Biomedical subjects
Michael A Savitt
Publications and source records attributed to Michael A Savitt.
Mitral valve repair on the beating perfused heart.
It is difficult to assess the success of mitral valve repair in the arrested heart. Various techniques have been described. Transesophageal echocardiogram (TEE) provides excellent two-dimensional evaluation of the repair, but three-dimensional anatomic characteristics are limited. We describe a simple technique for performing mitral valve repair on the beating heart. This allows accurate evaluation of valvular competence and three-dimensional anatomic characteristics prior to closure of the atriotomy.
Application of robotic-assisted techniques to the surgical evaluation and treatment of the anterior mediastinum.
BACKGROUND: We report our initial experience with the application of robotic-assisted technologies to the treatment of diseases of the anterior mediastinum. METHODS: Between October 2001 and December 2003, 18 consecutive patients with anterior mediastinal masses were referred for diagnosis and treatment. Fifteen patients underwent robotic-assisted surgery with the da Vinci robotic system. A single surgical team performed all operations. Resection was accomplished by either median sternotomy or robotic-assisted techniques. RESULTS: Fourteen patients underwent successful robotic-assisted thymectomy. One patient underwent robotic-assisted biopsy of a mass that was later determined to be a poorly differentiated carcinoma, 3 patients underwent complete thymectomy by median sternotomy for biopsy-proven extracapsular thymoma, 7 patients had thymoma, and 3 had myasthenia gravis. There were 2 patients each with benign thymic cysts and thymic hyperplasia. Primary thymic carcinoid, thymolipoma, papillary thyroid cancer, and poorly differentiated carcinoma were present in 1 patient each. No conversions, intraoperative complications, or deaths occurred in the 15 patients who underwent robotic-assisted resection. The mean operative time was 96 minutes (range 62 to 132 minutes). The mean robotic time was 48 minutes (range 22 to 76). The median hospital stay was 2 days. All patients are doing well, with a median follow-up of 1 year. CONCLUSIONS: Robotic-assisted surgery of the anterior mediastinum, and particularly thymectomy, can be performed safely and efficiently. The increased visualization and instrument dexterity afforded by this technology provides an optimal minimally invasive approach to the anterior mediastinum. From this experience we have formulated a comprehensive treatment algorithm for the surgical evaluation and treatment of patients with anterior mediastinal diseases.
Off-pump coronary artery bypass grafting decreases morbidity and mortality in a selected group of high-risk patients.
BACKGROUND: The ideal indication for off-pump coronary artery bypass grafting (OPCABG) has yet to be defined. High-risk surgical patients may benefit the most when cardiopulmonary bypass (CPB), aortic cross clamping, and cardioplegic arrest are avoided. The aim of this study was to determine whether off-pump coronary artery bypass grafting might decrease the operative morbidity and mortality in a select group of high-risk patients with multivessel coronary artery disease. METHODS: Utilizing a Parsonnet risk stratification model we analyzed prospectively collected data on a cohort of high-risk coronary artery disease patients, which were operated on with beating-heart technology by the same group of surgeons in a tertiary care university medical center. High-risk patients were defined as those with a Parsonnet score of 15 or greater. RESULTS: Fifty-seven multivessel disease OPCABG patients (over a period of 2 years) had markedly increased Parsonnet scores (24.3 +/- 10.6). The average ejection fraction of the patients was 42% (+/-12.3) and their age ranged from 52 to 85 years (mean 70.6 +/- 10.4, 26% women). Unstable angina was present in 42 patients (74%) and 10 patients underwent OPCABG within 24 hours of the occurrence of acute myocardial infarction. In addition to severe coronary artery disease 32% of the patients presented with congestive heart failure, insulin-dependent diabetes (18%), renal failure (22%), peripheral vascular disease (31%), pulmonary disease (18%), and neurologic disorders (14%). An average of 2.6 +/- 0.9 grafts/patient were performed and the posterior descending artery or marginal branches of the circumflex artery or both were grafted in 90%. The 30-day mortality rate was 3.5% (n = 2). CONCLUSIONS: OPCABG can be performed with a reasonable low morbidity and mortality in this select group of high-risk patients. OPCABG is a reasonable, and might even be preferable, operative strategy in this high-risk group of patients.
A simple technique for aortic valve replacement in patients with a patent left internal mammary artery bypass graft.
Aortic valve replacement in patients with a patent left internal mammary artery graft is often a challenge because of the difficulties with dissection of the left internal mammary artery and optimum myocardial protection. We describe a simple technique of aortic valve replacement with a beating heart and continuous coronary perfusion for this difficult group of patients.