Meei-Ling Jan

Publications and source records attributed to Meei-Ling Jan.

7 recordsLinked to original sources

Scatter correction for 3D PET using beam stoppers combined with dual-energy window acquisition: a feasibility study.

Fully three-dimensional (3D) positron emission tomography (PET) can achieve high sensitivity of coincidence events, but the absence of inter-slice septa inevitably leads to increased scattered events. The scattered events can represent as much as 50% of the total detected events. In this research, we proposed a scatter correction method for 3D PET based on beam stoppers and dual-energy window acquisition. The beam stoppers were placed surrounding the object to attenuate primary beams. The scatter fractions were directly estimated at those blocked lines of response and then the entire scatter fraction distribution was recovered using the dual-energy window ratio as reference. The performance was evaluated by using Monte Carlo simulations of various digital phantoms. For the Utah phantom study, the proposed method accurately estimated the scatter fraction distribution, and improved image contrast and quantification based on four different quality indices as performance measures. For the non-homogeneous Zubal phantom, the simulated results also demonstrated that the proposed method achieved a better restoration of image contrast than the dual-energy window method. We conclude that the proposed scatter correction method could effectively suppress various kinds of scattered events, including multiple scatter and scatter from outside the field of view.

Computer Simulation↗

A maximum likelihood expectation maximization algorithm with thresholding.

The maximum likelihood expectation maximization (MLEM) algorithm has several advantages over the conventional filtered back-projection (FBP) for image reconstruction. However, the slow convergence and the high computational cost for its practical implementation have limited its clinical applications. This study proposes the incorporation of a thresholding technique in both the MLEM and ordered subsets EM (OSEM) algorithm to accelerate convergence. The threshold is set to c*m, where m is the mean pixel value of the whole image. The reconstruction time is proportional to the total number of pixels, so a thresholding technique that nullifies the value of a pixel if it falls below a threshold, can effectively remove the non-active pixels and substantially accelerate reconstruction. Preliminary tests on simulated PET data reveal that the thresholding technique accelerates the convergence rate and reduce error in the reconstructed image. The reconstruction performance improves with the increase of the threshold level and the MSE reaches minimum for c value equals to about 1.

Algorithms↗

Coincidence planar imaging for dynamic [18F]FDG uptake in nude mice with tumors and inflammation: correlated with histopathology and micro-autoradiography.

The Institute of Nuclear Energy Research of Taiwan has developed a dynamic coincidence detection device for positron emitted radiotracer pharmacodynamic study in small mice models. In this study, we set up an experimental paradigm by determining [fluorine-18]-2-deoxy-2-fluoro-D-glucose ([18F]FDG) dynamic uptake in tumors and inflammations in nude mice as the foundation for future applications in therapy development. Histopathology and micro-autoradiography of these tumors and inflammations were obtained for confirmation. Dynamic coincidence planar images of six tumors and two inflammations in nude mice were acquired over 4 hours immediately after injection of 25.9 MBq of [18F]FDG into the right thigh of each animal. After image reconstruction, the lesion-to-background ratios were calculated in regions of interest over the lesion and contralateral thigh to determine the equilibrium status of the radiotracer. All mice were sacrificed for histopathologic examination and six of the mice were examined with micro-autoradiography. [18F]FDG uptake in tumors and inflammations both reached equilibrium about 3 hours after injection. At equilibrium, [18F]FDG uptake into tumors was two to four times higher than the background. Uptake into the 4-day and 8-day inflammations was 2.3 and 5.5 times higher than the background, respectively. Histopathology showed macrophage and neutrophil infiltration around the tumors and in the inflammations. Micro-autoradiography showed dense silver grains in the granulation tissue surrounding the tumors and inflammations. The preliminary results suggested that dynamic [18F]FDG coincidence planar imaging can help in determining the suitable time for static [18F]FDG imaging in nude mice models. The optimal time for static [18F]FDG positron emission tomography imaging was around 3 hours after injection. The paradigm for determining a dynamic [18F]FDG uptake pattern was demonstrated for future new therapeutic drug experimental use.

Animals↗

A three-dimensional registration method for automated fusion of micro PET-CT-SPECT whole-body images.

