Correction for scatter and septal penetration using convolution subtraction methods and model-based compensation in 123I brain SPECT imaging-a Monte Carlo study.

Scatter and septal penetration deteriorate contrast and quantitative accuracy in single photon emission computed tomography (SPECT). In this study four different correction techniques for scatter and septal penetration are evaluated for 123I brain SPECT. One of the methods is a form of model-based compensation which uses the effective source scatter estimation (ESSE) for modelling scatter, and collimator-detector response (CDR) including both geometric and penetration components. The other methods, which operate on the 2D projection images, are convolution scatter subtraction (CSS) and two versions of transmission dependent convolution subtraction (TDCS), one of them proposed by us. This method uses CSS for correction for septal penetration, with a separate kernel, and TDCS for scatter correction. The corrections are evaluated for a dopamine transporter (DAT) study and a study of the regional cerebral blood flow (rCBF), performed with 123I. The images are produced using a recently developed Monte Carlo collimator routine added to the program SIMIND which can include interactions in the collimator. The results show that the method included in the iterative reconstruction is preferable to the other methods and that the new TDCS version gives better results compared with the other 2D methods.

Algorithms↗

A model that accounts for the interdependence of extent and severity in the automatic evaluation of myocardial defects.

BACKGROUND: The extent and severity are two important parameters when describing a regional defect in myocardial single-photon emission computed tomography (SPECT) perfusion imaging. Intuitively, these two parameters should be independent of each other, but we have shown in a previous study that there is an interdependence. This interdependence has been investigated in two commercially available analysis programs (AutoQUANT and 4D-MSPECT) using Monte Carlo-simulated SPECT data. METHODS: An anthropomorphic digital computer phantom and a Monte Carlo program were used to generate SPECT data. Several defects of different volumes and lesion activity uptake reductions were simulated and evaluated. Comparison of the measures of extent and severity with their corresponding known values led to the development of a correction model based on least-squares parameter estimation. This model was then applied to a test group consisting of 10 different computer-simulated patients. RESULTS: Our results showed that the interdependence was reduced significantly for most of our test cases after applying the correction method. The application of the correction model to the test group demonstrated that the model was robust with respect to different patient geometries. A further test with projections that simulated a perfect SPECT system revealed that the interdependence between the extent and severity was not caused by the limited spatial resolution of the SPECT system, but rather the inherent design of the algorithms of the analysis programs. CONCLUSIONS: A model has been developed to take into account the interdependence of the extent and severity.

Algorithms↗

Subendocardial versus transmural ischaemia in myocardial perfusion SPECT--a Monte Carlo study.

UNLABELLED: Myocardial perfusion imaging with single-photon emission computed tomography (SPECT) is useful for the evaluation of patients with known or suspected coronary artery disease. Parameters of interest are the reduction in the blood perfusion (severity) and the lesion volume (extent). The aim of this study was to evaluate these parameters, as calculated by automatic quantification software, for different cases of subendocardial and transmural myocardial lesions. METHODS: A computer phantom was used to simulate 32 male patients with different defect locations and activity uptakes, which were based on clinical patient studies. The Monte Carlo program SIMIND was used to simulate realistic SPECT projections which were reconstructed to give short-axis images, analysed by the AutoQUANT program using the same procedure as for a real patient. RESULTS: The results showed a disparity between the quantification of transmural and subendocardial lesions with the same lesion activity uptake reduction and this could be confirmed by visual interpretation. Neither the parameters given by the quantification program nor visual interpretation could distinguish between the transmural lesions and the subendocardial lesions with activity uptake reduction twice as high as in the corresponding transmural lesions. CONCLUSION: Transmural lesions and the corresponding subendocardial lesions with the same activity uptake reduction could be separated by the quantification software for SPECT imaging and visual analysis. The subendocardial lesions with activity uptake reduction twice as high as in the corresponding transmural lesions could not be differentiated neither by the quantification software nor by visual interpretation. Thus these lesions will get the same scoring when analysed by the AutoQUANT program.

Artificial Intelligence↗

A novel platform for radioimmunotherapy: extracorporeal depletion of biotinylated and 90Y-labeled rituximab in patients with refractory B-cell lymphoma.

