Search PubMed⌕ Search

Biomedical subjects

Michael O Sweeney

Publications and source records attributed to Michael O Sweeney.

At least 19 recordsLinked to original sources

A new paradigm for physiologic ventricular pacing.

Clinical trials in patients with pacemakers for sinus node dysfunction or atrioventricular block (AVB) and implantable cardioverter-defibrillators provide increasing evidence showing that desynchronization of ventricular electrical activation and contraction, induced by conventional right ventricular apex (RVA) pacing, is a serious threat for long-term cardiac morbidity and mortality. The risk of heart failure is increased even in hearts with initially normal pump function and in case of part-time ventricular pacing. These epidemiologic data fit with knowledge from decades of pathophysiological research, indicating that right ventricular (RV) pacing creates abnormal contraction, reduced pump function, hypertrophy, and ultrastructural abnormalities. This paper presents a new paradigm that aims to tailor ventricular pacing to the individual patient to achieve a way of pacing that is as physiologic as possible. In patients without AVB and no intraventricular conduction abnormalities, ventricular pacing should be avoided as much as possible, using atrial-based pacing. In patients with AVB, alternate single-site RV or left ventricular pacing or biventricular pacing may be superior to RVA pacing. Efforts to optimize the pacing mode or site should be greater in patients with a longer expected duration of pacing, poorer cardiac function, and larger mechanical asynchrony. Awareness of the problem of desynchronization should also lead to more regular monitoring of cardiac pump function and mechanical asynchrony in any patient with ventricular pacing.

Animals↗

QRS duration does not predict occurrence of ventricular tachyarrhythmias in patients with implanted cardioverter-defibrillators.

OBJECTIVES: The aim of this study was to determine whether QRS duration (QRSd) correlates with occurrence of ventricular arrhythmia in patients with coronary disease (CAD) receiving implantable cardioverter-defibrillators (ICDs). BACKGROUND: A QRSd measured on a standard electrocardiograph (ECG) correlates with total mortality risk in CAD patients at high risk for sudden death; however, the relationship between QRSd and risk of ventricular tachyarrhythmias (ventricular tachycardia/ventricular fibrillation [VT/VF]) is unclear. METHODS: PainFREE Rx II was a randomized trial, comparing efficacy of antitachycardia pacing versus shock therapy for VT/VF in patients receiving ICDs. We retrospectively correlated the QRSd and specific ECG conduction abnormalities on the 12-lead ECG at study entry with occurrence of VT/VF in 431 patients with CAD enrolled in the trial. RESULTS: The QRSd was < or =120 ms in 291 of 431 (68%) patients. Left bundle branch block (LBBB) was present in 65 patients, right bundle branch block (RBBB) in 48 patients, and nonspecific intraventricular conduction delay (IVCD) was present in 124 patients. Over 12 months' follow-up, VT/VF occurred in 95 (22%) patients (22% of patients with QRSd < or =120 ms vs. 23% of patients with QRSd >120 ms, p = NS). Patients with LBBB were less likely to experience at least one VT/VF episode than patients with QRSd <120 ms. Patients with RBBB and nonspecific IVCD did not differ from patients with narrow QRS complexes with regard to occurrence of tachycardias. CONCLUSIONS: The QRSd and ECG conduction abnormalities are not useful to predict ICD benefit in patients having the characteristics of our study population. The utility of QRSd to predict VT/VF events in patients with CAD requires further prospective evaluation.

Aged↗

Appropriate and inappropriate ventricular therapies, quality of life, and mortality among primary and secondary prevention implantable cardioverter defibrillator patients: results from the Pacing Fast VT REduces Shock ThErapies (PainFREE Rx II) trial.

