Search PubMed⌕ Search

Biomedical subjects

Michael A Ohliger

Publications and source records attributed to Michael A Ohliger.

3 recordsLinked to original sources

Ultimate intrinsic signal-to-noise ratio for parallel MRI: electromagnetic field considerations.

A method is described for establishing an upper bound on the spatial encoding capabilities of coil arrays in parallel MRI. Ultimate intrinsic signal-to-noise ratio (SNR), independent of any particular conductor arrangement, is calculated by expressing arbitrary coil sensitivities in terms of a complete set of basis functions that satisfy Maxwell's equations within the sample and performing parallel imaging reconstructions using these basis functions. The dependence of the ultimate intrinsic SNR on a variety of experimental conditions is explored and a physically intuitive explanation for the observed behavior is provided based on a comparison between the electromagnetic wavelength and the distance between aliasing points. Imaging at high field strength, with correspondingly short wavelength, is shown to offer advantages for parallel imaging beyond those already expected due to the larger available spin polarization. One-dimensional undersampling of k-space yields a steep drop in attainable SNR for more than a 5-fold reduction of scan time, while 2D undersampling permits access to much higher degrees of acceleration. Increased tissue conductivity decreases baseline SNR, but improves parallel imaging performance. A procedure is also provided for generating the optimal coil sensitivity pattern for a given acceleration, which will serve as a useful guide for future coil designs.

Algorithms↗

Self-calibrating parallel imaging with automatic coil sensitivity extraction.

Calibration of the spatial sensitivity functions of coil arrays is a crucial element in parallel magnetic resonance imaging (PMRI). The most common approach has been to measure coil sensitivities directly using one or more low-resolution images acquired before or after accelerated data acquisition. However, since it is difficult to ensure that the patient and coil array will be in exactly the same positions during both calibration scans and accelerated imaging, this approach can introduce sensitivity miscalibration errors into PMRI reconstructions. This work shows that it is possible to extract sensitivity calibration images directly from a fully sampled central region of a variable-density k-space acquisition. These images have all the features of traditional PMRI sensitivity calibrations and therefore may be used for any PMRI reconstruction technique without modification. Because these calibration data are acquired simultaneously with the data to be reconstructed, errors due to sensitivity miscalibration are eliminated. In vivo implementations of self-calibrating parallel imaging using a flexible coil array are demonstrated in abdominal imaging and in real-time cardiac imaging studies.

Abdomen↗

Recent advances in image reconstruction, coil sensitivity calibration, and coil array design for SMASH and generalized parallel MRI.

Parallel magnetic resonance imaging (MRI) techniques use spatial information from arrays of radiofrequency (RF) detector coils to accelerate imaging. A number of parallel MRI techniques have been described in recent years, and numerous clinical applications are currently being explored. The advent of practical parallel imaging presents various challenges for image reconstruction and RF system design. Recent advances in tailored SiMultaneous Acquisition of Spatial Harmonics (SMASH) image reconstructions are summarized. These advances enable robust SMASH imaging in arbitrary image planes with a wide range of coil array geometries. A generalized formalism is described which may be used to understand the relations between SMASH and SENSE, to derive typical implementations of each as special cases, and to form hybrid techniques combining some of the advantages of both. Accurate knowledge of coil sensitivities is crucial for parallel MRI, and errors in calibration represent one of the most common and the most pernicious sources of error in parallel image reconstructions. As one example, motion of the patient and/or the coil array between the sensitivity reference scan and the accelerated acquisition can lead to calibration errors and reconstruction artifacts. Self-calibrating parallel MRI approaches that address this problem by eliminating the need for external sensitivity references are reviewed. The ultimate achievable signal-to-noise ratio (SNR) for parallel MRI studies is closely tied to the geometry and sensitivity patterns of the coil arrays used for spatial encoding. Several parallel imaging array designs that depart from the traditional model of overlapped adjacent loop elements are described.

Calibration↗