Radioimmunotherapy is limited by the absorbed dose to radiosensitive organs. Removal of circulating radiolabeled MAbs after tumor tissue has been optimally targeted and should permit the administration of higher radioactivity to patients, resulting in a higher absorbed tumor dose. A novel "extracorporeal affinity adsorption treatment" (ECAT) device (MitraDep)was tested, with which biotinylated and radiolabeled MAbs can be removed from the circulation by passing whole blood over a filter coated with avidin. The antibodies were simultaneously radiolabeled and biotinylated using a trifunctional moiety comprising DOTA and biotin. Eight patients--all but 1 of whom with aggressive or mantle cell B-cell lymphoma-- who had failed to respond to standard therapies received infusions of 250 mg/m(2) cold rituximab and 150 MBq (111)In-rituximab-biotin for immunoscintigraphy. A week later, the patients were treated with another 250 mg/m(2) rituximab followed by (111)In/-(90)Y-rituximab-biotin (11 or 15 (90)Y MBq/kg). ECAT was performed 48 hours later. All 8 patients receiving (111)In-rituximab-biotin showed tumor uptake. Seven patients received radioimmunotherapy and subsequent ECAT. The mean depletion of (90)Y-rituximab-biotin in whole blood after ECAT was 96%, in the whole body 49%, in the lungs 62%, and in the liver and kidneys 40%. No effects on patients' vital signs and no adverse effects on hematological or coagulation parameters was observed during the ECAT procedure. A dose-escalation study is initiated.

Adsorption↗

A new method to obtain transmission images for planar whole-body activity quantification.

UNLABELLED: Dosimetry is important in the evaluation of new radiopharmaceuticals and in radionuclide therapy treatment planning. The base is an accurate in vivo measurement of the spatial and temporal distribution of the administered radioactivity. This can be made by planar whole-body activity quantification using the conjugate-view method where a geometrical-mean image is corrected for attenuation by a measured transmission image. We present a new method to measure whole-body transmission images using the X-ray unit on a single photon emission computed tomography/computed tomography (SPECT/CT) scintillation system. METHOD: Two general problems are associated with this method: (1) the divergence of the X-ray beam and (2) the scaling of the resulting image. We have applied linear transformations and scale by a system-generated factor to obtain images corresponding to a radiological depth at 70 keV. We validated the method by measurements of the radiological depth for different types of phantoms, and in terms of activity quantification accuracy when applying the method for attenuation correction. RESULTS: An accuracy of within +/-4% was found for both the radiological depth measurements and for the activity-quantification measurements. CONCLUSIONS: The advantage with the proposed method is that it is fast (2 minutes for a 2-minute scan), it has good spatial resolution and signal-to-noise ratio, and it is easy to carry out for the patient.

Humans↗

Dosimetry calculations on a tissue level by using the MCNP4c2 Monte Carlo code.

OBJECTIVE: The aim of this study was to develop a MCNP4c2-code and to further refine the small-scale anatomy intestinal dosimetry model based on a EGS4-code developed by Jonsson et al.(1,2) METHOD: The small intestine was modeled as a hexagonal tube system and includes cross-dose contribution from activity in nearby intestine loops. The model includes villi (height, 500 microm), radiosensitive crypt cells (height, 150 microm), and an overlying mucus layer of thicknesses (5-200 microm). The developed intestinal model used in either of the two Monte Carlo codes make it possible to calculate S-values and subsequent mean absorbed dose to the radiation-sensitive crypt cells in the small intestinal wall by considering contributions from the self-dose and from the cross-dose from nearby intestinal loops. Results are given for monoenergetic electrons and photons and for full decay schemes of (99m)Tc, (111)In, (131)I, (67)Ga, (90)Y, and (211)At. RESULTS: Results show that the cross-dose from nearby intestinal loops is significant, and that the fraction of cumulated activity in the intestinal wall contents is important for accurate absorbed-dose estimation. CONCLUSION: It is evident from our study that previous Medical Internal Radiation Dose (MIRD) and International Conference on Radiological Protection (ICRP) models tend to overestimate the absorbed dose to the wall. Our work on the gastrointestinal tract model includes several noticeable refinements, as compared to the MIRD- and ICRP model, and the "onion shell" geometry can easily be transferred to similar geometrical dosimetry applications.

Astatine↗

The LundADose method for planar image activity quantification and absorbed-dose assessment in radionuclide therapy.

