Michael J Banner

Publications and source records attributed to Michael J Banner.

5 recordsLinked to original sources

Power of breathing determined noninvasively with use of an artificial neural network in patients with respiratory failure.

OBJECTIVE: To determine work of breathing per minute or power of breathing noninvasively (POB(N)) by using an artificial neural network (ANN) without the need for an esophageal catheter in patients with respiratory failure. DESIGN: Prospective study comparing the relationship between POB(N) and invasively measured power of breathing (POB(I)). SETTING: Intensive care unit of a university hospital. PATIENTS: Forty-five intubated adults (age, 51 +/- 11 yrs; weight, 71 +/- 18 kg; 28 males and 17 females) receiving pressure support ventilation (PSV). INTERVENTIONS: Data from an esophageal catheter and airway pressure/flow sensor were used to measure POB(I). A pretrained ANN provided real time calculation of POB(N). POB(I) and POB(N) were measured at various levels of PSV, ranging from 5 to 25 cm H(2)O. MEASUREMENTS AND MAIN RESULTS: POB(N) was highly correlated with POB(I) (r = 0.91; p < .002), and because POB(N) explained or predicted 83% of the variance in POB(I), it was considered a very good predictor (r(2) = 0.83; p < .002). Bias was negligible (0.00) and precision was clinically acceptable (2.2 J/min). CONCLUSIONS: POB can be calculated noninvasively with reasonable clinical accuracy for patients receiving ventilatory support by using an ANN. This method obviates the need for inserting an esophageal catheter and thus greatly simplifies measurement of POB. POB(N) may be a clinically useful tool for consideration when setting PSV to unload the respiratory muscles. Before considering its use in clinical practice, POB(N) would need to be incorporated within the context of load tolerance and shown to improve outcomes.

Female↗

Intratracheal pressure: a more accurate reflection of pulmonary airway pressure in pediatric patients with respiratory failure.

OBJECTIVES: Peak inflation pressure (PIP) on many ventilators (P(vent)), measured distal to the exhalation limb or Y-piece of the breathing circuit, is assumed as the pressure applied to the airways and lungs. However, in vitro studies show P(vent) data are spurious. There are no studies evaluating the accuracy of P(vent) data for pediatric patients with acute respiratory failure. We hypothesized that intratracheal airway pressure (P(T)) is more accurate than P(vent) and that by using P(vent), abnormally increased imposed resistive work of breathing (WOBi) may go undetected. DESIGN: Prospective and descriptive study. SETTING: A pediatric intensive care unit at a university hospital. PATIENTS: Twenty-one pediatric patients with respiratory failure requiring mechanical ventilation. INTERVENTIONS: All patients were intubated with a commercially available endotracheal tube (ETT) with a pressure measuring the lumen opening at the distal end used for measuring P(T). Pressure/flow sensors positioned between the ETT and Y-piece measured tidal volume (V(T)) and flow rate. P(vent) data were recorded as displayed on the ventilator. WOBi was measured by integrating P(T) and V(T) data. RESULTS: PIP at P(vent) and P(T) were 26 +/- 8 cm H(2)O and 19 +/- 7 cm H(2)O, respectively (p < .05). P(T) measurements averaged 27% less than P(vent). The relationship between P(vent)-P(T) (pressure drop across the breathing circuit and ETT) and flow rate during spontaneous inhalation was highly correlated (r = .80, p < .002), indicating the greater the flow rate, the greater the pressure drop and WOBi. WOBi, ranging from 0.04-1.5 J/L, was measured in 52% of the patients. CONCLUSIONS: P(vent) significantly overestimates PIP. Moreover, P(vent) data does not allow for recognition of increased WOBi for many patients. Clinicians need to be aware of the limitations of P(vent) data and consider using ETTs that allow measurement of P(T), a more accurate reflection of pulmonary airway pressure.

