Evaluation of the potential absorbed doses from patients based on whole-body 131I clearance in thyroid cancer therapy.

The evaluation of the absorbed dose from radioactive patients during the treatment of thyroid disease is an important factor in establishing precautions in these procedures, and the I retention/excretion by patients' bodies provides additional information to medical and radioprotection service. In 94 patients, the measurement of exposure rates was performed over 7 d following NaI administration, and the rates permitted the study of the dynamics of excretion and the potential dose evaluation. The administered activities ranged from 3.7 GBq (100 mCi) to 16.65 GBq (450 mCi), and the results proved that the majority of the activity is excreted by patients in the first 3 d after NaI administration. The average (131)I activity excreted at 24, 48, 72, 96, and 120 h after oral administration was (72 +/- 10), (91 +/- 6), (97 +/- 3), (98.9 +/- 1.5), and (99.6 +/- 0.7)%, respectively. According to the administered activity, the evaluation of the accumulated absorbed dose from patients ranged from 3.0 +/- 0.7 to 8.4 +/- 1.1 mSv at 1 m and 1.2 +/- 0.4 to 3.2 +/- 0.4 mSv at 2 m. The data reported here are important to radioprotection policy and to add to and improve on the guidelines reported in U.S. NRC Regulatory Guide 8.39.

Adolescent↗

A new proposal for monitoring patients in nuclear medicine.

The measurement of exposure rates is fundamentally important in the release of patients given radioactive materials and for keeping the exposures of others as low as reasonable achievable. Similar measurement methodologies have generally been used for point and extended sources, but this approach may lead to methodological errors in calculating radiation dose estimates. In this study, nuclear medicine patients who received high activities of Na131I for therapy were monitored using different measurement methodologies, and the results showed that the usual measurement performed at 1.0 m in front of the body resulted in a mean error of 40% between experimental and theoretical exposure rates. The best measurements were obtained when performed at 2.0 m in front of the patients. With this approach, the error was about 2% between experimental and theoretical values. These findings suggest a new methodology for patients' measurement in nuclear medicine and could be useful for personal monitoring in cases of radiological emergencies involving 131I ingestion.

Adolescent↗

Voxel-based mouse and rat models for internal dose calculations.

UNLABELLED: The ability to estimate absorbed doses in experimental animals to which radiolabeled material has been administered may be important in explaining and controlling potential radiation toxicity observed during preclinical trials. Most previously reported models for establishing doses to small animals have been stylized and mathematically based. This study establishes dose factors for internal sources in realistic models of a typical mouse and a typical rat, based on image data obtained using a dedicated small-animal CT scanner. METHODS: A transgenic mouse (body mass, 27 g) and a Sprague-Dawley rat (body mass, 248 g) were imaged using the dedicated small-animal CT scanner. Identified organs were segmented using computer tools that Vanderbilt University applies to process human images for 3-dimensional dosimetry. Monte Carlo N-particle transport code (MCNP) input files were prepared from the 3-dimensional, voxel-based image data. Using methods established for human studies, radiation transport calculations of absorbed fractions (AFs) were performed using MCNP, version 4C, on the segmented images, and dose conversion factors for several radionuclides were developed. RESULTS: AFs were established at discrete energies for electron and photon sources assumed to be uniformly distributed throughout approximately 10 source and target regions in both models. Electron self-irradiation AFs were significantly less than 1.0 for many organs, at energies above 0.5 MeV, and significant cross irradiation was observed for high-energy electrons, such as those from (90)Y or (188)Re, in many organs. Calculated dose conversion factors reflected these trends and agreed well with the results of other authors who have undertaken similar investigations. CONCLUSION: The AFs calculated in this study will be useful in determining the dose to organs for mice and rats similar in size to those studied here. The segmented, voxel-based models developed here can be used for external dose calculations as well.

Animals↗

Safety, biodistribution, and dosimetry of 123I-IMPY: a novel amyloid plaque-imaging agent for the diagnosis of Alzheimer's disease.