BACKGROUND: Implantable cardioverter defibrillators (ICDs) reduce mortality in primary and secondary prevention. Quality of life, mortality, appropriate therapies for specific ventricular rhythms, and inappropriate therapies for supraventricular tachycardia (SVT) were compared among 582 patients (primary prevention=248; secondary prevention=334) in PainFREE Rx II, a 634-patient prospective, randomized study of antitachycardia pacing or shocks for fast ventricular tachycardia (FVT). METHODS AND RESULTS: ICDs were programmed identically with 3 zones (ventricular tachycardia [VT] <188 bpm; FVT=188 to 250 bpm; ventricular fibrillation [VF] >250 bpm) but randomized to antitachycardia pacing or shock as initial therapy for FVT. All treated episodes with electrograms were adjudicated. Primary prevention patients had lower ejection fractions and more coronary artery disease. beta-Blocker use, antiarrhythmic drug use, and follow-up duration were similar. Over 11+/-3 months, 1563 treated episodes were classified as VT (n=740), FVT (n=350), VF (n=77), and SVT (n=396). The distribution of VT, FVT, and VF was not different between primary and secondary prevention patients (respectively, VT 52% versus 54%, FVT 35% versus 35%, and VF 14% versus 10%). More secondary prevention patients had appropriate therapies (26% versus 18%, P=0.02), but among these patients, the median number of episodes per patient was similar. Inappropriate therapies occurred in 15% of both groups and accounted for similar proportions of all detected and treated episodes (46% in primary prevention patients versus 34% in secondary prevention patients, P=0.09). Quality of life improved modestly in both groups, and mortality was similar. CONCLUSIONS: Primary prevention patients are slightly less likely to have appropriate therapies than secondary prevention patients, but episode density is similar among patients with appropriate therapies. SVT resulted in more than one third of therapies in both groups, but quality of life and mortality were similar.

Aged↗

Association of prolonged QRS duration with death in a clinical trial of pacemaker therapy for sinus node dysfunction.

BACKGROUND: Prolonged QRS duration (QRSd) is an important prognostic indicator for death and heart failure hospitalization in patients with systolic heart failure. The relationship of baseline QRSd to death and heart failure hospitalization in patients with sinus node dysfunction who require pacemaker therapy is unknown. METHODS AND RESULTS: Baseline QRSd from 12-lead ECGs before pacemaker implantation were analyzed in the Mode Selection Trial (MOST), a 6-year, 2010-patient randomized trial of dual-chamber versus ventricular pacing in sinus node dysfunction. Baseline QRSd was > or =120 ms in 23.4% of patients and was associated with older age, lower ejection fraction, cardiomyopathy, and prior heart failure. Adjusted Cox models demonstrated baseline QRSd > or =120 ms was a strong independent predictor of death (hazard ratio [95% CI] 1.35 [1.07, 1.70], P=0.010) but not heart failure hospitalization. The risk of death increased with increased QRSd from 60 to 120 ms (P=0.002 and hazard ratio [95% CI] 1.14 [1.05, 1.23] for 10-ms increase in this range) after adjustment for other death predictors. CONCLUSIONS: Baseline QRSd > or =120 ms was associated with increased risk of death during pacemaker therapy for sinus node dysfunction.

Aged↗

Heart failure hospitalization is more common in pacemaker patients with sinus node dysfunction and a prolonged paced QRS duration.

OBJECTIVES: The purpose of this study was to determine whether a prolonged paced QRS duration increases the risk of cardiac dysfunction. BACKGROUND: Right ventricular apical pacing mimics left bundle branch block, results in a prolonged QRS duration of variable duration, and causes ventricular desynchronization. METHODS: In the Mode Selection Trial (MOST), QRS duration was measured in patients who had at least one paced ventricular complex recorded on 12-lead ECG within 3 months of enrollment (early) and after 9 months (late). Clinical endpoints including heart failure hospitalization, mortality, and atrial fibrillation were analyzed. A total of 1,026 patients were included in the analysis. Median age was 75 years (25th, 75th percentiles = 69, 80) and median ejection fraction prior to implant was 55% (45, 60). The cumulative percent ventricular pacing (DDDR and VVIR) was 81% over a median follow-up of 33 months. During period, 123 patients had heart failure hospitalization, 197 died, and 261 patients had atrial fibrillation. RESULTS: Cox proportional hazards models demonstrated that paced QRS duration was a strong predictor of heart failure hospitalization (hazard ratio 1.15; 95% confidence interval 1.07,1.23) for each 10-ms increase in paced QRS duration (P = .001). The increased risk was unaffected by adjustment for other known predictors of heart failure hospitalization in the study. Paced QRS duration was not significant for mortality (P = .41) or atrial fibrillation (P = .20) when baseline QRS duration and other predictors were included. CONCLUSIONS: Paced QRS duration is a significant, independent predictor of heart failure hospitalization in patients with sinus node dysfunction. A very long paced QRS duration is associated with increased heart failure hospitalization.