Adolescent↗

Isoflurane inhalation enhances increased physiologic deadspace volume associated with positive pressure ventilation and compromises arterial oxygenation.

Abnormally increased physiologic deadspace volume (Vd(phys)), consisting of alveolar deadspace volume and airway deadspace volume, is one of several causative factors predisposing to compromised arterial blood gas exchange. We compared the effects of two methods of general anesthesia on Vd(phys) when combined with positive pressure ventilation (PPV): total IV anesthesia (TIVA) and inhaled anesthesia with isoflurane. Forty patients with no history of pulmonary pathology undergoing elective surgery in the supine position were studied. A crossover design was used, and all patients received both anesthetic methods sequentially in randomized order. PPV and TIVA significantly increased Vd(phys) compared with baseline (preoperative and breathing spontaneously) from 164 +/- 60 mL to 264 +/- 79 mL (P < 0.05). Isoflurane inhalation combined with PPV significantly enhanced this increase, resulting in a twofold increase in Vd(phys) to 315 +/- 80 mL (P < 0.05). Also, alveolar deadspace volume increased by more than 200% with isoflurane. Furthermore, isoflurane inhalation (1.15% end-tidal concentration) resulted in impaired arterial oxygenation, as evidenced by a significant decrease in the Pao(2)/fractional inspired oxygen concentration ratio compared with baseline values from 387 +/- 35 to 310 +/- 70 (P < 0.05). Although significant increases in Vd(phys) resulted with PPV combined with TIVA, these adverse changes were much less compared with isoflurane inhalation and PPV. These findings may apply to subjects with compromised pulmonary function (i.e., acute respiratory distress syndrome or severe inhalational burn injury).

Adult↗

Tracheal pressure control provides automatic and variable inspiratory pressure assist to decrease the imposed resistive work of breathing.

OBJECTIVE: To evaluate the operation of a continuous positive airway pressure system by using tracheal airway pressure (PT) as the control signal for system operation (i.e., tracheal pressure control). DESIGN: Repeated measures. SETTING: University research laboratory. SUBJECTS: Twelve anesthetized, spontaneously breathing swine. INTERVENTIONS: Subjects were intubated and connected to a tracheal pressure control system (5 cm H2O continuous positive airway pressure). Varying inspiratory flow demands and degrees of partial endotracheal tube occlusion (25%, 50%, and 75%) were studied. Tracheal pressure control was compared with a conventionally controlled system (pressure from breathing circuit Y-piece [PY] used as control signal) during endotracheal tube occlusion. MEASUREMENTS AND RESULTS: Imposed resistive work of breathing (work to spontaneously inhale through endotracheal tube and ventilator circuit), work by ventilation system assisting inhalation, PT, PY, tidal volume, and inspiratory flow demands were measured. As inspiratory flow demands increased (range, 0.2-2.3 L/sec), pressure assist increased automatically (range, 5-40 cm H2O) as well as work of breathing by ventilation system assisting inhalation (range, 0.2-2.5 J/L). Imposed resistive work of breathing was nullified at the lower and was negligible at the higher flow demands. During endotracheal tube occlusion with a conventionally controlled system, PY was unchanged, whereas PT decreased (up to -15 cm H2O) and imposed resistive work of breathing increased (up to 1.05 J/L). With tracheal pressure control, PY increased automatically (range, 8-52 cm H2O), whereas PT varied slightly (range, 2 to -4.6 cm H2O). Imposed resistive work of breathing was negligible (range, 0-0.2 J/L). Breathing circuit pressure (PY), not pulmonary airway pressure (PT), increased significantly during tracheal pressure control. CONCLUSIONS: Tracheal pressure control results in automatic and variable levels of pressure assist to decrease imposed resistive work of breathing under conditions of varying spontaneous inspiratory flow demands and endotracheal tube occlusion. Conventional systems are potentially flawed when PY is used as the control signal because they do not function in this manner and do not accurately assess pulmonary airway pressure.

Animals↗