UNLABELLED: (123)I-IMPY (6-iodo-2-(4'-dimethylamino-)phenyl-imidazo[1,2-a]pyridine) is a novel radiopharmaceutical that selectively binds to Alzheimer's disease (AD) amyloid plaques. As a first step toward validating this radiopharmaceutical as an imaging biomarker for AD, we measured the whole-body biokinetics and radiation dosimetry of (123)I-IMPY in AD patients and cognitively normal control subjects. The pharmacologic safety profile of the compound was simultaneously assessed. METHODS: The sample included 9 subjects ranging in age from 44 to 80 y. Whole-body images were obtained for each subject (mean +/- SD, 9.0 +/- 3.2 scans per subject) for up to 48 h after the intravenous administration of 185 MBq (5 mCi) of (123)I-IMPY. The fraction of administered activity in 12 regions of interest was quantified from the attenuation-corrected geometric mean counts in conjugate views. Multiexponential functions were iteratively fit to each time-activity curve using a nonlinear, least-squares regression algorithm. These curves were numerically integrated to yield cumulated activity values for source organs. Radiation doses were then estimated with the MIRD technique. RESULTS: The radiotracer had no pharmacologic effects (produced no changes in heart rate, blood pressure, or laboratory results) on any of the subjects. Radiation dosimetry estimates indicated that the dose-limiting organ was the gallbladder, which received an average of 0.135 mGy/MBq (range, 0.075-0.198 mGy/MBq). The effective dose equivalent and effective dose for (123)I-IMPY were 0.042 +/- 0.003 mSv/MBq and 0.035 +/- 0.001 mSv/MBq, respectively. The mean effective dose for (123)I-IMPY was similar to that for (111)In-diethylenetriaminepentaacetic acid (0.035 mGy/MBq), less than half that for (111)In-pentetreotide (0.81 mGy/MBq), and approximately twice that for (123)I-IMP (0.018 mGy/MBq). No significant differences were found between men and women or between AD patients and control subjects. CONCLUSION: (123)I-IMPY may be a safe radiotracer with appropriate biokinetics for imaging amyloid plaques in AD patients.

Adult↗

131I ablation treatment in young females after the Chernobyl accident.

UNLABELLED: The Chernobyl accident resulted in a number of cases of thyroid cancer in females under the age of 20 y. Many of these individuals were treated with surgical removal of the thyroid gland followed by 131I ablation of residual thyroid tissue. Epidemiologic evidence demonstrates that 131I treatment for thyroid cancer or hyperthyroidism in adult women confers negligible risk of breast cancer. However, comparable data for younger women do not exist. Studies of external radiation exposure indicate that, for radiation exposures of as low as 0.2-0.7 Gy, the risk of breast cancer is greater for infant and adolescent female breast tissues than for adult female breast tissues. METHODS: The effective half-time of 131I measured in athyrotic patients was used together with the OLINDA/EXM computer code to estimate doses to breast tissue in 10-y-old, 15-y-old, and young adult females from ablation treatment. RESULTS: The dose to pediatric and young adult female breast tissue associated with a 5.6-GBq (150 mCi) ablation treatment may range from 0.35 to 0.55 Gy, resulting in a lifetime risk of breast cancer ranging from 2-4 cases per 100 such individuals exposed and a lifetime risk of solid tumors ranging from 8 to 17 solid tumors per 100 such individuals exposed. Administration of multiple ablation treatments, as often occurs with metastases, could result in doses ranging from 0.7 to 1 Gy, with corresponding increases in the lifetime cancer risk. CONCLUSION: These estimates suggest the need for additional research and a possible need for surveillance of young Chernobyl thyroid cancer patients who received 131I ablation treatment.

Adolescent↗

Radiation-absorbed dose from 201Tl-thallous chloride.