Aged↗

Wide right.

Explore the source record for details and available documents.

Bundle-Branch Block↗

Multicenter, prospective, randomized safety and efficacy study of a new atrial-based managed ventricular pacing mode (MVP) in dual chamber ICDs.

BACKGROUND: Ventricular desynchronization caused by right ventricular pacing may impair ventricular function and increase risk of heart failure (CHF), atrial fibrillation (AF), and death. Conventional DDD/R mode often results in high cumulative percentage ventricular pacing (Cum%VP). We hypothesized that a new managed ventricular pacing mode (MVP) would safely provide AAI/R pacing with ventricular monitoring and DDD/R during AV block (AVB) and reduce Cum%VP compared to DDD/R. METHODS: MVP RAMware was downloaded in 181 patients with Marquis DR ICDs. Patients were initially randomized to either MVP or DDD/R for 1 month, then crossed over to the opposite mode for 1 month. ICD diagnostics were analyzed for cumulative percentage atrial pacing (Cum%AP), Cum%VP, and duration of DDD/R pacing for spontaneous AVB. RESULTS: Baseline characteristics included age 66 +/- 12 years, EF 36 +/- 14%, and NYHA Class II-III 36%. Baseline PR interval was 190 +/- 53 msec and programmed AV intervals (DDD/R) were 216 +/- 50 (paced)/189 +/- 53 (sensed) msec. Mean Cum%VP was significantly lower in MVP versus DDD/R (4.1 +/- 16.3 vs 73.8 +/- 32.5, P < 0.0001). The median absolute and relative reductions in Cum%VP during MVP were 85.0 and 99.9, respectively. Mean Cum%AP was not different between MVP versus DDD/R (48.7 +/- 38.5 vs 47.3 +/- 38.4, P = 0.83). During MVP overall time spent in AAI/R was 89.6% (intrinsic conduction), DDD/R 6.7% (intermittent AVB), and DDI/R 3.7% (AF). No adverse events were attributed to MVP. CONCLUSIONS: MVP safely achieves functional atrial pacing by limiting ventricular pacing to periods of intermittent AVB and AF in ICD patients, significantly reducing Cum%VP compared to DDD/R. MVP is a universal pacing mode that adapts to AVB and AF, providing both atrial pacing and ventricular pacing support when needed.

Adult↗

Clinical assessment and management of patients with implanted cardioverter-defibrillators presenting to nonelectrophysiologists.

All physicians increasingly will encounter patients who have implanted cardioverter-defibrillators (ICDs) for protection from ventricular arrhythmias. This advisory provides a concise summary relevant to the assessment and management of patients with ICDs, including those who present to primary care or emergency department physicians with symptoms suggesting arrhythmia or ICD malfunction and those who require cardiac or surgical procedures.

Anti-Arrhythmia Agents↗

Prospective randomized multicenter trial of empirical antitachycardia pacing versus shocks for spontaneous rapid ventricular tachycardia in patients with implantable cardioverter-defibrillators: Pacing Fast Ventricular Tachycardia Reduces Shock Therapies (PainFREE Rx II) trial results.

