Search PubMed⌕ Search

Biomedical subjects

Michael I Miga

Publications and source records attributed to Michael I Miga.

5 recordsLinked to original sources

A new approach to elastography using mutual information and finite elements.

Historically, increased mechanical stiffness during tissue palpation exams has been associated with assessing organ health as well as with detecting the growth of a potentially life-threatening cell mass. As such, techniques to image elasticity parameters (i.e., elastography) have recently become of great interest to scientists. In this work, a new method of elastography will be introduced within the context of mammographic imaging. The elastography method proposed represents a non-rigid iterative image registration algorithm that varies material properties within a finite element model to improve registration. More specifically, regional measures of image similarity are used within an objective function minimization framework to reconstruct elasticity images of tissue stiffness. Numerical simulations illustrate: (1) the encoding of stiffness information within the context of a regional image similarity criterion, (2) the methodology for an iterative elastographic imaging framework and (3) elasticity reconstruction simulations. The real strength in this approach is that images from any modality (e.g., magnetic resonance, computed tomography, ultrasound. etc) that have sufficient anatomically-based intensity heterogeneity and remain consistent from a pre- to a post-deformed state could be used in this paradigm.

Adipose Tissue↗

Cortical surface registration for image-guided neurosurgery using laser-range scanning.

In this paper, a method of acquiring intraoperative data using a laser range scanner (LRS) is presented within the context of model-updated image-guided surgery. Registering textured point clouds generated by the LRS to tomographic data is explored using established point-based and surface techniques as well as a novel method that incorporates geometry and intensity information via mutual information (SurfaceMI). Phantom registration studies were performed to examine accuracy and robustness for each framework. In addition, an in vivo registration is performed to demonstrate feasibility of the data acquisition system in the operating room. Results indicate that SurfaceMI performed better in many cases than point-based (PBR) and iterative closest point (ICP) methods for registration of textured point clouds. Mean target registration error (TRE) for simulated deep tissue targets in a phantom were 1.0 +/- 0.2, 2.0 +/- 0.3, and 1.2 +/- 0.3 mm for PBR, ICP, and SurfaceMI, respectively. With regard to in vivo registration, the mean TRE of vessel contour points for each framework was 1.9 +/- 1.0, 0.9 +/- 0.6, and 1.3 +/- 0.5 for PBR, ICP, and SurfaceMI, respectively. The methods discussed in this paper in conjunction with the quantitative data provide impetus for using LRS technology within the model-updated image-guided surgery framework.

Adult↗

Incorporation of a laser range scanner into image-guided liver surgery: surface acquisition, registration, and tracking.

As image guided surgical procedures become increasingly diverse, there will be more scenarios where point-based fiducials cannot be accurately localized for registration and rigid body assumptions no longer hold. As a result, procedures will rely more frequently on anatomical surfaces for the basis of image alignment and will require intraoperative geometric data to measure and compensate for tissue deformation in the organ. In this paper we outline methods for which a laser range scanner may be used to accomplish these tasks intraoperatively. A laser range scanner based on the optical principle of triangulation acquires a dense set of three-dimensional point data in a very rapid, noncontact fashion. Phantom studies were performed to test the ability to link range scan data with traditional modes of image-guided surgery data through localization, registration, and tracking in physical space. The experiments demonstrate that the scanner is capable of localizing point-based fiducials to within 0.2 mm and capable of achieving point and surface based registrations with target registration error of less than 2.0 mm. Tracking points in physical space with the range scanning system yields an error of 1.4 +/- 0.8 mm. Surface deformation studies were performed with the range scanner in order to determine if this device was capable of acquiring enough information for compensation algorithms. In the surface deformation studies, the range scanner was able to detect changes in surface shape due to deformation comparable to those detected by tomographic image studies. Use of the range scanner has been approved for clinical trials, and an initial intraoperative range scan experiment is presented. In all of these studies, the primary source of error in range scan data is deterministically related to the position and orientation of the surface within the scanner's field of view. However, this systematic error can be corrected, allowing the range scanner to provide a rapid, robust method of acquiring anatomical surfaces intraoperatively.

Aged↗

Source localization using a current-density minimization approach.

Determining the location of cortical activity from electroencephalographic (EEG) data is important clinically. In this paper, a method is presented which uses the powerful optimization method of simulated annealing in conjunction with a finite-element-based model of the search domain for single-time slice solution of the EEG-inverse problem. The algorithm highlights a new objective function based on the current-density boundary integral associated with the finite-element formulation as the basis for parameter optimization. In two-dimensional experiments in a shallow tank containing saline, single dipoles are located within 2 mm. Simulations studying the algorithms response to structured noise are also presented. The new objective function is shown to take advantage of the natural framework associated with finite-elements and the results suggest that the approach is capable of resolving dipole locations in simulations and experiments.

Brain Mapping↗

In vivo quantification of retraction deformation modeling for updated image-guidance during neurosurgery.

The use of coregistered preoperative anatomical scans to provide navigational information in the operating room has greatly benefited the field of neurosurgery. Nonetheless, it has been widely acknowledged that significant errors between the operating field and the preoperative images are generated as surgery progresses. Quantification of tissue shift can be accomplished with volumetric intraoperative imaging; however, more functional, lower cost alternative solutions to this challenge are desirable. We are developing the strategy of exploiting a computational model driven by sparse data obtained from intraoperative ultrasound and cortical surface tracking to warp preoperative images to reflect the current state of the operating field. This paper presents an initial quantification of the predictive capability of the current model to computationally capture tissue deformation during retraction in the porcine brain. Performance validation is achieved through comparisons of displacement and pressure predictions to experimental measurements obtained from computed tomographic images and pressure sensor recordings. Group results are based upon a generalized set of boundary conditions for four subjects that, on average, account for at least 75% of tissue motion generated during interhemispheric retraction. Individualized boundary conditions can improve the degree of data-model match by 10% or more but warrant further study. Overall, the level of quantitative agreement achieved in these experiments is encouraging for updating preoperative images to reflect tissue deformation resulting from retraction, especially since model improvements are likely as a result of the intraoperative constraints that can be applied through sparse data collection.

Animals↗