Micro positron emission tomography (PET) and micro single-photon emission computed tomography (SPECT), used for imaging small animals, have become essential tools in developing new pharmaceuticals and can be used, among other things, to test new therapeutic approaches in animal models of human disease, as well as to image gene expression. These imaging techniques can be used noninvasively in both detection and quantification. However, functional images provide little information on the structure of tissues and organs, which makes the localization of lesions difficult. Image fusion techniques can be exploited to map the functional images to structural images, such as X-ray computed tomography (CT), to support target identification and to facilitate the interpretation of PET or SPECT studies. Furthermore, the mapping of two functional images of SPECT and PET on a structural CT image can be beneficial for those in vivo studies that require two biological processes to be monitored simultaneously. This paper proposes an automated method for registering PET, CT, and SPECT images for small animals. A calibration phantom and a holder were used to determine the relationship among three-dimensional fields of view of various modalities. The holder was arranged in fixed positions on the couches of the scanners, and the spatial transformation matrix between the modalities was held unchanged. As long as objects were scanned together with the holder, the predetermined matrix could register the acquired tomograms from different modalities, independently of the imaged objects. In this work, the PET scan was performed by Concorde's microPET R4 scanner, and the SPECT and CT data were obtained using the Gamma Medica's X-SPECT/CT system. Fusion studies on phantoms and animals have been successfully performed using this method. For microPET-CT fusion, the maximum registration errors were 0.21 mm +/- 0.14 mm, 0.26 mm +/- 0.14 mm, and 0.45 mm +/- 0.34 mm in the X (right-left), Y (upper lower), and Z (rostral-caudal) directions, respectively; for the microPET-SPECT fusion, they were 0.24 mm +/- 0.14 mm, 0.28 mm +/- 0.15 mm, and 0.54 mm +/- 0.35 mm in the X, Y, and Z directions, respectively. The results indicate that this simple method can be used in routine fusion studies.

Algorithms↗

Quality degradation in lossy wavelet image compression.

The objective of this study was to develop a method for measuring quality degradation in lossy wavelet image compression. Quality degradation is due to denoising and edge blurring effects that cause smoothness in the compressed image. The peak Moran z histogram ratio between the reconstructed and original images is used as an index for degradation after image compression. The Moran test is applied to images randomly selected from each medical modality, computerized tomography, magnetic resonance imaging, and computed radiography and compressed using the wavelet compression at various levels. The relationship between the quality degradation and compression ratio for each image modality agrees with previous reports that showed a preference for mildly compressed images. Preliminary results show that the peak Moran z histogram ratio can be used to quantify the quality degradation in lossy image compression. The potential for this method is applications for determining the optimal compression ratio (the maximized compression without seriously degrading image quality) of an image for teleradiology.

Diagnostic Imaging↗

A novel image quality index using Moran I statistics.

Measurement of image quality is very important for various applications such as image compression, restoration and enhancement. Conventional methods (e.g., mean squared error; MSE) use error summation to measure quality change pixel by pixel and do not correlate well with subjective quality measurement. This is due to the fact that human eyes extract structural information from the viewing field. In this study a new quality index using a Moran I statistics is proposed. The Moran statistic that measures the sharpness from a local area is a good index of quality as most image processing techniques alter the smoothness of the image. Preliminary results show that the new quality index outperforms the MSE significantly under various types of image distortions.

Algorithms↗

Determination of beam intensity in a single step for IMRT inverse planning.

In intensity modulated radiotherapy (IMRT), targets are treated by multiple beams at different orientations each with spatially-modulated beam intensities. This approach spreads the normal tissue dose to a greater volume and produces a higher dose conformation to the target. In general, inverse planning is used for IMRT treatment planning. The inverse planning requires iterative calculation of dose distribution in order to optimize the intensity profile for each beam and is very computation intensive. In this paper, we propose a single-step method utilizing a figure of merit (FoM) to estimate the beam intensities for IMRT treatment planning. The FoM of a ray is defined as the ratio between the delivered tumour dose and normal tissue dose and is a good index for the dose efficacy of the ray. To maximize the beam utility, it is natural to irradiate the tumour with intensity of each ray proportional to the value of the FoM. The nonuniform beam intensity profiles are then fixed and the weights of the beam are determined iteratively in order to yield a uniform tumour dose. In this study, beams are employed at equispaced angles around the patient. Each beam with its field size that just covers the tumour is divided into a fixed number of beamlets. The FoM is calculated for each beamlet and this value is assigned to be the beam intensity. Various weighting factors are incorporated in the FoM computation to accommodate different clinical considerations. Two clinical datasets are used to test the feasibility of the algorithm. The resultant dose-volume histograms of this method are presented and compared to that of conformal therapy. Preliminary results indicate that this method reduces the critical organ doses at a small expense of uniformity in tumour dose distribution. This method estimates the beam intensity in one single step and the computation time is extremely fast and can be finished in less than one minute using a regular PC.

Algorithms↗