BACKGROUND: Successful antitachycardia pacing (ATP) terminates ventricular tachycardia (VT) up to 250 bpm without the need for painful shocks in implantable cardioverter-defibrillator (ICD) patients. Fast VT (FVT) >200 bpm is often treated by shock because of safety concerns, however. This prospective, randomized, multicenter trial compares the safety and utility of empirical ATP with shocks for FVT in a broad ICD population. METHODS AND RESULTS: We randomized 634 ICD patients to 2 arms-standardized empirical ATP (n=313) or shock (n=321)-for initial therapy of spontaneous FVT. ICDs were programmed to detect FVT when 18 of 24 intervals were 188 to 250 bpm and 0 of the last 8 intervals were >250 bpm. Initial FVT therapy was ATP (8 pulses, 88% of FVT cycle length) or shock at 10 J above the defibrillation threshold. Syncope and arrhythmic symptoms were collected through patient diaries and interviews. In 11+/-3 months of follow-up, 431 episodes of FVT occurred in 98 patients, representing 32% of ventricular tachyarrhythmias and 76% of those that would be detected as ventricular fibrillation and shocked with traditional ICD programming. ATP was effective in 229 of 284 episodes in the ATP arm (81%, 72% adjusted). Acceleration, episode duration, syncope, and sudden death were similar between arms. Quality of life, measured with the SF-36, improved in patients with FVT in both arms but more so in the ATP arm. CONCLUSIONS: Compared with shocks, empirical ATP for FVT is highly effective, is equally safe, and improves quality of life. ATP may be the preferred FVT therapy in most ICD patients.

Aged↗

Physiology of cardiac resynchronization.

Dyssynchronous ventricular contraction, often associated with delayed electrical activation, contributes to worsened clinical status in patients with chronic dilated heart failure. There are three levels of impaired electromechanical synchrony that can be recognized and potentially improved with pacing methods. Prolonged atrioventricular (AV) delay can promote presystolic mitral regurgitation and impaired left ventricular (LV) filling. Interventricular conduction delay with right ventricular (RV) activation preceding LV activation often occurs in the setting of left bundle branch block or RV apical pacing, and can result in impeded LV filling and ejection. Activation delays within the LV itself (intraventricular dyssynchrony) can cause decreased efficiency of contraction, increased mitral regurgitation, and abnormal ventricular remodeling. Cardiac resynchronization therapy (CRT) can improve ventricular performance in two thirds of patients selected based on QRS duration alone. Improved understanding of the pathophysiology of cardiac dyssynchrony will aid in patient selection and in assessment and optimization of response to CRT.

Atrioventricular Block↗

Randomized pilot study of a new atrial-based minimal ventricular pacing mode in dual-chamber implantable cardioverter-defibrillators.

OBJECTIVE: We hypothesized that a new minimal ventricular pacing mode (MVP) that provides AAI/R pacing with ventricular monitoring and back-up DDD/R pacing as needed during AV block (AVB) would significantly reduce cumulative percent ventricular pacing compared to DDD/R. BACKGROUND: Conventional DDD/R mode often results in high cumulative percent ventricular pacing that may adversely affect ventricular function and increase risk of heart failure and atrial fibrillation. METHODS: MVP was made operational in 30 patients with DDD/R implantable cardioverter-defibrillators (ICDs) and no history of AVB. Patients were randomized to one week each in DDD/R and MVP. Holter monitor recordings (ECG, intracardiac electrograms, and event markers) and device diagnostics were analyzed for cumulative % atrial paced (Cum%AP), cumulative percent ventricular pacing, and frequency and duration of DDD/R pacing back-up. Diaries were used to report symptoms. RESULTS: Age of the study population was 61 years +/- 12 years and 83% were male. Baseline PR interval was 204 ms +/- 32 ms and programmed AV intervals (DDD/R) were 200 ms +/- 50 ms (paced)/167 ms +/- 54 ms (sensed). Cum%AP was similar between MVP and DDD/R (47.9 +/- 37 vs 46.3 +/- 36). Cumulative percent ventricular pacing was significantly lower in MVP vs DDD/R (3.79 +/- 16.3 vs 80.6 +/- 33.8, P < .0001). Back-up DDD/R pacing during MVP operation due to transient AVB occurred in 10% of patients (9.3 +/- 7.4 [range 1-15] episodes/patient-day, duration 39.7 minutes +/- 156 minutes). Fifteen percent of AV intervals during MVP operation exceeded 300 ms. No significant symptoms were reported during MVP operation. CONCLUSIONS: MVP dramatically reduced cumulative percent ventricular pacing compared to DDD/R while maintaining AV synchrony and providing sensor-modulated atrial pacing support. Intermittent oscillations between MVP and DDD/R during transient AV block appeared safe and well tolerated.