A new method for absorbed-dose assessment in radionuclide therapy is presented in this paper. The method is based on activity quantification by the conjugate-view methodology, applied to serial whole-body, anterior-posterior, scintillation-camera scans. The quantification method is an extension of previous studies, and includes separate corrections for attenuation, scatter, and overlapping organs. Further development has now been undertaken to take into account the capabilities of new dual-head camera systems with a built-in X-ray tube for anatomical imaging. Furthermore, the modeling of time-activity data is included, and dosimetric calculations based on the formalism by the Medical Internal Radiation Dose (MIRD) committee. To streamline absorbed-dose assessments for a large number of patient studies, the programs for quantification, image registration, and absorbed-dose calculations have been embedded in an envelop program termed LundADose, where calculations, to a great extent, are performed automatically. Evaluation of the whole-body activity quantification is performed for patients undergoing radioimmunotherapy by monoclonal antibodies labeled with (111)In or (90)Y.

Cobalt Radioisotopes↗

Interdependence between measures of extent and severity of myocardial perfusion defects provided by automatic quantification programs.

AIM: To evaluate the accuracy of the values of lesion extent and severity provided by the two automatic quantification programs AutoQUANT and 4D-MSPECT using myocardial perfusion images generated by Monte Carlo simulation of a digital phantom. The combination between a realistic computer phantom and an accurate scintillation camera simulation tool allows the generation of realistic single-photon emission computed tomography (SPECT) images similar to those obtained in clinical patient studies. METHODS: The NCAT phantom and the SIMIND Monte Carlo program were used to simulate myocardial perfusion studies. Perfusion defects with sizes ranging from 5 to 17% of the left ventricular wall volume and reductions in tracer uptake of 20, 60 and 100% were simulated in three vascular territories. RESULTS: The values of the extent provided by the programs were dependent on the reduction in tracer uptake, i.e. the severity. Similarly, the measures of severity were dependent on the size of the lesions. The severity provided by AutoQUANT for different defects was not dependent on the location, whereas 4D-MSPECT presented different values depending on the location in the left ventricle. The measures of extent and severity of the defects with the same true extent and activity uptake reduction provided by the two programs were different. CONCLUSIONS: The NCAT phantom and the SIMIND Monte Carlo program were shown to be useful in simulating clinical myocardial SPECT studies. The quantification programs gave values of lesion extent that were dependent on the magnitude of the severity. Users should therefore consider this dependence when interpreting results from these programs.

Automation↗

Comparison of 1- and 2-day protocols for myocardial SPECT: a Monte Carlo study.

BACKGROUND: Myocardial perfusion single-photon emission computed tomography (SPECT) is carried out by combining a rest and a stress study that are performed either on one day or two separate days. A problem when performing the two studies on 1 day is that the residual activity from the first study contributes to the activity measured in the second study. AIM: Our aim was to identify and evaluate trends in the quantification parameters of myocardial perfusion images as a function of separation time between rest and stress. METHODS: A digital phantom was used for the generation of heart images and a Monte Carlo-based scintillation camera program was used to simulate SPECT projection images. In our simulations, the rest images were normal and the stress images included lesions of different types and localization. Two programs for quantification of myocardial perfusion images were used to assess the different images in an automated and objective way. RESULTS: The summed difference scores observed with the 2-day protocol were 3 +/- 1 (mean +/- SD) higher for AutoQUANT and 2 +/- 1 higher for 4D-MSPECT compared with those observed with the 1-day protocol. The extent values were 2% points higher for the 2-day protocol compared with the 1-day protocol for both programs. CONCLUSIONS: There are differences in the quantitative assessment of perfusion defects depending on the type of protocol used. The contribution of residual activity is larger when a 1-day protocol is used compared with the 2-day protocol. The differences, although small, are of a magnitude that results in a clear shift in quantification parameters.

Coronary Artery Disease↗

A new automated method for analysis of gated-SPECT images based on a three-dimensional heart shaped model.