UNLABELLED: Revised radiation dosimetry estimates for 201Tl-thallous chloride have been developed using new data specifically acquired to address the issue of testicular uptake of this agent and through reevaluation of extant data for biodistribution in other organs. METHODS: Quantitative testicular scintigraphy data of sequestered testes (body-background shielded) were obtained from 28 patients (56 studies) injected with 201Tl-thallous chloride at peak exercise. Previously published data for 15 patients injected at maximal exercise were reanalyzed to obtain updated biodistribution parameters for designated organs. Radiation dose was calculated according to the MIRD schema. Radiation dose to testes as a function of age was determined. Comparisons are made between organ dose estimates derived in this study and those previously published. The dose contributions of possible contaminants (200Tl, 202Tl, 203Pb) have been included. Estimates are provided of the dose component from these contaminants if injected at the time of the maximum recommended 5-d shelf life (as opposed to at the designated calibration time). RESULTS: The radiation dose per unit administered activity to adult testes calculated in this study of 0.21 mGy/MBq (0.77 rad/mCi) is approximately a factor of 2 less than the value of 0.45 mGy/MBq (1.7 rad/mCi) previously accepted. The revised dose estimates for other organs show less variation from published values. The effective dose determined in this work is approximately 0.16 mSv/MBq (0.60 rem/mCi). Under the assumption of similar biokinetics as for the adult, the testes dose for children increases significantly as age decreases with a value of 7.5 mGy/MBq (28 rad/mCi) for a newborn. Contributions from radiocontaminants that may be encountered in the preparation of 201Tl-thallous chloride are shown to range from a fraction of a percent up to approximately 20% of the total dose for some organs, with the higher values arising from the long half-life contaminant 202Tl after a 5-d shelf life. CONCLUSION: It is recommended that the dose values determined in this study be used when estimating the radiation dose to the adult testes from intravenous administration of 201Tl-thallous chloride. The potential for increased radiation dose per administered activity to the testes at younger ages should be evaluated before performing procedures on children. The presence of radiocontaminants in the product should be considered when estimating radiation dose and may add a significant contribution to dose dependent on the specific radionuclide and concentration at the time of administration.

Body Burden↗

Biodistribution and radiation dosimetry of 11C-WAY100,635 in humans.

UNLABELLED: Serotonin 1A receptors have been implicated in a variety of conditions including depression, suicidal behavior, and aggression. Dose estimates for current human studies are based on data from rat dosimetry studies. We report the biodistribution and dosimetry of the PET serotonin 1A antagonist 11C-WAY100,635 in humans. METHODS: PET studies of 6 healthy human volunteers (3 male, 3 female) were acquired after a bolus injection of 11C-WAY100,635. Transmission scans of 3.5 min were obtained at each bed position before injection, and emission scans then were collected in 2-dimensional mode over 8 bed positions. Regions of interest were drawn around the brain, left and right lungs, heart, liver, stomach wall, gallbladder, left and right kidneys, spleen, and urinary bladder. Because no fluid was removed from the subjects, whole-body radioactivity was calculated using the injected dose and a calibration factor determined from a cylinder phantom. The area under the curve for each region of interest was determined by trapezoidal integration of the first 3 points, with subsequent points fit by a decreasing monoexponential. The area under the curve was then divided by counts in the whole body, and the resulting residence times were entered into the MIRDOSE3 program. RESULTS: Primary elimination was via kidneys to the urinary bladder. There were no sex differences in organ residence times. The urinary bladder wall was the organ with the highest estimated radiation dose (1.94 x 10(-1) +/- 3.57 x 10(-2) mGy/MBq). Except for the kidney and bladder wall, correlation was good between human dosimetry estimates and estimates reported previously from rats. The human dosimetry was 6.6 and 60.6 times higher in the kidneys and urinary bladder wall, respectively, than estimates from rats. CONCLUSION: The urinary bladder wall is the critical organ for 11C-WAY100,635 in humans. In the United States, according to Radioactive Drug Research Committee guidelines a single dose cannot exceed 300 MBq in a man and 227 MBq in a woman, with up to 3 such injections permitted per annum.

Adult↗

OLINDA/EXM: the second-generation personal computer software for internal dose assessment in nuclear medicine.