Atrioventricular Node↗

Patient-specific computational analysis of transvenous defibrillation: a comparison to clinical metrics in humans.

The goal of this study is to assess the predictive capacity of computational models of transvenous defibrillation by comparing the results of patient-specific simulations to clinical defibrillation thresholds (DFT). Nine patient-specific models of the thorax and in situ electrodes were created from segmented CT images taken after implantation of the cardioverter-defibrillator. The defibrillation field distribution was computed using the finite volume method. The DFTs were extracted from the calculated field distribution using the 95% critical mass criterion. The comparison between simulated and clinical DFT energy resulted in a rms difference of 12.4 J and a 0.05 correlation coefficient (cc). The model-predicted DFTs were well matched to the clinical values in four patients (rms = 1.5 J; cc = 0.84). For the remaining five patients the rms difference was 18.4 J with a cc = 0.85. These results suggest that computational models based soley on the critical mass criterion and a single value of the inexcitability threshold are not able to consistently predict DFTs for individual patients. However, inspection of the weak potential gradient field in all nine patients revealed a relationship between the degree of dispersion of the weak field and the clinical DFT, which may help identify high DFT patients.

Adult↗

Prospective randomized study of mode switching in a clinical trial of pacemaker therapy for sinus node dysfunction.

INTRODUCTION: Atrial fibrillation (AF) is common in pacemaker patients with sinus node dysfunction (SND) and may result in rapid ventricular pacing (RVP) in the DDDR mode. Mode switching (MS) reduces RVP, but its clinical benefit in patients with SND is unknown. METHODS AND RESULTS: Two hundred two patients in the Mode Selection Trial (MOST; 2,010-patient, 6-year trial of DDDR vs VVIR pacing in SND) randomized to DDDR pacemakers with atrial high-rate episode (AHRE) storage capabilities were subrandomized to MS ON (N = 96) or MS OFF (N = 106). Cardiovascular symptoms, quality of life (QOL), reprogramming due to RVP, death, stroke, and heart failure hospitalization (HFH) were compared between groups. The treatment groups were similar with regard to AF history (59% MS ON vs 57% MS OFF). AHREs occurred in 49% patients during median follow-up of 2.2 years. Median AHRE duration (in min; MS ON 116 vs MS OFF 58, P = 0.29), frequency AHREs/week (MS ON 3.5 vs MS OFF 6.4, P = 0.23), and time spent in AHRE (min/week) (MS ON 450, MS OFF 268) were similar. Reprogramming due to any RVP during AHREs occurred more in MS OFF vs MS ON (13.2% vs 3.1%, P = 0.011) and marginally more for symptomatic RVP (8.5% vs 2.1%, P = 0.062). Cardiovascular symptoms occurred in 93.6% MS ON vs 90.2% MS OFF (P = 0.38). Median number of symptoms reported per visit was similar (MS ON 1.3 vs MS OFF 1.5, P = 0.62). Median symptom frequency/severity, summed and averaged over visits, was similar (MS ON 4.3 vs MS OFF 4.5, P = 0.74). QOL was not different between groups. Death, stroke, and HFH were not different between groups. CONCLUSION: MS reduces pacemaker reprogramming due to RVP during AHREs in a small number of patients but does not improve QOL or cardiovascular symptoms overall among patients with SND.

Aged↗

Delayed presentation of totally avulsed right superior vena cava after extraction of permanent pacemaker lead.

Pacemaker lead extraction has been shown to be an effective and safe treatment for infected permanent pacemaker leads, however, they may lead to potentially serious complications, usually occurring during the extraction procedure. This report describes a case of a 48-year-old woman with a patent persistent left SVC and an infected permanent pacemaker lead of a DDD pacing system who underwent transvenous laser-assisted lead extraction using a combined SVC and femoral approach. Two days after the procedure the patient developed symptoms of SVC obstruction requiring surgical intervention. The right SVC was found to be almost completely destroyed with only a thin strip of the lateral wall intact and active bleeding. The probable causative mechanisms and surgical management are discussed.

Device Removal↗