A new automated method for quantification of left ventricular function from gated-single photon emission computed tomography (SPECT) images has been developed. The method for quantification of cardiac function (CAFU) is based on a heart shaped model and the active shape algorithm. The model contains statistical information of the variability of left ventricular shape. CAFU was adjusted based on the results from the analysis of five simulated gated-SPECT studies with well defined volumes of the left ventricle. The digital phantom NURBS-based Cardiac-Torso (NCAT) and the Monte-Carlo method SIMIND were used to simulate the studies. Finally CAFU was validated on ten rest studies from patients referred for routine stress/rest myocardial perfusion scintigraphy and compared with Cedar-Sinai quantitative gated-SPECT (QGS), a commercially available program for quantification of gated-SPECT images. The maximal differences between the CAFU estimations and the true left ventricular volumes of the digital phantoms were 11 ml for the end-diastolic volume (EDV), 3 ml for the end-systolic volume (ESV) and 3% for the ejection fraction (EF). The largest differences were seen in the smallest heart. In the patient group the EDV calculated using QGS and CAFU showed good agreement for large hearts and higher CAFU values compared with QGS for the smaller hearts. In the larger hearts, ESV was much larger for QGS than for CAFU both in the phantom and patient studies. In the smallest hearts there was good agreement between QGS and CAFU. The findings of this study indicate that our new automated method for quantification of gated-SPECT images can accurately measure left ventricular volumes and EF.

Artificial Intelligence↗

Accurate dosimetry in 131I radionuclide therapy using patient-specific, 3-dimensional methods for SPECT reconstruction and absorbed dose calculation.

UNLABELLED: (131)I radionuclide therapy studies have not shown a strong relationship between tumor absorbed dose and response, possibly due to inaccuracies in activity quantification and dose estimation. The goal of this work was to establish the accuracy of (131)I activity quantification and absorbed dose estimation when patient-specific, 3-dimensional (3D) methods are used for SPECT reconstruction and for absorbed dose calculation. METHODS: Clinically realistic voxel-phantom simulations were used in the evaluation of activity quantification and dosimetry. SPECT reconstruction was performed using an ordered-subsets expectation maximization (OSEM) algorithm with compensation for scatter, attenuation, and 3D detector response. Based on the SPECT image and a patient-specific density map derived from CT, 3D dosimetry was performed using a newly implemented Monte Carlo code. Dosimetry was evaluated by comparing mean absorbed dose estimates calculated directly from the defined phantom activity map with those calculated from the SPECT image of the phantom. Finally, the 3D methods were applied to a radioimmunotherapy patient, and the mean tumor absorbed dose from the new calculation was compared with that from conventional dosimetry obtained from conjugate-view imaging. RESULTS: Overall, the accuracy of the SPECT-based absorbed dose estimates in the phantom was >12% for targets down to 16 mL and up to 35% for the smallest 7-mL tumor. To improve accuracy in the smallest tumor, more OSEM iterations may be needed. The relative SD from multiple realizations was <3% for all targets except for the smallest tumor. For the patient, the mean tumor absorbed dose estimate from the new Monte Carlo calculation was 7% higher than that from conventional dosimetry. CONCLUSION: For target sizes down to 16 mL, highly accurate and precise dosimetry can be obtained with 3D methods for SPECT reconstruction and absorbed dose estimation. In the future, these methods can be applied to patients to potentially establish correlations between tumor regression and the absorbed dose statistics from 3D dosimetry.

Abdominal Neoplasms↗

Evaluation of accuracy in activity calculations for the conjugate view method from Monte Carlo simulated scintillation camera images using experimental data in an anthropomorphic phantom.

UNLABELLED: Activity determination from scintillation camera images using the conjugate view method may be inaccurate because of variation in scattered radiation from adjacent organs and activity from overlapping tissues. The aim of this study was to simulate patient scintillation camera images and from these evaluate the accuracy of 2 correction methods. The contribution from overlapping tissue activity was also calculated for some organs. METHODS: Biokinetic data for (99m)Tc-sestamibi obtained in rats was used as input to simulate scintillation camera images with a voxel-based computer phantom using the Monte Carlo method. The organ activity was calculated using the conjugate view method with either the effective attenuation coefficient method or scatter correction using the triple-energy window (TEW) method combined with attenuation correction with a transmission factor image. Images were simulated with activity in organs one by one to evaluate the accuracy of the 2 correction methods and to evaluate the activity contribution from activity in adjacent or overlapping tissues. To allow comparison with the clinical situation, the total activity distribution from the animal study was used to simulate scintillation camera images at different points in time and the calculated activity was compared with both the input data and some patient data from the literature. RESULTS: The combination of scatter and attenuation correction gave the most accurate calculated activity, +/-10% of the true activity from the images with activity in one organ at a time. In the images similar to the clinical situation, the kidney activity was overestimated up to a factor of 34, mainly because of excretion of activity through the intestines. CONCLUSION: The scatter correction using the TEW method in combination with attenuation correction with the measured transmission factor resulted in the most accurate activity determination of the methods used. This study also shows that organ activity data calculated from scintillation camera images may be overestimated by >90% because of activity in overlapping tissues.