UNLABELLED: The OLINDA/EXM version 1.0 personal computer code was created as a replacement for the widely used MIRDOSE3.1 code. This paper documents the basic function of the code and how it is similar to and different from the MIRDOSE software. METHODS: After creation of the code and alpha- and beta-testing phases, a premarket notification submission (510(k)) was filed with the Food and Drug Administration to permit marketing of the code. Permission was granted in June 2004, and the code is currently being distributed through Vanderbilt University. Not all of the technical details of the dosimetry methods have been shown here, as they have been previously documented. RESULTS: Agreement of doses between the MIRDOSE3.1 and OLINDA/EXM codes was good, within 1%-2% in most cases. CONCLUSION: The extensive testing of the OLINDA/EXM code, based on comparison with literature-established dose calculations and with the widely tested and accepted MIRDOSE3.1 code, should give users confidence in its output. The OLINDA/EXM code should be easy for MIRDOSE users to adopt and for new users to understand. It will be useful in standardizing and automating internal dose calculations, assessing doses in clinical trials with radiopharmaceuticals, making theoretic calculations for existing pharmaceuticals, teaching, and other purposes.

Nuclear Medicine↗

Proposed addendum to previously published fetal dose estimate tables for 18F-FDG.

Placental transfer and fetal dose estimates have been published for women in early pregnancy and at the end of each trimester for a large number of radiopharmaceuticals. For the case of (18)F-FDG, a dose was given with no information about placental transfer of the radiopharmaceutical. Recent publications have reported quantitative values for maternal and fetal uptake of (18)F-FDG in primates and new values for (18)F-FDG kinetics. In this article, these data are applied to give radiation dose estimates for the fetus at all stages of pregnancy for (18)F-FDG. The recommended values are 2.2 x 10(-2) mGy/MBq in early pregnancy, 2.2 x 10(-2) mGy/MBq at 3-mo gestation, 1.7 x 10(-2) mGy/MBq at 6-mo gestation, and 1.7 x 10(-2) mGy/MBq at 9-mo gestation.

Body Burden↗

Bone marrow dosimetry using blood-based models for radiolabeled antibody therapy: a multiinstitutional comparison.

UNLABELLED: Standardization of marrow dosimetry is of considerable importance when estimating dose-response for a multicentered clinical trial involving radionuclide therapy. However, it is only within the past five years that the intercomparison of marrow dosimetry results among separate clinical trials that use the same agent has become scientifically feasible. In this work, we have analyzed reported marrow dosimetry results from radioimmunotherapy trials and recalculated marrow absorbed doses at a central facility using a standard blood model with patient-specific source data. The basic approach used in the American Association of Physicists in Medicine (AAPM)/Sgouros marrow dosimetry methodology was common to calculation performed at all participating institutions, including the central facility. Differences in dose estimates associated with starting assumptions and the exact implementation of the AAPM/Sgouros calculation methodology used by the source institutions and the central facility were quantified and compared. METHODS: Data from 22 patients enrolled in radiolabeled antibody clinical trials were randomly selected from 7 participating institutions for the assessment of marrow dose. The analysis was restricted to those patients who were treated with 131I- or 186Re-labeled antibody and had no marrow involvement. Calculation of bone marrow dose at each participating institution was unique to the trial or institution, but all used some form of the AAPM/Sgouros blood model approach. The central facility adopted a marrow dosimetry model based on the AAPM/Sgouros model for radiolabeled antibodies using the standard MIRD approach to the remainder-of-body contribution. A standardized approach to account for variations in patient mass was used for the remainder-of-body component. To simplify clinical implementation, regional marrow uptake and time-dependent changes in the marrow-to-blood concentration ratio were not included. Methods of formatting the collection of standard datasets useful in defining dose-response parameters are also presented. RESULTS: Bone marrow doses were calculated according to the method described for each of the 22 patients based on the patient-specific data supplied by the participating institutions. These values were then individually compared with the marrow doses originally reported by each institution. Comparison of the two calculation methods was expressed as a ratio of the marrow doses for each patient. The mean ratio for the dose estimates at the participating institution calculation compared with the central laboratory value was 0.920 +/- 0.259 (mean +/- SD), with a range from 0.708 to 1.202. CONCLUSION: The independent use of the AAPM/Sgouros method blood model approach to marrow dosimetry has brought these dose estimates to within 30% of the results obtained centrally compared with substantially higher uncertainties reported previously. Variations in calculation methodology or initial assumptions adopted by individual institutions may still contribute significant uncertainty to dose estimates, even when the same data are used as a starting point for the calculation comparison shown here. A clinically relevant, standard method for marrow dosimetry for radiolabeled antibodies is proposed as a benchmark for intercomparison purposes. A parameter sensitivity analysis and a summary discussion of the use of this model for potentially improving dose-response data correlation are also presented.

