +/- 12 months, 112 spontaneous VF episodes occurred in 31 patients. The combined conversion success of the first and second shock (when needed) did not differ between the subgroup of patients who were successfully defibrillated by an initial 14 J shock, regardless of the results of additional testing, and the whole cohort who underwent more systematic testing (97% vs 97%). All spontaneous episodes of VF were successfully treated during long-term follow-up. CONCLUSIONS: A first successful shock of 14 J may be a sufficient endpoint to allow the implantation of ICDs with the Triad lead configuration, when programming all shocks to 31 J.

Aged↗

Distal right ventricular coil position reduces defibrillation thresholds.

UNLABELLED: Distal RV Coil Position Reduces DFTs. INTRODUCTION: Understanding the factors that affect defibrillation thresholds (DFTs) has important implications both for optimization of defibrillation efficacy and for the design of new transvenous leads. The aim of this prospective study was to test the hypothesis that defibrillation efficacy is improved with the right ventricular (RV) coil in a distal position compared with a more proximal RV coil position. METHODS AND RESULTS: A novel defibrillation lead with three adjacent RV defibrillation coils (distal 0.8 cm, middle 3.7 cm, proximal 0.8 cm) was used for this study to permit comparison of DFTs with the proximal and distal RV coil positions without lead repositioning. In the distal RV configuration, the distal and middle RV coils were connected electrically as the anode for defibrillation. In the proximal RV configuration, the middle and proximal coils were the anode. A superior vena cava (SVC) coil and active can were connected electrically as the cathode (reversed polarity, RV-->Can+SVC). In each patient, the DFT was measured twice using a binary search protocol with the distal RV and proximal RV configurations, with the order of testing randomized. The study cohort consisted of 31 subjects (mean age 65 +/- 12 years, mean left ventricular ejection fraction 30% +/- 16%, 81% male predominance). The mean delivered energy (8.2 +/- 5.3 J vs 11.2 +/- 6.1 J), leading-edge voltage (335 +/- 109 V vs 393 +/- 118 V), and peak current (11.6 +/- 5.2 A vs 14.9 +/- 7.3 A) at DFT all were significantly lower with the distal RV configuration compared to the proximal RV configuration (P < 0.01 for all comparisons). CONCLUSION: DFTs are significantly reduced with the distal RV configuration compared to the proximal RV configuration. Defibrillation leads should be designed with the shortest tip to coil distance that can be achieved without compromising ventricular fibrillation sensing.

Aged↗

T wave alternans for ventricular arrhythmia risk stratification.

Sudden cardiac death remains one of the leading causes of death in western societies. Accordingly, the ability to identify patients at high risk of sudden cardiac death is important so that appropriate treatments can be used efficiently. Recently, T wave alternans (TWA) has emerged as a promising new test for such risk stratification. TWA is a heart rate-dependent measure of arrhythmia vulnerability, with maximal predictive accuracy at sustained, regular heart rates of 100 to 120 bpm. In the clinical setting, these conditions may be achieved by either exercise or atrial pacing. TWA has been shown to predict inducibility of ventricular tachycardia with programmed stimulation and also spontaneous arrhythmic events. TWA has been successfully applied to diverse populations, including patients with coronary artery disease, nonischemic cardiomyopathy, congestive heart failure, and implantable defibrillators. Despite these encouraging results, the role of TWA to guide clinical therapy still needs to be elucidated better.

Anti-Arrhythmia Agents↗