Animals↗

Absorbed dose distribution in glioma tumors in rat brain after therapeutic intratumoral injection of 201Tl-chloride.

Studies on animals with gliomas inoculated in the brain and treated with intratumoral injections of 201Tl-chloride have previously shown very promising results, with a survival several weeks longer than controls. Total regression was found in some animals, and necrosis was found in all the 201Tl-treated brain tumors. This study was undertaken to estimate the absorbed dose and dose distribution to the tumor based on the localization and clearance properties obtained from images with two high-resolution imaging techniques; pinhole single photon emission computed tomography (SPECT) and beta-camera. The images from the beta-camera were used to calculate the absorbed dose rate, using an in-house-developed, voxel-based Monte Carlo program, based on the EGS4 package. To evaluate the effects of different beta-particle energies on the absorbed dose rate distribution, simulations of medium- and high-energy electrons were conducted. Dose-volume histograms from these simulations show that the energy absorption is very locally distributed for 201Tl and medium energy, whereas high-energy beta emitters show a broader dose-volume distribution. The calculated total absorbed dose of 2-8 Gy in the tumor seems to be relativity low when considering the therapeutic effect that was seen. Further investigations, to determine the cause of the high therapeutic efficacy, are needed.

Animals↗

Evaluation of parameters influencing S values in mouse dosimetry.

UNLABELLED: Clinical radionuclide therapy studies are commonly preceded by studies with small animals. Reliable evaluation of therapeutic efficacy must be based on accurate dosimetry. This study was performed to evaluate the influence of the mass of organs, the shape of organs, and the distances between organs on S values for mice. METHODS: A voxel-based version of a geometric model of a mouse was developed for input in our Monte Carlo program based on EGS4. Simulations were made for each source organ separately to resolve the S values for each organ. For verification purposes, S values were calculated for spheres of different masses and compared with the S values in the MIRDOSE3.1 software and with the S values on the Radiation Dose Assessment Resource Web site. The variation in the mass of the organs was determined from dissected mice. The influence of the shape of an organ was investigated by successive elongation of a sphere into spheroids with a constant mass. The right kidney was moved in the phantom of the mouse to evaluate the effect of organ distances on S values. The absorbed fractions for the mouse model presented here were compared with the results from some previously published models. The radionuclides used were (90)Y, (131)I, (111)In, and (99m)Tc. RESULTS: The results showed that the organ mass for one animal can differ by up to 33% from the mean mass. If linear interpolation from S value tables is used to obtain an S value for the specific mass of an organ, then the S value can differ by up to 80% from its true value. The corresponding deviation obtained by scaling according to mass is 20%. The shape of an organ was found to be the least important parameter for the S value. The cross-absorbed S value is strongly dependent on the geometry and the emitted radiation. For example, a 9.2-mm movement of the kidney can cause the S value from the liver to the right kidney to decrease to 0.05% of its original value for (90)Y. CONCLUSION: We conclude that the mass and the shape of organs and their locations relative to each other have considerable effects on mouse dosimetry.

Algorithms↗

3D absorbed dose calculations based on SPECT: evaluation for 111-In/90-Y therapy using Monte Carlo simulations.

A general method is presented for patient-specific three-dimensional (3D) absorbed dose calculations based on quantitative SPECT activity measurements. The computational scheme includes a method for registration of the CT study to the SPECT image, and compensation for attenuation, scatter, and collimator-detector response including septal penetration, performed as part of an iterative reconstruction method. From SPECT images, the absorbed dose rate is calculated using an EGS4 Monte Carlo code, which converts the activity distribution to an absorbed dose rate distribution. Evaluation of the accuracy in the activity quantification and the absorbed dose calculation is based on realistic Monte Carlo simulated SPECT data of a voxel-computer phantom and (111)In and (90)Y. Septal penetration was not included in this study. The SPECT-based activity concentrations and absorbed dose distributions are compared to the actual values; the results imply that the corrections for attenuation and scatter yield results of high accuracy. The presented method includes compensation for most parameters deteriorating the quantitative image information. Inaccuracies are, however, introduced by the limited spatial resolution of the SPECT system, which are not fully compensated by the collimator-response correction. The proposed evaluation methodology may be used as a basis for future inter-comparison of different dosimetry calculation schemes.