Adult↗

Preclinical acute toxicity studies and rodent-based dosimetry estimates of the novel sigma-1 receptor radiotracer [(18)F]FPS.

[(18)F]1-(Fluoropropyl)-4-[(4-cyanophenoxy)methyl]piperidine ([(18)F]FPS) is a novel high affinity (KD = 0.5 nM) sigma receptor radioligand that exhibits saturable and selective in vivo binding to sigma receptors in rats, mice and non-human primates. In order to support an IND application for the characterization of [(18)F]FPS through PET imaging studies in humans, single organ and whole body radiation adsorbed doses associated with [(18)F]FPS injection were estimated from distribution data obtained in rats. In addition, acute toxicity studies were conducted in rats and rabbits and limited toxicity analyses were performed in dogs. Radiation dosimetry estimates obtained using rat biodistribution analysis of [(18)F]FPS suggest that most organs would receive around 0.012-0.015 mGy/MBq. The adrenal glands, brain, kidneys, lungs, and spleen would receive slightly higher doses (0.02-0.03 mGy/MBq). The adrenal glands were identified as the organs receiving the greatest adsorbed radiation dose. The total exposure resulting from a 5 mCi administration of [(18)F]FPS is well below the FDA defined limits for yearly cumulative and per study exposures to research participants. Extended acute toxicity studies in rats and rabbits, and limited acute toxicity studies in beagle dogs suggest at least a 175-fold safety margin in humans at a mass dose limit of 2.8 microg per intravenous injection. This estimate is based on the measured no observable effect doses (in mg/m(2)) in these species. These data support the expectation that [(18)F]FPS will be safe for use in human PET imaging studies at a maximum administration of 5 mCi and a mass dose equal to or less than 2.8 microg FPS per injection.

Animals↗

Radiotherapy with internal emitters: what can dosimetrists offer?

This paper presents a very brief overview of current methods and models in use in internal dose assessment, and discusses some challenges for the near future. Basic internal dose calculational methodologies are reviewed, and some literature and Internet resources are discussed. An overview of the proper design of kinetic studies to gather data for dose calculations is given. The limitations of current dose models and the promise of better modeling through patient-specific, image-based, methods are discussed.

Algorithms↗

Additional radiation absorbed dose estimates for Zevalin radioimmunotherapy.

Zevalin (ibritumomab tiuxetan) radioimmunotherapy is a novel treatment for non-Hodgkin's lymphoma (NHL). The Zevalin regimen includes 5 mCi (111)In-labeled Zevalin on Day 1, followed by serial anterior and posterior planar gamma images for imaging or dosimetry. On Day 8, patients receive 0.4 mCi/kg (90)Y Zevalin for radioimmunotherapy. Both Zevalin doses are preceded by 250 mg/m(2) rituximab to clear peripheral B cells and improve biodistribution of the radiolabeled antibody. In a 143-patient, Phase III, randomized study, the Zevalin regimen produced a significantly higher overall response rate than rituximab for relapsed or refractory, low-grade, follicular, or transformed NHL (80% versus 56%, p = 0.02). Fifteen patients from the Zevalin arm of this study were randomly selected for additional radiation dosimetry. (90)Y residence times were calculated from (111)In image analysis data. MIRDOSE3.1 radiation absorbed dose estimates to normal tissues were highest for spleen, testes, and liver, with considerably lower doses reaching heart, lung, intestines, red marrow, and kidneys. Radiation absorbed doses to organs and marrow were within a safe range following administration of 0.4 mCi/kg (90)Y Zevalin.

Antibodies, Monoclonal↗

Physical models and dose factors for use in internal dose assessment.

