Search PubMed⌕ Search

Biomedical subjects

Michael B Beerman

Publications and source records attributed to Michael B Beerman.

3 recordsLinked to original sources

Comparison of yield and genotyping performance of multiple displacement amplification and OmniPlex whole genome amplified DNA generated from multiple DNA sources.

The promise of whole genome amplification (WGA) is that genomic DNA (gDNA) quantity will not limit molecular genetic analyses. Multiple displacement amplification (MDA) and the OmniPlex PCR-based WGA protocols were evaluated using 4 and 5 ng of input gDNA from 60 gDNA samples from three tissue sources (mouthwash, buffy coat, and lymphoblast). WGA DNA (wgaDNA) yield and genotyping performance were evaluated using genotypes determined from gDNA and wgaDNA using the AmpFlSTR Identifiler assay and N = 49 TaqMan SNP assays. Short tandem repeat (STR) and SNP genotyping completion and concordance rates were significantly reduced with wgaDNA from all WGA methods compared with gDNA. OmniPlex wgaDNA exhibited a greater reduction in genotyping performance than MDA wgaDNA. Reduced wgaDNA genotyping performance was due to allelic (all protocols) and locus (OmniPlex) amplification bias leading to heterozygote and locus dropout, respectively, and %GC sequence content (%GC) was significantly correlated with TaqMan assay performance. Lymphoblast wgaDNA exhibited higher yield (OmniPlex), buffy coat wgaDNA exhibited higher STR genotyping completion (MDA), whereas mouthwash wgaDNA exhibited higher SNP genotyping discordance (MDA). Genotyping of wgaDNA generated from < or = 5 ng gDNA, e.g., from archaeological, forensic, prenatal diagnostic, or pathology samples, may require additional genotyping validation with gDNA and/or more sophisticated analysis of genotypes incorporating observed reductions in genotyping performance.

Adult↗

Genomic regions linked to alcohol consumption in the Framingham Heart Study.

BACKGROUND: Pedigree, demographic, square-root transformed maximum alcohol (SRMAXAPD) and maximum cigarette (MAXCPD) consumption, and genome-wide scan data from the Framingham Heart Study (FHS) were used to investigate genetic factors that may affect alcohol and cigarette consumption in this population-based sample. RESULTS: A significant sister:sister correlation greater than spouse correlation was observed for MAXCPD only. Single-point sib-pair regression analysis provided nominal evidence for linkage of loci to both SRMAXAPD and MAXCPD consumption traits, with more significant evidence of linkage to SRMAXAPD than to MAXCPD. One genomic region, chr9q21.11, exhibits significant multi-point sib-pair regression to SRMAXAPD. CONCLUSION: SRMAXAPD exhibits greater evidence for genetic linkage than does MAXCPD in the FHS sample. Four regions of the genome exhibiting nominal evidence for linkage to SRMAXAPD in the FHS sample correspond to regions of the genome previously identified as linked to alcoholism or related traits in the family data set ascertained on individuals affected with alcohol dependence known as COGA.

Alcohol Drinking↗

Performance of high-throughput DNA quantification methods.

BACKGROUND: The accuracy and precision of estimates of DNA concentration are critical factors for efficient use of DNA samples in high-throughput genotype and sequence analyses. We evaluated the performance of spectrophotometric (OD) DNA quantification, and compared it to two fluorometric quantification methods, the PicoGreen assay (PG), and a novel real-time quantitative genomic PCR assay (QG) specific to a region at the human BRCA1 locus. Twenty-Two lymphoblastoid cell line DNA samples with an initial concentration of approximately 350 ng/uL were diluted to 20 ng/uL. DNA concentration was estimated by OD and further diluted to 5 ng/uL. The concentrations of multiple aliquots of the final dilution were measured by the OD, QG and PG methods. The effects of manual and robotic laboratory sample handling procedures on the estimates of DNA concentration were assessed using variance components analyses. RESULTS: The OD method was the DNA quantification method most concordant with the reference sample among the three methods evaluated. A large fraction of the total variance for all three methods (36.0-95.7%) was explained by sample-to-sample variation, whereas the amount of variance attributable to sample handling was small (0.8-17.5%). Residual error (3.2-59.4%), corresponding to un-modelled factors, contributed a greater extent to the total variation than the sample handling procedures. CONCLUSION: The application of a specific DNA quantification method to a particular molecular genetic laboratory protocol must take into account the accuracy and precision of the specific method, as well as the requirements of the experimental workflow with respect to sample volumes and throughput. While OD was the most concordant and precise DNA quantification method in this study, the information provided by the quantitative PCR assay regarding the suitability of DNA samples for PCR may be an essential factor for some protocols, despite the decreased concordance and precision of this method.

Analysis of Variance↗