Humans↗

Crypt cell dosimetry for 99Tcm-sestamibi in a new small intestinal dosimetry model.

The aim of the study was to calculate the absorbed dose to the crypt cells in the small intestine from (99)Tc(m)-sestamibi excreted through the intestinal tract. The absorbed dose was calculated taking into consideration the biodistribution of the radiopharmaceutical in the small intestinal wall and its contents, based on data gathered in rats. Absorbed dose calculations were performed using a new intestinal model in which S values for crypt cells are given both for the intestinal wall and for the intestinal contents as source organs. A maximum of 6% of the injected activity was found to be located in the intestinal wall at 30 minutes after injection and 13% in the intestinal contents at 2 h, resulting in an absorbed dose of 8.9 microGy/MBq to the crypt cells. Assuming the activity to be located only in the wall, we calculate an absorbed dose to the crypt cells 2.5 times higher than if all the activity is assumed to be present in the intestinal contents. Using the new intestinal dosimetry model, together with detailed biokinetic data for the radiopharmaceutical from animal studies, it is possible to calculate the absorbed dose to the crypt cells, which is not possible when using external imaging.

Animals↗

A parallel Monte Carlo code for planar and SPECT imaging: implementation, verification and applications in (131)I SPECT.

This paper reports the implementation of the SIMIND Monte Carlo code on an IBM SP2 distributed memory parallel computer. Basic aspects of running Monte Carlo particle transport calculations on parallel architectures are described. Our parallelization is based on equally partitioning photons among the processors and uses the Message Passing Interface (MPI) library for interprocessor communication and the Scalable Parallel Random Number Generator (SPRNG) to generate uncorrelated random number streams. These parallelization techniques are also applicable to other distributed memory architectures. A linear increase in computing speed with the number of processors is demonstrated for up to 32 processors. This speed-up is especially significant in Single Photon Emission Computed Tomography (SPECT) simulations involving higher energy photon emitters, where explicit modeling of the phantom and collimator is required. For (131)I, the accuracy of the parallel code is demonstrated by comparing simulated and experimental SPECT images from a heart/thorax phantom. Clinically realistic SPECT simulations using the voxel-man phantom are carried out to assess scatter and attenuation correction.

Computer Simulation↗

An activity quantification method based on registration of CT and whole-body scintillation camera images, with application to 131I.

UNLABELLED: This article presents a new method for conjugate view activity quantification for 131I-labeled monoclonal antibody distribution. METHODS: The method is based on the combined use of images from 3 modalities: whole-body (WB) scintillation camera scanning, WB transmission scanning using 57Co, and CT. All images are coaligned using a recently developed program for the registration of WB images. Corrections for attenuation, scatter, and septal penetration are performed in image space. Compensation for scatter and septal penetration is performed by deconvolution, using point-response functions determined from Monte Carlo simulations. Attenuation correction is performed by applying a patient-specific 364-keV narrow-beam attenuation map obtained by combining information from the CT and the transmission scan. A relationship is presented for the conversion of the CT numbers to mass density. The attenuation- and scatter-compensated image is converted from counts to activity using a sensitivity value that was determined for 364-keV photons in air. This activity projection image is then analyzed for the activity of volumes of interest (VOI) using 2-dimensional regions of interest (ROIs) that are determined from the CT study. The CT is first resliced into coronal slices, and a maximum-extension ROI is outlined that encloses the VOI. Compensation for background activity and overlapping organs is performed on the basis of total patient thickness in the projection line, and on precalculated organ- background thickness fractions. RESULTS: Method evaluation was performed using data from both experimental measurements and Monte Carlo simulations. The use of an attenuation map derived directly from the CT study was also evaluated. For organ activity quantification, an accuracy of > or =10% was obtained. For small-diameter tumors, deviations were larger because of lack of correction for the background-dependent partial-volume effect. CONCLUSION: Registration of CT and WB scintillation camera images was successfully applied to improve activity quantification by the conjugate view method.

Antibodies, Monoclonal↗