Internal dose assessment depends on the use of mathematical formulas for dose calculation and models of the human body and its organs. A simple, unified method for internal dose calculations is described, which brings together and simplifies concepts used in nuclear medicine and occupational internal dose systems previously described. Using the best current decay data and phantoms for internal dose calculations, dose factors for internal dose assessment are provided. Decay data for over 800 radionuclides from the data service at Brookhaven National Laboratory were combined with absorbed fraction data from a number of currently available mathematical whole body and organ models to provide the dose factors. This represents the first published update on nuclear medicine dose factors since MIRD Pamphlet No. 11 in 1975; in this paper, dose factors for many more nuclides are given (816 vs. 117 in MIRD 11), including some alpha emitters. New models are also employed, and dose factors for bone and marrow have been updated with recently suggested corrections. The good agreement of the new dose factors with previously published values for several of the models gives good confidence in their accuracy. This article gives an overview of the technical basis for these dose factors and some example tables of data, but the bulk of the data files will be distributed electronically. The use of an "electronic publishing" approach permits the publication of this kind of voluminous information in mainstream journals while facilitating rapid access and use without the need to purchase often expensive and bulky paper documents.

Adolescent↗

Red marrow radiation dose adjustment using plasma FLT3-L cytokine levels: improved correlations between hematologic toxicity and bone marrow dose for radioimmunotherapy patients.

UNLABELLED: Calculated red marrow absorbed dose in patients receiving radioimmunotherapy (RAIT) has not been highly predictive of the dose-limiting hematologic toxicity observed in many patient populations studied. Because patients receiving the same red marrow dose often experience different grades of toxicity, other factors might help predict the different grades of toxicity observed. One such factor may be the plasma FLT3-L (FMS-related tyrosine kinase 3 ligand, hematopoiesis stimulatory cytokine) level, which has been shown to be a better indicator of recovery of progenitor cells and, thus, red marrow radiosensitivity (because during the recovery period the progenitor cells are hyperproliferative and potentially more radiosensitive) for patients treated with previous chemotherapy than peripheral blood counts. METHODS: Red marrow radiation doses were determined for 30 patients (20 male, 10 female; all without bone marrow or bone involvement; 19 had prior chemotherapy) after receiving (131)I RAIT (activity range, 2.1-8.9 GBq) for treatment of solid cancers known to produce carcinoembryonic antigen. Radiation dose estimates were calculated using 2 different methods of red marrow cumulated activity and red marrow-to-blood activity concentration ratio determinations for 2 dosimetric models: using both male and female and male-only masses and S values. Highest platelet toxicity grade at nadir (PTG), percentage platelet decrease (PPD) in counts, and platelet nadir (PN) counts were measured. FLT3-L levels (pg/mL) were determined by immunoassay before treatment; a normal FLT3-L level was assumed to be 80 pg/mL. The red marrow radiation doses (cGy) were adjusted for the patient's FLT3-L level when the patient's cytokine level exceeded the normal value. Marrow doses and FLT3-L-adjusted marrow doses were correlated with PTG, PPD, PN, and 1/PN. Administered activity, administered activity per unit body weight, and total body radiation dose were also correlated with these hematologic toxicity measures. RESULTS: All red marrow dose calculation schemes resulted in essentially the same correlations for a given hematologic toxicity measure. Poor correlations were observed between administered activity, administered activity per unit body weight, total body radiation dose, or red marrow radiation dose and PTG, PPD, PN, and 1/PN. All correlations improved greatly when the various predictors of toxicity were adjusted for the patient's FLT3-L level. The highest correlation observed was between red marrow dose or total body dose and 1/PN (r = 0.86). Using an unadjusted red marrow dose to predict toxicity >/= grade 3, there were 8 true-positive, but 13 false-positive cases with 9 true-negatives. However, using a FLT3-L-adjusted red marrow dose, there were 8 true-positives, but only 2 false-positives and 20 true-negatives. CONCLUSION: FLT3-L-adjusted red marrow radiation doses provide improved correlation with hematologic toxicity. Thus, elevated FLT3-L plasma levels before RAIT may indicate increased radiosensitivity of the bone marrow, and use of this measurement to adjust calculated red marrow or total body radiation doses may provide significantly better prediction of toxicity than radiation dose alone, leading to a patient-specific administered activity prescription that will deliver radiation doses to diseased tissues sufficient to produce an effective treatment outcome at acceptable toxicity levels.

Blood Platelets↗